Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed state estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

GenAI4UQ: A software for forward and inverse uncertainty quantification using conditional generative AI

We introduce GenAI4UQ, a software package for forward and inverse uncertainty quantification in model calibration, parameter estimation, and ensemble forecasting. GenAI4UQ leverages a generative AI-based conditional modeling framework to address limitations of traditional inverse modeling techniques, such as Markov Chain Monte Carlo (MCMC) methods. By replacing computationally intensive iterative processes with a direct, learned mapping, GenAI4UQ enables efficient calibration of input parameters and generation of predictions directly from observations. The software supports rapid ensemble forecasting with robust uncertainty quantification while maintaining computational and storage efficiency. Built-in auto-tuning of hyperparameters simplifies model training, ensuring accessibility for users with varying expertise. Its versatile conditional generative framework is applicable across diverse scientific domains. While GenAI4UQ offers significant advantages in flexibility and efficiency, users should interpret its uncertainty estimates with caution in data-sparse scenarios, as the model may overestimate uncertainty—an effect common to all surrogate-based approaches including MCMC with surrogate models. Despite this, GenAI4UQ transforms inverse modeling by providing a fast, reliable, and user-friendly solution. It empowers researchers and practitioners to quickly estimate parameter distributions and generate model predictions for new observations, facilitating efficient decision-making and advancing the state of uncertainty quantification in computational modeling.

97 MATHEMATICS AND COMPUTING↗

High Impedance Fault Detection Through Quasi-Static State Estimation: A Parameter Error Modeling Approach

This paper presents a model for detecting high impedance faults using parameter error modeling and a two step per-phase weighted-least squares state estimation process. The proposed scheme leverages the use of Phasor Measurement Units and synthetic measurements to identify per-phase power flow and injection measurements which indicate a parameter error through ?2 Hypothesis Testing applied to the composed measurement error. Although current and voltage waveforms are commonly analyzed for high-impedance fault detection, wide area power flow and injection measurements, which are already inherent to the state estimation process, also show promise for real-world high-impedance fault detection applications. The error distributions after detection share the measurement function error spread observed in proven parameter error diagnostics and can be applied to high-impedance fault identification. Further, this error spread across measurement functions related to the fault will be clearly discerned from measurement error. Case studies are performed on the IEEE 33-Bus Distribution System along with the proposed model in Simulink.

Cooper, Austin↗

Distributed Generation Market Demand (dGen) model

The Distributed Generation Market Demand (dGen) model simulates customer adoption of distributed energy resources (DERs) for residential, commercial, and industrial entities in the United States or other countries through 2050. The dGen model can be used for identifying the sectors, locations, and customers for whom adopting DERs would have a high economic value, for generating forecasts as an input to estimate distribution hosting capacity analysis, integrated resource planning, and load forecasting, and for understanding the economic or policy conditions in which DER adoption becomes viable, and for illustrating sensitivity to market and policy changes such as retail electricity rate structures, net energy metering, and technology costs.

Array↗

Nearly optimal state preparation for quantum simulations of lattice gauge theories

Here, we present several improvements to the recently developed ground-state preparation algorithm based on the quantum eigenvalue transformation for unitary matrices (QETU), apply this algorithm to a lattice formulation of U(1) gauge theory in (2+1) dimensions, as well as propose an alternative application of QETU, a highly efficient preparation of Gaussian distributions. The QETU technique was originally proposed as an algorithm for nearly optimal ground-state preparation and ground-state energy estimation on early fault-tolerant devices. It uses the time-evolution input model, which can potentially overcome the large overall prefactor in the asymptotic gate cost arising in similar algorithms based on the Hamiltonian input model. We present modifications to the original QETU algorithm that significantly reduce the cost for the cases of both exact and Trotterized implementation of the time evolution circuit. We use QETU to prepare the ground state of a U(1) lattice gauge theory in two spatial dimensions, explore the dependence of computational resources on the desired precision and system parameters, and discuss the applicability of our results to general lattice gauge theories. We also demonstrate how the QETU technique can be utilized for preparing Gaussian distributions and wave packets in a way which outperforms existing algorithms for as little as n q ≳ 2–5 qubits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Distributed Wind Development Potential at United States Correctional Facilities

The goal of this assessment was to provide a high-level overview of distributed wind development potential at correctional facilities across the United States. The assessment considered the wind resource, electricity rates, and electricity consumption at facilities. In total, Pacific Northwest National Laboratory (PNNL) estimates that 2,421 facilities in 1,280 counties, projected to consume a combined 12,000 GWh/year, have the potential to host distributed wind projects.

17 WIND ENERGY↗

Voltage Estimation in Low-Voltage Distribution Grids with Distributed Energy Resources

Present distribution grids generally have limited sensing capabilities and are therefore characterized by low observability. Improved observability is a prerequisite for increasing the hosting capacity of distributed energy resources such as solar photovoltaics (PV) in distribution grids. In this context, this paper presents learning-aided low-voltage estimation using untapped but readily available and widely distributed sensors from cable television (CATV) networks. The cable broadband sensors offer timely local voltage magnitude sensing with 5-minute resolution and can provide an order of magnitude more data on the time-varying state of a secondary distribution system than currently deployed utility sensors. The proposed solution incorporates voltage readings from neighboring CATV sensors, taking into account spatio-temporal aspects of the observations, and estimates single-phase voltage magnitudes at all non-monitored low-voltage buses using random forests. The effectiveness of the proposed approach was demonstrated using a multi-phase 1572-bus feeder from the SMART-DS data set for two case studies passive distribution feeder (without PV) and active distribution feeder (with PV). The analysis was conducted on simulated data, and the results show voltage estimates with a high degree of accuracy, even at extremely low percentages of observable nodes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Prompt and non-prompt J/ψ production cross sections at midrapidity in proton-proton collisions at $ \sqrt{\mathrm{s}} $ = 5.02 and 13 TeV

The production of J /ψ is measured at midrapidity ( |y| < 0 . 9) in proton-proton collisions at \( \sqrt{s} \) = 5 . 02 and 13 TeV, through the dielectron decay channel, using the ALICE detector at the Large Hadron Collider. The data sets used for the analyses correspond to integrated luminosities of \( \mathcal{L} \) int = 19.4 ± 0.4 nb - 1 and \( \mathcal{L} \) int = 32.2 ± 0.5 nb - 1 at \( \sqrt{s} \) = 5 . 02 and 13 TeV, respectively. The fraction of non-prompt J /ψ mesons, i.e. those originating from the decay of beauty hadrons, is measured down to a transverse momentum p T = 2 GeV /c (1 GeV /c ) at \( \sqrt{s} \) = 5 . 02 TeV (13 TeV). The p T and rapidity ( y ) differential cross sections, as well as the corresponding values integrated over p T and y , are carried out separately for prompt and non-prompt J /ψ mesons. The results are compared with measurements from other experiments and theoretical calculations based on quantum chromodynamics (QCD). The shapes of the p T and y distributions of beauty quarks predicted by state-of-the-art perturbative QCD models are used to extrapolate an estimate of the \( \mathrm{b}\overline{\mathrm{b}} \) pair cross section at midrapidity and in the total phase space. The total \( \mathrm{b}\overline{\mathrm{b}} \) cross sections are found to be \( {\sigma}_{\mathrm{b}\overline{\mathrm{b}}} \) = 541 ± 45 (stat . ) ± 69 \( {\left(\mathrm{syst}.\right)}_{-12}^{+10} \) (extr . ) μ b and \( {\sigma}_{\mathrm{b}\overline{\mathrm{b}}} \) = 218 ± 37 (stat . ) ± 31 \( {\left(\mathrm{syst}.\right)}_{-9.1}^{+8.2} \) (extr . ) μ b at \( \sqrt{s} \) = 13 and 5.02 TeV, respectively. The value obtained from the combination of ALICE and LHCb measurements in pp collisions at \( \sqrt{s} \) = 13 TeV is also provided.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Artificial Neural Network-based State Estimation for Low Observable, Unbalanced Microgrids for Microgrid Building Blocks

The microgrid building blocks (MBB) were proposed as microgrid components with combined sub-components with power conversion, communication, and microgrid control capability, or a subset of such sub-components. This work addresses the microgrid controller, present in an MBB, which requires accurate state estimation to perform its tasks, including for monitoring, power flow (dispatch), fault detection, etc. In this paper, an artificial neural network (ANN)-based framework for state estimation is proposed for an MBB, especially for unbalanced and low observable microgrids. To overcome the challenge of low observability in unbalanced systems, a concept of extended adjacent matrix is introduced to reduce the required number of measurements for state estimation. Addressing the challenges, a feed forward neural network (FNN) is utilized to enhance estimation accuracy and reliability with the reduced number of measurements. The proposed state estimation is validated through extensive simulations on a microgrid, which was achieved from the modified IEEE 34-bus distribution test feeder with multiple distributed energy resources (DERs) and demonstrated superior performance in estimation accuracy and low observability.

Choi, Jongchan↗

2021 Cost of Wind Energy Review [Slides]

This analysis uses representative utility-scale and distributed wind energy projects to estimate the levelized cost of energy (LCOE) for land-based, offshore, and distributed wind power in the United States. Data and results detailed here are derived from 2021 commissioned plants and representative industry data as well as state-of-the-art modeling capabilities. Modeling is conducted to provide more granular detail on specific cost categories. This study represents the 11th annual installment and is intended to provide insight into current component-level costs as well as a basis for understanding variability in wind energy LCOE across the country.

17 WIND ENERGY↗

Voltage Stability Constrained Moving Target Defense Against Net Load Redistribution Attacks

Moving target defense (MTD) using distributed flexible AC transmission system (D-FACTS) devices is a promising defense strategy to detect stealthy false data injection (FDI) attacks against the power system state estimation. However, all existing studies myopically perturb the reactance of D-FACTS lines without considering the system voltage stability. In this paper, we first illustrate voltage instability induced by MTDs in a three-bus system. To address this issue, we further propose a novel MTD framework that explicitly considers system voltage stability by using continuation power flow and voltage stability indices. We mathematically derive the sensitivity matrix of voltage stability index to line impedance, on which an optimization problem for maximizing voltage stability index is formulated. This framework is tested on the IEEE 14-bus and the IEEE 118-bus transmission systems, in which net load redistribution attacks are launched by sophisticated attackers. Here, the simulation results show the effectiveness of the proposed framework in circumventing the voltage instability while maintaining the detection effectiveness of MTD. We conduct case studies with and without the proposed framework under different MTD planning and operational methods. The impacts of the proposed two methods on attack detection effectiveness and system economic metrics are also revealed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Physics-Based Digital Twin for Wave Elevation and Seabed Moment Estimation of Offshore Monopiles: Preprint

In this work, we present a proof of concept of a physics-based digital twin for a monopile structure (with overhead inertia) subjected to wave loading. The digital twin is formulated using reduced-order models derived from first principles and combined with a Kalman filter for state estimation. The proposed framework estimates the monopile top motion, the wave elevation, and the section forces and moments along the pile using primarily acceleration measurements at the monopile top. Key innovations include the use of a hydrodynamic shape function to represent distributed wave loading in a compact and computationally efficient manner, and the introduction of a shaping filter to augment the state-space with wave kinematics. Synthetic measurement data are generated using OpenFAST and used as a reference to assess the performance of the digital twin. Results demonstrate that the wave elevation can be accurately reconstructed without direct sea-state measurements as long as the wave regime is inertia-dominated. Under the ideal tested conditions, the total hydrodynamic force and sea-bed bending moment are estimated with relative errors on the order of 1% and correlation coefficients exceeding 96%. Future work will evaluate the estimator's performance under operational uncertainties and more complex loading conditions.

17 WIND ENERGY↗

Evaluating the potential of short-term instrument deployment to improve distributed wind resource assessment

Distributed wind projects, which are connected at the distribution level of an electricity system or in off-grid applications to serve specific or local energy needs, often rely solely on wind resource models to establish wind speed and energy generation expectations. Historically, anemometer loan programs have provided an affordable avenue for more accurate onsite wind resource assessment, and the lowering cost of lidar systems has shown similar advantages for more recent assessments. While a full 12 months of onsite wind measurement is the standard for correcting model-based long-term wind speed estimates for utility-scale wind farms, the time and capital investment involved in gathering onsite measurements must be reconciled with the energy needs and funding opportunities that drive expedient deployment of distributed wind projects. Much literature exists to quantify the performance of correcting long-term wind speed estimates with 1 or more years of observational data, but few studies explore the impacts of correcting with months-long observational periods. This study aims to answer the question of how short you can go in terms of the observational time period needed to make impactful improvements to model-based long-term wind speed estimates. Three algorithms, multivariable linear regression, adaptive regression splines, and regression trees, are evaluated for their skill at correcting long-term wind resource estimates from the European Centre for Medium-Range Weather Forecasts Reanalysis version 5 (ERA5) using months-long periods of observational data from 66 locations across the US. On average, correction with even 1 month of observations provides significant improvement over the baseline ERA5 wind speed estimates and produces median bias magnitudes and relative errors within 0.22 m s −1 and 4 percentage points of the median bias magnitudes and relative errors achieved using the standard 12 months of data for correction. However, in cases when the shortest observational periods (1 to 2 months) used for correction are not well correlated with the overlapping ERA5 reference, the resultant long-term wind speed errors are worse than those produced using ERA5 without correction. Summer months, which are characterized by weaker relative wind speeds and standard deviations for most of the evaluation sites, tend to produce the worst results for long-term correction using months-long observations. The three tested algorithms perform similarly for long-term wind speed bias; however, regression trees perform notably worse than multivariable linear regression and adaptive regression splines in terms of correlation when using 6 months or less of observational data for correction. Translating the analysis to wind energy, median relative errors in the capacity factor are on average within 10 % using 1 month of training. If the observation period used for correction is not well correlated with the reference data, however, misrepresentation of the observed capacity factor can be substantial. The risk associated with poor correlation between the observed and reference datasets decreases with increasing training period length. In the worst-correlation scenarios, the median capacity factor relative errors from using 1, 3, and 6 months are within 47 %, 26 %, and 16 %, respectively.

17 WIND ENERGY↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops an approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurements. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops a machine learning based approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurement. The machine learning model is developed by using random forest algorithm. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

advanced metering infrastructure↗

Locational Value of Distributed Energy Resources

This report focuses on potential DER benefits for distribution systems, primarily in their role as non-wires alternatives to defer, mitigate, or eliminate the need for some traditional system investments at locations where distribution capacity is insufficient to meet expected future needs. It describes approaches and tools to estimate the locational value of DERs. The report includes 24 case studies to illustrate how states and utilities are considering the locational value of DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Maximum Likelihood Estimation: Some Basics

The maximum likelihood estimation is a general estimation procedure. It is often compared to estimation procedures like the ordinary least squares regression or generalized method of moments, to name a few. We discuss some basics about the maximum likelihood estimation, its advantages and disadvantages, and provide an example application to a gamma distribution function.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of a Systematic and Extensible Force Field for Peptoids (STEPs)

Peptoids (N-substituted glycines) are a class of biomimetic polymers that have attracted significant attention due to their accessible synthesis and enzymatic and thermal stability relative to their naturally occurring counterparts (polypeptides). While these polymers provide the promise of more robust functional materials via hierarchical approaches, they present a new challenge for computational structure prediction for material design. The reliability of calculations hinges on the accuracy of interactions represented in the force field used to model peptoids. For proteins, structure prediction based on sequence and de novo design has made dramatic progress in recent years; however, these models are not readily transferable for peptoids. Current efforts to develop and implement peptoid-specific force fields are spread out, leading to replicated efforts and a fragmented collection of parameterized sidechains. Here, we developed a peptoid-specific force field containing 70 different side chains, using GAFF2 as starting point. The new model is validated based on the generation of Ramachandran-like plots from DFT optimization compared against force field reproduced potential energy and free energy surfaces as well as the reproduction of equilibrium cis/trans values for some residues experimentally known to form helical structures. In conclusion, equilibrium cis/trans distributions (Kct) are estimated for all parameterized residues to identify which residues have an intrinsic propensity for cis or trans states in the monomeric state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements: Preprint

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops an approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurements. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗