Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “direct electron detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

In situ TEM observation of electrochemical lithiation of sulfur confined within inner cylindrical pores of carbon nanotubes

Lithium insertion into sulfur confined within 200 nm cylindrical inner pores of individual carbon nanotubes (CNTs) was monitored in-situ in a transmission electron microscope (TEM). This electrochemical reaction was initiated at one end of the S-filled CNTs. The material expansion during lithiation was accommodated by the expansion into the remaining empty pore volume and no fracture of the CNT walls was detected. A sharp interface between the initial and lithiated S was observed. The reaction front was flat, oriented perpendicular to the confined S cylinder and propagated along the cylinder length. Lithiation of S in the proximity of conductive carbon proceeded at the same rate as the one in the center of the pore, suggesting the presence of electron pathways at the Li 2 S/S interface. Density of states (DOS) calculations further confirmed this hypothesis. In-situ electron diffraction showed a direct phase transformation of S into nanocrystalline Li 2 S without detectable formation of any intermediates, such as polysulfides and LiS. These important insights may elucidate some of the reaction mechanisms and guide the improvements in the design of C-S nanocomposites for high specific energy Li-S batteries. As a result, the proposed use of conductive CNTs with tunable pore diameter as cylindrical reaction vessels for in-situ TEM studies of electrochemical reactions proved to be highly advantageous and may help to resolve the on-going problems in battery technology.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Review of current neutron detection systems for emergency response

Neutron detectors are utilized in a myriad of applications—from safeguarding special nuclear materials (SNM) to determining lattice spacing in soft materials. The transformational changes taking place in neutron detection and imaging techniques in the last few years are largely being driven by the global shortage of helium-3 ( 3 He). This article reviews the status of neutron sensors used specifically for SNM detection in radiological emergency response. These neutron detectors must be highly efficient, be rugged, have fast electronics to measure neutron multiplicity, and be capable of measuring direction of the neutron sources and possibly image them with high spatial resolution. Neutron detection is an indirect physical process: neutrons react with nuclei in materials to initiate the release of one or more charged particles that produce electric signals that can be processed by the detection system. Therefore, neutron detection requires conversion materials as active elements of the detection system; these materials may include boron-10 ( 10 B), lithium-6 ( 6 Li), and gadollinium-157 ( 157 Gd), to name a few, but the number of materials available for neutron detection is limited. However, in recent years, pulse-shape-discriminating plastic scintillators, scintillators made of helium-4 ( 4 He) under high pressure, pillar and trench semiconductor diodes, and exotic semiconductor neutron detectors made from uranium oxide and other materials have widely expanded the parameter space in neutron detection methodology. In this article we will pay special attention to semiconductor-based neutron sensors. Finally, modern microfabricated nanotubes covered inside with neutron converter materials and with very high aspect ratios for better charge transport will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physical properties of (La,Sr)Ti(O,N){sub 3} thin films grown by pulsed laser deposition

Thin films of La{sub x}Sr{sub 1-x}TiO{sub 3+x/2} (x = 0, 0.25, 0.5, 0.75, 1) were grown by laser ablation on two different kinds of substrates (SrTiO{sub 3} (STO) and MgO) and were subsequently ammonolysed to yield the corresponding oxynitrides La{sub x}Sr{sub 1-x}Ti(O,N){sub 3}. For both substrates all films were found to grow epitaxially to the (1 0 0) direction of the cubic perovskite structure, except for x = 0.5 that grew parallel to the (1 1 0) direction. For some of the films TiN was detected as impurity phase. Scanning electron microscopy revealed that the films are dense and homogeneous with thicknesses around 350 nm. Atomic force microscopy showed that the surface roughness of the films varied between 4.2 and 14.1 nm. The employed substrate had a strong influence on the electrical properties. Films grown on STO exhibited a metallic behaviour, in contrast to the films grown on MgO, which were insulating.

36 MATERIALS SCIENCE↗

A closed-loop phase-locked interferometer for wide bandwidth position sensing

This article describes a position sensitive interferometer with closed-loop control of the reference mirror. A calibrated nanopositioner is used to lock the interferometer phase to the most sensitive point in the interferogram. In this configuration, large low-frequency movements of the sensor mirror can be detected from the control signal applied to the nanopositioner and high-frequency short-range signals can be measured directly from the photodiode. It is demonstrated that these two signals are complementary and can be summed to find the total displacement. The resulting interferometer has a number of desirable characteristics: it is optically simple, does not require polarization or modulation to detect the direction of motion, does not require fringe-counting or interpolation electronics, and has a bandwidth equal to that of the photodiode. Experimental results demonstrate the frequency response analysis of a high-speed positioning stage. The proposed instrument is ideal for measuring the frequency response of nanopositioners, electro-optical components, MEMs devices, ultrasonic devices, and sensors such as surface acoustic wave detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dark Matter Candidates of a Very Low Mass

We review dark matter (DM) candidates of a very low mass appearing in the window below the traditional weakly interacting massive particle (m χ ≲ 10 GeV) and extending down to m χ ≳ 1 meV, somewhat below the mass limit at which DM becomes wavelike. Such candidates are motivated by hidden sectors such as hidden valleys, which feature hidden forces and rich dynamics, but have evaded traditional accelerator searches for New Physics because of their relatively weak coupling to the Standard Model (SM). Such sectors can still be detected through dedicated low-energy colliders, which, through their intense beams, can have sensitivity to smaller couplings, or through astrophysical observations of the evolution of DM halos and stellar structures, which, through the Universe's epochs, can be sensitive to small DM interactions. We also consider mechanisms whereby the DM abundance is fixed through the interaction with the SM, which directly motivates the search for light DM in terrestrial experiments. The bulk of this review is dedicated to the new ideas that have been proposed for direct detection of such DM candidates of a low mass through nuclear recoils, electronic excitations, or collective modes such as phonons and magnons. The rich tapestry of materials and modes in the condensed matter landscape is reviewed along with specific prospects for detection.

Physics↗

Origin of diffuse gamma-ray background

It is shown that the observed spectrum of the diffuse gamma-ray background could be accounted for by unresolved active galaxies even with no evolution, if their spectra are described by a spherical accretion/shock acceleration model (1983) and are steepened by photon-photon pair production interactions at high energies. The model is based on HEAO-1 and SAS-2 observations in the region of 2 to 165 keV and above 30 MeV. The model predicts a higher flux of high-energy neutrinos from active galaxies than models in which electrons are accelerated directly. It is noted that several active galaxies should be detectable by the Gamma-Ray Observatory, making it possible to determine the actual contribution of active galaxies to the diffuse gamma-ray background.

Protheroe, R. J.↗

Electron density distribution in the magnetosphere

Eight months of differential potential measurements from the POLAR satellite were used to study the electron density distribution in the magnetosphere and its dependence on the level of geomagnetic activity identified by the Kp index. The differential potential measurement is directly proportional to the electron density, and this technique can be used for detecting fast electron density variation in low-density plasmas with a good accuracy. The inner magnetospheric regions are particularly investigated in this study. The cusp is found to be denser during low Km, and it moves equator-ward with increasing Km. The plasmapause is quite asymmetric, as expected. In particular, on the nightside, the plasmapause is compressed closer to the earth with increasing Kp. While the density gradients at the dayside plasmapause are usually not very steep, they can be quite large at other time sectors. A particularly pronounced sharpening of the plasmapause occurs at the dusk sector with increasing Kp. The density in the region between the dayside plasmapause and magnetopause is relatively high during all Kp levels; the average densities are several electrons per cubic meter. During disturbed periods, the density in the near-earth plasma sheet near midnight increases and becomes higher than the densities towards the flanks of the plasma sheet.

Laakso, H.↗

An Ultrasensitive Hot-Electron Bolometer for Low-Background SMM Applications

We are developing a hot-electron superconducting transition-edge sensor (TES) that is capable of counting THz photons and operates at T = 0.3K. The main driver for this work is moderate resolution spectroscopy (R approx. 1000) on the future space telescopes with cryogenically cooled (approx. 4 K) mirrors. The detectors for these telescopes must be background-limited with a noise equivalent power (NEP) approx. 10(exp -19)-10(exp -20) W/Hz(sup 1/2) over the range v = 0.3-10 THz. Above about 1 THz, the background photon arrival rate is expected to be approx. 10-100/s), and photon counting detectors may be preferable to an integrating type. We fabricated superconducting Ti nanosensors with a volume of approx. 3x10(exp -3) cubic microns on planar substrate and have measured the thermal conductance G to the thermal bath. A very low G = 4x10(exp -14) W/K, measured at 0.3 K, is due to the weak electron-phonon coupling in the material and the thermal isolation provided by superconducting Nb contacts. This low G corresponds to NEP(0.3K) = 3x10(exp -19) W/Hz(sup 1/2). This Hot-Electron Direct Detector (HEDD) is expected to have a sufficient energy resolution for detecting individual photons with v > 0.3 THz at 0.3 K. With the sensor time constant of a few microseconds, the dynamic range is approx. 50 dB.

bolometers↗

Low Q2 Kaon Electroproduction at W=2.2 GeV off Hydrogen

A measurement of the H(e,e'K) reaction was performed at Hall A, TJNAF as part of the hypernuclear experiment E94-107. One important ingredient to the hypernuclear cross section calculation is the elementary cross section for production of hyperons, $\Lambda $ and $\Sigma ^{0}$. This was measured using a hydrogen (i.e. a proton) target. Data was taken at very low Q$^{2}$ ($\sim $0.07 GeV$^{2})$ and W$\sim $2.2 GeV. Kaons were detected along the direction of \textbf{q}, the momentum transferred by the incident electron ($\Theta _{CM}\sim $6$^{o})$. In addition, there is not much data available for electroproduction of hyperons at low Q$^{2}$ and $\Theta _{CM}$ and the available theoretical models differ a lot in this kinematical region of W. The measurement of the elementary cross section will help not only in the hypernuclear spectroscopy studies but also in constraining existing theoretical models for the elementary reaction. Measurements of the differential cross sections and the $\Sigma ^{0}$/$\Lambda $ production ratio will be reported as well as their results binned in Q$^{2}$ ,W and $\Theta _{CM}$ to understand the dependence on these variables. Details of the calculations and results will be shown.

Acha, Armando↗

On The Origin of Light Dark Matter Species

TeV-mass dark matter charged under a new GeV-scale gauge force can explain electronic cosmic-ray anomalies. We propose that the CoGeNT and DAMA direct detection experiments are observing scattering of light stable states 'GeV-Matter' that are charged under this force and constitute a small fraction of the dark matter halo. Dark higgsinos in a supersymmetric dark sector are natural candidates for GeV-Matter that scatter off protons with a universal cross-section of 5 x 10{sup -38} cm{sup 2} and can naturally be split by 10-30 keV so that their dominant interaction with protons is down-scattering. As an example, down-scattering of an O(5) GeV dark higgsino can simultaneously explain the spectra observed by both CoGeNT and DAMA. The event rates in these experiments correspond to a GeV-Matter abundance of 0.2-1% of the halo mass density. This abundance can arise directly from thermal freeze-out at weak coupling, or from the late decay of an unstable TeV-scale WIMP. Our proposal can be tested by searches for exotics in the BaBar and Belle datasets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A high contrast method of unstained biological samples under a thin carbon film by scanning electron microscopy

The contrast of biological samples in scanning electron microscopy (SEM) is very weak. To examine a biological specimen by SEM, many steps and/or special equipment are required to prepare the sample. Here, we describe a method using an unstained biological sample under a 40 nm carbon film to give a high contrast image, where the image is detected by the secondary electron (SE) signal at a low accelerating voltage of 1.5 kV. Under these conditions, it is hard to detect a direct signal from a biological specimen. The high contrast image is created by the SEs from the lower surface of the thin carbon film. Therefore, the damage to the sample from the electron beam is very low. Our method can be utilized to observe various biological samples of bacteria, viruses, and protein complexes.

60 APPLIED LIFE SCIENCES↗

Ultrawide bandgap semiconductor h-BN for direct detection of fast neutrons

III-nitride wide bandgap semiconductors have contributed on the grandest scale to many technological advances in lighting, displays, and power electronics. Among III-nitrides, BN has another unique application as a solid-state neutron detector material because the isotope B-10 is among a few elements that have an unusually large interaction cross section with thermal neutrons. A record high thermal neutron detection efficiency of 60% has been achieved by B-10 enriched h-BN detectors of 100 μm in thickness in our group. However, direct detection of fast neutrons with energies above 1 MeV is highly challenging due to the extremely low interaction cross section of fast neutrons with matter. We report the successful attainment of 0.4 mm thick freestanding h-BN 4"-diameter wafers, which enabled the demonstration of h-BN fast neutron detectors capable of delivering a detection efficiency of 2.2% in response to a bare AmBe neutron source. Furthermore, it was shown that the energy information of incoming fast neutrons is retained in the neutron pulse-height spectra. A comparison of characteristics between h-BN fast and thermal neutron detectors is summarized. Neutron detectors are vital diagnostic instruments for nuclear and fusion reactor power and safety monitoring, oil field exploration, neutron imaging and therapy, as well as for plasma and material science research. With the outstanding attributes resulting from its ultrawide bandgap (UWBG), including the ability to operate at extreme conditions of high power, voltage, and temperature, the availability of h-BN UWBG semiconductor detectors with the capability of simultaneously detecting thermal and fast neutrons with high efficiencies is expected to open unprecedented applications that are not possible to attain by any other types of neutron detectors.

36 MATERIALS SCIENCE↗

(In)direct detection of boosted dark matter

We initiate the study of novel thermal dark matter (DM) scenarios where present-day annihilation of DM in the galactic center produces boosted stable particles in the dark sector. These stable particles are typically a subdominant DM component, but because they are produced with a large Lorentz boost in this process, they can be detected in large volume terrestrial experiments via neutral-current-like interactions with electrons or nuclei. This novel DM signal thus combines the production mechanism associated with indirect detection experiments (i.e. galactic DM annihilation) with the detection mechanism associated with direct detection experiments (i.e. DM scattering off terrestrial targets). Such processes are generically present in multi-component DM scenarios or those with non-minimal DM stabilization symmetries. As a proof of concept, we present a model of two-component thermal relic DM, where the dominant heavy DM species has no tree-level interactions with the standard model and thus largely evades direct and indirect DM bounds. Instead, its thermal relic abundance is set by annihilation into a subdominant lighter DM species, and the latter can be detected in the boosted channel via the same annihilation process occurring today. Especially for dark sector masses in the 10 MeV–10 GeV range, the most promising signals are electron scattering events pointing toward the galactic center. These can be detected in experiments designed for neutrino physics or proton decay, in particular Super-K and its upgrade Hyper-K, as well as the PINGU/MICA extensions of IceCube. This boosted DM phenomenon highlights the distinctive signatures possible from non-minimal dark sectors.

79 ASTRONOMY AND ASTROPHYSICS↗

Cosmology and signals of light pseudo-Dirac dark matter

In this paper, we analyze the cosmological evolution, allowed parameter space, and observational prospects for a dark sector consisting of thermally produced pseudo-Dirac fermions with a small mass splitting, coupled to the Standard Model through a dark photon. This scenario is particularly notable in the context of sub-GeV dark matter, where the mass-off-diagonal leading interaction limits applicability of both CMB energy injection constraints and standard direct detection searches. We present the first general study of the thermal history of pseudo-Dirac DM with splittings from 100 eV to MeV, focusing on the depletion of the heavier “excited” state abundance via scatterings and decays, and on the distinctive signals arising from its small surviving abundance. We analyze CMB energy injection bounds on both DM annihilation and decay, accelerator-based probes, and new line-like direct-detection signals from the excited DM down-scattering on either nuclei or electrons, as well as future search prospects in each channel. We also comment on the relevance of this signal to the few-keV Xenon1T electron excess and on possible diurnal modulation of this signal, and introduce a signal-strength parametrization to facilitate the comparison of future experimental results to theoretical expectations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New beam-charge interlock system for radiation safety at the KEKB injector linac

A new beam-charge interlock system is under development for radiation safety and machine protection at the KEKB injector linac. A hardware-based interlock system is required instead of the present software-based interlock system in order to boost its reliability. This system restricts the integrated amount of beam charges delivered to four different storage rings. The beam charges are measured using wall-current monitors and detection electronics at six locations along the linac. The detection electronics independently transmits a beam-abort request through a twisted hardwire cable directly to the safety control system of the linac, when the integrated amount of beam charges exceeds a certain threshold level prescribed for each location. We describe the characteristics and performance of the new beam-charge interlock system along with the details of the experimental tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Skipper-CCD sensors for the Oscura experiment: requirements and preliminary tests

Oscura is a proposed multi-kg skipper-CCD experiment designed for a dark matter (DM) direct detection search that will reach unprecedented sensitivity to sub-GeV DM-electron interactions with its 10 kg detector array. Oscura is planning to operate at SNOLAB with 2070 m overburden, and aims to reach a background goal of less than one event in each electron bin in the 2–10 electron ionization-signal region for the full 30 kg-year exposure, with a radiation background rate of 0.01 dru.[1 dru (differential rate unit) corresponds to 1 event/kg/day/keV.] In order to achieve this goal, Oscura must address each potential source of background events, including instrumental backgrounds. In this work, we discuss the main instrumental background sources and the strategy to control them, establishing a set of constraints on the sensors' performance parameters. We present results from the tests of the first fabricated Oscura prototype sensors, evaluate their performance in the context of the established constraints and estimate the Oscura instrumental background based on these results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mixed domain coherent link with electrically reconfigurable IMDD and coherent modes for O-band data center applications

We report the first O-band link with electrically reconfigurable intensity-modulation direct-detection (IMDD) and coherent operation using custom silicon photonic chips packaged with commercial electronic chips. Transmission below the KP4-FEC threshold is shown using commercial 53 Gbaud PAM4 digital signal processing (DSP) for 16QAM (200 Gbps/ λ ) and PAM4 (100 Gbps/ λ ). Efficient operation of the packaged full link at 12 and 11.2 pJ/bit is achieved for the PAM4 and 16QAM modes, respectively.

Misak, Stephen (ORCID:0000000154973084)↗