Radar altimeter and Doppler velocity sensor, frequency discriminator analysis
Surveyor radar and Doppler velocity sensor frequency discriminator analysis for Gaussian signal and noise condition
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Surveyor radar and Doppler velocity sensor frequency discriminator analysis for Gaussian signal and noise condition
Design, construction, and testing of photomultiplier tube amplifier-discriminator system
Frequency shift keyed /FSK/ digital signal detection using FM discriminators, predicting error rates for several sequences
Circuit for discriminating neutrons, gammas and charged particles from each other in phoswich scintillator
Discriminator threshold and SNR above threshold response when demodulating FM signal undergoing selective fading
Frequency shift keyed /FSK/ digital signal detection using FM discriminators, predicting error rates for several sequences
Associative recall in verbal-discrimination learning as related to pronunciation and degree of practice
Discrimination of visual stimulus duration by pigeons
It has long been known that ocular pursuit of a moving target has a major influence on its perceived speed (Aubert, 1886; Fleischl, 1882). However, little is known about the effect of smooth pursuit on the perception of target direction. Here we compare the precision of human visual-direction judgments under two oculomotor conditions (pursuit vs. fixation). We also examine the impact of stimulus duration (200 ms vs. ~800 ms) and absolute direction (cardinal vs. oblique). Our main finding is that direction discrimination thresholds in the fixation and pursuit conditions are indistinguishable. Furthermore, the two oculomotor conditions showed oblique effects of similar magnitudes. These data suggest that the neural direction signals supporting perception are the same with or without pursuit, despite remarkably different retinal stimulation. During fixation, the stimulus information is restricted to large, purely peripheral retinal motion, while during steady-state pursuit, the stimulus information consists of small, unreliable foveal retinal motion and a large efference-copy signal. A parsimonious explanation of our findings is that the signal limiting the precision of direction judgments is a neural estimate of target motion in head-centered (or world-centered) coordinates (i.e., a combined retinal and eye motion signal) as found in the medial superior temporal area (MST), and not simply an estimate of retinal motion as found in the middle temporal area (MT).
Several discriminability measures were examined for their ability to predict reading search times for three levels of text contrast and a range of backgrounds (plain, a periodic texture, and four spatial-frequency-filtered textures created from the periodic texture). Search times indicate that these background variations only affect readability when the text contrast is low, and that spatial frequency content of the background affects readability. These results were not well predicted by the single variables of text contrast (Spearman rank correlation = -0.64) and background RMS contrast (0.08), but a global masking index and a spatial-frequency-selective masking index led to better predictions (-0.84 and -0.81, respectively). c2000 Optical Society of America.
By means of a two-interval forced-choice procedure, contrast detection thresholds for an aircraft positioned on a simulated airport runway scene were measured with fixed and random white-noise masks. The term fixed noise refers to a constant, or unchanging, noise pattern for each stimulus presentation. The random noise was either the same or different in the two intervals. Contrary to simple image discrimination model predictions, the same random noise condition produced greater masking than the fixed noise. This suggests that observers seem unable to hold a new noisy image for comparison. Also, performance appeared limited by internal process variability rather than by external noise variability, since similar masking was obtained for both random noise types.
Several spaceborne scatterometer missions have been successfully flown in the past decade. In this paper, the application of simultaneous range/Doppler discrimination techniques are proposed as way of improving the single-pass resolution of conically scaning pencil-beam scatterometer systems.
The opioid overdose crisis is a global health challenge. Fentanyl, an exceedingly potent synthetic opioid, has emerged as a leading contributor to the surge in opioid-related overdose deaths. The surge in overdose fatalities, particularly due to illicitly manufactured fentanyl and its contamination of street drugs, emphasizes the urgency for drug-testing technologies that can quickly and accurately identify fentanyl from other drugs and quantify trace amounts of fentanyl. In this paper, gold nanoparticle (AuNP)-decorated single-walled carbon nanotube (SWCNT)-based field-effect transistors (FETs) are utilized for machine learning-assisted identification of fentanyl from codeine, hydrocodone, and morphine. The unique sensing performance of fentanyl led to use machine learning approaches for accurate identification of fentanyl. Employing linear discriminant analysis (LDA) with a leave-one-out cross-validation approach, a validation accuracy of 91.2% is achieved. Meanwhile, density functional theory (DFT) calculations reveal the factors that contributed to the enhanced sensitivity of the Au-SWCNT FET sensor toward fentanyl as well as the underlying sensing mechanism. Finally, fentanyl antibodies are introduced to the Au-SWCNT FET sensor as specific receptors, expanding the linear range of the sensor in the lower concentration range, and enabling ultrasensitive detection of fentanyl with a limit of detection at 10.8 fg mL –1 .
Plastic scintillators, a class of solid-state materials used for radiation detection, were additively manufactured with vat photopolymerization. The photopolymer resins consisted of a primary dopant and a secondary dopant dissolved in a bisphenol A ethoxylate diacrylate-based matrix. The absorptive dopants significantly influence important print parameters, for example, secondary dopants decrease the light penetration depth by a factor > 12×. The primary dopant 2,5-diphenyloxazole had minimal impact on the printing process even when loaded at 25 % by mass of the resin. Working curve measurements, which relate energy dose to cure depth, were performed as a function of feature size to further assess the influence of dopants. Photopatterns smaller than 150 µm width had apparent increases in critical energy dose compared to larger photopatterns, while all resins maintained printed features in line gratings with 50 µm of separation. Printed scintillator monoliths were compared to scintillators cast by traditional molding, demonstrating that the layer-by-layer printing process does not decrease scintillation response. In conclusion, a maximum light output of 31 % of a benchmark plastic scintillator (EJ-200) and successful pulse shape discrimination were achieved with 20 % by mass 2,5-diphenyloxazole as the primary dopant and 0.1 % by mass 9,9-dimethyl-2,7-distyrylfluorene as the secondary dopant in printed scintillator samples.
Perchlorate (ClO 4 - ) has synthetic and natural sources. Synthetic ClO 4 - is released to the environment from its use as an oxidant in military and aerospace applications, and from its presence in a variety of common commercial products, such as safety flares, chlorate herbicides, and fireworks. Natural sources of ClO 4 - in the environment include imported nitrate fertilizers derived from salt deposits in the Atacama Desert of Chile and indigenous natural ClO 4 - that accumulates in unsaturated soils and groundwaters in other arid and semi-arid environments, largely from atmospheric deposition. The stable isotope ratios of chlorine ( 37 Cl/ 35 Cl) and oxygen ( 18 O/ 16 O, 17 O/ 16 O) and the isotopic abundance of radioactive 36 Cl in ClO 4 - can be used to discriminate these different sources. Perchlorate was previously detected at relatively high concentrations (3.8–34.7 μg/L) in groundwater from many wells in the Boardman-Umatilla area near the Columbia River in northeastern Oregon, which is a semi-arid, highly agricultural, heavily irrigated area that includes several past and current military installations. Eight representative groundwater wells were sampled throughout this region and isotopic characteristics of ClO 4 - collected from each well were measured along with other chemical and isotopic parameters including tritium and other groundwater age indicators. We report isotopic data indicate that indigenous natural ClO 4 - was present in groundwater from all sampled wells and was the predominant source in five of the wells. Synthetic ClO 4 - was present in the three remaining wells with natural ClO 4 - , and a minor fraction of Atacama-fertilizer-derived ClO4- was indicated in one of the wells. Data from this study expand the geographic area of the USA in which indigenous natural ClO 4 - has been detected to include the semi-arid northwest. This study also illustrates the role of irrigation recharge as a mechanism for producing relatively high concentrations of indigenous natural ClO 4 - in groundwater by flushing accumulated salts from the unsaturated zone.
The Associated Particle technique has recently been utilized with a germanium-based high-resolution $\gamma$-ray spectrometer and assessed for its capability to improve field identification of recovered chemical warfare (CW) materiel through prompt gamma-ray neutron activation analysis (PGNAA) measurements. An accurate chemical identification is necessary for the safe handling, destruction, and disposal of such hazardous items. A particularly challenging pair of CW agents commonly found in recovered munitions are phosgene (CG) and cyanogen chloride (CK), which have two of three elements in common, i.e. chlorine and carbon, but differ in the third being either oxygen or nitrogen. The detection of both latter elements is complicated by high oxygen concentration in the field environment which interferes with the small signal produced from the chemical agents. The matter is further complicated by the precautionary field practice of overpacking recovered munitions with vermiculite in larger steel multiple round containers (MRCs), which places additional oxygen-rich material around the munition while further attenuating an already weak signal emitted from the munition center. Here, this work reports quantitative results from realistic field measurements of CG and CK simulants in mock 4.2-inch mortar rounds overpacked with vermiculite in a large MRC. Results obtained with the AP technique are compared to those obtained with the traditional PGNAA approach for both overpacked- and bare-munition measurements. The AP technique is shown to provide a much more confident discrimination between the two chemicals, particularly for the more challenging field-relevant overpacked measurements, where a significant gain in sensitivity to all the key elements chlorine, carbon, nitrogen and oxygen is achieved.
The main objective of the present study was to integrate {sup 18}F-FDG-PET/CT radiomics with multiblock discriminant analysis for predicting circulating tumor cells (CTCs) in early-stage non-small cell lung cancer (ES-NSCLC) treated with stereotactic body radiation therapy (SBRT).
The scintillation process in plastic scintillators has been studied with mixed systems containing high concentrations of multiple fluorescence dyes. It has been shown that the triplet–triplet interaction phenomena leading to the production of delayed light and pulse shape discrimination (PSD) can vary depending on the triplet energies of the interacting dyes. At small differences between the first excited triplet state energies, found to be below 0.1 eV, a pair of interacting dyes of different molecular species can be involved in heterogeneous excitation migration and triplet–triplet annihilation that result in the enhancement of delayed light and PSD, due to the engagement of both dyes in the process. At differences above 0.27 eV, excitation trapping on the lower energy triplet molecules leads to conditions when triplet–triplet migration and annihilation can proceed only homogeneously between molecules of the same species. The results explain the different effects produced by the selection of fluorescent dyes in previously reported PSD systems containing one primary and one secondary dyes. They also demonstrate a non-traditional approach to the design of new plastic scintillators with multiple dyes that, at improved scintillation and PSD performance, may simplify the production process.