Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diagnosability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Diagnosing Bias in Modeled Soil Moisture/runoff Coefficient Correlation Using the SMAP Level 4 Soil Moisture Product

The physical parameterization of key processes in land surface models (LSMs) remains uncertain, and new techniques are required to evaluate LSM accuracy over coarse spatial scales. Given the role of soil moisture in the partitioning of surface water fluxes (between infiltration, runoff and evapotranspiration), surface soil moisture (SSM) estimates represent an important observational benchmark for such evaluations. Here, we apply SSM estimates from the NASA Soil Moisture Active Passive Level 4 product (SMAP_L4) to diagnose bias in the coupling between SSM and surface runoff for multiple Noah-Multiple Physics (Noah-MP) LSM parameterization cases. Results demonstrate that Noah-MP surface runoff parameterizations often underestimate the coupling strength between pre-storm SSM and the event-scale runoff coefficient (RC; defined as the ratio between event-scale streamflow and precipitation volumes). This bias squanders RC information contained in pre-storm SSM and reduces RC estimation skill. Such bias can be quantified against an observational benchmark calculated using streamflow observations and SMAP_L4 SSM and applied to explain a substantial fraction of the observed basin-to-basin (and case-to-case) variability in the skill of event-scale Noah-MP RC estimates. Based on this concept, a novel case selection strategy for ungauged basins is introduced and demonstrated to successfully identify poorly performing Noah-MP parameterization cases.

SSM↗

Assessment of radiography for diagnosing short wavelength instability growth and mix in NIF ignition capsules.

Understanding and controlling hydrodynamic instabilities is critical to achieving ignition at National Ignition Facility (NIF). High resolution x-ray radiography of a NIF capsule may be able to measure key aspects of short wavelength instability growth including time dependent areal density variations, the dominant wavelength of growth, amount of growth from isolated capsule defects on the ablator and ice surfaces, and growth of perturbations as a result of the fill tube or dust contaminants. Radiography of the capsule limb may also place constraints on the width of the ice/ablator mix layer. Measurement of these various observables are important to determine what effect target design changes has on instability growth and to validate code predictions. We present an analysis of 2D and 3D HYDRA simulations and demonstrate how radiography can be used to diagnose signatures of mix in NIC capsules.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron spectrometry - An essential tool for diagnosing implosions at the National Ignition Facility

DT neutron yield (Y{sub n}), ion temperature (T{sub i}) and down-scatter ratio (dsr) determined from measured neutron spectra are essential metrics for diagnosing the performance of Inertial Confinement Fusion (ICF) implosions at the National Ignition Facility (NIF). A suite of neutron-Time-Of-Flight (nTOF) spectrometers and a Magnetic Recoil Spectrometer (MRS) have been implemented in different locations around the NIF target chamber, providing good implosion coverage and the redundancy required for reliable measurements of Yn, Ti and dsr. From the measured dsr value, an areal density ({rho}R) is determined from the relationship {rho}R{sub tot} (g/cm{sup 2}) = (20.4 {+-} 0.6) x dsr{sub 10-12 MeV}. The proportionality constant is determined considering implosion geometry, neutron attenuation and energy range used for the dsr measurement. To ensure high accuracy in the measurements, a series of commissioning experiments using exploding pushers have been used for in situ calibration. The spectrometers are now performing to the required accuracy, as indicated by the good agreement between the different measurements over several commissioning shots. In addition, recent data obtained with the MRS and nTOFs indicate that the implosion performance of cryogenically layered DT implosions, characterized by the experimental Ignition Threshold Factor (ITFx) which is a function of dsr (or fuel {rho}R) and Y{sub n}, has improved almost two orders of magnitude since the first shot in September, 2010.

42 ENGINEERING↗

Automated diagnostic kiosk for diagnosing diseases

An automated and autonomous diagnostic apparatus that is capable of dispensing collection vials and collections kits to users interesting in collecting a biological sample and submitting their collected sample contained within a collection vial into the apparatus for automated diagnostic services. The user communicates with the apparatus through a touch-screen monitor. A user is able to enter personnel information into the apparatus including medical history, insurance information, co-payment, and answer a series of questions regarding their illness, which is used to determine the assay most likely to yield a positive result. Remotely-located physicians can communicate with users of the apparatus using video tele-medicine and request specific assays to be performed. The apparatus archives submitted samples for additional testing. Users may receive their assay results electronically. Users may allow the uploading of their diagnoses into a central databank for disease surveillance purposes.

60 APPLIED LIFE SCIENCES↗

Diagnosing Undersampling in Monte Carlo Eigenvalue and Flux Tally Estimates

This study explored the impact of undersampling on the accuracy of tally estimates in Monte Carlo (MC) calculations. Steady-state MC simulations were performed for models of several critical systems with varying degrees of spatial and isotopic complexity, and the impact of undersampling on eigenvalue and fuel pin flux/fission estimates was examined. This study observed biases in MC eigenvalue estimates as large as several percent and biases in fuel pin flux/fission tally estimates that exceeded tens, and in some cases hundreds, of percent. This study also investigated five statistical metrics for predicting the occurrence of undersampling biases in MC simulations. Three of the metrics (the Heidelberger-Welch RHW, the Geweke Z-Score, and the Gelman-Rubin diagnostics) are commonly used for diagnosing the convergence of Markov chains, and two of the methods (the Contributing Particles per Generation and Tally Entropy) are new convergence metrics developed in the course of this study. These metrics were implemented in the KENO MC code within the SCALE code system and were evaluated for their reliability at predicting the onset and magnitude of undersampling biases in MC eigenvalue and flux tally estimates in two of the critical models. Of the five methods investigated, the Heidelberger-Welch RHW, the Gelman-Rubin diagnostics, and Tally Entropy produced test metrics that correlated strongly to the size of the observed undersampling biases, indicating their potential to effectively predict the size and prevalence of undersampling biases in MC simulations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Compounds for use in diagnosing and treating melanoma, including metastatic melanoma and methods related to same

The present invention is directed to novel non-invasive diagnostic tools/compounds comprising a cyclic peptide wherein the compound binds to a MSH receptor to image and treat cancers, especially, melanoma, including metastatic melanoma in vivo. The present invention represents a clear advance in the art which presently relies on tissue biopsy for diagnoses of these cancers. The novel imaging probes are capable of detecting cancerous melanoma cells, as well as their metastatic spread in tissues. This represents a quantum step forward in the diagnosis and treatment of melanoma, including metastatic melanoma using non-invasive molecular imaging techniques. The novel probes of the present invention will also be useful to initiate therapy for melanoma as well as monitor patients response to chemotherapy treatments and other interventions or therapies used in the treatment of melanoma/metastatic melanoma. Compounds according to the present invention may be used as diagnostic tools for a number of conditions and diseases states as well as therapeutic agents for treating such conditions and disease states.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compounds for use in diagnosing and treating melanoma, including metastatic melanoma and methods related to same

The present invention is directed to novel non-invasive diagnostic tools/compounds comprising a cyclic peptide wherein the compound binds to a MSH receptor to image and treat cancers, especially, melanoma, including metastatic melanoma in vivo. The present invention represents a clear advance in the art which presently relies on tissue biopsy for diagnoses of these cancers. The novel imaging probes are capable of detecting cancerous melanoma cells, as well as their metastatic spread in tissues. This represents a quantum step forward in the diagnosis and treatment of melanoma, including metastatic melanoma using non-invasive molecular imaging techniques. The novel probes of the present invention will also be useful to initiate therapy for melanoma as well as monitor patients response to chemotherapy treatments and other interventions or therapies used in the treatment of melanoma/metastatic melanoma. Compounds according to the present invention may be used as diagnostic tools for a number of conditions and diseases states as well as therapeutic agents for treating such conditions and disease states.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compositions for use in diagnosing and treating melanoma, including metastatic melanoma and methods related to same

The present invention is directed to novel non-invasive diagnostic tools/compounds comprising a cyclic peptide wherein the compound binds to a MSH receptor to image and treat cancers, especially, melanoma, including metastatic melanoma in vivo. The present invention represents a clear advance in the art which presently relies on tissue biopsy for diagnoses of these cancers. The novel imaging probes are capable of detecting cancerous melanoma cells, as well as their metastatic spread in tissues. This represents a quantum step forward in the diagnosis and treatment of melanoma, including metastatic melanoma using non-invasive molecular imaging techniques. The novel probes of the present invention will also be useful to initiate therapy for melanoma as well as monitor patients response to chemotherapy treatments and other interventions or therapies used in the treatment of melanoma/metastatic melanoma. Compounds according to the present invention may be used as diagnostic tools for a number of conditions and diseases states as well as therapeutic agents for treating such conditions and disease states.

Miao, Yubin↗

Diagnosing undersampling in Monte Carlo eigenvalue and flux tally estimates - 14515

This study explored the impact of undersampling on the accuracy of tally estimates in Monte Carlo (MC) calculations. Steady-state MC simulations were performed for models of several critical systems with varying degrees of spatial and isotopic complexity, and the impact of undersampling on eigenvalue and fuel pin flux/fission estimates was examined. This study observed biases in MC eigenvalue estimates as large as several percent and biases in fuel pin flux/fission tally estimates that exceeded tens, and in some cases hundreds, of percent. This study also investigated five statistical metrics for predicting the occurrence of undersampling biases in MC simulations. Three of the metrics (the Heidelberger-Welch RHW, the Geweke Z-Score, and the Gelman-Rubin diagnostics) are commonly used for diagnosing the convergence of Markov chains, and two of the methods (the Contributing Particles per Generation and Tally Entropy) are new convergence metrics developed in the course of this study. These metrics were implemented in the KENO MC code within the SCALE code system and were evaluated for their reliability at predicting the onset and magnitude of undersampling biases in MC eigenvalue and flux tally estimates in two of the critical models. Of the five methods investigated, the Heidelberger-Welch RHW, the Gelman-Rubin diagnostics, and Tally Entropy produced test metrics that correlated strongly to the size of the observed undersampling biases, indicating their potential to effectively predict the size and prevalence of undersampling biases in MC simulations. (authors)

42 ENGINEERING↗

Prelude to Simulation Diagnostics in MOOSE: Diagnosing Meshes

As finite element simulations increase in complexity, so does the need for high quality meshes. Without proper diagnostics, issues pertaining to poor mesh quality or improper mesh construction may go undetected, causing simulations to fail unexpectedly. This paper details the new mesh diagnostic system available in MOOSE, which provides users with the tools to inspect mesh quality for both externally and internally generated meshes. This system can detect issues arising from element volume size, non-conformal elements, intersecting edges, missing sidesets, as well as other common mesh issues. As meshes increase in size and complexity, such issues become more difficult to diagnose through visual inspection alone.

99 - GENERAL AND MISCELLANEOUS↗

Diagnosing causes of cloud parameterization deficiencies using ARM measurements over SGP site

Decade-long continuous surface-based measurements at Great Southern Plains (SGP) collected by the US Department of Energy’s Atmospheric Radiation Measurement (ARM) Climate Research Facility are first used to evaluate the three major reanalyses (i.e., ERA-Interim, NCEP/NCAR Reanalysis I and NCEP/DOE Reanalysis II) to identify model biases in simulating surface shortwave cloud forcing and total cloud fraction. The results show large systematic lower biases in the modeled surface shortwave cloud forcing and cloud fraction from all the three reanalysis datasets. Then we focus on diagnosing the causes of these model biases using the Active Remote Sensing of Clouds (ARSCL) products (e.g., vertical distribution of cloud fraction, cloud-base and cloud-top heights, and cloud optical depth) and meteorological measurements (temperature, humidity and stability). Efforts are made to couple cloud properties with boundary processes in the diagnosis.

54 ENVIRONMENTAL SCIENCES↗

Diagnosing Cloud Biases in the GFDL AM3 Model With Atmospheric Classification

In this paper, we define a set of 21 atmospheric states, or recurring weather patterns, for a region surrounding the Atmospheric Radiation Measurement Program's Southern Great Plains site using an iterative clustering technique. The states are defined using dynamic and thermodynamic variables from reanalysis, tested for statistical significance with cloud radar data from the Southern Great Plains site, and are determined every 6 h for 14 years, creating a time series of atmospheric state. The states represent the various stages of the progression of synoptic systems through the region (e.g., warm fronts, warm sectors, cold fronts, cold northerly advection, and high-pressure anticyclones) with a subset of states representing summertime conditions with varying degrees of convective activity. We use the states to classify output from the NOAA/Geophysical Fluid Dynamics Laboratory AM3 model to test the model's simulation of the frequency of occurrence of the states and of the cloud occurrence during each state. The model roughly simulates the frequency of occurrence of the states but exhibits systematic cloud occurrence biases. Comparison of observed and model-simulated International Satellite Cloud Climatology Project histograms of cloud top pressure and optical thickness shows that the model lacks high thin cloud under all conditions, but biases in thick cloud are state-dependent. Frontal conditions in the model do not produce enough thick cloud, while fair-weather conditions produce too much. Finally, we find that increasing the horizontal resolution of the model improves the representation of thick clouds under all conditions but has little effect on high thin clouds. However, increasing resolution also changes the distribution of states, causing an increase in total cloud occurrence bias.

54 ENVIRONMENTAL SCIENCES↗

Diagnosing lepton-nonuniversality in b → sℓℓ

Ratios of branching fractions of semileptonic B decays, (B→Hμμ) over (B→Hee) with H=K, K*,X s , K 0 (1430),$\phi$,… are sensitive probes of lepton universality. In the Standard Model, the underlying flavor changing neutral current process b→sℓℓ is lepton flavor universal. However models with new flavor violating physics above the weak scale can give substantial non-universal contributions. The leading contributions from such new physics can be parametrized by effective dimension six operators involving left- or right-handed quarks. We show that in the double ratios R X s /R K , R K* /R K and R $\phi$ /R K the dependence on new physics coupling to left-handed quarks cancels out. Thus a measurement of any of these double ratios is a clean probe of flavor nonuniversal physics coupling to right-handed quarks. We also point out that the observables R X s , R K* , R K 0(1430) and R$\phi$ depend on the same combination of Wilson coefficients and therefore satisfy simple consistency relations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A guide to diagnosing colored resonances at hadron colliders

We present a comprehensive study on how to distinguish the properties of heavy dijet resonances at hadron colliders. A variety of spins, chiral couplings, charges, and QCD color representations are considered. Distinguishing the different color representations is particularly difficult at hadron colliders. To determine the QCD color structure, we consider a third jet radiated in a resonant dijet event. We show that the relative rates of three-jet versus two-jet processes are sensitive to the color representation of the resonance. We also show analytically that the antennae radiation pattern of soft radiation depends on the color structure of dijet events and develops an observable that is sensitive to the antennae patterns. Finally, we exploit a Convolutional Neural Network with Machine Learning techniques to differentiate the radiation patterns from different colored resonances and find encouraging results to discriminate them. We demonstrate our results numerically at a 14 TeV LHC, and the methodology presented here should be applicable to other future hadron colliders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Liver metastases of neuroendocrine tumors: is it possible to diagnose different histologic subtypes depending on multiphasic CT features?

Purpose: To assess and compare the multiphasic computed tomography (CT) features of neuroendocrine tumor (NET) liver metastases and to investigate the possibility to predict the histologic subtype of the primary tumor. Materials and methods: Between January 2013 and December 2017 patients with biopsy proven NET with at least one liver metastasis who underwent multiphasic CT were enrolled in this study. All cases were acquired using a standardized multiphasic liver CT protocol, arterial, portal, and hepatic venous phases were obtained. Images were retrospectively analyzed in consensus by two abdominal radiologists blinded to clinical data and histologic subtype. The size, number, and location of lesions were noted. Enhancement patterns of each lesion on arterial, portal, and hepatic venous phases were assessed. For quantitative analysis, CT attenuation of tumors, liver parenchyma, and aorta were measured using a circular region of interest (ROI) on arterial, portal, and hepatic venous phases for reflecting the blood supply of the tumor. Tumor-to-aorta and tumor-to-liver ratio were calculated in all three phases. Differences between subtypes of NET liver metastases were studied using ROC analysis of clustered data. Results: A total of 255 neuroendocrine tumor liver metastases divided into 101 (39.6%) pancreatic, 60 (23.5%) gastroenteric and 94 (36.8%) lung NET liver metastases were analyzed. Contrast enhancement of lesions was homogeneous in 78% of patients (n = 199), which was significantly more frequent in patients with pancreatic group than in those with gastroenteric origin (n = 90, 89.1% vs. n = 28, 46.7%; p < 0.001). Gastroenteric NET metastases frequently showed heterogeneous enhancement, which was significantly higher than in the other two groups (50% vs. 3% and 2%). With respect to the location of the primary tumor, the difference in enhancement patterns of the liver lesions was statistically significant (p < 0.001). Pancreatic NET metastases were mostly hyperdense on arterial images and isodense on portal and hepatic venous phase images (79.2%, n = 80). Gastroenteric NET metastases were mostly hyperdense on arterial phase images and hypodense on portal and hepatic venous phase images (n = 28, 46.7%). The most frequent pattern for lung NET metastases was hypoattenuation on all three phase images (n = 44, 46.8%). ROC analysis of clustered data revealed statistically significant differences between pancreatic NET liver metastases, gastroenteric NET liver metastases, and lung NET liver metastases in terms of tumor-to-aorta (T–A) ratio and tumor-to-liver (T–L) ratio (p < 0.001). Conclusion: We observed statistically significant differences in multiphasic CT features (enhancement pattern, T–A ratio, and T–L ratio) between histologic subtypes of NET liver metastases. As the difference in histological subtypes of NET liver metastases results in a different prognosis and different management strategy, these CT features might help to identify the primary tumor when it is not known to ensure accurate tumor staging and to provide optimal treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Can MRI be used to diagnose histologic grade in T1a (< 4 cm) clear cell renal cell carcinomas?

Objective: To assess whether MRI can differentiate low-grade from high-grade T1a cc-RCC. Materials and methods: With IRB approval, 49 consecutive solid < 4 cm cc-RCC (low grade [Grade 1 or 2] N = 38, high grade [Grade 3] N = 11) with pre-operative MRI before nephrectomy were identified between 2013 and 2018. Tumor size, apparent diffusion coefficient (ADC) histogram analysis, enhancement wash-in and wash-out rates, and chemical shift signal intensity index (SI index) were assessed by a blinded radiologist. Subjectively, two blinded Radiologists also assessed for (1) microscopic fat, (2) homogeneity (5-point Likert scale), and (3) ADC signal (relative to renal cortex); discrepancies were resolved by consensus. Outcomes were studied using Chi square, multivariate analysis, logistic regression modeling, and ROC. Inter-observer agreement was assessed using Cohen’s kappa. Results: Tumor size was 24 ± 7 (13–39) mm with no association to grade (p = 0.45). Among quantitative features studied, corticomedullary phase wash-in index (p = 0.015), SI index (p = 0.137), and tenth-centile ADC (p = 0.049) were higher in low-grade tumors. 36.8% (14/38) low-grade tumors versus zero high-grade tumors demonstrated microscopic fat (p = 0.015; Kappa = 0.67). Microscopic fat was specific for low-grade disease (100.0% [71.5–100.0]) with low sensitivity (36.8% [21.8–54.6]). Other subjective features did not differ between groups (p > 0.05). A logistic regression model combining microscopic fat + wash-in index + tenth-centile-ADC yielded area under ROC curve 0.98 (Confidence Intervals 0.94–1.0) with sensitivity/specificity 87.5%/100%. Conclusion: The combination of microscopic fat, higher corticomedullary phase wash-in and higher tenth-centile ADC is highly accurate for diagnosis of low-grade disease among T1a clear cell RCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MRI-guided Wire Localization Surgical Biopsy in an Adolescent Patient with a Difficult to Diagnose Case of Lymphoma

A 17-year-old previously healthy female presented with a progressive soft tissue infiltrative process involving the neck and thorax. Extensive diagnostic evaluation including multiple imaging, laboratory, and biopsy studies was nondiagnostic. Due to an urgent need to establish a diagnosis and several previous nondiagnostic biopsies, she was referred to interventional radiology for MRI-guided wire localization immediately prior to open surgical biopsy. Under general anesthesia, wires were placed in the areas of increased T2 signal within the bilateral splenius capitis muscles using intermittent MRI-guidance followed by immediate surgical biopsy down to the wires. Pathology confirmed the diagnosis of diffuse large B-cell lymphoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗