Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “developable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Temperature effect of elastic anisotropy and internal strain development in advanced nanostructured alloys: An in-situ synchrotron X-ray investigation

Nanostructured ferritic alloys (NFAs) are a promising structural material for advanced nuclear systems due to their exceptional radiation tolerance and high-temperature mechanical properties. Their remarkable properties result from the ultrafine ultrahigh density Y-Ti-O nanoclusters dispersed within the ferritic matrix. In this work, we performed in-situ synchrotron X-ray diffraction tests to study the tensile deformation process of the three types of NFAs: 9YWTV, 14YWT-sm13, and 14YWT-sm170 at both room temperature and elevated temperatures. A technique was developed, combining Kroner’s model and X-ray measurement, to determine the intrinsic monocrystal elastic-stiffness constants, and polycrystal Young’s modulus and Poisson’s ratio of the NFAs. Temperature dependence of elastic anisotropy was observed in the NFAs. An analysis of intergranular strain and strengthening factors determined that 14YWT-sm13 had a higher resistance to temperature softening compared to 9YWTV, attributed to the more effective nanoparticle strengthening during high-temperature mechanical loading.

Gan, Yingye↗

A General Strategy for Batch Development of High-Performance and Cost-Effective Sodium Layered Cathodes

High-performance and low-cost transition metal (TM) layered oxides using earth abundant elements are promising cathodes for Na-ion batteries. However, it is challenging to obtain desired materials because the large Na size, different Na occupations and various layer stacking sequences multiply the complication in determining the structure of a given composition and exacerbate uncertainty to the structure-property correlation. In this work, we use the attainment of desired NaxMnyNiZTM1-y-zO2-based cathode materials as an example to demonstrate a general roadmap for batch development of sodium layered cathodes towards practical applications. A synthesis phase diagram of NaxMnyNi1-yO2 was created for pre-screening and rational selection of the platform material of P2/O3-structured Na0.85Mn0.6Ni0.4O2. Cationic potential was leveraged in elemental substitution to further promote the material structural stability and electrochemical performance. Several cost-effective O3 and P2/O3 hybrid cathode materials have been obtained, all of which demonstrate excellent performance. In particular, the Na0.85Mn0.5Ni0.4Ti0.1O2 delivers a high specific capacity of ~130 mAh/g between 2-4 V and 91% retention after 500 cycles. The work discovers multiple materials as high-performance and cost-effective Na-ion battery cathodes and offers critical guidance to the rational design of future layered cathode materials.

Xiao, Biwei↗

Infrastructure development for radioactive materials at the NSLS-II

The X-ray Powder Diffraction (XPD) Beamline at the National Synchrotron Light Source-II is a multipurpose instrument designed for high-resolution, high-energy X-ray scattering techniques. In this article, the capabilities, opportunities and recent developments in the characterization of radioactive materials at XPD are described. The overarching goal of this work is to provide researchers access to advanced synchrotron techniques suited to the structural characterization of materials for advanced nuclear energy systems. XPD is a new beamline providing high photon flux for X-ray Diffraction, Pair Distribution Function analysis and Small Angle X-ray Scattering. The infrastructure and software described here extend the existing capabilities at XPD to accommodate radioactive materials. Such techniques will contribute crucial information to the characterization and quantification of advanced materials for nuclear energy applications. We describe the automated radioactive sample collection capabilities and recent X-ray Diffraction and Small Angle X-ray Scattering results from neutron irradiated reactor pressure vessel steels and oxide dispersion strengthened steels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of activity–descriptor relationships for supported metal ion hydrogenation catalysts on silica

With the increasing attention on single-site heterogeneous catalysts on account of their high specific activity, more effective catalyst design strategies are necessary. We demonstrate a first-principles-calculation-guided active-site design strategy for alkene hydrogenation using silica-supported single-atom single-site heterogeneous catalysts (SSHCs, i.e., M/SiO2). An activity-descriptor relationship for propylene hydrogenation was established using representative catalysts (i.e., Ga3+, Zn2+, Mn2+ and Ti4+/SiO2), correlating the computational activity descriptor (i.e., the reaction free energy of the metal hydride formation) with the experimental reaction rates. Microkinetic modeling confirmed the predicted reaction mechanisms and further explained the rationale of the activity-descriptor relationship. This relationship was then used to predict the trend of activities of a variety of isolated ions on silica, and an In3+/SiO2 catalyst was identified as the most promising candidate based on its predicted activity and synthetic feasibility. The monodispersed In3+/SiO2 catalyst was then synthesized, for the first time, and showed higher propylene hydrogenation activity than the other four single-atom SSHCs, as predicted. Detailed spectroscopic characterization (XAS, XPS, DRIFTS and DRUV-Vis) provided insights into coordination environments and oxidation states of the catalysts, as well as evidence for the hydride intermediate. The successful discovery of the In3+/SiO2 catalyst for propylene hydrogenation using the first-principles-calculations-guided design strategy opens up new opportunities for efficient development of single-atom SSHCs.

DFT↗

Development of a physiologically based pharmacokinetic model for assessment of human exposure to bisphenol A

A previously developed physiologically based pharmacokinetic (PBPK) model for bisphenol A (BPA) in adult rhesus monkeys was modified to characterize the pharmacokinetics of BPA and its phase II conjugates in adult humans following oral ingestion. Coupled with in vitro studies on BPA metabolism in the liver and the small intestine, the PBPK model was parameterized using oral pharmacokinetic data with deuterated-BPA (d{sub 6}-BPA) delivered in cookies to adult humans after overnight fasting. The availability of the serum concentration time course of unconjugated d{sub 6}-BPA offered direct empirical evidence for the calibration of BPA model parameters. The recalibrated PBPK adult human model for BPA was then evaluated against published human pharmacokinetic studies with BPA. A hypothesis of decreased oral uptake was needed to account for the reduced peak levels observed in adult humans, where d{sub 6}-BPA was delivered in soup and food was provided prior to BPA ingestion, suggesting the potential impact of dosing vehicles and/or fasting on BPA disposition. With the incorporation of Monte Carlo analysis, the recalibrated adult human model was used to address the inter-individual variability in the internal dose metrics of BPA for the U.S. general population. Model-predicted peak BPA serum levels were in the range of pM, with 95% of human variability falling within an order of magnitude. This recalibrated PBPK model for BPA in adult humans provides a scientific basis for assessing human exposure to BPA that can serve to minimize uncertainties incurred during extrapolations across doses and species. - Highlights: • A PBPK model predicts the kinetics of bisphenol A (BPA) in adult humans. • Serum concentrations of aglycone BPA are available for model calibration. • Model predicted peak BPA serum levels for adult humans were in the range of pM. • Model predicted 95% of human variability fell within an order of magnitude.

60 APPLIED LIFE SCIENCES↗

Development of a PBPK model of thiocyanate in rats with an extrapolation to humans: A computational study to quantify the mechanism of action of thiocyanate kinetics in thyroid

Thyroid homeostasis can be disturbed due to thiocyanate exposure from the diet or tobacco smoke. Thiocyanate inhibits both thyroidal uptake of iodide, via the sodium-iodide symporter (NIS), and thyroid hormone (TH) synthesis in the thyroid, via thyroid peroxidase (TPO), but the mode of action of thiocyanate is poorly quantified in the literature. The characterization of the link between intra-thyroidal thiocyanate concentrations and dose of exposure is crucial for assessing the risk of thyroid perturbations due to thiocyanate exposure. We developed a PBPK model for thiocyanate that describes its kinetics in the whole-body up to daily doses of 0.15 mmol/kg, with a mechanistic description of the thyroidal kinetics including NIS, passive diffusion, and TPO. The model was calibrated in a Bayesian framework using published studies in rats. Goodness-of-fit was satisfactory, especially for intra-thyroidal thiocyanate concentrations. Thiocyanate kinetic processes were quantified in vivo, including the metabolic clearance by TPO. The passive diffusion rate was found to be greater than NIS-mediated uptake rate. The model captured the dose-dependent kinetics of thiocyanate after acute and chronic exposures. Model behavior was evaluated using a Morris screening test. The distribution of thiocyanate into the thyroid was found to be determined primarily by the partition coefficient, followed by NIS and passive diffusion; the impact of the latter two mechanisms appears to increase at very low doses. Extrapolation to humans resulted in good predictions of thiocyanate kinetics during chronic exposure. The developed PBPK model can be used in risk assessment to quantify dose-response effects of thiocyanate on TH. - Highlights: • A PBPK model of thiocyanate (SCN{sup −}) was calibrated in rats in a Bayesian framework. • The intra-thyroidal kinetics of thiocyanate including NIS and TPO was modeled. • Passive diffusion rate for SCN{sup −} seemed to be greater than the NIS-mediated uptake. • The dose-dependent kinetics of SCN{sup −} was captured after an acute and chronic exposure. • The PBPK model of thiocyanate was successfully extrapolated to humans.

54 ENVIRONMENTAL SCIENCES↗

Development and Scale-up of Continuous Electrocatalytic Hydrogenation of Functionalized Nitro arenes, Nitriles and Unsaturated Aldehydes

Electrolysis reactors based on the filter-press architecture of redox flow batteries have proven to be effective and scalable towards the production of commercially relevant, pharmaceutical quantities of anilines (>500 kg/year) from halogen-, hydroxyl-, and carbonyl-substituted nitroarenes. Turbulent flow through the carbon felts on which the catalysts were supported facilitated scaling towards production levels because it conferred on the reactors scale-independent, plug flow-like residence time distributions and high mass transfer coefficients. Equipping the cells with micro-reference electrodes made it possible to transfer reaction conditions first developed in batch systems to the continuous flow reactors. The catalysts prepared by incipient wetness impregnation of metal salts into lightly oxidized carbon felt supports were readily generalizable.

Egbert, Jonathan D.↗

U.S. Manufacturing Water Use Data and Estimates: Current State, Limitations, and Future Needs for Supporting Manufacturing Research and Development

Water is essential to manufacturing operations; without it, many facilities could not operate or meet production demands. Physical, reputational, and regulatory risks to water supplies compounded by climate change-induced impacts on hydrological conditions threaten the adequacy of water supplies for manufacturing. Manufacturing water use has not been a major focus of either water or manufacturing-related research. Research and development (R&D) aimed at helping manufacturers use water more sustainably and adapt to changing water conditions is needed to ensure a thriving sector and economy. However, the ability to identify R&D needs is severely limited due to a lack of current, statistically representative data on manufacturing water use and its environmental implications. In this Perspective, we outline four key questions to inform R&D on manufacturing use and highlight how the current state of water data in the United States does not support the adequate investigation of these questions. We make recommendations for the water data characteristics needed to explore the research questions and knowledgeably inform R&D on manufacturing water use.

McCall, James↗

Perspectives on the Development of Oxide-Based Photocathodes for Solar Fuel Production

Photoelectrochemical cells (PECs), which use semiconductor electrodes (photoelectrodes) to absorb solar energy and perform chemical reactions, constitute one of the most attractive strategies to produce chemical fuels using renewable energy sources. Oxide-based photoelectrodes specifically have been intensively investigated for the construction of PECs due to their relatively inexpensive processing costs and better stability in aqueous media compared with other types of photoelectrodes. Although there have been many advancements in the development of oxide-based photoanodes, our understanding of oxide-based photocathodes remains limited. The goal of this Perspective is to examine the recent progress made in the field of oxide-based photocathodes and discuss future research directions. The photocathode systems considered here include binary and ternary Cu-based photocathodes and ternary Fe-based photocathodes. Here, we assessed the characteristics and major advantages and drawbacks of each system and identified the most critical research gaps. The insights and discussions provided in this Perspective will serve as useful resources for the design of future studies, leading to the development of more efficient and practical PECs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Use of steric encumbrance to develop conjugated nanoporous polymers for metal-free catalytic hydrogenation

The design and synthesis of metal-free heterogeneous catalysts for efficient hydrogenation remains a great challenge. Here we report a novel approach to create conjugated nanoporous polymers with efficient hydrogenation activities toward unsaturated ketones by leveraging the innate steric encumbrance. The steric bulk of the framework as well as the local sterics of the Lewis basic sites within the polymeric skeleton result in the generation of the putative catalyst. Lastly, this approach opens up new possibilities for the development of innovative metal-free heterogeneous catalysts.

36 MATERIALS SCIENCE↗

Development of a reaction cell for in-situ/operando studies of surface of a catalyst under a reaction condition and during catalysis

Tracking surface chemistry of a catalyst during catalysis is significant for fundamental understanding of catalytic performance of the catalyst since it allows for establishing an intrinsic correlation between surface chemistry of a catalyst at its working status and its corresponding catalytic performance. Ambient pressure X-ray photoelectron spectroscopy can be used for in-situ studies of surfaces of different materials or devices in a gas. To simulate the gaseous environment of a catalyst in a fixed-bed a flowing gaseous environment of reactants around the catalyst is necessary. Here, we report the development of a new flowing reaction cell for simulating in-situ study of a catalyst surface under a reaction condition in gas of one reactant or during catalysis in a mixture of reactants of a catalytic reaction. The homemade reaction cell is installed in a high vacuum (HV) or ultrahigh vacuum (UHV) environment of a chamber. The flowing gas in the reaction cell is separated from the HV or UHV environment through well sealings at three interfaces between the reaction cell and X-ray window, sample door and aperture of front cone of an energy analyzer. Catalyst in the cell is heated through infrared laser beam introduced through a fiber optics interfaced with the reaction cell through a homemade feedthrough. The highly localized heating on the sample holder and Au-passivated internal surface of the reaction cell effectively minimizes any unwanted reactions potentially catalyzed by the reaction cell. The incorporated laser heating allows a fast heating and a high thermal stability of the sample at a high temperature. With this cell, a catalyst at 800 °C in a flowing gas can be tracked readily.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and implementation of a portable grating interferometer system as a standard tool for testing optics at the Advanced Photon Source beamline 1-BM

We developed a portable X-ray grating interferometer setup as a standard tool for testing optics at the Advanced Photon Source (APS) beamline 1-BM. The interferometer can be operated in phase-stepping, Moiré, or single-grating harmonic imaging mode with 1-D or 2-D gratings. All of the interferometer motions are motorized; hence, it is much easier and quicker to switch between the different modes of operation. A novel aspect of this new instrument is its designed portability. While the setup is designed to be primarily used as a standard tool for testing optics at 1-BM, it could be potentially deployed at other APS beamlines for beam coherence and wavefront characterization or imaging. Herein, the design of the interferometer system is described in detail and coherence measurements obtained at the APS 34-ID-E beamline are presented. The coherence was probed in two directions using a 2-D checkerboard, a linear, and a circular grating at X-ray energies of 8 keV, 11 keV, and 18 keV.

47 OTHER INSTRUMENTATION↗

Progress on the development of the next generation x-ray beam position monitors at the advanced photon source

Accurate and stable x-ray beam position monitors (XBPMs) are key elements in obtaining the desired user beam stability in the Advanced Photon Source (APS). The next generation XBPMs for high heat load front ends (HHL FEs) have been designed to meet these requirements by utilizing Cu K-edge x-ray fluorescence (XRF) from a pair of copper absorbers and have been installed at the front ends (FEs) of the APS. Commissioning data showed a significant performance improvement over the existing photoemission-based XBPMs. While a similar design concept can be applied for the canted undulator front ends, where two undulator beams are separated by 1.0-mrad, the lower beam power (< 10 kW) per undulator allows us to explore lower-cost solutions based on Compton scattering from the diamond blades placed edge-on to the x-ray beam. A prototype of the Compton scattering XBPM system was installed at 24-ID-A in May 2015. In this report, the design and test results for XRF-based XBPM and Compton scattering based XBPM are presented. Ongoing research related to the development of the next generation XBPMs on thermal contact resistance of a joint between two solid bodies is also discussed.

43 PARTICLE ACCELERATORS↗

Developments in time-resolved x-ray research at APS beamline 7ID

The 7ID beamline of the Advanced Photon Source (APS) is dedicated to time-resolved research using x-ray imaging, scattering, and spectroscopy techniques. Time resolution is achieved via gated detectors and/or mechanical choppers in conjunction with the time structure of the x-ray beam. Three experimental hutches allow for a wide variety of experimental setups. Major areas of research include atomic, molecular, and optical physics; chemistry; condensed matter physics in the bulk, thin film, and surface regimes; and fluid-spray dynamics. Recent developments in facilities at 7ID include a high-power, high-repetition-rate picosecond laser to complement the 1 kHz ultrafast laser. For the ultrafast laser, a newly commissioned optical parametric amplifier provides pump wavelength from 0.2 to 15 µm with energy per pulse up to 200 µJ. A nanodiffraction station has also been commissioned, using Fresnel zone-plate optics to achieve a focused x-ray spot of 300 nm. This nanoprobe is not only used to spatially resolve the evolution of small features in samples after optical excitation, but also has been combined with an intense THz source to study material response under ultrafast electric fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a beam ion velocity detector for the heavy ion beam probe

In an axisymmetric plasma, the conservation of canonical angular momentum constrains heavy ion beam probe (HIBP) trajectories such that measurement of the toroidal velocity component of secondary ions provides a localized determination of the poloidal flux at the volume where they originated. We have developed a prototype detector which is designed to determine the beam angle in one dimension through the detection of ion current landing on two parallel planes of detecting elements. A set of apertures creates a pattern of ion current on wires in the first plane and solid metal plates behind them; the relative amounts detected by the wires and plates determine the angle which beam ions enter the detector, which is used to infer the toroidal velocity component. The design evolved from a series of simulations within which we modeled ion beam velocity changes due to equilibrium and fluctuating magnetic fields, along with the ion beam profile and velocity dispersion, and studied how these and characteristics such as the size, cross section, and spacing of the detector elements affect performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗