Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “direct current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Floating Photovoltaics in Hydropower Reservoirs in the United States

This report presents a comprehensive analysis of the feasibility of floating photovoltaics (FPV) in federally regulated reservoirs within the continental United States (CONUS) and to present a methodology for capturing the true costs of deployment, potential environmental impacts, and regulatory pathways for open-loop hydropower reservoirs. It is intended for stakeholders who may not be solar industry experts but who are interested in exploring the potential for FPV in their reservoirs. While there are promising opportunities, particularly in enhancing dissolved oxygen (DO) levels and potentially improving compliance with existing hydropower licenses, the current capital costs of FPV are not yet competitive with traditional land-based solar installations at the utility-scale when comparing the LCOE results. A competitive financial outlook is achievable when applying a 30% Investment Tax Credit (ITC) and considering a 5% reduction from the baseline capital expenditures (CapEx) at the Tuckertown Reservoir in North Carolina case study. The study is structured around three key pillars of research: technical potential, environmental impacts and regulatory considerations, and technoeconomic analysis. This report provides a nationwide assessment of the opportunities for FPV in terms of capacity, measured in direct current megawatts (MWDC), in reservoirs managed by the U.S. Bureau of Reclamation (USBR), the U.S. Army Corps of Engineers (USACE), and the Federal Energy Regulatory Commission (FERC). Additionally, the report introduces a heuristic model for estimating the CapEx of utility-scale FPV projects (1–100 MW), offering a baseline cost estimate for stakeholders. Finally, the report applies these models to a case study of a hydropower reservoir in North Carolina to present site-specific results.

13 - HYDRO ENERGY↗

Current-driven transverse domain wall oscillations in perpendicular spin-valve structures

Spin-transfer-driven oscillations of a transverse domain wall confined to a perpendicular spin-valve structure are investigated using a one-dimensional model. The stack consists of a polarizer, nonmagnetic spacer, soft free layer, and pinned magnetic layer. It is found that the domain-wall oscillation frequency is a nonmonotonic, highly asymmetrical function of applied electric current, showing a strong dependence on the current direction and the relative strengths of the interfacial and bulk spin-transfer torques. Micromagnetic analysis reveals that the surprising and atypical oscillator response is due to an interplay between the interfacial spin-transfer torque, the bulk spin-transfer torque, the exchange torque, and the damping torque. The underlying physical and material responses are examined, including the important role of the domain-wall twist. The competitions between the involved torques under different operating conditions suggest that the oscillator could serve as a model system to investigate magnetic and spintronic phenomena at the nanoscale. Finally, the observed current-dependent twisting of the free-layer magnetization about the axis of precession may further be found interesting for investigations of the interaction between spin-polarized current and chiral spin structures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hybrid Symbolic-Numerical Modeling and Parametric Stability Analysis of DC–AC Power Systems

Hybrid DC-AC power systems integrating diverse inverter-based resources (IBRs) and multi-terminal high-voltage direct current (MTDC) networks represent a promising architecture for future power grids, while introducing challenges for modeling, stability analysis, and control design. This paper develops a hybrid symbolic-numerical modeling framework and tool to characterize the parametric small-signal stability of DC-AC coupled power systems. The proposed approach constructs parametric state-space models to enable efficient representation of system dynamics under varying control parameters and network configurations, with target parameters retained as symbolic variables and the remainder treated numerically. The stability analysis framework covers eigenvalue, sensitivity, and stability boundary and region characterization. Enhanced linear matrix inequality (LMI) techniques are proposed to directly certify small-signal stability over regions of parameter space while also reducing the conservativeness and computational burden. The resulting tools and frameworks enable rapid parametric model construction across diverse grid conditions, thereby facilitating stability-informed control and operation in complex DC–AC power systems.

DC–AC power systems↗

Dual Impacts of Space Heating Electrification and Climate Change Increase Uncertainties in Peak Load Behavior and Grid Capacity Requirements in Texas

Around 60% of households in Texas currently rely on electricity for space heating. As decarbonization efforts increase, non‐electrified households could adopt electric heat pumps, significantly increasing peak (highest) electricity demand in winter. Simultaneously, anthropogenic climate change is expected to increase temperatures, the potential for summer heat waves, and associated electricity demand for cooling. Uncertainty regarding the timing and magnitude of these concurrent changes raises questions about how they will jointly affect the seasonality of peak demand, firm capacity requirements, and grid reliability. This study investigates the net effects of residential space heating electrification and climate change on long‐term demand patterns and load shedding potential, using climate change projections, a predictive load model, and a direct current optimal power flow (DCOPF) model of the Texas grid. Results show that full electrification of residential space heating by replacing existing fossil fuel use with higher efficiency heat pumps could significantly improve reliability under hotter futures. Less efficient heat pumps may result in more severe winter peaking events and increased reliability risks. As heating electrification intensifies, system planners will need to balance the potential for greater resource adequacy risk caused by shifts in seasonal peaking behavior alongside the benefits (improved efficiency and reductions in emissions).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Validation of a Modular All-Electric Power Take-Off Topology for Wave Energy Converter Enabling Marine Renewable Energy Interconnection

Power electronic converters are an enabling technology for the emerging marine energy applications, such as using ocean waves to produce electricity. This paper outlines the power take-off system and its key components used in a wave energy converter offering modularity and scalability to generate power efficiently. The proposed power take-off system was implemented based on a modular multilevel converter and could be deployed to convert any alternating current electrical energy to a different alternating current for interconnection to grid or non-grid applications. Examples of widespread deployment are supplying electricity to coastal communities or producing clean drinking water. The analysis using both the simulation tests and laboratory experiments verified the design objectives and basic functionality of the developed power take-off system. An acceptable response using a field programmable gate array-based controlled laboratory testbench was achieved, complying with guidelines specified in the prevalent industry standards. Seamless operation during steady-state and transients for the studied wave energy converter was achieved as supported by the obtained results. The key findings of this work were experimentally examined under different load conditions, direct current bus voltage fluctuations, and generator speed–torque regulation. The ability of the power take-off system to generate high-power quality of the waveforms, e.g., against adhering to the IEEE 519-2022 standard for total harmonic distortion limits, is also confirmed.

Engineering↗

Oxygen vacancy migration and impact on high voltage DC polarization in 0.8BaTiO 3 –0.2BiZn 0.5 Ti 0.5 O 3

Electrical polarization and defect transport are examined in 0.8BaTiO 3 –0.2BiZn 0.5 Ti 0.5 O 3 , an attractive capacitor material for high power electronics. Oxygen vacancies are suggested to be the majority charge carrier at or below 250°C with a grain conduction hopping activation energy of 0.97 eV and 0.92 eV for thermally stimulated depolarization current (TSDC) and impedance spectroscopy measurements, respectively. At higher temperature, thermally generated electronic conduction with an activation energy of 1.6 eV is dominant. Significant oxygen vacancy concentration is indicated (up to ~1%) due to cation vacancy formation (i.e., acceptor defects) from observed Bi (and likely Zn) volatility. Oxygen vacancy diffusivity is estimated to be 10 -12.8 cm 2 /s at 250°C. Low diffusivity and high activation energies are indicative of significant defect interactions. Dipolar oxygen vacancy defects are also indicated, with an activation energy of 0.59 eV from TSDC measurements. In conclusion, the large oxygen vacancy content leads to a short lifetime during high voltage (30 kV/cm), high temperature (250°C) direct current (DC) electrical measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Suppression of toroidal Alfvén eigenmodes by the electron cyclotron current drive in KSTAR plasmas

Advanced operation scenarios such as high poloidal beta ( β P ) or high q min are promising concepts to achieve the steady-state high-performance fusion plasmas. However, those scenarios are prone to substantial Alfvénic activity, causing fast-ion transport and losses. Recent experiments with the advanced operation scenario on KSTAR tokamak have shown that the electron cyclotron current drive (ECCD) is able to mitigate and suppress the beam-ion driven toroidal Alfvén eigenmodes (TAEs) for over several tens of global energy confinement time. Co-current directional intermediate off-axis ECCD lowers the central safety factor slightly and tilts the central q -profile shape so that the continuum damping in the core region increases. Besides, the rise of central plasma pressure and increased thermal-ion Landau damping contribute to TAE stabilization. While the TAEs are suppressed, neutron emission rate and total stored energy increase by approximately 45% and 25%, respectively. Fast-ion transport estimated by TRANSP calculations approaches the classical level during the TAE suppression period. Substantial reduction in fast-ion loss and neutron deficit is also observed. Subsequently, enhancement of fast-ion confinement by suppressing the TAEs leads to an increase of non-inductive current fraction and will benefit the sustainment of the long-pulse high-performance discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrically Accelerated Mechanochemical Film Formation by a Phosphonium Phosphate Ionic Liquid: An In Situ Chemical Kinetics Investigation

Powertrains in electric vehicles are exposed to stray currents that accelerate wear and cause failure of mechanical components. These durability issues are further aggravated when using low-viscosity lubricants, which are desired for energy efficiency but create harsher contact conditions at sliding interfaces. This study investigates a phosphonium phosphate ionic liquid as a performance-enhancing additive in a low-viscosity base oil for lubricating electrified sliding interfaces. Ionic liquids can adsorb and react on contact interfaces via stress-assisted chemical reactions, generating nanometric tribofilms that provide protection against wear. However, the effect of electric fields on the mechanochemistry of ionic liquids is poorly understood, hindering their adoption in lubricants for electrified powertrains. This article reports an in situ optical interferometry study of ionic liquid derived tribofilm growth kinetics at stressed sliding/rolling interfaces under direct currents. The application of electric currents accelerated tribofilm formation up to a critical current density (∼1.4 A/mm 2 ), beyond which pitting-induced wear dominated. The tribofilms were composed of iron phosphates, iron oxides, and carbon species, with iron oxides becoming predominant under applied currents. These tribofilms prevented the scuffing failure of steel surfaces under electrified conditions. Based on the results, a kinetic model is proposed that integrates electric current effect into the classical stress-assisted thermal activation framework to allow prediction of tribofilm growth at electrified sliding contacts. This framework provides crucial guidance for designing next-generation lubricants for electrified transportation and power generation systems.

additives↗

A Framework to Analyze the Requirements of a Multiport Megawatt-Level Charging Station for Heavy-Duty Electric Vehicles

Widespread adoption of heavy-duty (HD) electric vehicles (EVs) will soon necessitate the use of megawatt (MW)-scale charging stations to charge high-capacity HD EV battery packs. Such a station design needs to anticipate possible station traffic, average and peak power demand, and charging/wait time targets to improve throughput and maximize revenue-generating operations. High-power direct current charging is an attractive candidate for MW-scale charging stations at the time of this study, but there are no precedents for such a station design for HD vehicles. We present a modeling and data analysis framework to elucidate the dependencies of a MW-scale station operation on vehicle traffic data and station design parameters and how that impacts vehicle electrification. This framework integrates an agent-based charging station model with vehicle schedules obtained through real-world vehicle telemetry data analysis to explore the station design and operation space. A case study applies this framework to a Class 8 vehicle telemetry dataset and uses Monte Carlo simulations to explore various design considerations for MW-scale charging stations and EV battery technologies. The results show a direct correlation between optimal charging station placement and major traffic corridors such as cities with ports, e.g., Los Angeles and Oakland. Corresponding parametric sweeps reveal that while good quality of service can be achieved with a mix of 1.2-megawatt and 100-kilowatt chargers, the resultant fast charging time of 35–40 min will need higher charging power to reach parity with refueling times.

33 ADVANCED PROPULSION SYSTEMS↗

Theoretical Analysis of Experimental Data of Sodium Diffusion in Oxidized Molybdenum Thin Films

In this work, the diffusion process of sodium (Na) in molybdenum (Mo) thin films while it was deposited on soda lime glass (SLG) was studied. A small amount of oxygen was present in the chamber while the direct-current (DC) magnetron sputtering was used for the deposition. The substrate temperatures were varied to observe its effect. Such molybdenum films, with or without oxidations, are often used in thin film solar cells, either as back contact or as hole transport layers. Secondary ion mass spectrometry (SIMS) was used to quantify the concentration of the species. A grain diffusion mechanistic model incorporating the effect of grain and grain boundary geometrical shape and size was developed. The model was used to provide an in-depth theoretical analysis of the sodium diffusion in molybdenum thin films that lead to the measured SIMS data. It was observed that not only diffusion coefficients should be considered when analyzing diffusion processes in thin films but also the ratio of grain boundary size to grain size. Both depend on substrate temperature and directly affect the amount of diffused species in the film. The data were analyzed under the light of the film growth speed versus diffusion front speed, the effect of oxygen content, and the effect of substrate temperature on the overall diffusion process. The temperature inversely affects the ratio of grain boundary size and grain size and directly affects the diffusion coefficient, which leads to a preferable temperature at which the highest amount of alkali can be found in the film.

36 MATERIALS SCIENCE↗

Power Grid Reliability Estimation via Adaptive Importance Sampling

Electricity production currently generates approximately 25% of greenhouse gas emissions in the USA. Thus, increasing the amount of renewable energy is a key step to carbon neutrality. However, integrating a large amount of fluctuating renewable generation is a significant challenge for power grid operating and planning. Grid reliability, i.e., an ability to meet operational constraints under power fluctuations, is probably the most important of them. In this letter, we propose computationally efficient and accurate methods to estimate the probability of line overflow, i.e., reliability constraints violation, under a known distribution of renewable energy generation. To this end, we investigate an importance sampling approach, a flexible extension of Monte-Carlo methods, which adaptively changes the sampling distribution to generate more samples near the reliability boundary. The approach allows to estimate overload probability in real-time based only on a few dozens of random samples, compared to thousands required by the plain Monte-Carlo. Our study focuses on high voltage direct current power transmission grids with linear reliability constraints on power injections and line currents. Herein, we propose a novel theoretically justified physics-informed adaptive importance sampling algorithm and compare its performance to state-of-the-art methods on multiple IEEE power grid test cases.

power system faults↗

Power Flow Geometry and Approximation

Here, the power flow equations are important in numerous power systems problems of practical interest which consider alternating current power flow (ACPF) physics. Perhaps the most well studied being the alternating current optimal power flow problem (ACOPF), seeking to optimize the operation of an electric power system. Due to their non-linearity, problems which include the power flow equations are typically challenging, particularly in optimization. Interestingly, the set of solutions to the power flow equations forms a smooth manifold. As a result, differential geometry can be used to describe and analyze this set of equations. This approach has proven effective in several engineering applications (e.g., solving ACOPF and analyzing the solution space boundary). Central to the success of this approach is an understanding of the power flow manifold's geometry. In this work, we develop the geometric and topological properties of this manifold using concepts from differential geometry. After demonstrating the convenience of this manifold's representation as a function's graph, computational methods are emphasized: we develop retractions, error bounds for linear approximation, and formulas for evaluating the Riemannian metric (including associated objects such as geodesics and the curvature tensor). Scalar curvature and the second fundamental form play a new role in quantifying the quality of linear approximations, like the popular direct current approximation. All functions are implemented in Julia and available in an online repository. Proofs are included for completeness.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

Unexpected Giant Microwave Conductivity in a Nominally Silent BiFeO 3 Domain Wall

Nanoelectronic devices based on ferroelectric domain walls (DWs), such as memories, transistors, and rectifiers, have been shown in recent years. Practical high-speed electronics, on the other hand, usually demand operation frequencies in the gigahertz (GHz) regime, where the effect of dipolar oscillation is important. Herein, an unexpected giant GHz conductivity on the order of 10 3 S m -1 is observed in certain BiFeO 3 DWs, which is about 100 000 times greater than the carrier-induced direct current (dc) conductivity of the same walls. Surprisingly, the nominal configuration of the DWs precludes the alternating current (ac) conduction under an excitation electric field perpendicular to the surface. Theoretical analysis reflects that the inclined DWs are stressed asymmetrically near the film surface, whereas the vertical walls in a control sample are not. The resultant imbalanced polarization profile can then couple to the out-of-plane microwave fields and induce power dissipation, which is confirmed by the phase-field modeling. Since the contributions from mobile-carrier conduction and bound-charge oscillation to the ac conductivity are equivalent in a microwave circuit, the research on local structural dynamics may open a new avenue to implement DW nano-devices for radio-frequency applications.

36 MATERIALS SCIENCE↗

A Four‐Coordinate Pr 4+ Imidophosphorane Complex

Abstract The imidophosphorane ligand, [NP t Bu 3 ] − ( t Bu= tert ‐butyl), enables isolation of a pseudo‐tetrahedral, tetravalent praseodymium complex, [Pr 4+ (NP t Bu 3 ) 4 ] ( 1‐Pr ), which is characterized by a suite of physical characterization methods including single‐crystal X‐ray diffraction, electron paramagnetic resonance, and L 3 ‐edge X‐ray near‐edge spectroscopies. Variable‐temperature direct‐current magnetic susceptibility data, supported by multiconfigurational quantum chemical calculations, demonstrate that the electronic structure diverges from the isoelectronic Ce 3+ analogue, driven by increased crystal field. The four‐coordinate environment around Pr 4+ in 1‐Pr , which is unparalleled in reported extended solid systems, provides a unique opportunity to study the interplay between crystal field splitting and spin‐orbit coupling in a molecular tetravalent lanthanide within a pseudo‐tetrahedral coordination geometry.

Boggiano, Andrew C.↗

A Four‐Coordinate Pr 4+ Imidophosphorane Complex

Abstract The imidophosphorane ligand, [NP t Bu 3 ] − ( t Bu= tert ‐butyl), enables isolation of a pseudo‐tetrahedral, tetravalent praseodymium complex, [Pr 4+ (NP t Bu 3 ) 4 ] ( 1‐Pr ), which is characterized by a suite of physical characterization methods including single‐crystal X‐ray diffraction, electron paramagnetic resonance, and L 3 ‐edge X‐ray near‐edge spectroscopies. Variable‐temperature direct‐current magnetic susceptibility data, supported by multiconfigurational quantum chemical calculations, demonstrate that the electronic structure diverges from the isoelectronic Ce 3+ analogue, driven by increased crystal field. The four‐coordinate environment around Pr 4+ in 1‐Pr , which is unparalleled in reported extended solid systems, provides a unique opportunity to study the interplay between crystal field splitting and spin‐orbit coupling in a molecular tetravalent lanthanide within a pseudo‐tetrahedral coordination geometry.

Boggiano, Andrew C.↗

Quantifying optical loss of high-voltage degradation modes in photovoltaic modules using spectral analysis

The direct current bias for photovoltaic (PV) modules interconnected in series-strings may include both high voltage negative (“HV-”) and positive (“HV+”) polarity with respect to the electrical ground. Multiple degradation modes, resulting in quantifiable optical loss, were found to occur during HV-/HV+ sequential stress, including corrosion of the external glass surface, encapsulant delamination (at its interfaces with the glass and the PV cell), internal haze formation (resulting from a chemical interaction between the glass and the encapsulant), corrosion and migration of the gridlines, and corrosion of the silicon nitride (Si x N y ) antireflective coating on the cell. The effects of these separate modes were examined using monolithic (e.g., glass or PV cell) and laminated-coupon (glass/encapsulant/glass or glass/encapsulant/cell/encapsulant/backsheet) specimens. Characterizations during and after unbiased accelerated testing at 85°C/85% relative humidity included spectrophotometry, optical microscopy, electron microscopy, and ellipsometry. For some module components (i.e., the glass and the Si x N y coating), the optical performance was determined through iterative analysis of empirical measurements. Concentrating on just their spectral effect, a novel model was then developed to estimate the transfer of light to the PV cell and the return of light from the PV module with simultaneous degradation mechanisms, which was compared with a mini-module previously subjected to HV-/HV+ stress. Here the model suggests that one third of the current loss observed for the mini-module can be attributed to the optical degradation of the packaging materials. The dominant degradation modes include encapsulant delamination and corrosion of the Si x N y coating. Recommendations are given so that the optical model may be improved relative to accelerated testing and validated relative to field aging.

14 SOLAR ENERGY↗

Nitrogen fixation as NO x using air plasma coupled with heterogeneous catalysis at atmospheric pressure

Here, this study presents insights into the use of activated Al 2 O 3 catalysts to improve the energy efficiency of NO x production in atmospheric pressure air plasma. The introduction of catalysts in the direct current glow discharge system reduces the energy cost of NO x production by up to 45% at low gas flow rates. Notably, even when positioned away from the plasma zone, the catalyst enhanced NO x production, suggesting a significant role for the catalytic activation of downstream neutral species. The study also introduced a novel approach involving an air plasma jet infused with floating catalyst powder. This method significantly increased energy efficiency at higher discharge currents, with an associated energy cost of 2.9 MJ/mol for NO x production.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗