Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “digital light processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Machine Learning-Enabled Quantitative Analysis of Optically Obscure Scratches on Nickel-Plated Additively Manufactured (AM) Samples

Additively manufactured metal components often have rough and uneven surfaces, necessitating post-processing and surface polishing. Hardness is a critical characteristic that affects overall component properties, including wear. This study employed K-means unsupervised machine learning to explore the relationship between the relative surface hardness and scratch width of electroless nickel plating on additively manufactured composite components. The Taguchi design of experiment (TDOE) L9 orthogonal array facilitated experimentation with various factors and levels. Initially, a digital light microscope was used for 3D surface mapping and scratch width quantification. However, the microscope struggled with the reflections from the shiny Ni-plating and scatter from small scratches. To overcome this, a scanning electron microscope (SEM) generated grayscale images and 3D height maps of the scratched Ni-plating, thus enabling the precise characterization of scratch widths. Optical identification of the scratch regions and quantification were accomplished using Python code with a K-means machine-learning clustering algorithm. The TDOE yielded distinct Ni-plating hardness levels for the nine samples, while an increased scratch force showed a non-linear impact on scratch widths. The enhanced surface quality resulting from Ni coatings will have significant implications in various industrial applications, and it will play a pivotal role in future metal and alloy surface engineering.

36 MATERIALS SCIENCE↗

Future Vision for Instrumentation, Information and Control Modernization

A Future Vision of a transformed nuclear plant operating model based on an integrated digital environment has been developed as part of the Advanced Instrumentation, Information, and Control (II&C) research pathway, under the Light Water Reactor (LWR) Sustainability Program. This is a research and development program sponsored by the U.S. Department of Energy (DOE), performed in close collaboration with the nuclear utility industry, to provide the technical foundations for licensing and managing the long-term, safe and economical operation of current nuclear power plants. II&C has been identified as a potential life-limiting issue for the domestic LWR fleet in addressing the reliability and aging concerns of the legacy systems in service today. The Future Vision is based on a digital architecture that encompasses all aspects of plant operations and support, integrating plant systems, plant work processes, and plant workers in a seamless digital environment to enhance nuclear safety, increase productivity, and improve overall plant performance. Pilot projects are being conducted as the means for industry to gain confidence in these new technologies for use in nuclear plant work activities. The pilot projects introduce new digital technologies into the nuclear plant operating environment at host operating plants to demonstrate and validate them for production usage. In turn, the pilot project technologies serve as the stepping stones to the eventual seamless digital environment as described in the Future Vision. Initial project results confirm that the technologies can address provide substantial efficiency and human performance benefits while resolving the reliability and aging concerns.

99 GENERAL AND MISCELLANEOUS↗

The use of computed radiography plates to determine light and radiation field coincidence

Purpose: Photo-stimulable phosphor computed radiography (CR) has characteristics that allow the output to be manipulated by both radiation and optical light. The authors have developed a method that uses these characteristics to carry out radiation field and light field coincidence quality assurance on linear accelerators.Methods: CR detectors from Kodak were used outside their cassettes to measure both radiation and light field edges from a Varian linear accelerator. The CR detector was first exposed to a radiation field and then to a slightly smaller light field. The light impinged on the detector's latent image, removing to an extent the portion exposed to the light field. The detector was then digitally scanned. A MATLAB-based algorithm was developed to automatically analyze the images and determine the edges of the light and radiation fields, the vector between the field centers, and the crosshair center. Radiographic film was also used as a control to confirm the radiation field size.Results: Analysis showed a high degree of repeatability with the proposed method. Results between the proposed method and radiographic film showed excellent agreement of the radiation field. The effect of varying monitor units and light exposure time was tested and found to be very small. Radiation and light field sizes were determined with an uncertainty of less than 1 mm, and light and crosshair centers were determined within 0.1 mm.Conclusions: A new method was developed to digitally determine the radiation and light field size using CR photo-stimulable phosphor plates. The method is quick and reproducible, allowing for the streamlined and robust assessment of light and radiation field coincidence, with no observer interpretation needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative Electron Nanodiffraction.

This Final report summarizes progress under this award for the final reporting period 2002 - 2013 in our development of quantitive electron nanodiffraction to materials problems, especially devoted to atomistic processes in semiconductors and electronic oxides such as the new artificial oxide multilayers, where our microdiffraction is complemented with energy-loss spectroscopy (ELNES) and aberration-corrected STEM imaging (9). The method has also been used to map out the chemical bonds in the important GaN semiconductor (1) used for solid state lighting, and to understand the effects of stacking sequence variations and interfaces in digital oxide superlattices (8). Other projects include the development of a laser-beam Zernike phase plate for cryo-electron microscopy (5) (based on the Kapitza-Dirac effect), work on reconstruction of molecular images using the scattering from many identical molecules lying in random orientations (4), a review article on space-group determination for the International Tables on Crystallography (10), the observation of energy-loss spectra with millivolt energy resolution and sub-nanometer spatial resolution from individual point defects in an alkali halide, a review article for the Centenary of X-ray Diffration (17) and the development of a new method of electron-beam lithography (12). We briefly summarize here the work on GaN, on oxide superlattice ELNES, and on lithography by STEM.

36 MATERIALS SCIENCE↗

Droplet bioprinting of acellular and cell-laden structures at high-resolutions

Advances in digital light projection(DLP) based (bio) printers have made printing of intricate structures at high resolution possible using a wide range of photosensitive bioinks. A typical setup of a DLP bioprinter includes a vat or reservoir filled with liquid bioink, which presents challenges in terms of cost associated with bioink synthesis, high waste, and gravity-induced cell settling, contaminations, or variation in bioink viscosity during the printing process. Here, we report a vat-free, low-volume, waste-free droplet bioprinting method capable of rapidly printing 3D soft structures at high resolution using model bioinks and model cells. A multiphase many-body dissipative particle dynamics model was developed to simulate the dynamic process of droplet-based DLP printing and elucidate the roles of surface wettability and bioink viscosity. Process variables such as light intensity, photo-initiator concentration, and bioink formulations were optimized to print 3D soft structures (∼0.4–3 kPa) with a typical layer thickness of 50 µm, an XY resolution of 38 ± 1.5 μm and Z resolution of 237 ± 5.4 µm. To demonstrate its versatility, droplet bioprinting was used to print a range of acellular 3D structures such as a lattice cube, a Mayan pyramid, a heart-shaped structure, and a microfluidic chip with endothelialized channels. Droplet bioprinting, performed using model C3H/10T1/2 cells, exhibited high viability (90%) and cell spreading. Additionally, microfluidic devices with internal channel networks lined with endothelial cells showed robust monolayer formation while osteoblast-laden constructs showed mineral deposition upon osteogenic induction. Overall, droplet bioprinting could be a low-cost, no-waste, easy-to-use, method to make customized bioprinted constructs for a range of biomedical applications.

DLP↗

Three Dimensional Mapping of Nicle Oxidation States Using Full Field Xray Absorption Near Edge Structure Nanotomography

The reduction-oxidation cycling of the nickel-based oxides in composite solid oxide fuel cells and battery electrodes is directly related to cell performance. A greater understanding of nickel redox mechanisms at the microstructural level can be achieved in part using transmission x-ray microscopy (TXM) to explore material oxidation states. X-ray nanotomography combined with x-ray absorption near edge structure (XANES) spectroscopy has been applied to study samples containing distinct regions of nickel and nickel oxide (NiO) compositions. Digitally processed images obtained using TXM demonstrate the three-dimensional chemical mapping and microstructural distribution capabilities of full-field XANES nanotomography.

30 DIRECT ENERGY CONVERSION↗

US Veteran Gets a Facelift

Idaho National Laboratory's Advanced Test Reactor (ATR) has received replacement instrumentation and control systems - the process distributed control system (DCS) and the console display system (CDS), which included a replacement annunciator subsystem. The new systems offer the latest software and technology advancements, ensuring the availability of the reactor for future energy research. ATR, a pressurized, light water moderated 250 MW materials test reactor, became operational in 1965. In the early 1990s, after nearly thirty years of analogue/pneumatic controls, the laboratory upgraded ATR to digital-based instrumentation and control systems. By 2007, the equipment and technology used in these digital systems were reaching the end of their lifecycle. The systems component failure rates were on a rise, while vendor support and parts availability were declining. With current projections and plans for operating ATR into 2040, modernization of the reactor's infrastructure is necessary to maintain reliability and efficiency. As a result, the Idaho National Laboratory and the U.S. Department of Energy (DOE) invested more than $13 million in a four-year project to replace ATR's instrumentation and control systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A BIM-based system for demolition and renovation waste estimation and planning

Highlights: ► We developed a waste estimation system leveraging the BIM technology. ► The system can calculate waste disposal charging fee and pick-up truck demand. ► We presented an example scenario demonstrating this system. ► Automatic, time-saving and wide applicability are the features of the system. - Abstract: Due to the rising worldwide awareness of green environment, both government and contractors have to consider effective construction and demolition (C and D) waste management practices. The last two decades have witnessed the growing importance of demolition and renovation (D and R) works and the growing amount of D and R waste disposed to landfills every day, especially in developed cities like Hong Kong. Quantitative waste prediction is crucial for waste management. It can enable contractors to pinpoint critical waste generation processes and to plan waste control strategies. In addition, waste estimation could also facilitate some government waste management policies, such as the waste disposal charging scheme in Hong Kong. Currently, tools that can accurately and conveniently estimate the amount of waste from construction, renovation, and demolition projects are lacking. In the light of this research gap, this paper presents a building information modeling (BIM) based system that we have developed for estimation and planning of D and R waste. BIM allows multi-disciplinary information to be superimposed within one digital building model. Our system can extract material and volume information through the BIM model and integrate the information for detailed waste estimation and planning. Waste recycling and reuse are also considered in our system. Extracted material information can be provided to recyclers before demolition or renovation to make recycling stage more cooperative and more efficient. Pick-up truck requirements and waste disposal charging fee for different waste facilities will also be predicted through our system. The results could provide alerts to contractors ahead of time at project planning stage. This paper also presents an example scenario with a 47-floor residential building in Hong Kong to demonstrate our D and R waste estimation and planning system. As the BIM technology has been increasingly adopted in the architectural, engineering and construction industry and digital building information models will likely to be available for most buildings (including historical buildings) in the future, our system can be used in various demolition and renovation projects and be extended to facilitate project control.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

INDUSTRIAL CONTROL SYSTEM CYBER SECURITY: QUESTIONS AND ANSWERS RELEVANT TO NUCLEAR FACILITIES, SAFEGUARDS AND SECURITY

Typical questions surrounding industrial control system (ICS) cyber security always lead back to: What could a cyber attack do to my system(s) and; how much should I worry about it? These two leading questions represent only a fraction of questions asked when discussing cyber security as it applies to any program, company, business, or organization. The intent of this paper is to open a dialog of important pertinent questions and answers that managers of nuclear facilities engaged in nuclear facility security and safeguards should examine, i.e., what questions should be asked; and how do the answers affect an organization's ability to effectively safeguard and secure nuclear material. When a cyber intrusion is reported, what does that mean? Can an intrusion be detected or go un-noticed? Are nuclear security or safeguards systems potentially vulnerable? What about the digital systems employed in process monitoring, and international safeguards? Organizations expend considerable efforts to ensure that their facilities can maintain continuity of operations against physical threats. However, cyber threats particularly on ICSs may not be well known or understood, and often do not receive adequate attention. With the disclosure of the Stuxnet virus that has recently attacked nuclear infrastructure, many organizations have recognized the need for an urgent interest in cyber attacks and defenses against them. Several questions arise including discussions about the insider threat, adequate cyber protections, program readiness, encryption, and many more. These questions, among others, are discussed so as to raise the awareness and shed light on ways to protect nuclear facilities and materials against such attacks.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optics-Free Chip-Scale Intraoperative Imaging Using NIR-Excited Upconverting Nanoparticles

Here we present an optics-free CMOS image sensor that incorporates a novel time-gated dual-photodiode pixel design to allow filter- and lens-less image acquisition of near-infrared-excited (NIR-excited) upconverting nanoparticles. Recent biomedical advances have highlighted the benefits of NIR excitation, but NIR interaction with silicon has remained a challenge, even with high-performance optical blocking filters. Using a secondary diode and a dual-photodiode design, this sensor is able to remove the 100s of mV of NIR background on pixels and bring it down to single-digit mV level, nearing its noise floor of 2.2 mV rms, not achievable with any optical filter. Non-linear effects of background cancellation using the diode pair has been mitigated using an initial one-time pixel-level curve fitting and calibration in a post-processing setting. This imager comprises a highly linear 11 fF metal-oxide-metal (MOM) capacitor and includes integrated angle-selective gratings to reject oblique light and enhance sharpness. Each pixel also includes two distinct correlated double sampling schemes, to remove low frequency flicker noise and systematic offset in the datapath. We demonstrate the performance of this imager using pulsed NIR-excited upconverting nanoparticles on standard United-States-Air-Force (USAF) resolution targets and achieve an SNR of 15 dB, while keeping NIR background below 6 mV. This 36-by-80-pixel array measures only 2.3 mm by 4.8 mm and can be thinned down to 25 µm, allowing it to become surgically compatible with intraoperative instruments and equipment, while remaining optics-free.

42 ENGINEERING↗

Structured light scanning artifact-based performance study

Structured light scanning is used to create a digital twin of a manufactured part, where features are extracted to determine if the part meets the designer’s intent and required tolerances. This paper describes repeatability and reproducibility analyses for a commercially-available structured light scanning system and measurement artifact. The repeatability study used five repeated scans at 15 measurement positions. Repeatability was assessed by randomly selecting one of the five scans at each of the 15 positions and creating a part mesh. This process was performed 50 times and the statistics for the dimension variations were calculated to isolate the scanning effects only. The same sequence was then performed for 10 of the 15 positions and five of the 15 positions to evaluate the repeatability sensitivity to the number of measurement positions. Reproducibility was assessed by selecting 15 positions to create a mesh and repeating the 15-position measurement sequence 10 times using different positions for each mesh construction. The statistics for the dimension variations were then calculated. This incorporated the effects of both scanning and the position and orientation of the part relative to the scanner. This sequence was repeated for 10-position and five-position scans to evaluate the corresponding sensitivity. Finally, the artifact dimensions from structured light scanning were compared to coordinate measuring machine measurements of the same features.

42 ENGINEERING↗

Subaru Spectroscopy of SDSS-II Supernovae

The Sloan Digital Sky Survey II (SDSS-II) Supernova Survey discovered Type Ia supernovae (SNe Ia) in an almost unexplored intermediate redshift range of $0.05 < z < 0.4$ and provided densely sampled multi-color light curves for SN candidates. Followup spectroscopy of this survey was carried out with the Subaru telescope and spectra of 71 SN Ia candidates were obtained. One spectrum was observed per candidate except for a peculiar variable. This paper presents the method for processing these spectra. The observed wavelength ranges of our spectra are 4000 to 9000 {\AA} for Year 2005 and 3600 to 9000 {\AA} for Year 2006. Most SN Ia spectra have signal to noise ratios (S/N) between 4 and 10 per 2 {\AA} averaged over the entire wavelength region. We developed a new code to extract the SN spectral component from spectra contaminated by the host galaxy. Of 71 SN Ia candidates, 59 are identified as normal SNe Ia and 3 are peculiar SNe Ia. The range of spectral phases varies from -7 days to +30 days from maximum brightness. There are also 7 SNe II, 1 possible hypernova and 1 AGN.

79 ASTRONOMY AND ASTROPHYSICS↗

All-optical image denoising using a diffractive visual processor

Abstract Image denoising, one of the essential inverse problems, targets to remove noise/artifacts from input images. In general, digital image denoising algorithms, executed on computers, present latency due to several iterations implemented in, e.g., graphics processing units (GPUs). While deep learning-enabled methods can operate non-iteratively, they also introduce latency and impose a significant computational burden, leading to increased power consumption. Here, we introduce an analog diffractive image denoiser to all-optically and non-iteratively clean various forms of noise and artifacts from input images – implemented at the speed of light propagation within a thin diffractive visual processor that axially spans <250 × λ, where λ is the wavelength of light. This all-optical image denoiser comprises passive transmissive layers optimized using deep learning to physically scatter the optical modes that represent various noise features, causing them to miss the output image Field-of-View (FoV) while retaining the object features of interest. Our results show that these diffractive denoisers can efficiently remove salt and pepper noise and image rendering-related spatial artifacts from input phase or intensity images while achieving an output power efficiency of ~30–40%. We experimentally demonstrated the effectiveness of this analog denoiser architecture using a 3D-printed diffractive visual processor operating at the terahertz spectrum. Owing to their speed, power-efficiency, and minimal computational overhead, all-optical diffractive denoisers can be transformative for various image display and projection systems, including, e.g., holographic displays.

36 MATERIALS SCIENCE↗

Measuring Thickness-Dependent Relative Light Yield and Detection Efficiency of Scintillator Screens

Digital camera-based neutron imaging systems consisting of a neutron scintillator screen optically coupled to a digital camera are the most common digital neutron imaging system used in the neutron imaging community and are available at any state-of-the-art imaging facility world-wide. Neutron scintillator screens are the integral component of these imaging system that directly interacts with the neutron beam and dictates the neutron capture efficiency and image quality limitations of the imaging system. This work describes a novel approach for testing neutron scintillators that provides a simple and efficient way to measure relative light yield and detection efficiency over a range of scintillator thicknesses using a single scintillator screen and only a few radiographs. Additionally, two methods for correlating the screen thickness to the measured data were implemented and compared. An example 6LiF:ZnS scintillator screen with nominal thicknesses ranging from 0–300 μm was used to demonstrate this approach. The multi-thickness screen and image and data processing methods are not exclusive to neutron scintillator screens but could be applied to X-ray imaging as well. This approach has the potential to benefit the entire radiographic imaging community by offering an efficient path forward for manufacturers to develop higher-performance scintillators and for imaging facilities and service providers to determine the optimal screen parameters for their particular beam and imaging system.

42 ENGINEERING↗

A Multi-Layer Phoswich Radioxenon Detection System, Reporting Period 07/01/07 - 09/30/07

During this quarter, the detector manufacturer (Saint-Gobain) delivered one side of the prototype two-channel phoswich detector (XEPHWICH). Once received, our Digital Pulse Processor (DPP1, 12-bit/100 MHz) was employed to capture and digitally process phoswich pulses from laboratory radioactive sources. Our previous pulse shape discrimination algorithm was modified by utilizing three trapezoidal digital filters. This algorithm provides a two-dimensional plot in which the pulse shapes of interest are classified and then can be well identified. The preliminary experimental results will be presented at the 2007 Informal Xenon Monitoring Workshop. The DPP2 (two-channel, 12-bit/ 250 MHz Digital Pulse Processor) is at the prototyping stage. The analog sections have been designed, prototyped and tested. A 6-layer Printed Circuit Board (PCB) was designed, ordered and delivered. The board components were ordered and are now being assembled and examined for proper functionality. In addition, the related FPGA hardware description code (using VHDL) is under development and simulation. Additionally, our researchers have been studying materials regarding wavelet transforms for incorporation into the project. Wavelet transform is an interesting tool for signal processing; one use for our purpose would be to de-noise the detector signal and to express the signal in a few coefficients for signal compression and increased speed. Light capture efficiency modeling and analysis was performed on the XEPHWICH design. Increased understanding of the modeling software was obtained by the discovery of a bug and successful workaround techniques with the DETECT2000 software. Further modeling and plot generation experience was had by the continued use of CERN's ROOT and GEANT4 software packages. Simulations have been performed to compare the output of points versus planes in light capture efficiency. An additional simulation was made with a runtime that was an order-of-magnitude greater than previous simulations, to confirm convergence of the solutions provided by our software methods. We have initiated our investigation into the radon signature expected in our XEPHWICH system. We intend to utilize this signature to confirm earth movement, in the event of an underground nuclear explosion, by continuously monitoring radon levels and noting increases in radon concentration in conjunction with increased levels of radioxenons. The research group is also designing and constructing a fission chamber to be used for the collection of radioxenon gases following neutron bombardment of HEU in the Oregon State University TRIGA reactor. To this point, we have completed milling the aluminum housing and have modeled fission product nuclide production associated with the fissioning of HEU. Additionally, the students have been busy compiling the appropriate information in preparation for irradiation approvals. Using beta spectra of three initial nuclides collected on the prototype phoswich detector, spectral identification by a preliminary neural network was compared to that of solvers of a linear system of equations. Pre-processing in areas such as smoothing and endpoint identification is also being investigated as a means of improving spectral identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correcting incompatible DN values and geometric errors in nighttime lights time series images

The Defense Meteorological Satellite Program’s Operational Linescan System (DMSP-OLS) nighttime lights imagery has proven to be a powerful remote sensing tool to monitor urbanization and assess socioeconomic activities at large scales. However, the existence of incompatible digital number (DN) values and geometric errors severely limit application of nighttime light image data on multi-year quantitative research. In this study we extend and improve previous studies on inter-calibrating nighttime lights image data to obtain more compatible and reliable nighttime lights time series (NLT) image data for China and the United States (US) through four steps: inter-calibration, geometric correction, steady increase adjustment, and population data correction. We then use gross domestic product (GDP) data to test the processed NLT image data indirectly and find that sum light (summed DN value of pixels in a nighttime light image) maintains apparent increase trends with relatively large GDP growth rates but does not increase or decrease with relatively small GDP growth rates. As nighttime light is a sensitive indicator for economic activity, the temporally consistent trends between sum light and GDP growth rate imply that brightness of nighttime lights on the ground is correctly represented by the processed NLT image data. Finally, through analyzing the corrected NLT image data from 1992 to 2008, we find that China experienced apparent nighttime lights development in 1992-1997 and 2001-2008 respectively and the US suffered from nighttime lights decay in large areas after 2001.

47 OTHER INSTRUMENTATION↗

Exploring diagnostic capabilities for application to new photovoltaic technologies.

Explosive growth in photovoltaic markets has fueled new creative approaches that promise to cut costs and improve reliability of system components. However, market demands require rapid development of these new and innovative technologies in order to compete with more established products and capture market share. Often times diagnostics that assist in R&D do not exist or have not been applied due to the innovative nature of the proposed products. Some diagnostics such as IR imaging, electroluminescence, light IV, dark IV, x-rays, and ultrasound have been employed in the past and continue to serve in development of new products, however, innovative products with new materials, unique geometries, and previously unused manufacturing processes require additional or improved test capabilities. This fast-track product development cycle requires diagnostic capabilities to provide the information that confirms the integrity of manufacturing techniques and provides the feedback that can spawn confidence in process control, reliability and performance. This paper explores the use of digital radiography and computed tomography (CT) with other diagnostics to support photovoltaic R&D and manufacturing applications.

99 GENERAL AND MISCELLANEOUS↗

Exploring the Psychometrics of Common Post-Scenario Human Factors Questionnaires of Workload, Situation Awareness, and Perceived Difficulty

Abstract: The United States (U.S.) Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) program has the primary mission of sustaining operation of the existing commercial nuclear power plants (NPPs) through a multi-pathway approach in conducting research and development (R&D). In this effort, the role of human factors engineering (HFE) has been an integral in ensuring new digital upgrades that are part of the overall main control room modernization strategy for various U.S. NPPs optimize human-system performance and do not introduce new human failure modes. In this process, testing and evaluation of concept (i.e., prototype) human machine interfaces (HMIs) are done in operator-in-the-loop studies at various stages of the HFE modification process, such as during design and verification and validation (V&V) [1]. During these studies, licensed operators go through select scenarios using a testbed, such as a full-scale simulator or at a NPP’s training simulator, to identify potential usability issues and provide general design feedback regarding the new digital HMIs. Human-system performance is measured and evaluated through a range of objective and self-report measures that capture aspects of plant performance, task performance, workload, situation awareness, and anthropometric and ergonomic concerns [2]. The use of post-scenario questionnaires is an acceptable method for gathering measures of workload and situation awareness. To this end, the NASA-Task Load Index (TLX) [e.g., 3, 4, & 5] and Situation Awareness Rating Technique (SART) [e.g., 6 & 7] are common standardized questionnaires used for evaluating workload and situation awareness, respectively. When combined, these questionnaires consist of a total of 15 questions, each using a different rating scale. Debriefs are also done through interviews with operators to gather design insight after each scenario. Since operator- and training simulator-time is limited, a concern during this post-scenario period of operator-in-the-loop studies is the limited time available to run scenarios, administer post-scenario questionnaires, and debrief within the allotted simulator time. To address this potential problem, this paper explores the psychometric characteristics of NASA-TLX, SART, and a common one-question post-scenario usability questionnaire (i.e., the single ease question – SEQ [8]) in effort to inform future development of a condensed questionnaire that captures aspects of workload and situation awareness. This exploratory work uses data from four different operator-in-the-loop studies completed under prior LWRS operator-in-the-loop studies. Findings from this paper should support future development of a consolidated questionnaire that may be used in operator-in-the-loop studies, when time is compressed, that conforms to the HFE scientific and regulatory requirements set for NPP control room modernization.

99 GENERAL AND MISCELLANEOUS↗