Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

LA100 Equity Strategies. Chapter 12: Distribution Grid Upgrades for Equitable Resilience and Solar, Storage, and Electric Vehicle Access

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. As Los Angeles transitions toward clean energy, existing distribution grid infrastructure will need to be updated and expanded to support reliable service during routine operations, enable interconnection with distributed energy resources and electrified loads, and provide access to energy-related services during disasters. This chapter focuses on equity in distribution grid upgrades, reliability, and resilience in Los Angeles. Specifically, NREL performed grid upgrade and resilience analyses using a detailed model of the distribution grid and income-differentiated household load profiles, electric vehicle (EV) adoption patterns, distributed solar adoption, and grid reliability to explore two key questions to inform how the City of Los Angeles can ensure a resilient and reliable distribution grid for all communities during the clean energy transition: Where can distribution system upgrades can be prioritized to enable equitable access to, and adoption of, clean energy technologies and how can Los Angeles provide equitable, resilient access to electricity-related services (e.g., health care, food) during disaster events like earthquakes and flooding? The electric distribution system is the "last mile" of the grid, linking the multistate bulk power system with customers; new loads, including EVs; and distributed energy resources, such as customer and community solar and storage. This analysis focuses on the 4.8-kilovolt (kV) system, including service transformers that represent the utility-side of the grid connection for most residential customers. Chapter 17 looks at the customer-side of the grid connection with a focus on electric panel upgrade needs. The transition toward clean energy can put additional stress on the distribution system from distributed energy resources and electrification - especially EVs and increased use of electricity for heating, cooling, cooking, and hot water. This stress, measured here as the number of equipment overloads and voltage violations, correlates strongly to grid reliability and therefore is used as a proxy for understanding additional upgrades needed and to help ensure equitable access to electrification and distributed energy resources. NREL also conducted community resilience analysis to examine customer-level access to both electricity and a larger range of services, such as hospitals and grocery stores during a disaster. This analysis explicitly considers equity to understand differences in current resilience and resilience strategies to effectively improve critical services access for all Angelenos. Research was guided by input from the community engagement process, and associated equity strategies are presented in alignment with that guidance.

14 SOLAR ENERGY↗

Unleashing the Frequency: Multi-Megawatt Demonstration of 100% Renewable Power Systems with Decentralized Communication-Less Control Scheme

Power systems, which range in size from small microgrids to island systems to large regional grids, are typically managed by a central controller that requires complex communication methods and can be unreliable and pose cyber security risks in certain applications, especially when controlling a larger number of nodes. We propose an inherently robust, scalable method of integration using multiple energy storage systems and distributed energy resources, which does not require any means of dedicated communication. This method moves beyond the paradigm of controlling grid frequency at a fixed value (e.g., 60 Hz), instead allowing the frequency to fluctuate within certain limits (e.g., 59.6-60.4 Hz). With a greater operating range, the frequency can carry necessary information from energy storage systems to highly variable distributed energy resources like photovoltaics, wind, hydro, etc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On the impact of tidal generation and energy storage integration in PV-rich electric distribution systems

Deep decarbonization of power system operations requires the maximal utilization of available renewable resources. At distribution-level operations, however, grid operators can face numerous challenges in integrating renewables at scale owing to the inherent intermittence of renewable energy resources. These include phenomena such as voltage fluctuations, which are typically mitigated through control actuators such as on-load tap changers (OLTC) as well as energy storage devices, such as battery energy storage systems (BESS). On the one hand, high intermittence of the available renewable portfolio may require increasingly aggressive control of actuators, thereby accelerating the probability of equipment failure. On the other hand, integrating BESS operations and having a diverse renewable generation portfolio can typically help stagger power/energy flow to mitigate the aforementioned adverse impacts. In this paper, we employ a Bayesian framework for equipment lifetime estimation to understand the impact of including tidal energy resources and BESS in distribution system operations for feeders having substantial distribution photovoltaic generation. Our results indicate that while tidal energy alone may slightly decrease equipment reliability, the adverse impact on reliability is significantly magnified by a generation portfolio consisting of tidal generation and photovoltaic generation. Here, we also study the tidal and photovoltaic hosting capacity problem with and without energy storage systems using equipment reliability as an added constraint. We conclude that energy storage increases the reliability-constrained hosting capacity of the distribution system.

14 SOLAR ENERGY↗

Distributed Optimal Power Management for Battery Energy Storage Systems: A Novel Accelerated Tracking ADMM Approach

Optimal power management (OPM) is critical for large-scale battery energy storage systems. Today’s methods often require formidable computational effort due to the design based on centralized numerical optimization. Thus, this paper investigates computationally distributed OPM where the agents based on the cells communicate over a network to cooperatively solve the OPM problem. We propose an accelerated tracking alternating direction method of multipliers (ADMM) algorithm to solve the distributed OPM. The proposed algorithm embeds dynamic average consensus and Nesterov’s acceleration technique in the ADMM algorithm. Not only is the proposed algorithm fully distributed without a need for fusion or aggregating nodes, but it also accelerates convergence. The paper formulates the OPM in a model predictive control framework where it seeks to regulate the charging/discharging power of each battery cell to minimize the total power losses and promote balanced use of the constituent cells while complying with the safety constraints. The paper provides ample simulation results to demonstrate the effectiveness and advantages of the proposed distributed OPM in terms of computation and convergence.

Farakhor, Amir↗

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS-based on real-time optimal power flow-controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimal Energy Storage Schedules for Load Leveling and Ramp Rate Control in Distribution Systems

Continued integration of distributed energy resources (DERs) into the grid, such as solar PVs, at a large-scale, contributes into the famous Duck Curve. New DER management algorithms are therefore deemed necessary to alleviate rapid variations within net load profiles of distribution systems. Herein this paper proposes a process to determine the optimal energy storage schedules for leveling the distribution circuit feederhead net load. A series of sensitivity analyses shows how the proposed method can be used to determine the optimal energy storage schedules with different capacities, state of charge requirements, and net load ramp rate limitations.

25 ENERGY STORAGE↗

An exploration of how the geographic distribution of power sources impacts power system resilience

The purpose of this paper is to qualitatively explore the question of whether as a power system’s sources and energy storage become more distributed, the power system also tends to become more resilient. The paper is divided into two main parts. After presenting introductory material, Part 1 looks at factors that might limit the ability of ‘fully-distributed’ resources to provide the expected resilience, and Part 2 considers factors that might make a more centralized system more resilient.

25 ENERGY STORAGE↗

Energy 101: Distributed Energy Resources and Controllable Loads [Slides]

The Energy 101: Distributed Energy Resources and Storage presentation, developed for the Energy Technology Innovation Partnership Project (ETIPP), provides an overview of distributed energy resources (DERs) and energy storage. It covers fundamental concepts, technologies, considerations, case studies, and additional resources.

14 SOLAR ENERGY↗

Offshore CO2 Saline Storage Calculator

The Offshore CO2 Saline Storage Calculator is a data-driven tool that applies the adapted DOE CO2 Methodology to calculate all potential distributions of offshore storage efficiency and resource potential at multiple spatial scales for saline formations. The tailored methodology include accounting for changing CO2 density with the overlying water column and sediment differences in unlithified, porous, and permeable offshore saline formations. The latest release of the tool and a tutorial are available in the tools public GitHub repository. We recommend testing out this application using data from the Petrophysical Well Log Interpretation Dataset, which spans the northern Gulf of Mexico and is available on EDX here: https://edx.netl.doe.gov/dataset/petrophysical-well-log-interpretation-dataset

calculator↗

Resonant anomalous X-ray reflectivity for revealing ion distributions near electrodes

Energy storage devices–batteries, for example–consist of an electrolyte sandwiched between two charged electrodes through which current can pass. The metal ion organization at the electrode–electrolyte interface, commonly referred to as the electric double layer, determines the efficiency and stability of the device. There are two major challenges with experimentally characterizing the metal ion distribution at the interface.

42 ENGINEERING↗

Matrix Diffusion Controls Mountain Hillslope Groundwater Ages and Inferred Storage Dynamics

Groundwater age distributions provide fundamental insights on coupled water and biogeochemical processes in mountain watersheds. Field-based studies have found mixtures of young and old-aged groundwater in mountain catchments underlain by bedrock; yet, the processes that dictate these groundwater age distributions are poorly understood. In this work, we use the coupled ParFlow-CLM integrated hydrologic and EcoSLIM particle tracking models to simulate groundwater age distributions on a lower montane hillslope in the East River Watershed, Colorado (USA). We develop a convolution-based approach to propagate fracture-matrix diffusion processes to the EcoSLIM advection-dominated age distributions. We compare observed 3 H and 4 He concentrations from two groundwater wells against model predictions that have varying advective transport times and matrix diffusion magnitudes. Based on a Monte Carlo analysis that considers uncertain matrix and fracture parameters, we find that matrix diffusion is needed to jointly predict 3 H and 4 He observations at both wells. The advection-dominated age distributions lack adequate mixing of young and old-aged water to capture the observed co-occurrence of 3 H and 4 He. The model scenario that best matches the 3 H, 4 He, and water level observations when considering both advective flowpath and matrix diffusion mixing processes has a dynamic bedrock groundwater reservoir that is susceptible to considerable storage losses during low-snow periods. This dynamic groundwater system amplifies the need to assimilate deeper bedrock groundwater into watershed hydro-biogeochemical predictions. This work further highlights the importance of considering matrix diffusion when interpreting environmental tracers in bedrock groundwater systems.

54 ENVIRONMENTAL SCIENCES↗

Mudstone Baffles and Barriers in Lower Cretaceous Strata at a Proposed CO 2 Storage Hub in Kemper County, Mississippi, United States

The Cretaceous and Tertiary deposits in Mississippi, Alabama, and the adjacent continental shelf constitute a widespread succession of sandstone, mudstone, and carbonate that has proven to be an important target for geologic CO 2 storage in the onshore Gulf of Mexico basin. Integrated analysis of stratigraphy, sedimentology, and reservoir properties based on cores and geophysical well logs indicates that the Paluxy Formation and Washita- Fredericksburg interval present gigatonne-class storage opportunities. The distribution, geometry, and composition of the area is a direct reflection of the original depositional environments, and understanding these factors is essential for understanding the geologic storage potential of the Paluxy Formation and Washita-Fredericksburg interval at the Kemper County energy facility in Mississippi. Geologic characterization of the Mississippi Embayment at the energy facility focused primarily on characterizing the confinement potential of the storage complex. Integration of core analyses and geophysical well logs has yielded a high-resolution stratigraphic analysis of storage reservoirs, baffles, barriers, and seals. Scanning electron microscopy (SEM) coupled with energy dispersive X-ray spectroscopy (EDS), and quantitative X-ray diffraction (XRD) was used to characterize microfabric, pore types, and mineralogy within mudstone of the east-central Mississippi Embayment at the Kemper County energy facility. Mudstone beds in the Paluxy Formation and Washita-Fredericksburg interval have variable thickness and continuity. High water saturation in the Cretaceous mudstone units influences swelling smectite clay and mudrock permeability based on pulse decay analysis is 1–96 nD. These low permeability values indicate that the mudstone units are effective baffles, barriers, and confining intervals that make significant migration of injected CO 2 out of the storage complex unlikely. The numerous baffles and barriers within the target reservoir intervals, moreover, favor the retention of multiple CO 2 in plumes within the abundant stacked sandstone bodies.

03 NATURAL GAS↗

DistOPF: Advanced Solutions for Distribution Optimal Power Flow Analysis - DistOPF v0.2 Documentation

To achieve an affordable and reliable energy system, research on power distribution system is often focused on integration of distributed generators, energy storage solution, EV charging, smart meters, and other advanced assets that may benefit from or require more advanced control and optimization techniques. Despite this focus on advanced distribution system topics, early researchers and grid scientists often start from scratch when developing optimization programs for power distribution systems. This report introduces DistOPF, a Python package that consolidates years of research into a versatile and modular tool. DistOPF provides researchers with essential capabilities to solve distribution system Optimal Power Flow (OPF) problems using standard network models. Additionally, it offers a platform to benchmark both new and existing algorithms against established test systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Net-zero Microgrid Program Report: Microrred de la Montaña Feasibility Study (Executive Summary Extended)

This feasibility study provides the technical and economic rationale for the Microrred de la Montaña as a viable solution for supplying reliable and resilient electricity to an underserved region in Puerto Rico – a region that is the first to be disconnected from the grid and the last to be restored, enduring months long outages. It begins the process of the development of the microgrid through conceptual design, engineering, detailed electrical design, implementation, and operation. The Microrred de la Montaña is organized under the governance of the Cooperativa Hidroeléctrica de la Montaña (Cooperativa) which has legal status as a cooperative and power provider under the laws of Puerto Rico. The members are the municipalities of Adjuntas, Jayuya, Lares and Utuado with a combined population of 90,000. These municipalities are in central Puerto Rico – a mountainous region that is extremely vulnerable to weather events and excessive, long-duration power outages and are among the poorest and most disadvantaged regions in Puerto Rico. Funding from external sources is necessary to acquire the resources for a resilient power delivery system. Regulatory support is necessary to establish operational relationships with the incumbent power providers. The Microrred de la Montaña is envisioned as a resilient microgrid that manages distributed energy resources – local solar, storage, and hydroelectricity over an upgraded distribution network within the boundaries of four municipalities. This feasibility study provides the results of an extensive techno-economic analysis to form a sound basis for decision-making by community leaders, their constituents, funding and investment agencies, and regulators to realize the benefits that are achievable by fully implementing the design and planning recommended for the Microrred de la Montaña.

13 HYDRO ENERGY↗

Accurate and Rapid Forecasts for Geologic Carbon Storage via Learning-Based Inversion-Free Prediction

Carbon capture and storage (CCS) is one approach being studied by the U.S. Department of Energy to help mitigate global warming. The process involves capturing CO 2 emissions from industrial sources and permanently storing them in deep geologic formations (storage reservoirs). However, CCS projects generally target “green field sites,” where there is often little characterization data and therefore large uncertainty about the petrophysical properties and other geologic attributes of the storage reservoir. Consequently, ensemble-based approaches are often used to forecast multiple realizations prior to CO 2 injection to visualize a range of potential outcomes. In addition, monitoring data during injection operations are used to update the pre-injection forecasts and thereby improve agreement between forecasted and observed behavior. Thus, a system for generating accurate, timely forecasts of pressure buildup and CO 2 movement and distribution within the storage reservoir and for updating those forecasts via monitoring measurements becomes crucial. This study proposes a learning-based prediction method that can accurately and rapidly forecast spatial distribution of CO 2 concentration and pressure with uncertainty quantification without relying on traditional inverse modeling. The machine learning techniques include dimension reduction, multivariate data analysis, and Bayesian learning. The outcome is expected to provide CO 2 storage site operators with an effective tool for timely and informative decision making based on limited simulation and monitoring data.

58 GEOSCIENCES↗

Market-based Co-optimization of Energy and Ancillary Services with Distributed Energy Resource Flexibilities

Energy storage systems and flexible loads have attracted significant interests due to their capabilities to provide various grid services. In this paper, the flexibilities are optimally allocated among multiple distributed energy resource aggregators with energy storage systems and flexible buildings by the utility coordinator through market-based co-optimization. An iterative market clearing algorithm is developed to determine the optimal energy and ancillary service prices, with consideration of both local dynamics and network constraints. Simulation results demonstrate the effectiveness of the proposed algorithm and the benefits of co-optimizing the energy and ancillary service markets.

Ma, Ke↗

FY 2021 Isolated Grids and Grid-Connected Turbine Reference Systems; Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

For individuals, businesses, and communities focused on building resilient electrical grid infrastructure, wind energy can provide an affordable, accessible, and compatible distributed energy resource option that also enhances the capabilities of local grid operations. The Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) project is a multi-year distributed wind research effort, driven through a partnership between four Department of Energy National Laboratories and industry to develop and improve the planning, design, and operation of wind-centered microgrids to complement solar, energy storage, and other distributed energy resources for grid-tied and isolated operation (U.S. Department of Energy, 2021). This report documents the application of methods developed through the initial three years of the MIRACL project to two real-world distributed wind reference systems. Specifically, the methods demonstrated in this report include 1) a market valuation framework to comprehensively value the services distributed wind can provide and 2) a resilience framework that enables stakeholders to characterize distribution system resilience and compare grid investment decisions from a resilience perspective. Additional methods mentioned in this report include distributed hybrid system design methods for grid resilience, advanced control co-simulation platforms, and power hardware-in-the-loop (PHIL) models. Preliminary results from these additional methods are presented in this report and will be demonstrated and/or applied to the reference systems in the coming year. The purpose of applying these methods to reference systems is to drive technology transfer of the theories, methodologies, and technologies developed under the MIRACL project and increase the number of referenceable case studies available to stakeholders interested in additional value-added capabilities of wind systems beyond bulk energy supply (i.e. kilowatt-hours).

17 WIND ENERGY↗

Impacts of Mixed-Wettability on Brine Drainage and Supercritical CO 2 Storage Efficiency in a 2.5-D Heterogeneous Micromodel

Geological carbon storage (GCS) involves unstable drainage processes, the formation of patterns in a morphologically unstable interface between two fluids in a porous medium during drainage. The unstable drainage processes affect CO 2 storage efficiency and plume distribution and can be greatly complicated by the mixed-wet nature of rock surfaces common in hydrocarbon reservoirs where supercritical CO 2 (scCO 2 ) is used in enhanced oil recovery. Here, we performed scCO 2 injection (brine drainage) experiments at 8.5 MPa and 45°C in heterogeneous micromodels, two mixed-wet with varying water- and intermediate-wet patches, and one water-wet. The flow regime changes from capillary fingering through crossover to viscous fingering in the micromodels of the same pore geometry but different wetting surfaces at displacement rates with logCa (capillary number) increasing from –8.1 to –4.4. While the mixed-wet micromodel with uniformly distributed intermediate-wet patches yields ~0.15 scCO 2 saturation increase at both capillary fingering and crossover flow regimes (–8.1 ≤ logCa ≤ –6.1), the one heterogeneous wetting to scCO 2 results in ~0.09 saturation increase only at the crossover flow regime (–7.1 ≤ logCa ≤ –6.1). The interconnected flow paths in the former are quantified and compared to the channelized scCO 2 flow through intermediate-wet patches in the latter by topological analysis. At logCa > –6.1 (near well), the effects of wettability and pore geometry are suppressed by strong viscous force. Both scCO 2 saturation and distribution suggest the importance of wettability on CO 2 storage efficiency and plume shape in reservoirs and capillary leakage through caprock at GCS conditions.

58 GEOSCIENCES↗