Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “device operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Parametric optics with whispering-gallery modes

We propose to fabricate a dielectric cavity sustaining high-Q whispering gallery modes from a periodically poled material possessing a quadratic nonlinearity to achieve an efficient interaction among the modes. We show that the periodical poling allows for compensation of both the material and the cavity dispersions that prohibits the nonlinear interaction otherwise. Such a cavity might be a basics element of a family of efficient nonlinear devices operating at a broad range of optical wavelengths.

Maleki, Lute↗

Commercialization of a Direct Methanol Fuel Cell System

This paper describes a major breakthrough in energy technology developed at the Jet Propulsion Laboratory that can be used in a wide variety of portable, remote, and transportation applications without polluting the environment. The status, performance, and design considerations of the JPL non-polluting, direct methanol, fuel cell system for consumer equipment and transportation applications are reported herein. This new fuel cell technology utilizes the direct oxidation of a 3 percent aqueous liquid methanol solution as the fuel and air (O&sub2;) as the oxidant. The only products are CO&sub2; and water. Therefore, because recharging can be accomplished by refueling with methanol, vehicles can enjoy unlimited range and extended use compared to battery operated devices requiring recharging time and power accessibility.

fuel↗

Optical devices for proximity operations study and test report

Operational and physical requirements were investigated for a low-light-level viewing device to be used as a window-mounted optical sight for crew use in the pointing, navigating, stationkeeping, and docking of space vehicles to support space station operations and the assembly of large structures in space. A suitable prototype, obtained from a commercial vendor, was subjected to limited tests to determine the potential effectiveness of a proximity optical device in spacecraft operations. The constructional features of the device are discussed as well as concepts for its use. Tests results show that a proximity optical device is capable of performing low-light-level viewing services and will enhance manned spacecraft operations.

Smith, R. A.↗

Total Ionizing Dose Testing of the Analog Devices’ AD648 Dual Precision Operational Amplifier

The Analog Devices (ADI) AD648 was tested for total ionizing dose response at the Goddard Space Flight Center (GSFC) Radiation Effects Facility (REF) beginning 1 June 2011. This test served as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) could be determined.

Alvin J Boutte↗

Speed-sensing device aids crane operators

So that crane operators can judge payload movements accurately, a friction-driven multilobed cam device energizes a buzzer and indicator lamp in the crane cab. The signal frequency of this speed sensor has a sensitivity to hoist movement of 1/8 inch.

Source record↗

Single chip camera device having double sampling operation

A single chip camera device is formed on a single substrate including an image acquisition portion for control portion and the timing circuit formed on the substrate. The timing circuit also controls the photoreceptors in a double sampling mode in which are reset level is first read and then after an integration time a charged level is read.

Fossum, Eric R.↗

Hydraulic actuator motion limiter ensures operator safety

Device regulates action of hydraulic linkage to control column to minimize hazard to operator. Primary components of device are flow rate control valve, limiter accumulator, and shutoff valve. Limiter may be incorporated into other hydraulic systems to prevent undue wear on hydraulic actuators and associated components.

Steinmetz, C. P.↗

Texas Instruments' virtual phase charge-coupled device (CCD) imager operated in the frontside electron-bombarded mode

The present investigation is concerned with the suitability of the virtual phase CCD imager for frontside detection of electrons up to 25 keV. The investigation has the objective to determine if the imager can be used in the frontside mode with a photocathode to detect very low light levels in astronomical applications, the ultimate goal being individual photon detection. It is found that the standard virtual phase imager will function properly over an extended period at low levels of 20 kV electron irradiation consistent with photon counting applications. The imager can detect individual primary electrons with nearly 100 percent efficiency. However, further studies are needed to determine the mechanisms for the flat band shifts so that the imager design may be modified to eliminate or at least reduce them.

Everett, P.↗

Magnetic-Field-Assisted Terahertz Quantum Cascade Laser Operating up to 225 K

Advances in semiconductor bandgap engineering have resulted in the recent development of the terahertz quantum cascade laser1. These compact optoelectronic devices now operate in the frequency range 1.2-5 THz, although cryogenic cooling is still required2.3. Further progress towards the realization of devices operating at higher temperatures and emitting at longer wavelengths (sub-terahertz quantum cascade lasers) is difficult because it requires maintaining a population inversion between closely spaced electronic sub-bands (1 THz approx. equals 4 meV). Here, we demonstrate a magnetic-field-assisted quantum cascade laser based on the resonant-phonon design. By applying appropriate electrical bias and strong magnetic fields above 16 T, it is possible to achieve laser emission from a single device over a wide range of frequencies (0.68-3.33 THz). Owing to the suppression of inter-landau-level non-radiative scattering, the device shows magnetic field assisted laser action at 1 THz at temperatures up to 215 K, and 3 THz lasing up to 225 K.

Wade, A.↗

Devices and methods of operation thereof for providing stable flow for centrifugal compressors

Centrifugal compressor flow stabilizing devices and methods of operation thereof are disclosed that act upon the flow field discharging from the impeller of a centrifugal compressor and modify the flow field ahead of the diffuser vanes such that flow conditions contributing to rotating stall and surge are reduced or even eliminated. In some embodiments, shaped rods and methods of operation thereof are disclosed, whereas in other embodiments reverse-tangent air injection devices and methods are disclosed.

Skoch, Gary J.↗

Comments on the Operation of Capillary Pumped Loop Devices in Low Gravity

The operation of Capillary Pumped Loops (CPL's) in low gravity has generally been unable to match ground-based performance. The reason for this poorer performance has been elusive. In order to investigate the behavior of a CPL in low-gravity, an idealized, glass CPL experiment was constructed. This experiment, known as the Capillary-driven Heat Transfer (CHT) experiment, was flown on board the Space Shuttle Columbia in July 1997 during the Microgravity Science Laboratory mission. During the conduct of the CHT experiment an unexpected failure mode was observed. This failure mode was a result of liquid collecting and then eventually bridging the vapor return line. With the vapor return line blocked, the condensate was unable to return to the evaporator and dry-out subsequently followed. The mechanism for this collection and bridging has been associated with long wavelength instabilities of the liquid film forming in the vapor return line. Analysis has shown that vapor line blockage in present generation CPL devices is inevitable. Additionally, previous low-gravity CPL tests have reported the presence of relatively low frequency pressure oscillations during erratic system performance. Analysis reveals that these pressure oscillations are in part a result of long wavelength instabilities present in the evaporator pores, which likewise lead to liquid bridging and vapor entrapment in the porous media. Subsequent evaporation to the trapped vapor increases the vapor pressure. Eventually the vapor pressure causes ejection of the bridged liquid. Recoil stresses depress the meniscus, the vapor pressure rapidly increases, and the heated surface cools. The process then repeats with regularity.

Hallinan, K. P.↗

Microwave and millimeter-wave power generation in silicon carbide (SiC) IMPATT devices

There are two points that should be noted. First, in the thermal resistance calculations it is assumed that the device is operating at 773 K while the results of the room temperature simulations are used. This was done because there is not enough information to correctly predict the material parameters at 773 K. Since, in general, device performance degrades with increasing temperature, the cw results are perhaps a bit optimistic. Second, the electric field in these structures gets extremely high and there might be some possibility of tunneling. This was not incorporated into the simulation. Again, this could result in different device operating conditions.

Mehdi, I.↗

BPSK Demodulation Using Digital Signal Processing

A digital communications signal is a sinusoidal waveform that is modified by a binary (digital) information signal. The sinusoidal waveform is called the carrier. The carrier may be modified in amplitude, frequency, phase, or a combination of these. In this project a binary phase shift keyed (BPSK) signal is the communication signal. In a BPSK signal the phase of the carrier is set to one of two states, 180 degrees apart, by a binary (i.e., 1 or 0) information signal. A digital signal is a sampled version of a "real world" time continuous signal. The digital signal is generated by sampling the continuous signal at discrete points in time. The rate at which the signal is sampled is called the sampling rate (f(s)). The device that performs this operation is called an analog-to-digital (A/D) converter or a digitizer. The digital signal is composed of the sequence of individual values of the sampled BPSK signal. Digital signal processing (DSP) is the modification of the digital signal by mathematical operations. A device that performs this processing is called a digital signal processor. After processing, the digital signal may then be converted back to an analog signal using a digital-to-analog (D/A) converter. The goal of this project is to develop a system that will recover the digital information from a BPSK signal using DSP techniques. The project is broken down into the following steps: (1) Development of the algorithms required to demodulate the BPSK signal; (2) Simulation of the system; and (3) Implementation a BPSK receiver using digital signal processing hardware.

Garcia, Thomas R.↗

A Multi-Faceted Approach to Demonstrating Multi-Functional Integrated Medical Devices to Advance Earth-Independent Medical Operations

INTRODUCTION TO MIM DEVICES Multi-functional Integrated Medical (MIM) devices conveniently incorporate multiple medical system capabilities within one device. The NASA Exploration Medical Integrated Product Team (XM-IPT) sponsored a market survey and trade study which identified the Tempus ProTM and the LifeBot 10® as the MIM devices that best met the evaluation criteria of the trade study. The Tempus ProTM (Remote Diagnostic Technologies, Ltd., Philips Corp., Farnborough, UK) and LifeBot 10® (LifeBot Health, Chicago, IL) both provide vital sign measurements such as blood pressure, electrocardiograms, heart rate, end tidal CO2, respiration rate, pulse oximetry and temperature along with ultrasound imaging. A video laryngoscopy capability is unique to the Tempus ProTM, while the LifeBot 10® supports connectivity with a digital stethoscope, otoscope, eye exam camera, and dermatoscope. Both devices include procedural guidance capabilities and have various data transmission and report generation features. TECHNOLOGY DEMONSTRATIONS NASA’s exploration-class missions will have severe resource constraints, long return trip durations, significant communication delays, and limited resupply opportunities. The medical systems of these missions will need to fit within an Earth-Independent Medical Operations (EIMO) construct. Key features of an EIMO medical system include: 1) technologies that support the prevention, diagnosis, and treatment of spaceflight medical events; 2) components that meet mass, volume, power and crew time/training constraints; 3) consideration of the medical skill level of the astronaut caregiver; 4) collection, storage and analysis of medical data within a central data architecture; and 5) incorporation of appropriate guidance and support tools that allow crew autonomy. Evaluations are underway to determine if it will be beneficial to include MIM devices within exploration medical systems by conducting a series of planned technical demonstrations. Exploration Atmosphere Chamber studies are being performed to determine MIM functionality in a high oxygen concentration atmosphere. A side-by-side comparison of the Tempus ProTM and LifeBot 10® will be performed during ground-based demonstrations. Use of the MIM devices within an EIMO medical scenario simulation will be practiced during ground-based demonstrations in preparation for International Space Station (ISS) demonstrations of the MIM device. These various demonstrations are designed to gather evidence for or against the inclusion of MIM devices within an EIMO medical system. EXPECTED DEMONSTRATION OUTCOMES Information will be gained about the feasibility, benefits, and challenges of using a multifunctional, all-in-one, medical device for medical diagnosis. Information will also be collected about performance differences as available ground support decreases. Gaining this understanding will allow for further development of exploration medical system capabilities, which take the EIMO construct into consideration.

B. E. Lewandowski↗

An Investigation in the Ames 40- by 80-Foot Wind Tunnel of a YT-56A Turboprop Engine Incorporating a Decoupler and a Controlled-Feathering Device

An investigation of a decoupler and a controlled-feathering device incorporated with the YT-56A turboprop engine has been made to determine the effectiveness of these devices in reducing the high negative thrust (drag) which accompanies power failure of this type of engine. Power failures were simulated by fuel cut-off, both without either device free to operate, and with each device free to operate singly. The investigation was made through an airspeed range from 50 to 230 mph. It was found that with neither device free to operate, the drag levels realized after power failures at airspeeds above 170 mph would impose vertical tail loads higher than those allowable for the YC-130, the airplane for which the test power package was designed. These levels were reached in approximately one second. The maximum drag realized after power failure was not appreciably altered by the use of the decoupler although the decoupler did put a limit on the duration of the peak drag. The controlled-feathering device maintained a level of essentially zero drag after power failure. The use of the decoupler in the YT-56A engine complicates windmilling air-starting procedures and makes it necessary to place operating restrictions on the engine to assure safe flight at low-power conditions,

Rogallo, Vernon L.↗

Operation of a deformable mirror device as a Fourier plane phase modulating filter

The operation of a deformable mirror device (DMD) as a Fourier plane phase modulating filter is described. An analysis of the optical characteristics of the DMD elements as phase modulators is summarized. Analytical and experimental results indicating the existence of a quasi-phase-only operational mode are presented. These results are used to specify the mirror deflection required to implement a binary phase-only image correlation operation. An optical correlator system is implemented using the DMD Fourier plane filter and experimental results from this system are compared with computer simulations of the correlator operation.

Florence, James M.↗