Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “degradation rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Global protein turnover quantification in Escherichia coli reveals cytoplasmic recycling under nitrogen limitation

Protein turnover is critical for proteostasis, but turnover quantification is challenging, and even in well-studied E. coli, proteome-wide measurements remain scarce. Here, we quantify the turnover rates of ~3200 E. coli proteins under 13 conditions by combining heavy isotope labeling with complement reporter ion quantification and find that cytoplasmic proteins are recycled when nitrogen is limited. We use knockout experiments to assign substrates to the known cytoplasmic ATP-dependent proteases. Surprisingly, none of these proteases are responsible for the observed cytoplasmic protein degradation in nitrogen limitation, suggesting that a major proteolysis pathway in E. coli remains to be discovered. Lastly, we show that protein degradation rates are generally independent of cell division rates. Thus, we present broadly applicable technology for protein turnover measurements and provide a rich resource for protein half-lives and protease substrates in E. coli, complementary to genomics data, that will allow researchers to study the control of proteostasis.

59 BASIC BIOLOGICAL SCIENCES↗

Durable, pure water–fed, anion-exchange membrane electrolyzers through interphase engineering

Anion-exchange membrane water electrolyzers (AEMWEs) promise scalable, low-cost hydrogen production but are limited by the electrochemical instability of their anode ionomers. We report interphase engineering using inorganic-containing molecular additives that coassemble with ionomer, enabling pure water-fed AEMWEs to operate with a degradation rate <0.5 millivolt per hour at 2.0 amperes per square centimeter and 70°C-a >20-fold durability improvement. Analysis of different additives and ionomers shows that the stabilization mechanism involves cross-links between metal oxo/hydroxo oligomers and ionomers. Under operation, the inorganic additive enriches, forming an interphase near the water-oxidation catalyst that passivates the anode ionomer against continuous degradation while maintaining mechanical integrity and hydroxide conductivity. This additive-based interphase-engineering strategy provides a path to durable AEMWEs that operate without supporting electrolytes and is adaptable across diverse catalysts and ionomers for electrochemical technologies.

Hou, Shujin↗

Fluor Solvent Evaluation and Testing New Scope: Techno-economic Assessment of EEMPA Solvent for CO 2 Separations from Natural Gas Combined Cycle Power Plant

In this project, a techno-economic analysis (TEA) and sensitivity studies were conducted to assess the PNNL’s leading water-lean CO 2 capture solvent, EEMPA, for capture CO 2 from a natural gas combined cycle (NGCC) power plant at different levels of capture rate. Process models for the NGCC power plant, integrated with EEMPA carbon capture processes, were developed in Aspen Plus V14 using the most up-to-date property package for EEMPA-H 2 O-CO 2 system. The TEA evaluated EEMPA carbon capture process at normal capture rates (90%, 95% and 97%) against Case B32B (Cansolv) described in NETL Rev4a baseline report, and at higher capture rates aimed at achieving zero or negative emissions from the power plant (400 ppmv, 200 ppmv, and 100 ppmv CO 2 in exhaust gas), compared to typical Direct Air Capture (DAC) technologies. A manuscript was drafted for peer-reviewed publication. The results suggested that the carbon capture cost reaches a minimum of $\$$53.7/tonne CO 2 at 90% capture rate. Compared to Cansolv, one of the industrial benchmarks, EEMPA demonstrates 2-4% cost savings at capture rates up to 95%, but minimal savings at higher capture rate. The water lean-solvent system proves economically attractive for achieving moderate negative emissions (about 200 ppmv CO 2 in exhaust gas, and equivalent to 50% CO 2 removal from air) for NGCC flue gas, with marginal capture costs comparable to direct air capture (DAC) technologies. A sensitivity analysis results reveal that its economic advantage, unaffected by EEMPA price due to low solvent loss and degradation rate. However, the marginal carbon capture cost exceeds $\$$1,000/tonne CO 2 when transitioning from moderate to extreme negative emissions (100 ppmv CO 2 in exhaust gas), suggesting that water-lean solvents may not be economically competitive with other DAC technologies for removing more than 75% CO 2 from air. In addition, initial connection was established with Technology Center Mongstad (TCM) for a potential pilot testing proposal. However, detailed modeling and proposal preparation was not conducted due to the delay of non-disclosure agreement.

20 FOSSIL-FUELED POWER PLANTS↗

Life capability of the silver electrode in alkaline electrochemical cells

Estimates of silver electrode degradation rates were made by comparing the recently measured capacities with the reported early life capacities. Chemical analyses were carried out to determine the extent of silver loss from the electrode and its distribution throughout the cell components. The results established that the silver electrode is very stable when stored at reduced temperatures in the range of 0 to -51 C, in which it exhibits a permanent degradation in capacity of 0.5%/year. The results also indicated that the silver electrode is not quite as stable when operated and stored at room temperature, where it exhibits permanent degradation in the range of 3% to 14%/year. These results were employed in predicting the life capability of the proposed new Ag-H2 cell and also in assessing the merits of employing silver electrodes in long-life probe batteries.

Frank, H. A.↗

A Comprehensive Experimental Study on Microstructure‐Graded Graphite Anodes for Enhancing Fast‐Charging Capability of Lithium‐Ion Batteries

Lithium‐ion batteries with high gravimetric capacity density and improved cycle life performance under fast‐charging conditions are crucial for widespread electric vehicle (EV) adoption. This study investigates how designing graphite anode microstructure, specifically porosity, and particle‐size gradients, improves lithium‐ion (Li + ) transport during fast‐charging conditions. Three‐layered graphite anodes with varying porosity (24%, 36%, 46%) and particle size gradients (3, 5, 10 μm) were compared to a conventional single‐layered electrode in half‐cell configurations. At room temperature and high discharge rate (2C), both gradient structures showed significantly enhanced capacity retention (80% and 67% vs. 50%) compared to the conventional electrode, highlighting the effectiveness of microstructure engineering for fast charging. The study also investigated the temperature's impact on cycle life. After 200 cycles at 2°C and 45°C, all gradient structures demonstrated superior capacity retention (≈80%) compared to the conventional electrode (35%), suggesting the gradients mitigate degradation rate at high temperatures. Electrochemical impedance spectroscopy confirmed superior Li+ diffusion and lower resistivity in gradient electrodes. Simulations explored the influence of gradient profiles on reaction kinetics across the electrode thickness. Overall, this research demonstrates that the fast‐charging capability of graphite electrodes can be greatly enhanced by engineering the electrode microstructure, thereby making EV technology more accessible and appealing.

Ahmadi, Soma↗

Update on MEA AST [Slides]

Goals: Developing MEA ASTs for Heavy Duty Applications: 1) New protocol published within M2FCT in Nov 2022; 2) Work is ongoing to understand the degradation rates of SOA (State of the Art) materials; 3) The protocol will be updated (If needed) by the end of the Fiscal Year (Sept 2023). Updating component specific ASTs: 1) Catalyst AST: Extend from 30K cycles to 90K cycles to reflect LDV and HDV lifetimes of 5000 (8000 hours) and 25000 (30000 hours); 2) Catalyst Supports: Quantifying carbon corrosion during H 2 /Air AST using NDIR; 3) Membrane Degradation: Membrane thinning and FER measurement. Validating developed ASTs with modeled drive cycles and experiments.

08 HYDROGEN↗

Proton-Conducting Solid Oxide Electrolysis Cells for Large-scale Hydrogen Production at Intermediate Temperatures

Proton-conducting electrolyte based SOECs offer potential for operation at low to intermediate temperatures. Although yttrium-doped barium zirconate (BZY) and ceria-doped barium zirconate (BCY) have conductivity of 0.01 and 0.017 S.cm -1 respectively at 650C in comparison to the conductivity of 0.015 S.cm -1 for 8-YSZ at 850°C, there remains technology gaps and research needs related to understanding of chemical and structural stability in oxidizing and/or reducing atmospheres at intermediate temperatures, material processing and densification techniques, high polarization losses, and electrode poisoning due to intrinsic and extrinsic gas phase contaminants. Synthesis methods have produced proton-conducting materials and cells that met degradation rate targets, showcasing stable hydrogen production. Improved performance was evident in the HSOEC cell, achieving higher hydrogen production at a lower operating temperature compared to standard cells. Collaborations with multiple research facilities ensured scaling up of synthesis processes and milestone achievements for large-scale manufacturing. Assessment of contaminants revealed their adverse effects on electrode performance and structural stability. Contaminants like Cr and Si compounds, in high humidity, degraded electrodes by forming stable silicate and chromates, inhibiting active surface reactions. Getter materials showed promise in capturing contaminants, suggesting potential for mitigation.

08 HYDROGEN↗

Understanding of bacterial lignin extracellular degradation mechanisms by Pseudomonas putida KT2440 via secretomic analysis

Abstract Background Bacterial lignin degradation is believed to be primarily achieved by a secreted enzyme system. Effects of such extracellular enzyme systems on lignin structural changes and degradation pathways are still not clearly understood, which remains as a bottleneck in the bacterial lignin bioconversion process. Results This study investigated lignin degradation using an isolated secretome secreted by Pseudomonas putida KT2440 that grew on glucose as the only carbon source. Enzyme assays revealed that the secretome harbored oxidase and peroxidase/Mn 2+ -peroxidase capacity and reached the highest activity at 120 h of the fermentation time. The degradation rate of alkali lignin was found to be only 8.1% by oxidases, but increased to 14.5% with the activation of peroxidase/Mn 2+ -peroxidase. Gas chromatography–mass spectrometry (GC–MS) and two-dimensional 1 H– 13 C heteronuclear single-quantum coherence (HSQC) NMR analysis revealed that the oxidases exhibited strong C–C bond ( β-β , β -5, and β -1) cleavage. The activation of peroxidases enhanced lignin degradation by stimulating C–O bond ( β -O-4) cleavage, resulting in increased yields of aromatic monomers and dimers. Further mass spectrometry-based quantitative proteomics measurements comprehensively identified different groups of enzymes particularly oxidoreductases in P. putida secretome, including reductases, peroxidases, monooxygenases, dioxygenases, oxidases, and dehydrogenases, potentially contributed to the lignin degradation process. Conclusions Overall, we discovered that bacterial extracellular degradation of alkali lignin to vanillin, vanillic acid, and other lignin-derived aromatics involved a series of oxidative cleavage, catalyzed by active DyP-type peroxidase, multicopper oxidase, and other accessory enzymes. These results will guide further metabolic engineering design to improve the efficiency of lignin bioconversion. Graphical Abstract

09 BIOMASS FUELS↗

Interpreting statistics of small lunar craters

Some of the wide variations in the crater-size distributions in lunar photography and in the resulting statistics were interpreted as different degradation rates on different surfaces, different scaling laws in different targets, and a possible population of endogenic craters. These possibilities are reexamined for statistics of 26 different regions. In contrast to most other studies, crater diameters as small as 5 m were measured from enlarged Lunar Orbiter framelets. According to the results of the reported analysis, the different crater distribution types appear to be most consistent with the hypotheses of differential degradation and a superposed crater population. Differential degradation can account for the low level of equilibrium in incompetent materials such as ejecta deposits, mantle deposits, and deep regoliths where scaling law changes and catastrophic processes introduce contradictions with other observations.

Schultz, P. H.↗

Results of electric-vehicle propulsion system performance on three lead-acid battery systems

Three types of state of the art 6 V lead acid batteries were tested. The cycle life of lead acid batteries as a function of the electric vehicle propulsion system design was determined. Cycle life, degradation rate and failure modes with different battery types (baseline versus state of the art tubular and thin plate batteries were compared. The effects of testing strings of three versus six series connected batteries on overall performance were investigated. All three types do not seem to have an economically feasible battery system for the propulsion systems. The tubular plate batteries on the load leveled profile attained 235 cycles with no signs of degradation and minimal capacity loss.

Ewashinka, J. G.↗

Results of electric-vehicle propulsion system performance on three lead-acid battery systems

Three types of state of the art 6 V lead acid batteries were tested. The cycle life of lead acid batteries as a function of the electric vehicle propulsion system design was determined. Cycle life, degradation rate and failure modes with different battery types (baseline versus state of the art tubular and thin plate batteries) were compared. The effects of testing strings of three versus six series connected batteries on overall performance were investigated. All three types do not seem to have an economically feasible battery system for the propulsion systems. The tubular plate batteries on the load leveled profile attained 235 cycles with no signs of degradation and minimal capacity loss.

Ewashinka, J. G.↗

Carbonyl Identification and Quantification Uncertainties for Oxidative Polymer Degradation

The most revealing indicator for oxidative processes or state of degraded plastics is usually carbonyl formation, a key step in materials degradation as part of the carbon cycle for man-made materials. Hence, the identification and quantification of carbonyl species with infrared spectroscopy have been the method of choice for generations, thanks to their strong absorbance and being an essential intermediate in carbon oxidation pathways. Despite their importance, precise identification and quantification can be challenging and rigorous fully traceable data are surprisingly rare in the existing literature. An overview of the complexity of carbonyl quantification is presented by the screening of reference compounds in solution with transmission and polymer films with ATR IR spectroscopy, and systematic data analyses. Significant variances in existing data and their past use have been recognized. Guidance is offered how better measurements and data reporting could be accomplished. Experimental variances depend on the combination of uncertainty in exact carbonyl species, extinction coefficient, contributions from neighboring convoluting peaks, matrix interaction phenomena and instrumental variations in primary IR spectral acquisition (refractive index and penetration depth for ATR measurements). In addition, diverging sources for relevant extinction coefficients may exist, based on original spectral acquisition. For common polymer degradation challenges, a relative comparison of carbonyl yields for a material is easily accessible, but quantification for other purposes, such as degradation rates and spatially dependent interpretation, requires thorough experimental validation. All variables featured in this overview demonstrate the significant error margins in carbonyl quantification, with exact carbonyl species and extinction coefficients already being major contributors on their own.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

System statistical reliability model and analysis

A digital computer code was developed to simulate the time-dependent behavior of the 5-kwe reactor thermoelectric system. The code was used to determine lifetime sensitivity coefficients for a number of system design parameters, such as thermoelectric module efficiency and degradation rate, radiator absorptivity and emissivity, fuel element barrier defect constant, beginning-of-life reactivity, etc. A probability distribution (mean and standard deviation) was estimated for each of these design parameters. Then, error analysis was used to obtain a probability distribution for the system lifetime (mean = 7.7 years, standard deviation = 1.1 years). From this, the probability that the system will achieve the design goal of 5 years lifetime is 0.993. This value represents an estimate of the degradation reliability of the system.

Lekach, V. S.↗

Ferroelastic Hysteresis in Thin Films of Methylammonium Lead Iodide

Mechanical strain can modify the structural and electronic properties of methylammonium lead iodide MAPbI 3 . The consequences of ferroelastic hysteresis, which involves the retention of structural memory upon cycles of deformation, are reported for polycrystalline thin films of MAPbI 3 . Repeatedly bent films were examined using grazing incidence wide-angle X-ray scattering (GIWAXS) to quantitatively characterize the strains and proportions of twin domains. Approximate locations for the coercive stress and saturation on the ferroelastic stress–strain curve are identified, and changes to the stress–strain curve with cyclic strain are characterized. Notably, an external stress source, such as thermal stress from the substrate or a roll-to-roll printing setup, must apply at least |50| MPa to modify the proportions of different twins. The presence of specific twin domains is found to correlate to previously reported strain and defect heterogeneity in MAPbI 3 films. Domains from differently strained twin sets interact with each other. Long-term stability testing reveals that the domain walls are highly immobile over extended periods. Nucleation of new domain walls occurs for specific mechanical strains and correlates closely with degradation. Furthermore, these results help to explain the behavior of ion migration, degradation rate, and photoluminescence in thin films under compressive and tensile strain.

Defects↗

Degradation of Monocrystalline Silicon Photovoltaic Modules From a 10-Year-Old Rooftop System in Florida

A system of 180 monocrystalline aluminum back-surface field modules were installed in Cocoa, Florida, for 10 years. In total, 156 modules are characterized and compared to 3 controls. Power degradation rates vary between – 0.14% to – 3.22% per year, with median and average rates of –0.92% and –1.05% per year, respectively. The losses are primarily resistive with minor optical and recombination loss contributions. Electroluminescence imaging shows a characteristic pattern, which is shown to be resistive in nature when compared to photoluminescence. Resistive losses are due to corrosion of the rear contact Ag/solder interface and, to a much lesser degree, gridline Ag oxidation. Moisture ingress through the backsheet is likely responsible for mediating corrosion. Optical losses are due mostly to a combination of antireflection coating degradation, minor encapsulant browning, and delamination. Minor front contact corrosion may contribute to recombination. Furthermore, this study expands upon previous work on this vintage of the module by examining a large sample set, comprehensive characterization including techniques not previously used on these modules, and a comparison between two other systems of different climates.

14 SOLAR ENERGY↗

Towards linking lab and field lifetimes of perovskite solar cells

Metal halide perovskite solar cells (PSCs) represent a promising low-cost, thin-film photovoltaic (PV) technology, with unprecedented power conversion efficiencies (PCEs) obtained for both single-junction and tandem applications. To push PSCs toward commercialization, it is critical, albeit challenging, to understand device reliability under real-world outdoor conditions where multiple stress factors (e.g., light, heat, humidity) coexist, generating complicated degradation behaviors. It is necessary to identify accelerated indoor testing protocols - which can correlate specific stressors with observed degradation modes in fielded devices - to quickly guide PSC development. Here, we use a state-of-the-art p-i-n PSC stack (with PCE up to ~25.5%) to show that indoor accelerated stability tests can predict our 6-month outdoor aging tests. Device degradation rates under illumination and at elevated temperatures are most instructive for understanding outdoor device reliability. Further, we also find that the indium tin oxide (ITO)/self-assembled monolayer (SAM)-based hole transport layer (HTL)/perovskite interface most strongly affects our device operation stability. Improving the ion-blocking properties of the SAM HTL increases averaged device operational stability at 50 degree C-85 °C by a factor of ~2.8, reaching over 1000 h at 85 °C and to near 8200 h at 50 °C with a projected 20% degradation, which is among the best to date for high-efficiency p-i-n PSCs.

14 SOLAR ENERGY↗

Thermal oxidative degradation reactions of perfluoroalkylethers

The mechanisms operative in thermal oxidative degradation of Fomblin Z and hexafluoropropene oxide derived fluids and the effect of alloys and additives upon these processes are investigated. The nature of arrangements responsible for the inherent thermal oxidative instability of the Fomblin Z fluids is not established. It was determined that this behavior is not associated with hydrogen end groups or peroxy linkages. The degradation rate of these fluids at elevated temperatures in oxidizing atmospheres is dependent on the surface/volume ratio. Once a limiting ratio is reached, a steady rate appears to be attained. Based on elemental analysis and oxygen consumption data, CF2OCF2CF2O2, no. CF2CF2O, is one of the major arrangements present. The action of the M-50 and Ti(4 Al, 4 Mn) alloys is much more drastic in the case of Fomblin Z fluids than that observed for the hexafluoropropene derived materials. The effectiveness of antioxidation anticorrosion additives, P-3 and phospha-s-triazine, in the presence of metal alloys is very limited at 316 C; at 288 C the additives arrested almost completely the fluid degradation. The phospha-s-triazine appears to be at least twice as effective as the P-3 compound; it also protected the coupon better. The Ti(4 Al, 4 Mn) alloy degraded the fluid mainly by chain scission processes this takes place to a much lesser degree with M-50.

Paciorek, K. L.↗

Thermal oxidative degradation reactions of perfluoroalklethers

The objective of this contract was to investigate the mechanisms operative in thermal and thermal oxidative degradation of Fomblin Z and hexafluoropropene oxide derived fluids and the effect of alloys and additives upon these processes. The nature of arrangements responsible for the inherent thermal oxidative instability of the Fomblin Z fluids has not been established. It was determined that this behavior was not associated with hydrogen end-groups or peroxy linkages. The degradation rate of these fluids at elevated temperatures in oxidizing atmospheres was found to be dependent on the surface/volume ratio. Once a limiting ratio was reached, a steady rate appeared to be attained. Based on elemental analysis and oxygen consumption data, -CF2OCF2CF2O-, not -CF2CF2O-, is one of the major arrangements present. The action of the M-50 and Ti(4 Al, 4 Mn) alloys was found to be much more drastic in the case of Fomblin Z fluids than that observed for the hexalfuoropropane oxide derived materials. The effectiveness of antioxidation/anticorrosion additives, P-3 and phospha-s-triazine, in the presence of metal alloys was very limited at 316 C; at 288 C the additives arrested almost completely the fluid degradation. The phospha-s-triazine appeared to be at least twice as effective as the P-3 compound; it also protected the coupon better. The Ti(4 Al, 4 Mn) alloy degraded the fluid mainly by chain scission processes; this took place to a much lesser degree with M-50.

Paciorek, K. L.↗