Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “design and dispatch”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Rethinking the Price Formation Problem–Part 1: Participant Incentives under Uncertainty

Operators of organized wholesale electricity markets attempt to form prices in such a way that the private incentives of market participants are consistent with a socially optimal commitment and dispatch schedule. In the U.S. context, several competing price formation schemes have been proposed to address the non-convex production cost functions characteristic of most generation technologies. Here, this paper considers how the design and analysis of price formation policies for non-convex markets are affected by the uncertainty inherent in electricity demand and supply. We argue that by excluding uncertainty, the analytical framework underlying existing policies mischaracterizes the incentives of market participants, leading to inefficient price formation and poor incentives for flexibility. We establish favorable theoretical properties of a new construct, ex ante convex hull pricing , and demonstrate the difference between this idealized benchmark and existing methods on a large-scale test system. Given increased operational uncertainty with a transition to wind and solar generation, distortions caused by poor incentives for flexibility are likely to grow without improved price formation in organized wholesale markets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

System Modeling of the HTTR and Economic Dispatch Model of the Secondary System

High Temperature Gas-cooled Reactors (HTGRs) can be used for the generation of electricity and their process heat can be used to improve the efficiency of chemical processes such as hydrogen production. The JAEA-operated High-Temperature engineering Test Reactor (HTTR-GT/H2) is exploring using the reactor for electricity and hydrogen production. A RELAP5-3D model of the HTTR-GT/H2 secondary system has been developed using design information. The various components and heat exchangers in the secondary system were modeled and results were compared to the design conditions. The results for the sole-power generation mode were shown to fit the design conditions very well. The largest temperature difference was on the order of 7 K, and the largest pressure difference was on the order of 0.05 MPa. The results for the hydrogen cogeneration mode did not match the design conditions nearly as well. The largest temperature difference was about 39 K and the largest pressure difference was about 0.27 MPa at the compressor outlet. The larger differences for the hydrogen cogeneration mode are attributed to the various complex components and the flow being split in the secondary loop. A transient reduction in heat removal capability of the secondary system was investigated. Reactor temperatures are anticipated to rise as a result. The core reactivity response due to this increase in temperature is investigated and is expected to add negative reactivity to the reactor. An economic dispatch model was developed for a nuclear-driven iodine-sulfur cycle system to determine hydrogen sale prices that would make such a system profitable. The study focuses on the development of the economic model and the role that input data plays on final calculated values. It was found that the input electricity prices, whether using historical data or a host of synthetic time histories, produce significantly different breakeven hydrogen sale prices. As such, great care should be used in these economic dispatch analyses to select reasonable input assumptions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

California Price Response Potential Study

California's energy landscape is undergoing a significant transformation, driven by the increasing integration of renewable energy sources, the increased adoption of distributed energy resources, the electrification of end-use loads, and the growing need for grid efficiency. To address these challenges, recent revisions to the State’s Load Management Standards (LMS) require all of California’s large utilities and community choice aggregators (CCAs) to offer dynamic electricity pricing options to customers by 2027. Dynamic pricing, which involves varying electricity rates based on real-time supply and demand conditions, offers a promising solution for optimizing grid operations, reducing costs, and incentivizing efficient use of grid capacity. Effective implementation of dynamic pricing requires understanding the potential impacts on customer bills, system load, and the cost-effectiveness of automation technologies. This study aims to evaluate the load response of various end-use devices to hourly dynamic prices. The end-uses studied here are space cooling, space heating, water heating, crop irrigation, pool and spa pumps, and electric vehicle (EV) charging, all for both residential and commercial applications, except for crop irrigation. In 2030, these end uses are forecasted to account for 18% of annual electricity demand in the state, but 40% of demand in the peak net load hour. By modeling possible price-responsive load dispatch algorithms and assessing the resulting impacts on both individual bills and the overall grid, we seek to inform policymakers and utilities about the potential benefits and challenges associated with dynamic pricing, and considerations for the design of dynamic pricing tariffs. Additionally, we will explore the cost effectiveness of adopting automation technologies to enable devices to respond more effectively to real-time price signals. This study considers a range of price profiles, accounting for differences across utilities and customer classes, and presents scenarios for dynamic price design via variation in the percentage of total customer electric costs that are allocated dynamically (versus constituting a fixed portion of the hourly volumetric price). We present results focused primarily on 2030, forecasting electricity prices under both low and high-cost scenarios, to inform longer-term tariff design considerations. We design tariffs by starting with 2019 prices that were calculated according to CalFUSE guidance (CPUC, 2022) and that have been used in recent studies; these prices are all-in volumetric rates that vary by utility and are revenue-neutral to each customer class. They are developed by considering six electricity cost components that are allocated hourly based on system load indicators (gross and net load, and wholesale prices). These prices are forecasted to 2030 for low and high cost scenarios, considering recent trends in total electricity costs with and without years of substantial wildfire mitigation investments. These tariffs, which allocate all costs on an hourly basis, are considered our “Full” dynamic tariff design scenario, while two additional scenarios explore allocating a portion of costs as a flat volumetric charge: the “Medium” scenario allocates 50% of revenue dynamically (and keeps 50% flat), while the “Mild” scenario allocates 20% of revenue dynamically. The 20% dynamic allocation on the Mild scenario aims to represent a case where only the marginal operating costs of the grid are included in the dynamic price.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Modeling and Optimization of a Nuclear Integrated Energy System for the Remote Microgrid on El Hierro

Nuclear microreactors are a potential technology to provide heat and electricity for remote microgrids. There is potential for the microgrid on the island of El Hierro to use a microreactor, within an integrated energy system (IES), to generate electricity and provide desalinated water. This work proposes a workflow for optimizing and analyzing IESs for microgrids. In this study, an IES incorporating a microreactor, thermal energy storage (TES) system, combined heat and power plant, and a thermal desalination plant was designed, optimized, and analyzed using Idaho National Laboratory’s Framework for Optimization of Resources and Economics (FORCE) toolset. The optimization tool, Holistic Energy Resource Optimization Network (HERON), was used to determine the optimal capacity sizes and dispatch for the reactor and thermal energy storage systems to meet demand. The optimized reactor and TES sizes were found to be 11.61 MWth and 58.47 MWhth, respectively, when optimizing the IES to replace 95% of the island’s existing diesel generation needs. A dynamic model of the system was created in the Modelica language, using models from the HYBRID repository, to analyze and verify the dispatch from the optimizer. The dynamic model was able to meet the ramp rates while maintaining reactor power with minimal control adjustments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design analysis of a particle-based thermal energy storage system for concentrating solar power or grid energy storage

Energy storage is becoming indispensable for expanding renewable energy integration, and it is critical to the future low-carbon energy supply. Large-capacity, grid scale energy storage can support the integration of solar and wind power and support grid resilience with the diminishing capacity of baseload fossil power plants. With the development of thermal energy storage (TES) for concentrating solar power systems, standalone TES for grid integration becomes attractive due to the declining renewable generation cost and an increasing need for energy storage. The standalone TES system introduced in this paper can play a big role in the carbon-free energy future with capacity larger than batteries and cost likely lower than other energy storage methods such as pumped storage hydropower and compressed air energy storage, both of which also have geological limitations. To this end, we describe a TES system that uses stable, inexpensive solid particles as a TES media to provide scalable, low cost energy storage. The particle-based TES has the ability to drive various thermal power cycles including conventional steam-Rankine, air Brayton turbine with combined-cycle ability, or the emerging supercritical carbon dioxide Brayton power cycle. This work describes the containment design method including a concrete silo and an internal-insulation layer for the particle-TES system. The economic analysis shows significantly low storage cost when the particle-TES is integrated with Brayton combined-cycle power generation. The paper shows the design approach of the particle-TES system and its economic potential for bulk energy storage. The advantage of the particle-TES system as a promising bulk energy storage method is its ability to economically support dispatchable renewable grid penetration for larger capacity and longer discharging hours than current battery storage technologies.

25 ENERGY STORAGE↗

Efficient prediction of concentrating solar power plant productivity using data clustering

Concentrating solar power (CSP) plants convert solar energy to electricity and can be deployed with a thermal storage capability to shift electricity generation from time periods with available solar resource to those with high electricity demand or electricity price. Rigorous optimization of plant design and operational strategies can improve the market-competitiveness and commercial viability; however, such optimization may require hundreds of annual performance simulations, each of which can be computationally expensive when including considerations such as optimization of dispatch scheduling, sub-hourly time resolution, and stochastic effects due to uncertain weather or electricity price forecasts. This paper proposes a methodology to reduce the computational burden associated with simulation of electricity yield and revenue for CSP plants over a single- or multi-year period. Data-clustering techniques are employed to select a small number of limited-duration time blocks for simulation that, when appropriately weighted, can reproduce generation and revenue over a single year or within each year of a multi-year period. After selection of appropriate data features and weighting factors defining similarity between time-series profiles, the methodology captured annual revenue within 2.3%, 1.7%, or 1.2% using simulation of 10, 30, or 50 three-day exemplar time blocks, respectively, for each of three single-year location/weather/market scenarios and five plant configurations ranging from low to high solar multiple and storage capacity. When applied to multi-year datasets, the proposed methodology can capture inter-year variability that is unavailable from typical meteorological year (TMY) datasets while simultaneously requiring simulation of less than a single year of data.

14 SOLAR ENERGY↗

Separating Nuclear Reactors from the Power Block with Heat Storage: A New Power Plant Design Paradigm

The Massachusetts Institute of Technology (MIT), Idaho National Laboratory (INL) and the Electric Power Research Institute (EPRI) conducted a workshop on Separating Nuclear Reactors from the Power Block with Heat Storage: A New Power Plant Design Paradigm. The workshop was held as three webinars (July 29, August 12 and August 26, 2020). These proceedings include this abstract, an executive summary, the main report and presentations. There are two reasons to consider a new design paradigm. First, the market is changing with (1) the addition of variable wind and solar that results in highly volatile electricity prices and (2) the goal of a low-carbon economy that requires (a) economic dispatchable electricity that is now provided by natural gas turbines in the United States and (b) heat for industry and commerce. Second, nuclear plant requirements have changed in the last 50 years suggesting that a lower-cost plant layout may be to separate the nuclear island from the power block with a clear separation of the nuclear island with nuclear requirements and the power block built to industrial standards.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Model, Design, and Control for Power Conversion in Wave Energy Converter System

Wave energy, if all been harvested along the U.S. coastline, can power around 65% of the energy consumption in U.S.. Comparing to other renewable energy sources like solar or wind, ocean wave can provide up to 90% of steady uptime. With the high energy density (2-3 kW/m 2 ), it can produce more energy with the same amount of installation area comparing to the energy density of wind turbine (0.6 kW/m 2 ) and solar panel(0.2 kW/m 2 ). The predictability of wave provides advantages like planning installation, power dispatching, and maintenance activities. Although with all these advantages, wave energy converter system is still in the research stage due to its high system cost per electricity production. One of the challenges that need to be solved is the irregularity from the wave motion that leads to high instantaneous peak power into the wave energy converter, which usually reaches up to 10 - 20 times of the average power. The high peak power will not only bring high mechanical/electrical stress but also result in an overrating design of the components in the system. Another obstacle that prevents the wave energy system from moving forward is the high testing cost from the validations in wave-energy-test sites or tank-test sites. A high-fidelity multi-disciplinary system model, including hydrodynamics, mechanical dynamics, electromagnetics, and power electronics, is needed to predict the behavior of the system and reduce the cost of design validation.

16 TIDAL AND WAVE POWER↗

OpenACC Unified Programming Environment for Multi-hybrid Acceleration with GPU and FPGA

Accelerated computing in HPC such as with GPU, plays a central role in HPC nowadays. However, in some complicated applications with partially different performance behavior is hard to solve with a single type of accelerator where GPU is not the perfect solution in these cases. We are developing a framework and transpiler allowing the users to program the codes with a single notation of OpenACC to be compiled for multi-hybrid accelerators, named MHOAT (Multi-Hybrid OpenACC Translator) for HPC applications. MHOAT parses the original code with directives to identify the target accelerating devices, currently supporting NVIDIA GPU and Intel FPGA, dispatching these specific partial codes to background compilers such as NVIDIA HPC SDK for GPU and OpenARC research compiler for FPGA, then assembles binaries for the final object with FPGA bitstream file. In this paper, we present the concept, design, implementation, and performance evaluation of a practical astrophysics simulation code where we successfully enhanced the performance up to 10 times faster than the GPU-only solution.

Boku, Taisuke↗

Exploring the design space of PV-plus-battery system configurations under evolving grid conditions

In this study, we explore how the energy and capacity values of coupled systems comprising solar photovoltaic arrays and battery storage (PV-plus-battery systems) could evolve over time based on the evolution of the bulk power system. Using a price-taker model with simulated hourly energy and capacity prices projected from the present to 2050, we simulate the revenue-maximizing dispatch of a range of DC-coupled PV-plus-battery configurations in three locations in the United States. These configurations are defined by the inverter loading ratio (ILR, the ratio of the PV array capacity to the inverter capacity, which we vary from 1.4 to 2.6) and the battery-inverter ratio (BIR, the ratio of the battery power capacity to the inverter capacity, which we vary from 0.25 to 1.0). Based on each configuration's total value, we estimate the breakeven costs needed to justify each incremental increase in ILR (holding BIR constant) or BIR (holding ILR constant). We find that, in a future with low-cost renewable energy technologies, PV-plus-battery system ILRs can be economically increased to around 2.0-2.4 at a BIR of 1.0, depending on solar resource. Our results indicate that a likely evolution of PV-plus-battery system design will be increasingly greater battery power capacity to mitigate the declining PV capacity value, which will, in turn, enable increasingly higher ILRs to further increase energy value. The extent to which PV-plus-systems will be deployed with increasingly higher ILRs depends primarily on whether PV cost declines outpace declining value and increasing curtailment over time.

14 SOLAR ENERGY↗

Photovoltaic Analysis and Response Support (PARS) Platform for Solar Situational Awareness and Resiliency Services

The project's primary objective is to develop a digital-twin based Photovoltaic (PV) Analysis and Response Support (PARS) platform, which aims to provide real-time situational awareness and optimal response plans. This platform is designed to enhance the performance of hybrid PV systems, making them competitive with or even superior to conventional generation resources. The PARS platform enabled the project team to develop and evaluate an extensive suite of grid support functionalities for the hybrid PV systems to enhance grid performance, across key areas including visibility, dispatchability, security, resilience, and reliability. Given the global push toward achieving 100% clean energy by 2035, there is a significant increase in the integration of inverter-based resources (IBRs) throughout the energy grid. Effectively managing the inherent variability and uncertainty associated with IBRs is crucial for ensuring cost-effectiveness, reliability, and security in both the main grid and islanded microgrids. Constrained to a limited array of IEEE test systems or standard feeder models, traditional IBR modeling struggles to assimilate new field data, accurately reflect system dynamics, and adapt to the evolving energy landscape. In our project, we embraced a Digital Twin (DT) strategy for crafting the PARS platform. A digital twin acts as a precise virtual counterpart of a physical system, built on historical data and continuously honed with real-time insights. This enables the high-fidelity DT to accurately mirror current system operations and forecast future scenarios. Consequently, the PARS platform becomes an ideal environment for testing and refining monitoring, control, power, and energy management algorithms designed to boost hybrid PV system performance. The defining feature of the PARS platform, distinguishing it from other advanced simulation tools, is its exceptional adaptability. This is achieved by employing actual network topologies and utilizing real-time field data for fine-tuning and calibration, ensuring a close emulation of real-world conditions. The project deliverables include: 1) High-fidelity IBR models and tools for real-time parameterization, utilizing real-time field measurements to refine IBR models for enhanced accuracy and performance; 2) Grid-forming and Grid-following capabilities to deliver resilience services, including blackstart, voltage and frequency support, cold-load pick-up, power reserves, and three-phase load balancing across grid-connected and microgrid settings; 3) Machine learning-based forecasting tools and methods for generating synthetic data and topologies, creating diverse and realistic simulation environments for evaluating varied operational scenarios; 4) Advanced microgrid power and energy management algorithms for optimizing the integration and operation of PV, storage, and demand response resources within both feeder and community scales. The power grid data sets are provided by four utility companies in North Carolina and the New York Power Administration. Acting as industry advisors, our industry partners communicated stakeholder needs and regulatory standards to the research teams, aiding technology transfer by incorporating the developed methodologies into their daily operations. This collaboration ensures that the PARS platform, functioning as a power system digital twin, enhances our understanding of IBR dynamic behaviors and enables the development and evaluation of IBR control functions that match or exceed the capabilities of conventional synchronous generators.

14 SOLAR ENERGY↗

Virtual Battery Aggregator (Virtual Battery Aggregator for Distributed Energy Resource Management Systems)

Distributed energy resource management systems (DERMS) are being deployed in feeders with high distributed energy resource (DER) penetration to provide visibility of DERs and enable DER control strategies for grid operators. DERMS can support centralized grid controls by aggregating individual DER information into a single virtual DER model. This codebase creates algorithms for a DERMS platform that are able to aggregate a set of DERs that can be modeled as batteries, create a virtual battery model for centralized grid controls, and dispatch power setpoints to the individual DERs based on a desired virtual power setpoint received from the centralized grid control. It integrates with existing co-simulation frameworks and models for buildings, DERs, and distribution systems. While the DERMS is designed to work with batteries, it can be used with any DER that can be defined by a generalized battery model.

Blonsky, Michael↗

High-Fidelity and High-Performance Computational Simulations for Rapid Design Optimization of Sulfur Thermal Energy Storage (CRADA Report)

NREL and Element 16 collaborated on sulfur thermal energy storage modeling using NREL’s high performance computing (HPC) resources to assist its application in industrial processes. Industrial process heat (IPH) accounts for ~70% of US manufacturing energy use and is primarily produced by fossil fuel combustion. Approximately, 1500 TWht (~60% Terawatt hour thermal) of IPH demand is in the temperature range of 100-300°C. Industrial applications in this temperature range include drying, hydrothermal processing, thermal enhanced oil recovery, food and beverage, bioethanol production, etc. Cost-effective thermal energy storage (TES) that increases the utilization of waste and renewable heat (solar, geothermal, etc.) could provide significant energy savings and reliable heat sources, decrease emissions, and increase US manufacturing competitiveness through reductions in fuel consumption. This HPC4EI project facilitated Element 16’s development of low-cost and high-impact molten sulfur TES for dispatchable IPH. The development of a high-fidelity model validated by experimental data and HPC simulations enabled the successful resolution of the complex interplay between fluid dynamics and heat transfer processes during transient operation of sulfur TES, overcoming the numerical challenges posed by the non-linear temperature-dependent physical properties of sulfur. The project helped accelerate Element 16’s molten sulfur TES product design and support its broad applications.

25 ENERGY STORAGE↗

Hydropower and environmental flow management: System-level trade-offs at Glen Canyon Dam

The research focuses on the Colorado River Basin, specifically examining the Glen Canyon Dam (GCD) and its influence on surrounding aquatic ecosystems. This area is crucial due to its role in hydropower production and its impact on downstream environments, including the Grand Canyon National Park. This study explores the integration of environmental factors into hydro dispatch modeling at GCD to tackle ecological challenges posed by the invasive smallmouth bass (SMB). Utilizing the GTMax SL and SERM models, the research assesses the effects of SMB control experiments on hydropower generation, economic value, and grid stability. The study examines the financial and economic impacts of bypass flows designed to release colder water to prevent SMB spawning, which can significantly reduce hydropower output and increase costs. The research identifies that declining reservoir levels and rising water temperatures in Lake Powell have facilitated SMB spawning, posing a threat to native fish populations like the endangered humpback chub. The findings highlight the importance of adaptive management strategies to balance ecological preservation with hydropower generation amid long-term weather-related challenges. The study underscores the need for comprehensive assessments of flow options to prevent SMB establishment below GCD, considering the broader implications for sediment dynamics and ecological interactions.

Ecological impact assessment↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

H ∞ Control for Energy Dispatch in Autonomous Nanogrid With Communication Delays

This paper proposes an optimal controller and estimator for energy dispatch to balance the power supply and demand considering communication delays. The proposed algorithm involves modeling an autonomous nanogrid (ANG) consisting of distributed energy resources, energy storage systems, loads, an $H$ ∞ controller with a reference power modulation technique, and a state estimator. The ANG was developed to express the dynamic supply-demand energy balance of a nanogird system. Reference power modulation was designed to generate the desired ESS power based on the imbalanced energy. Random communication delays were modeled using a stochastic variable satisfying the Bernoulli random binary distribution. The optimal $H$ ∞ controller and estimator were developed using a linear matrix inequality approach to exponentially stabilize the closed-loop system. Simulations were performed using real daily demand forecasts obtained from the Korea Meteorological Administration to demonstrate the effectiveness of the proposed real-time optimization algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Low-Cost Sulfur Thermal Storage for Solar Industrial Process Heat Applications

Industrial process heat (IPH) is one of the largest energy demands in U.S., representing about 10% of all domestic energy consumption. Fuel costs to generate this industrial process heat are generally a top three cost for industry, a major component in American manufacturing competitiveness. Roughly 60% of US IPH demand (about 6,500 TBtu annually) falls in the medium-temperature range of 100–250 °C. While concentrated solar thermal (CST) technologies can provide a cost-effective source of heat in this temperature range, solar intermittency limits their adoption in industries that operate 24/7. Element 16 Technologies, Inc. developed a low-cost sulfur thermal energy storage (TES) technology to bridge this gap by capturing excess solar heat during the day and dispatching it reliably during non-solar hours. The core innovation is the use of sulfur, an abundant, industrial waste byproduct that costs ten times less than molten salt used in commercial TES systems. The overall goal of the project was to advance the design and development of molten sulfur TES to a manufacturing-relevant prototype stage for solar industrial process heat applications, while establishing and validating a realistic pathway to commercial success. Key tasks included corrosion and mechanical durability testing to identify cost-effective materials, design investigations using physics-based simulation tools, techno-economic evaluations of system lifetime costs, and pilot-scale testing for performance verification. Corrosion testing of steel alloys under cyclic molten sulfur conditions showed that austenitic stainless steels in the 300 series performed particularly well, with no structural degradation of welds or joints. Thermal cyclic testing of pilot sulfur TES units up to 1.5 MWh quantified charge/discharge rates, heat losses, round-trip efficiency and validated the system's capability to operate effectively under intermittent charging conditions. A techno-economic model, informed by sulfur TES performance model validated using pilot test data, showed that hybrid solar+sulfur TES+NG boiler systems are economically competitive with incumbent natural gas boilers for multiple locations in the southwest US. In summary, this project established molten sulfur TES as a technically viable pathway to improve economic competitiveness of American manufacturing by lowering the cost of solar industrial process heat.

14 SOLAR ENERGY↗

Power System Resilience Considering Hurricane Storms and Generator Step-up Transformers

Power system resilience describes the system’s ability to withstand and recover quickly from unexpected power outages due to extreme events. As society’s electrification continues at a rapid rate, it is imperative electric infrastructure is designed and operated with extra security. This work studies the impact of severe hurricane storms on the power system located along the United States’ Eastern Seaboard. Specific focus is designated to steady state system operation and loss of large generation step up power transformers. A series of phasor domain power system simulations are conducted to determine the critical point at which the system loses steady state operability. Additionally, active power load shedding and generator dispatching are studied as mitigation and recovery strategies. Results indicate generator dispatching as an effective proactive mitigation strategy and load shedding as an effective recovery strategy.

Liu, Yilu↗