Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dose, detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Introduction, Investigation, and Experimental Validation of a Novel Passive Neutron Spectrometer

Unfolding neutron energy spectra are instrumental for determining personal health effects and calculating dose received. This area of study is heavily researched, and Lawrence Livermore National Laboratory (LLNL) is investigating a passive neutron spectrometer for the purpose of acquiring the information needed to determine personnel dose in the event of a criticality accident. A part of this investigation is presented in this article through the examination of four experimental detector responses (DRs). These four DRs were acquired in the presence of 252 Cf, AmBe, GODIVA, and National Ignition Facility (NIF) neutron sources. An algorithm developed at LLNL was used to unfold the neutron fluence from each of the four DRs, and subsequently, fluence-to-dose conversion factors provided by the American National Standards Institute were used to calculate dose. Additionally, a multistep unfolding process was developed and employed to calculate the effects of both direct (from the source) and indirect (from room return) neutrons. The average error when unfolding the direct DR was less than 8%. The dose from 252 Cf was predicted with only 8% error. The multistep approach allowed for the identification of the low-energy neutrons in the 252 Cf, AmBe, and NIF DRs.

Nuclear Criticality Safety Program (NCSP)↗

Proton Radiation Effects on HgCdTe Avalanche Photodiode Detectors

Space radiation damage and proton induced transient effects were evaluated on 4.4 μm cutoff HgCdTe avalanche photodiode (APD) arrays developed by Leonardo DRS. Device performances as a function of total dose up to 100 krad (Si) were measured with ~60 MeV protons on 3 types of APD samples: 4x4 pixel APD fanout arrays with and without connection to a read-out integrated circuit (ROIC), and a 2x8 pixel photon counting APD focal plane array (FPA). A gamma-ray test was also conducted to study ionization effects. Both APD arrays exhibited a small decrease in the quantum efficiency and a linear increase in the dark current with the proton fluence. The 2x8 pixel photon counting FPA also exhibited an increase in the dark count rate with proton dose. After the proton irradiation and an overnight room temperature warm-up, the APD dark currents at 80 K increased significantly in both types of APD arrays. All radiation damage to these HgCdTe APD arrays annealed out after baking them at >85 °C for several hours. Transient protons through the devices were found to cause large pulses at the detector output but recover within 1 μs.

Xiaoli Sun↗

Na 22 activation level measurements of fused silica rods in the LHC target absorber for neutrals compared to simulations

The Target Absorbers for Neutrals (TANs) are located in a high intensity radiation environment inside the tunnel of the Large Hadron Collider (LHC). TANs are positioned about 140 m downstream from the beam interaction points. Seven 40-cm long fused silica rods with different dopant specifications were irradiated in the TAN by the Beam RAte of Neutrals (BRAN) detector group during p + p data taking from 2016 to 2018 at the LHC. The peak dose delivered to the fused silica rods was 18 MGy. We report measurements of the 22 Na activation of the fused silica rods carried out at the University of Illinois at Urbana-Champaign and Argonne National Laboratory. At the end of the irradiation campaign, the maximum 22 Na activity observed was A = 21 kBq/cm 3 corresponding to a density, ρ = 2.5 x 10 12 /cm 3 , of 22 Na nuclei. FLUKA Monte Carlo simulations have been performed by the CERN FLUKA team to estimate 22 Na activities for the irradiated BRAN rod samples. The simulations reproduce the 22 Na activity profile measured along the rods, with a 35% underestimation of the experimental measurement results.

43 PARTICLE ACCELERATORS↗

Radiation experiments on Cosmos 2044: K-7-41, parts A, B, C, D, E

The Cosmos 2044 biosatellite mission offered the opportunity for radiation measurements under conditions which are seldom available (an inclination of 82.3 deg and attitude of 294 x 216 km). Measurements were made on the outside of the spacecraft under near-zero shielding conditions. Also, this mission was the first in which active temperature recorders (the ATR-4) were flown to record the temperature profiles of detector stacks. Measurements made on this mission provide a comparison and test for modeling of depth doses and LET spectra for orbital parameters previously unavailable. Tissue absorbed doses from 3480 rad (252 rad/d) down to 0.115 rad (8.33 mrad/d) were measured at different depths (0.0146 and 3.20 g/sq cm, respectively) with averaged TLD readings. The LET spectra yielded maximum and minimum values of integral flux of 27.3 x 10(exp -4) and 3.05 x 10(exp -4)/sq cm/s/sr, of dose rate of 7.01 and 1.20 mrad/d, and of dose equivalent rate of 53.8 and 11.6 mrem/d, for LET(sub infinity)-H2O is greater than or equal to 4 keV/micron. Neutron measurements yielded 0.018 mrem/d in the thermal region, 0.25 mrem/d in the resonance region and 3.3 mrem/d in the high energy region. The TLD depth dose and LET spectra were compared with calculations from the modeling codes. The agreement is good but some further refinements are in order. In comparing measurements on Cosmos 2044 with those from previous Cosmos missions (orbital inclinations of 62.8 deg) there is a greater spread (maximum to minimum) in depth doses and an increased contribution from GCRs, and higher LET particles, in the heavy particle fluxes.

Frank, A. L.↗

Dosimetry on STS-42 with the RME APD

Beginning with the STS-42 mission, this laboratory began participating in instrument comparison studies in which space radiation was measured contiguously by passive and active methods. The active instrument was the RME-3 microdosimeter. This instrument measures four-channel LET spectra and employs a tissue-equivalent proportional counter. It is sensitive to the full LET range of ionizing radiation present. Our area passive dosimeter, the RME APD, contained arrays of plastic nuclear track detectors (PNTD's) and thermoluminescent detectors (TLD's). The PNTD's measure LET spectra, while the TLD's measure total absorbed dose. The object of this experiment is to compare the active and passive measurements on the basis of LET spectra, total absorbed dose, and dose equivalent. The STS-42 mission was launched on January 22, 1992, with a flight duration of 8.052 days. The orbit had an inclination of 57 deg and an altitude of 302 km. The shuttle in this orbit is expected to encounter radiation levels dominated by galactic cosmic rays (GCR's) with a lesser contribution from trapped protons in the lower region of the South Atlantic Anomaly (SAA).

Source record↗

Experiment K-7-41: Radiation Experiments on Cosmos 2044

The Cosmos 2044 biosatellite mission offered the opportunity for radiation measurements under conditions which are seldom available (an inclination of 82.3 degrees and altitude of 294 x 216 km). Measurements were made on the outside of the spacecraft under near-zero shielding conditions. Also, this mission was the first in which active temperature recorders (the ATR-4) were flown to record the temperature profiles of detector stacks. Measurements made on this mission provide a comparison and test for modeling of depth doses and LET spectra for orbital parameters previously unavailable. Tissue absorbed doses from 3480 rad (252 rad/d) down to 0.115 rad (8.33 mrad/d) were measured at different depths (0.0146 and 3.20 g/sq. cm, respectively) with averaged TLD readings. The LET spectra yielded maximum and minimum values of integral flux of 27.3 x 10-4 and 3.05 x 10(exp -4) cm(exp -2).s(exp -1).sr(exp -4) of dose rate of 7.01 and 1.20 mrad/d, and of dose equivalent rate of 53.8 and 11.6 mrem/d, for LET(infinity).H2O is greater than or equal to 4 keV/micro-m. Neutron measurements yielded 0.018 mremld in the thermal region, 0.25 mrem/d in the resonance region and 3.3 mrem/d in the high energy region. The TLD depth dose and LET spectra have been compared with calculations from the modeling codes. The agreement is good but some further refinements are in order. In comparing measurements on Cosmos 2044 with those from previous Cosmos missions (orbital inclinations of 62.8 degrees) there is a greater spread (maximum to minimum) in depth doses and an increased contribution from GCR's, and higher LET particles, in the heavy particle fluxes.

Benton, E. V.↗

Effective dose equivalent on the ninth Shuttle--Mir mission (STS-91)

Organ and tissue doses and effective dose equivalent were measured using a life-size human phantom on the ninth Shuttle-Mir Mission (STS-91, June 1998), a 9.8-day spaceflight at low-Earth orbit (about 400 km in altitude and 51.65 degrees in inclination). The doses were measured at 59 positions using a combination of thermoluminescent dosimeters of Mg(2)SiO(4):Tb (TDMS) and plastic nuclear track detectors (PNTD). In correcting the change in efficiency of the TDMS, it was assumed that reduction of efficiency is attributed predominantly to HZE particles with energy greater than 100 MeV nucleon(-1). A conservative calibration curve was chosen for determining LET from the PNTD track-formation sensitivities. The organ and tissue absorbed doses during the mission ranged from 1.7 to 2.7 mGy and varied by a factor of 1.6. The dose equivalent ranged from 3.4 to 5.2 mSv and varied by a factor of 1.5 on the basis of the dependence of Q on LET in the 1990 recommendations of the ICRP. The effective quality factor (Q(e)) varied from 1.7 to 2.4. The dose equivalents for several radiation-sensitive organs, such as the stomach, lung, gonad and breast, were not significantly different from the skin dose equivalent (H(skin)). The effective dose equivalent was evaluated as 4.1 mSv, which was about 90% of the H(skin).

NASA Center JSC↗

DARHT Axis 1 Bremsstrahlung Dose Measurements

he Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography ca pabilities using two electron Linear Induction Accelerators (LIA’s). Axis-1 of DARHT produces, nominally, a 20-MeV, 1.5-kA, 80-ns-Full Width at Half Max (FWHM) electron beam. The elec tron beam is focused on to a tantalum target to produce a Bremsstrahlung x-ray dose for flash radiography of dynamic systems. This paper will describe and compare a variety of techniques for determining the x-ray dose for two different beam currents produced by a 55mm and 70mm diameter cathode. The data was taken in November of 2022 on DARHT Axis 1. The experimen tal measurement techniques include a platinum calorimeter, a diamond radiation detector (DRD), and a Compton diode (CD). Gafchromic EBT3 self-developing dosimetry film was also used, but no useful results were obtained. Beam charge and energy were recorded and dose was calculated with this information using xtr with Dosecalcx, and simple dose charge-energy scaling. In this pa per, we will discuss the target geometry and experimental layout, the methods of measuring dose, dose diagnostics and measurement of beam charge and energy, and the comparisons of data and calculations.

43 PARTICLE ACCELERATORS↗

Space radiation absorbed dose distribution in a human phantom

The radiation risk to astronauts has always been based on measurements using passive thermoluminescent dosimeters (TLDs). The skin dose is converted to dose equivalent using an average radiation quality factor based on model calculations. The radiological risk estimates, however, are based on organ and tissue doses. This paper describes results from the first space flight (STS-91, 51.65 degrees inclination and approximately 380 km altitude) of a fully instrumented Alderson Rando phantom torso (with head) to relate the skin dose to organ doses. Spatial distributions of absorbed dose in 34 1-inch-thick sections measured using TLDs are described. There is about a 30% change in dose as one moves from the front to the back of the phantom body. Small active dosimeters were developed specifically to provide time-resolved measurements of absorbed dose rates and quality factors at five organ locations (brain, thyroid, heart/lung, stomach and colon) inside the phantom. Using these dosimeters, it was possible to separate the trapped-proton and the galactic cosmic radiation components of the doses. A tissue-equivalent proportional counter (TEPC) and a charged-particle directional spectrometer (CPDS) were flown next to the phantom torso to provide data on the incident internal radiation environment. Accurate models of the shielding distributions at the site of the TEPC, the CPDS and a scalable Computerized Anatomical Male (CAM) model of the phantom torso were developed. These measurements provided a comprehensive data set to map the dose distribution inside a human phantom, and to assess the accuracy and validity of radiation transport models throughout the human body. The results show that for the conditions in the International Space Station (ISS) orbit during periods near the solar minimum, the ratio of the blood-forming organ dose rate to the skin absorbed dose rate is about 80%, and the ratio of the dose equivalents is almost one. The results show that the GCR model dose-rate predictions are 20% lower than the observations. Assuming that the trapped-belt models lead to a correct orbit-averaged energy spectrum, the measurements of dose rates inside the phantom cannot be fully understood. Passive measurements using 6Li- and 7Li-based detectors on the astronauts and inside the brain and thyroid of the phantom show the presence of a significant contribution due to thermal neutrons, an area requiring additional study.

STS-91 Shuttle Project↗

Radiation response issues for infrared detectors

Researchers describe the most important radiation response issues for infrared detectors. In general, the two key degradation mechanisms in infrared detectors are the noise produced by exposure to a flux of ionizing particles (e.g.; trapped electronics and protons, debris gammas and electrons, radioactive decay of neutron-activated materials) and permanent damage produced by exposure to total dose. Total-dose-induced damage is most often the result of charge trapping in insulators or at interfaces. Exposure to short pulses of ionization (e.g.; prompt x rays or gammas, delayed gammas) will cause detector upset. However, this upset is not important to a sensor unless the recovery time is too long. A few detector technologies are vulnerable to neutron-induced displacement damage, but fortunately most are not. Researchers compare the responses of the new technologies with those of the mainstream technologies of PV HgCdTe and IBC Si:As. One important reason for this comparison is to note where some of the newer technologies have the potential to provide significantly improved radiation hardness compared with that of the mainstream technologies, and thus to provide greater motivation for the pursuit of these technologies.

Kalma, Arne H.↗

Proton calibration of low energy neutron detectors containing (6)LiF

The purpose of the present calibrations is to measure the proton response of the detectors with accelerated beams having energies within the region of maximum intensities in the trapped proton spectrum encountered in near-Earth orbit. This response is compared with the responses of the spaceflight detectors when related to proton exposures. All of the spaceflight neutron measurements have been accompanied by TLD absorbed doses measurements in close proximity within the spacecraft. For purposes of comparison, the spaceflight TLD doses are assumed to be proton doses.

Benton, E. V.↗

In-Situ Spectrometry of Neutrons

High energy charged particles of extra-galactic, galactic and solar origin collide with spacecraft structures in Earth orbit outside the atmosphere and in interplanetary travel beyond the Earth's magnetosphere. These primaries create a number of secondary particles inside the structures that can produce a significant ionizing radiation environment. This radiation is a threat to long term inhabitants or travelers for space missions and produces an increased risk of cancer and DNA damage. The primary high energy cosmic rays and trapped protons collide with common spacecraft materials such as aluminum and silicon and create secondary particles inside structures that are mostly protons and neutrons. Charged protons are readily detected and instruments are already in existence for this task. Neutrons are electrically neutral and therefore much more difficult to measure and detect. These neutrons are reported to contribute 30-60% of the dose inside space structures and cannot be ignored. Currently there is no compact, portable and real time neutron detector instrumentation available for use inside spacecraft or on planetary surfaces where astronauts will live and work. We propose to design and build a portable, low power and robust neutron spectrometer that will measure the neutron spectrum from 10 KeV to 500 MeV with at least 10% energy resolution in the various energy intervals. This instrument will monitor the existing neutron environment both inside spacecraft structures and on planetary surfaces to determine the safest living areas, warn of high fluxes associated with solar storms and assist the NSBRI Radiation Effects Team in making an accurate assessment of increased cancer risk and DNA damage to astronauts. The instrument uses a highly efficient proportional counter Helium 3 tube at the lowest energy intervals where .equivalent damage factors for tissue are the highest (10 KeV-2 MeV). The Helium 3 tube may be shielded with a cadmium absorber to eliminate the much less damaging, but more prevalent, thermal and epithermal neutrons and to make the structure of the spectrum more accurate in the 20 KeV-2 MeV range; or a pair of tubes, one shielded and one unshielded, can be combined so that the difference in their counts yields the thermal neutron contribution. The spectrometer also uses a 5mm lithium drifted bulk silicon solid state detector in the medium energy range of 2-20 Mev and two standard silicon surface barrier detectors separated by tens of millimeters behind a I cm thick polyethylene moderator in a stack or telescope arrangement for the high energy neutrons (>20 MeV). In the medium and high energy regions equivalent damage factors are lower but hits from one or a small number of neutrons may prove to be important. The silicon detector systems for medium and high energy neutrons will discriminate against charged particles by using a plastic cesium iodide scintillator of an appropriate geometry monitored by a silicon PIN photodiode.

Maurer, Richard H.↗

Monitoring of Ionic Silver Biocide with Capacitively-Coupled Contactless Conductivity Detection (C4D)

Monitoring of biocide dosing in spacecraft potable water systems is desirable to ensure dosing system operation and resultant microbial control. Electrolytic conductivity is linearly related to the concentration ionic silver (Ag+, the baseline biocide for future NASA missions) chemically dosed into highly purified water, and could serve as a proxy measurement. Traditional conductivity cells rely on immersed metal or graphite electrodes, which may potentially be subject to significant current-induced or auto-galvanic deposition of Ag+. Furthermore, oxide fouling may potentially induce measurement errors. Capacitively-coupled contactless conductivity detection (C4D) is a promising alternative. C4D uses electrodes placed outside an inert, non-conductive flow path, potentially mitigating such problems. We identified and purchased a commercial C4D system with claimed performance (conductivity range: 20 nS/cm to 4 µS/cm) appropriate for this application. We characterized the instrument’s performance with conductivity standards and Ag+ solutions. We began investigations considering practical and long-term detector operation, including potential current-induced deposition of conductive deposits at the tubing wall. In addition, we designed a side-stream flow system to provide liquid flow through the narrow tubing (1/16” outer diameter) required by the detector and characterized the performance of the combined C4D detector/flow system. Finally, we completed theoretical modeling of expected conductivity change with multiple dosing techniques and water chemistries.

Lance Dean Delzeit↗

RadLab: A Comprehensive Database and Graphical and Programming Interfaces for Space Radiation Data

RadLab, a component of the NASA Open Science Data Repository (OSDR), is a database of radiation measurements from multiple instruments and spacecraft that provides visual and programmatic interfaces for interrogation and retrieval of these data. The attributes of data available through RadLab include spacecraft, types of radiation sensing instruments, locations within the spacecraft (e.g. ISS modules), associated celestial bodies, trajectories, and spacecraft coordinates; the primary type of data is the absorbed dose rate, as well as flux and dose equivalent rate where available. The application programming interface (API) implements a request syntax for retrieval of timestamped data filtered by various combinations of such attributes; the graphical user interface (GUI) extends this functionality with visualizations (time series plots, comparison plots, geospatial visualizations) which provide easy means to assess data availability, iteratively refine search parameters, interactively inspect the data, and export target data subsets. Datasets are continuously being added to the RadLab database as part of the rolling release process. Investigators from multiple countries, including the US, Canada, Germany, Bulgaria, Hungary, Italy, Japan, Russia and the Czech Republic, have committed to provide data from their instruments in and beyond low Earth orbit. The current release contains datasets provided by US and international collaborators and includes readings from multiple modules of the ISS, the BioSentinel CubeSat, Chang’e 4, the Lunar Reconnaissance Orbiter, the ExoMars Orbiter, and the Curiosity rover. Datasets are associated with respective RadLab knowledgebase articles which include instrument descriptions and provide bibliographical references. RadLab aims to provide a comprehensive, dynamic compendium of space radiation data, enabling the scientific community to perform analyses of data from multiple detectors and to determine the radiation environment of research missions and experiments. Some of its applications include inference of absorbed radiation dose for NASA GeneLab payloads, and training predictive models as part of the 2024 FDL-X challenge. The platform is actively expanding and seeking additional data, with plans to also cover past (e.g. Shuttle, Mir) and future (e.g. Artemis) missions. The RadLab Working Group has been created to aid in this process as well as to foster collaborations among data contributors and users, to develop standards for data harmonization, and to guide the development of the platform, with the goal to establish the use of RadLab in space radiation research and to advance our understanding of the radiation environment in outer space.

Kirill Grigorev↗

RadLab: A Comprehensive Database and Graphical and Programming Interfaces for Space Radiation Data

RadLab, a component of the NASA Open Science Data Repository (OSDR), is a database of radiation measurements from multiple instruments and spacecraft that provides visual and programmatic interfaces for interrogation and retrieval of these data. The attributes of data available through RadLab include spacecraft, types of radiation sensing instruments, locations within the spacecraft (e.g. ISS modules), associated celestial bodies, trajectories, and spacecraft coordinates; the primary type of data is the absorbed dose rate, as well as flux and dose equivalent rate where available. The application programming interface (API) implements a request syntax for retrieval of timestamped data filtered by various combinations of such attributes; the graphical user interface (GUI) extends this functionality with visualizations (time series plots, comparison plots, geospatial visualizations) which provide easy means to assess data availability, iteratively refine search parameters, interactively inspect the data, and export target data subsets. Datasets are continuously being added to the RadLab database as part of the rolling release process. Investigators from multiple countries, including the US, Canada, Germany, Bulgaria, Hungary, Italy, Japan, Russia and the Czech Republic, have committed to provide data from their instruments in and beyond low Earth orbit. The current release contains datasets provided by US and international collaborators and includes readings from multiple modules of the ISS, the BioSentinel CubeSat, Chang’e 4, the Lunar Reconnaissance Orbiter, the ExoMars Orbiter, and the Curiosity rover. Datasets are associated with respective RadLab knowledgebase articles which include instrument descriptions and provide bibliographical references. RadLab aims to provide a comprehensive, dynamic compendium of space radiation data, enabling the scientific community to perform analyses of data from multiple detectors and to determine the radiation environment of research missions and experiments. Some of its applications include inference of absorbed radiation dose for NASA GeneLab payloads, and training predictive models as part of the 2024 FDL-X challenge. The platform is actively expanding and seeking additional data, with plans to also cover past (e.g. Shuttle, Mir) and future (e.g. Artemis) missions. The RadLab Working Group has been created to aid in this process as well as to foster collaborations among data contributors and users, to develop standards for data harmonization, and to guide the development of the platform, with the goal to establish the use of RadLab in space radiation research and to advance our understanding of the radiation environment in outer space.

Kirill Grigorev↗

Seeing structural evolution of organic molecular nano-crystallites using 4D scanning confocal electron diffraction (4D-SCED)

Abstract Direct observation of organic molecular nanocrystals and their evolution using electron microscopy is extremely challenging, due to their radiation sensitivity and complex structure. Here, we introduce 4D-scanning confocal electron diffraction (4D-SCED), which enables direct in situ observation of bulk heterojunction (BHJ) thin films. 4D-SCED combines confocal electron optic setup with a pixelated detector to record focused spot-like diffraction patterns with high angular resolution, using an order of magnitude lower dose than previous methods. We apply it to study an active layer in organic solar cells, namely DRCN5T:PC 71 BM BHJ thin films. Structural details of DRCN5T nano-crystallites oriented both in- and out-of-plane are imaged at ~5 nm resolution and dose budget of ~5 e − /Å 2 . We use in situ annealing to observe the growth of the donor crystals, evolution of the crystal orientation, and progressive enrichment of PC 71 BM at interfaces. This highly dose-efficient method opens more possibilities for studying beam sensitive soft materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deep learning at the edge enables real-time streaming ptychographic imaging

Abstract Coherent imaging techniques provide an unparalleled multi-scale view of materials across scientific and technological fields, from structural materials to quantum devices, from integrated circuits to biological cells. Driven by the construction of brighter sources and high-rate detectors, coherent imaging methods like ptychography are poised to revolutionize nanoscale materials characterization. However, these advancements are accompanied by significant increase in data and compute needs, which precludes real-time imaging, feedback and decision-making capabilities with conventional approaches. Here, we demonstrate a workflow that leverages artificial intelligence at the edge and high-performance computing to enable real-time inversion on X-ray ptychography data streamed directly from a detector at up to 2 kHz. The proposed AI-enabled workflow eliminates the oversampling constraints, allowing low-dose imaging using orders of magnitude less data than required by traditional methods.

36 MATERIALS SCIENCE↗