Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Performance Verification of the Gravity and Extreme Magnetism Small Explorer GEMS X-Ray Polarimeter

olarimetry is a powerful tool for astrophysical observations that has yet to be exploited in the X-ray band. For satellite-borne and sounding rocket experiments, we have developed a photoelectric gas polarimeter to measure X-ray polarization in the 2-10 keV range utilizing a time projection chamber (TPC) and advanced micro-pattern gas electron multiplier (GEM) techniques. We carried out performance verification of a flight equivalent unit (1/4 model) which was planned to be launched on the NASA Gravity and Extreme Magnetism Small Explorer (GEMS) satellite. The test was performed at Brookhaven National Laboratory, National Synchrotron Light Source (NSLS) facility in April 2013. The polarimeter was irradiated with linearly-polarized monochromatic X-rays between 2.3 and 10.0 keV and scanned with a collimated beam at 5 different detector positions. After a systematic investigation of the detector response, a modulation factor greater than or equal to 35% above 4 keV was obtained with the expected polarization angle. At energies below 4 keV where the photoelectron track becomes short, diffusion in the region between the GEM and readout strips leaves an asymmetric photoelectron image. A correction method retrieves an expected modulation angle, and the expected modulation factor, approximately 20% at 2.7 keV. Folding the measured values of modulation through an instrument model gives sensitivity, parameterized by minimum detectable polarization (MDP), nearly identical to that assumed at the preliminary design review (PDR).

Time Projection↗

Lunar Phase Function at 1064 Nm from Lunar Orbiter Laser Altimeter Passive and Active Radiometry

We present initial calibration and results of passive radiometry collected by the Lunar Orbiter Laser Al- timeter onboard the Lunar Reconnaissance Orbiter over the course of 12 months. After correcting for time- and temperature-dependent dark noise and detector responsivity variations, the LOLA passive radiometry measurements are brought onto the absolute radiance scale of the SELENE Spectral Profiler. The resulting photometric precision is estimated to be approximately 5%. We leverage the unique ability of LOLA to measure normal albedo to explore the 1064 nm phase function's dependence on various geologic parameters. On a global scale, we find that iron abundance and optical maturity (quantified by FeO and OMAT) are the dominant controlling parameters. Titanium abundance (TiO2 ), surface roughness on decimeter to decameter scales, and soil thermophysical properties have a smaller effect, but the latter two are correlated with OMAT, indicating that exposure age is the driving force behind their effects in a globally-averaged sense. The phase function also exhibits a dependence on surface slope at approximately 300 m baselines, possibly the result of mass wasting exposing immature material and/or less space weathering due to reduced sky visibility. Modeling the photometric function in the Hapke framework, we find that, relative to the highlands, the maria exhibit decreased backscattering, a smaller opposition effect (OE) width, and a smaller OE amplitude. Immature highlands regolith has a higher backscattering fraction and a larger OE width compared to mature highlands regolith. Within the maria, the backscattering fraction and OE width show little dependence on TiO2 and OMAT. Variations in the phase function shape at large phase angles are observed in and around the Copernican-aged Jackson crater, including its dark halo, a putative impact melt deposit. Finally, the phase function of the Reiner Gamma Formation behaves more optically immature than is typical for its composition and OMAT, suggesting the visible-to-near-infrared spectrum and phase function respond differently to the unusual regolith evolution and properties at this location.

LOLA↗

ANTARES Constrains a Blazar Origin of Two IceCube PeV Neutrino Events

Context. The source(s) of the neutrino excess reported by the IceCube Collaboration is unknown. The TANAMI Collaboration recently reported on the multiwavelength emission of six bright, variable blazars which are positionally coincident with two of the most energetic IceCube events. Objects like these are prime candidates to be the source of the highest-energy cosmic rays, and thus of associated neutrino emission. Aims. We present an analysis of neutrino emission from the six blazars using observations with the ANTARES neutrino telescope. Methods. The standard methods of the ANTARES candidate list search are applied to six years of data to search for an excess of muons - and hence their neutrino progenitors - from the directions of the six blazars described by the TANAMI Collaboration, and which are possibly associated with two IceCube events. Monte Carlo simulations of the detector response to both signal and background particle fluxes are used to estimate the sensitivity of this analysis for di erent possible source neutrino spectra. A maximum-likelihood approach, using the reconstructed energies and arrival directions of through-going muons, is used to identify events with properties consistent with a blazar origin. Results. Both blazars predicted to be the most neutrino-bright in the TANAMI sample (1653-329 and 1714-336) have a signal flux fitted by the likelihood analysis corresponding to approximately one event. This observation is consistent with the blazar-origin hypothesis of the IceCube event IC 14 for a broad range of blazar spectra, although an atmospheric origin cannot be excluded. No ANTARES events are observed from any of the other four blazars, including the three associated with IceCube event IC20. This excludes at a 90% confidence level the possibility that this event was produced by these blazars unless the neutrino spectrum is flatter than -2.4.

general↗

Fermi GBM Observations of LIGO Gravitational-Wave Event Gw150914

With an instantaneous view of 70% of the sky, the Fermi Gamma-ray Burst Monitor (GBM) is an excellent partner in the search for electromagnetic counterparts to gravitational-wave (GW) events. GBM observations at the time of the Laser Interferometer Gravitational-wave Observatory (LIGO) event GW150914 reveal the presence of a weak transient above 50 keV, 0.4 s after the GW event, with a false-alarm probability of 0.0022 (2.9(sigma)). This weak transient lasting 1 s was not detected by any other instrument and does not appear to be connected with other previously known astrophysical, solar, terrestrial, or magnetospheric activity. Its localization is ill-constrained but consistent with the direction of GW150914. The duration and spectrum of the transient event are consistent with a weak short gamma-ray burst (GRB) arriving at a large angle to the direction in which Fermi was pointing where the GBM detector response is not optimal. If the GBM transient is associated with GW150914, then this electromagnetic signal from a stellar mass black hole binary merger is unexpected. We calculate a luminosity in hard X-ray emission between 1 keV and 10 MeV of 1.8(sup +1.5, sub -1.0) x 10(exp 49) erg/s. Future joint observations of GW events by LIGO/Virgo and Fermi GBM could reveal whether the weak transient reported here is a plausible counterpart to GW150914 or a chance coincidence, and will further probe the connection between compact binary mergers and short GRBs.

gamma-ray burst: general – gravitational waves↗

Performance Assessments and Comparisons of S-NPP and NOAA-20 (JPSS-1) VIIRS On-Orbit Calibration

The first Visible Infrared Imaging Radiometer Suite (VIIRS) instrument has been in operation for more than 6 years on-board the S-NPP satellite and the second instrument, with the same design and performance requirements, was launched in November, 2017 on-board the JPSS-1 satellite (named NOAA-20 after reaching its orbit) and is currently in normal operation conditions. This paper provides a brief description of VIIRS on-orbit calibration and characterization activities and presents performance assessments and comparisons of S-NPP and NOAA-20 VIIRS using data collected from their on-board calibrators (OBC) and regularly scheduled lunar observations. Results show that NOAA-20 VIIRS is performing as well or better than S-NPP VIIRS in all of the key performance metrics. The NOAA-20 reflective solar bands, including the day-night band, have experienced less than 1% change in gain in the first 250 days since launch and did not suffer from the contamination related rapid degradation experienced by S-NPP VIIRS. Some of the NOAA20 thermal emissive bands had larger than expected gain degradation after launch due to ice buildup on the dewar window of the long-wave IR focal plane assembly but a mid-mission outgassing operation was able to restore their gains and maintain stable behavior. Though this study is focused on the sensor's key performance parameters, such as detector responses (gains), signal-to-noise ratios, and noise-equivalent temperature differences, challenges identified and lessons learned through different phases of on-orbit calibration and characterization are also discussed.

DNB↗

Comparison of the MODIS and VIIRS On-Board SD and SDSM Performance

The MODIS reflective solar bands (RSB) are calibrated on-orbit using a solar diffuser (SD) with its on-orbit degradation, or change in the bi-directional reflectance factor (BRF) monitored using a solar diffuser stability monitor (SDSM). By performing alternate observations of direct sunlight via an attenuation screen and of sunlight reflected diffusely off the SD, the SDSM monitors the on-orbit degradation of the SD. The MODIS SDSM has 9 detectors, covering wavelengths from 0.41 to 0.94 microns. Both Terra and Aqua MODIS instruments have successfully operated for more than 16 years on-orbit, with the SD experiencing significant degradation at the shortest wavelength (about 50 percent for Terra MODIS and about 20 percent for Aqua MODIS at 0.41 microns). The first VIIRS instrument on the Suomi NPP spacecraft was launched in October 2011 and the follow-on instrument was launched in November 2017 on the JPSS-1 spacecraft (now NOAA-20). Both the VIIRS instruments carry a MODIS-like SD and SDSM system with an improved design based on the lessons learned from MODIS. Unlike MODIS, the VIIRS SDSM collects data using 8 detectors covering a similar wavelength range as MODIS. A similar wavelength dependent SD degradation pattern is also observed in both VIIRS instruments. This paper provides a comparison of the on-orbit performance of the four instruments in terms of the on-orbit changes in the SDSM detector responses and on-orbit degradations of their SDs. The NOAA-20 VIIRS instrument is still in its first year of operation and hence the early performance of the Terra and Aqua MODIS and SNPP VIIRS is discussed to provide a perspective comparison.

VIIRS↗

Initial Calibration Activities and Performance Assessments of NOAA-20 VIIRS

The second VIIRS instrument was launched on-board the NOAA-20 (formerly JPSS-1) satellite onNovember 18, 2017. It was designed and built with the same performance requirements as the first VIIRSon-board the S-NPP launched on October 28, 2011. Currently, the NOAA-20 is orbiting the Earth in thesame plane as the S-NPP but separated in time and space by 50 minutes. The VIIRS observations are made in22 spectral bands, including a day-night band (DNB) that cover wavelengths from visible to long-waveinfrared. The sensor's on-orbit calibration is provided by a set of on-board calibrators (OBCs), which includea solar diffuser (SD), a solar diffuser stability monitor (SDSM), and a blackbody (BB). After turn-on, theVIIRS instrument conducted a series of post-launch testing (PLT) and intensive calibration and validation(ICV) activities, including those performed via spacecraft maneuvers, designed to verify and establishinstrument on-orbit calibration performance baseline. This paper provides an overview of NOAA-20 VIIRSICV activities and an assessment of its initial on-orbit performance with a focus on several key calibrationparameters, such as the detector response (or gain), dynamic range, and signal-to-noise ratio (SNR). Variousissues identified and lessons learned from initial instrument operation and calibration are also discussed insupport of long-term monitoring (LTM) of NOAA-20 VIIRS calibration and data quality.

Calibration↗

Large-Scale Magnetic Microcalorimeter: Modeling and Multiplexing

We will present performance predictions for a large-scale magnetic microcalorimeter detector array intended for a potential future X-ray astrophysics mission. The focal plane comprises three distinct array designs, necessitating over 100,000 pixels to meet the scientific objectives. Our presentation will describe the results of numerical modeling aimed at estimating the energy resolution and detector responses for each array. Additionally, we will discuss the application of microwave multiplexing technology for the comprehensive readout of the entire sensor array.

x-ray↗

Radiation response issues for infrared detectors

Researchers describe the most important radiation response issues for infrared detectors. In general, the two key degradation mechanisms in infrared detectors are the noise produced by exposure to a flux of ionizing particles (e.g.; trapped electronics and protons, debris gammas and electrons, radioactive decay of neutron-activated materials) and permanent damage produced by exposure to total dose. Total-dose-induced damage is most often the result of charge trapping in insulators or at interfaces. Exposure to short pulses of ionization (e.g.; prompt x rays or gammas, delayed gammas) will cause detector upset. However, this upset is not important to a sensor unless the recovery time is too long. A few detector technologies are vulnerable to neutron-induced displacement damage, but fortunately most are not. Researchers compare the responses of the new technologies with those of the mainstream technologies of PV HgCdTe and IBC Si:As. One important reason for this comparison is to note where some of the newer technologies have the potential to provide significantly improved radiation hardness compared with that of the mainstream technologies, and thus to provide greater motivation for the pursuit of these technologies.

Kalma, Arne H.↗

Incident angle dependence of proton response of CR-39 (TS-16) track detector

The proton response of the TS-16 type of CR-39 plastic nuclear track detector has been studied with accelerated and fast neutron induced protons in vacuum and in air. The diameters of etched tracks were measured as a function of etching time and the etch rate ratio and the etch induction layer were determined from the growth curve of the diameter using a variable etch rate ratio model. In the case of the accelerated protons in vacuum an anomalous incident angle dependence of the response is observed.

Radiation Monitoring/instrumentation↗

Electron calibration on a high-energy cosmic ray detector.

The response of the GSFC High Energy Cosmic Ray Detector has been studied using electrons in the energy range from 5.4 to 18 GeV. A semiempirical analytic form has been developed to determine the starting points and the energies of electron-induced cascade showers. The energy resolution thus obtained has a full width at half maximum of 17%, and the starting point can be determined to within 0.1 to 0.2 radiation length. The results of this response calibration provide a basis on which cosmic ray electrons can be reliably identified and analyzed in the presence of a large proton background.

Crannell, C. J.↗

The response of smoke detectors to pyrolysis and combustion products from aircraft interior materials

The following projects were completed as part of the effort to develop and test economically feasible fire-resistant materials for interior furnishings of aircraft as well as detectors of incipient fires in passenger and cargo compartments: (1) determination of the sensitivity of various contemporary gas and smoke detectors to pyrolysis and combustion products from materials commonly used in aircraft interiors and from materials that may be used in the future, (2) assessment of the environmental limitations to detector sensitivity and reliability. The tests were conducted on three groups of materials by exposure to the following three sources of exposure: radiant and Meeker burner flame, heated coil, and radiant source only. The first test series used radiant heat and flame exposures on easily obtainable test materials. Next, four materials were selected from the first group and exposed to an incandescent coil to provide the conditions for smoldering combustion. Finally, radiant heat exposures were used on advanced materials that are not readily available.

Mckee, R. G.↗

Preliminary Analysis of the Multisphere Neutron Spectrometer

Crews working on present-day jet aircraft are a large occupationally exposed group with a relatively high average effective dose from galactic cosmic radiation. Crews of future high-speed commercial aircraft flying at higher altitudes would be even more exposed. To help reduce the significant uncertainties in calculations of such exposures, the Atmospheric Ionizing Radiation (AIR) Project, an international collaboration of 15 laboratories, made simultaneous radiation measurements with 14 instruments on five flights of a NASA ER-2 high-altitude aircraft. The primary AIR instrument was a highly sensitive extended-energy multisphere neutron spectrometer with lead and steel shells placed within the moderators of two of its 14 detectors to enhance response at high energies. Detector responses were calculated for neutrons and charged hadrons at energies up to 100 GeV using MCNPX. Neutron spectra were unfolded from the measured count rates using the new MAXED code. We have measured the cosmic-ray neutron spectrum (thermal to greater than 10 GeV), total neutron fluence rate, and neutron effective dose and dose equivalent rates and their dependence on altitude and geomagnetic cutoff. The measured cosmic-ray neutron spectra have almost no thermal neutrons, a large "evaporation" peak near 1 MeV and a second broad peak near 100 MeV which contributes about 69% of the neutron effective dose. At high altitude, geomagnetic latitude has very little effect on the shape of the spectrum, but it is the dominant variable affecting neutron fluence rate, which was 8 times higher at the northernmost measurement location than it was at the southernmost. The shape of the spectrum varied only slightly with altitude from 21 km down to 12 km (56 - 201 grams per square centimeter atmospheric depth), but was significantly different on the ground. In all cases, ambient dose equivalent was greater than effective dose for cosmic-ray neutrons.

Goldhagen, P.↗

Sensitive gas chromatographic detection of acetaldehyde and acetone using a reduction gas detector

The response of a newly available mercuric oxide Reduction Gas Detector (RGD-2) to subpicomole and larger quantities of acetaldehyde and acetone is tested. The RGD-2 is found to be capable of subpicomole detection for these carbonyls and is more sensitive than an FID (Flame Ionization Detector) by an order of magnitude. Operating parameters can be further optimized to make the RGD-2 some 20-40 times more sensitive than an FID. The detector is linear over a wide range and is easily adapted to a conventional gas chromatograph (GC). Such a GC-RGD-2 system should be suitable for atmospheric carbonyl measurements in clean as well as polluted environments.

O'Hara, Dean↗

GaAs/AlGaAs superlattice miniband detector with 14.5 microns peak response

Extended long wavelength infrared detection with a miniband-type AlGaAs/GaAs superlattice structure is reported. The experimental response band of the detector is peaked near 14.5 microns in good agreement with the theoretical response, provided that electron-elecltron interactions are taken into account. The detector operates at a low bias voltage, which could lead to important advantages in application to IR focal plane arrays.

Bandara, K. M. S. V.↗