Active diffraction gratings: Development and tests

We present the realization and characterization of an active spherical diffraction grating with variable radius of curvature to be used in grazing-incidence monochromators. The device consists of a bimorph deformable mirror on the top of which a diffraction grating with laminar profile is realized by UV lithography. The experimental results show that the active grating can optimize the beam focalization of visible wavelengths through its rotation and focus accommodation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Increasing energy coupling into plasma waves by tailoring the laser radial focal spot distribution in a laser wakefield accelerator

By controlling the focal spot quality with a deformable mirror, we are able to show that increasing the fraction of pulse energy contained within the central part of the focal spot, while keeping the total energy and central spot size constant, significantly increases the amount of energy transferred to the wakefield: Our measurements show that the laser loses significantly more laser energy and undergoes greater redshifting and that more charge is produced in the accelerated beam. Three dimensional particle in cell simulations performed with accurate representations of the measured focal spot intensity distribution confirm that energy in the wings of the focal spot is effectively wasted. Even though self-focusing occurs, energy in the wings of the focal spot distribution is not coupled into the wakefield, emphasising the vital importance of high quality focal spot profiles in experiments.

43 PARTICLE ACCELERATORS↗

Bi-photon generation with optimized wavefront by means of adaptive optics

The generation of entangled photon pairs using an optimal pump wavefront was realized in order to achieve a desirable free-space propagation. This optimization exploits a closed loop whis is based on a deformable mirror, a nonlinear crystal for spontaneous parametric down-conversion, the free-space propagation line and the single-photon coincidence electronics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherent control of plasma dynamics by feedback-optimized wavefront manipulation

Plasmas generated by an intense laser pulse can support coherent structures such as large amplitude wakefield that can affect the outcome of an experiment. We investigate the coherent control of plasma dynamics by feedback-optimized wavefront manipulation using a deformable mirror. The experimental outcome is directly used as feedback in an evolutionary algorithm for optimization of the phase front of the driving laser pulse. In this paper, we applied this method to two different experiments: (i) acceleration of electrons in laser driven plasma waves and (ii) self-compression of optical pulses induced by ionization nonlinearity. The manipulation of the laser wavefront leads to orders of magnitude improvement to electron beam properties such as the peak charge, beam divergence, and transverse emittance. The demonstration of coherent control for plasmas opens new possibilities for future laser-based accelerators and their applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recent results and future plans for a 45 actuator adaptive x-ray optics experiment at the advanced light source

We report on the current status of the Adaptive X-ray Optics project run by Lawrence Livermore National Laboratory (LLNL). LLNL is collaborating with the Advanced Light Source (ALS) to demonstrate a near real-time adaptive X-ray optic. To this end, a custom-built 45 cm long deformable mirror has been installed at ALS beamline 5.3.1 (end station 2) for a two-year period that started in September 2014. We will outline general aspects of the instrument, present results from a recent experimental campaign and touch on future plans for the project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beyond optimization—supervised learning applications in relativistic laser-plasma experiments

We explore the applications of machine learning techniques in relativistic laser-plasma experiments beyond optimization purposes. We predict the beam charge of electrons produced in a laser wakefield accelerator given the laser wavefront change caused by a deformable mirror. Machine learning enables feature analysis beyond merely searching for an optimal beam charge, showing that specific aberrations in the laser wavefront are favored in generating higher beam charges. Supervised learning models allow characterizing the measured data quality as well as recognizing irreproducible data and potential outliers. Furthermore, we also include virtual measurement errors in the experimental data to examine the model robustness under these conditions. This work demonstrates how machine learning methods can benefit data analysis and physics interpretation in a highly nonlinear problem of relativistic laser-plasma interaction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New adaptive optics control strategy for petawatt-class laser chains

A new generation of ultra-high intensity femtosecond petawatt- and above-class lasers requires new approaches to wavefront corrections. New challenges for adaptive optics consist in overcoming the constraints of potentially bigger diameters, larger amplitude aberrations, faster optics, higher risk of damaging optical components and faster and easier maintenance. Here we present a new technology of a mechanical deformable mirror, which has a large stroke, high temporal stability, low hysteresis, no print-through effect, easy, safe and fast maintenance and an operating frequency up to 10 Hz. We propose the full correction of the final focal spot in the target chamber by a combination of a standard adaptive optics system, a simple focal plane camera and a phase retrieval correction process. We test the reliability of the correction system in terms of intensity variation and wavefront stability. We further verify correction robustness of the method on a large spectral bandwidth and finally perform a focal spot correction on a terawatt laser system in both low and high-power regimes. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of X-ray Wavefront Sensing Techniques for Adaptive Optics Control at the Advanced Photon Source

The planning and construction of new and upgraded high-brightness X-ray synchrotron and free electron laser sources, such as the Advanced Photon Source upgrade project (APS-U), are driving numerous opportunities to advance X-ray science and technologies. At the same time, an increasing number of highly diverse beamline experiments demand wavefront-preserving adaptive X-ray optics with both high precision and flexibility. At the APS, significant effort has been devoted to developing next-generation adaptive and corrective optics combined with state-of-the-art at-wavelength wavefront sensing techniques and an intelligent feedback control system for the automation and self-alignment of beamline optical systems. This article reviews recent achievements in these areas at the APS. Further, these include the development of in-situ wavefront sensing, the application in active feedback control of ultra-precision deformable mirrors, and the exploration of non-invasive wavefront sensing techniques for adaptive optics and beamline diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FOCAL PLANE WAVEFRONT SENSING USING RESIDUAL ADAPTIVE OPTICS SPECKLES

Optical imperfections, misalignments, aberrations, and even dust can significantly limit sensitivity in high-contrast imaging systems such as coronagraphs. An upstream deformable mirror (DM) in the pupil can be used to correct or compensate for these flaws, either to enhance the Strehl ratio or suppress the residual coronagraphic halo. Measurement of the phase and amplitude of the starlight halo at the science camera is essential for determining the DM shape that compensates for any non-common-path (NCP) wavefront errors. Using DM displacement ripples to create a series of probe and anti-halo speckles in the focal plane has been proposed for space-based coronagraphs and successfully demonstrated in the lab. We present the theory and first on-sky demonstration of a technique to measure the complex halo using the rapidly changing residual atmospheric speckles at the 6.5 m MMT telescope using the Clio mid-IR camera. The AO system's wavefront sensor measurements are used to estimate the residual wavefront, allowing us to approximately compute the rapidly evolving phase and amplitude of speckle halo. When combined with relatively short, synchronized science camera images, the complex speckle estimates can be used to interferometrically analyze the images, leading to an estimate of the static diffraction halo with NCP effects included. In an operational system, this information could be collected continuously and used to iteratively correct quasi-static NCP errors or suppress imperfect coronagraphic halos.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PALM-3000: EXOPLANET ADAPTIVE OPTICS FOR THE 5 m HALE TELESCOPE

We describe and report first results from PALM-3000, the second-generation astronomical adaptive optics (AO) facility for the 5.1 m Hale telescope at Palomar Observatory. PALM-3000 has been engineered for high-contrast imaging and emission spectroscopy of brown dwarfs and large planetary mass bodies at near-infrared wavelengths around bright stars, but also supports general natural guide star use to V ≈ 17. Using its unique 66 × 66 actuator deformable mirror, PALM-3000 has thus far demonstrated residual wavefront errors of 141 nm rms under ∼1'' seeing conditions. PALM-3000 can provide phase conjugation correction over a 6.''4 × 6.''4 working region at λ = 2.2 μm, or full electric field (amplitude and phase) correction over approximately one-half of this field. With optimized back-end instrumentation, PALM-3000 is designed to enable 10{sup –7} contrast at 1'' angular separation, including post-observation speckle suppression processing. While continued optimization of the AO system is ongoing, we have already successfully commissioned five back-end instruments and begun a major exoplanet characterization survey, Project 1640.

79 ASTRONOMY AND ASTROPHYSICS↗

TECHNIQUES FOR HIGH-CONTRAST IMAGING IN MULTI-STAR SYSTEMS. I. SUPER-NYQUIST WAVEFRONT CONTROL

Direct imaging of extra-solar planets is now a reality with the deployment and commissioning of the first generation of specialized ground-based instruments (GPI, SPHERE, P1640, and SCExAO). These systems allow of planets 10{sup 7} times fainter than their host star. For space-based missions (EXCEDE, EXO-C, EXO-S, WFIRST), various teams have demonstrated laboratory contrasts reaching 10{sup −10} within a few diffraction limits from the star. However, all of these current and future systems are designed to detect faint planets around a single host star, while most non-M-dwarf stars such as Alpha Centauri belong to multi-star systems. Direct imaging around binaries/multiple systems at a level of contrast allowing detection of Earth-like planets is challenging because the region of interest is contaminated by the host star's companion in addition to the host itself. Generally, the light leakage is caused by both diffraction and aberrations in the system. Moreover, the region of interest usually falls outside the correcting zone of the deformable mirror (DM) with respect to the companion. Until now, it has been thought that removing the light of a companion star is too challenging, leading to the exclusion of many binary systems from target lists of direct imaging coronographic missions. In this paper, we will show new techniques for high-contrast imaging of planets around multi-star systems and detail the Super-Nyquist Wavefront Control (SNWC) method, which allows wavefront errors to be controlled beyond the nominal control region of the DM. Our simulations have demonstrated that, with SNWC, raw contrasts of at least 5 × 10{sup −9} in a 10% bandwidth are possible.

79 ASTRONOMY AND ASTROPHYSICS↗

DESIGN OF PHASE INDUCED AMPLITUDE APODIZATION CORONAGRAPHS OVER SQUARE APERTURES

The purpose of this paper is to present the results of a theoretical study pertaining to the feasibility of Phase Induced Amplitude Apodization (PIAA) units using deformable mirrors (DMs). We begin by reviewing the general derivation of the design equations driving PIAA. We then show how to solve these equations for square apertures and show the performance of pure PIAA systems in the ray optics regime. We tie these design equations into the study of edge diffraction effects and provide a general expression for the field after a full propagation through a PIAA coronagraph. Third, we illustrate how a combination of pre- and post-apodizers yields a contrast of 10{sup -10} even in the presence of diffractive effects, for configuration with neither wavefront errors or wavefront control. Finally, we present novel PIAA configurations over square apertures which circumvent the constraints on the manufacturing of PIAA optics by inducing the apodization with two square DMs. Such solutions rely on pupil size smaller than currently envisioned static PIAA solutions and thus require aggressive pre- and post-apodizing screens in order to mitigate for diffractive effect between the two mirrors. As a result they are associated with significant loss in performance, throughput in particular.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhanced high-order harmonic generation driven by a wavefront corrected high-energy laser

We developed and implemented an experimental setup for the generation of high-energy high-order harmonics in argon gas for nonlinear experiments in the extreme ultraviolet (XUV) spectral range. High-order harmonics were generated by loosely focusing a high-energy laser pulse centered around 800 nm into a gas cell filled with argon in a phase-matching condition. The wavefront distortions of the driving pulse were corrected by a deformable mirror, and the XUV conversion efficiency was significantly improved due to the excellent beam profile at focus. A high-damage-threshold beam splitter was used to eliminate high-energy driving pulses co-propagating with high-order harmonics. The setup has a potential to provide intense ultrashort XUV pulses reaching the intensity levels required for nonlinear experiments in the XUV spectral range.

74 ATOMIC AND MOLECULAR PHYSICS↗

ARTIFICIAL INCOHERENT SPECKLES ENABLE PRECISION ASTROMETRY AND PHOTOMETRY IN HIGH-CONTRAST IMAGING

State-of-the-art coronagraphs employed on extreme adaptive optics enabled instruments are constantly improving the contrast detection limit for companions at ever-closer separations from the host star. In order to constrain their properties and, ultimately, compositions, it is important to precisely determine orbital parameters and contrasts with respect to the stars they orbit. This can be difficult in the post-coronagraphic image plane, as by definition the central star has been occulted by the coronagraph. We demonstrate the flexibility of utilizing the deformable mirror in the adaptive optics system of the Subaru Coronagraphic Extreme Adaptive Optics system to generate a field of speckles for the purposes of calibration. Speckles can be placed up to 22.5 λ/D from the star, with any position angle, brightness, and abundance required. Most importantly, we show that a fast modulation of the added speckle phase, between 0 and π, during a long science integration renders these speckles effectively incoherent with the underlying halo. We quantitatively show for the first time that this incoherence, in turn, increases the robustness and stability of the adaptive speckles, which will improve the precision of astrometric and photometric calibration procedures. This technique will be valuable for high-contrast imaging observations with imagers and integral field spectrographs alike.

79 ASTRONOMY AND ASTROPHYSICS↗

Diagnostics, Control and Performance Parameters for the BELLA High Repetition Rate Petawatt Class Laser

A laser system producing controllable and stable pulses with high power and ultrashort duration at high repetition rate is a key component of a high energy laser-plasma accelerator (LPA). Precise characterization and control of laser properties are essential to understanding laser-plasma interactions required to build a 10-GeV class LPA. This study discusses the diagnostics, control and performance parameters of a 1 Hz, 1 petawatt (PW) class laser at the Berkeley Lab Laser Accelerator (BELLA) facility. The BELLA PW laser provided up to 46 J on target with a 1% level energy fluctuation and 1.3-μrad pointing stability. The spatial profile was measured and optimized by using a camera, wavefront sensor, and deformable mirror (ILAO system). The focus waist was measured to be r 0 = 53 μm and the fraction of energy within the circular area defined by the first minimum of the diffraction pattern (r = 67 μm) was 0.75. The temporal profile was controlled via the angle of incidence on a stretcher and a compressor, as well as an acousto-optic programmable dispersive. The temporal pulse shape was measured to be about 33 fs in full width at half maximum (WIZZLER and GRENOUILLE diagnostics). In order to accurately evaluate peak intensity, the energy-normalized peak fluence, and energy-normalized peak power were analyzed for the measured spatial and temporal mode profiles, and were found to be 15 kJ/(cm 2 J) with 6% fluctuation (standard deviation) and 25 TW/J with 5% fluctuation for 46-J on-target energy, respectively. This yielded a peak power of 1.2 PW and a peak intensity of 17×10 18 W/cm 2 with 8% fluctuation. A method to model the pulse shape for arbitrary compressor grating distance with high accuracy was developed. The pulse contrast above the amplified spontaneous emission pedestal was measured by SEQUOIA and found to be better than 10 9 . The first order spatiotemporal couplings (STCs) were measured with GRENOUILLE, and a simulation of the pulse's evolution at the vicinity of the target was presented. A maximum pulse front tilt angle of less than 7 mrad was achieved. The reduction of the peak power caused by the first order STCs was estimated to be less than 1%. Finally, the capabilities described in this paper are essential for generation of high quality electron beams.

47 OTHER INSTRUMENTATION↗

The Gemini Planet Imager: From Science to Design to Construction

The Gemini Planet Imager (GPI) is a facility instrument under construction for the 8-m Gemini South telescope. It combines a 1500 subaperture AO system using a MEMS deformable mirror, an apodized-pupil Lyot coronagraph, a high-accuracy IR interferometer calibration system, and a near-infrared integral field spectrograph to allow detection and characterization of self-luminous extrasolar planets at planet/star contrast ratios of 10{sup -7}. I will discuss the evolution from science requirements through modeling to the final detailed design, provide an overview of the subsystems and show models of the instrument's predicted performance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Contrast analysis and stability on the ExAO testbed

High-contrast adaptive optics systems, such as those needed to image extrasolar planets, are known to require excellent wavefront control and diffraction suppression. The Laboratory for Adaptive Optics at UC Santa Cruz is investigating limits to high-contrast imaging in support of the Gemini Planet Imager. Previous contrast measurements were made with a simple single-opening prolate spheroid shaped pupil that produced a limited region of high-contrast, particularly when wavefront errors were corrected with the 1024-actuator Boston Micromachines MEMS deformable mirror currently in use on the testbed. A more sophisticated shaped pupil is now being used that has a much larger region of interest facilitating a better understanding of high-contrast measurements. In particular we examine the effect of heat sources in the testbed on PSF stability. We find that rms image motion scales as 0.02 {lambda}/D per watt when the heat source is near the pupil plane. As a result heat sources of greater than 5 watts should be avoided near pupil planes for GPI. The safest place to introduce heat is near a focal plane. Heat also can effect the standard deviation of the high-contrast region but in the final instrument other sources of error should be more significant.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance of a MEMS-based AO-OCT system using Fourier Reconstruction

Adaptive optics (AO) and optical coherence tomography (OCT) are powerful imaging modalities that, when combined, can provide high-resolution (3.5 {micro}m isotropic), 3-D images of the retina. The AO-OCT system at UC Davis has demonstrated the utility of this technology for microscopic, volumetric, in vivo retinal imaging. The current system uses an AOptix bimorph deformable mirror (DM) for low-order, high-stroke correction and a 140-actuator Boston Micromachines DM for high-order correction. Developments to improve performance or functionality of the instrument are on-going. Based on previous work in system characterization we have focused on improved AO control. We present preliminary results and remaining challenges for a newly implemented Fourier transform reconstructor (FTR). The previously reported error budget analysis is also reviewed and updated, with consideration of how to improve both the amount of residual error and the robustness of the system. Careful characterization of the AO system will lead to improved performance and inform the design of future systems.