SEARCH · Engineering Papers
Results for “deconvolution”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Deconvoluting the benefits of porosity distribution in layered electrodes on the electrochemical performance of Li-ion batteries
Thick Lithium Ion Battery (LIB) electrodes suffer from poor rate capability and high ionic impedance due to their thickness and mesostructure. Therefore, optimizing thick electrode architectures becomes crucial. In this work, we report a systematic assessment of the ionic resistance in heterogeneous porous electrodes through the combination of computational simulations using a 4D-resolved model and experimental measurements. The first part of the study is devoted to a general assessment of Electrochemical Impedance Spectroscopy (EIS) spectra, mapping the impact of ionic and electronic resistances on the overall impedances of uncalendered and calendered LiNi 1/3 Mn 1/3 Co 1/3 O 2 , LiFePO 4 and graphite electrodes. In the second part, in silico-generated electrodes with different porosities are used in computational EIS simulations to analyze the impact of the electrode porosity on the ionic impedance. As expected, the results show that a lower porosity leads to a higher ionic impedance because of a higher electrode tortuosity factor. Furthermore, in silico-generated electrodes with different porosities were stacked and assembled to create heterogeneities of porosity along the thickness, and used in computational EIS and galvanostatic discharge simulations. The computational results show that the porosity heterogeneity along the electrode thickness has a significant effect on the ionic impedance and capacity of the electrode. The electrode architecture with progressively decreasing porosity from separator to current collector shows the highest performance, a trend validated by our in house experimental EIS and galvanostatic discharge also reported in this manuscript. Overall, we conclude that the ionic resistance in a thick electrode can be effectively reduced through proper tuning of the porosity heterogeneity. The proposed heterogeneous electrode architectures presented here could enormously help building efficient thick electrodes for LIBs.
Petrology of chromite in ureilites: Deconvolution of primary oxidation states and secondary reduction processes
Abstract not provided
Deconvolution of antibody affinities and concentrations by non-linear regression analysis of competitive ELISA data.
Physiological responses of the adaptive immune system are polyclonal in nature whether induced by a naturally occurring infection, by vaccination to prevent infection or, in the case of animals, by challenge with antigen to generate reagents of research or commercial significance. The composition of the polyclonal responses is distinct to each individual or animal and changes over time. Differences exist in the affinities of the constituents and their relative proportion of the responsive population. In addition, some of the antibodies bind to different sites on the antigen, whereas other pairs of antibodies are sterically restricted from concurrent interaction with the antigen. Even if generation of a monoclonal antibody is the ultimate goal of a project, the quality of the resulting reagent is ultimately related to the characteristics of the initial immune response. It is probably impossible to quantitatively parse the composition of a polyclonal response to antigen. However, molecular regression allows further parameterization of a polyclonal antiserum in the context of certain simplifying assumptions. The antiserum is described as consisting of two competing populations of high- and low-affinity and unknown relative proportions. This simple model allows the quantitative determination of representative affinities and proportions. These parameters may be of use in evaluating responses to vaccines, to evaluating continuity of antibody production whether in vaccine recipients or animals used for the production of antisera, or in optimizing selection of donors for the production of monoclonal antibodies.
Deconvoluting the Effect of Chromium and Aluminum on the Radiation Response of Wrought FeCrAl Alloys After Low-Dose Neutron Irradiation
FeCrAl alloys have been extensively investigated over the past decade as a candidate material for accident-tolerant fuel cladding in light water reactors. Here, we have completed a first of its kind study where Al and Cr concentrations are varied systematically under neutron irradiation to elucidate the post irradiation microstructural and mechanical response as a direct result of alloying content. Neutron irradiations were performed on alloys with composition Fe-(10-13)Cr-(5-7)Al in wt.% at temperatures of 214, 357, and 557°C to a dose of ~1.8 dpa (displacements per atom). Dislocation loop sizes and dispersion characteristics did not show strong compositional dependence. However, there were noticeable effects of composition on the dispersion of Cr-rich α'-precipitates, particularly a decrease in number density with increasing Al content or a decrease in Cr content. The present results confirm previous studies indicating the Cr concentration in these precipitates is lower than that expected in binary FeCr alloys and that Al can act as a destabilizing alloying element for the deleterious α'-phase.
Deconvoluting the impact of current collector structure and electrolyte selection on Coulombic efficiency of lithium metal anodes
Lithium metal batteries are regarded as a promising avenue for significantly boosting the gravimetric energy density of batteries, particularly for electric vehicles. However, the instability of the lithium metal anode continues to hinder performance. While 3D structured current collectors for lithium metal anodes have been frequently proposed as a solution, few studies explore the impact of these structures when combined with various electrolytes and the inclusion of a lithium reservoir within the structure. This study pairs four commercially available copper current collectors with four different electrolytes to assess how these factors influence cycling performance with a 4 mAh/cm2 lithium reservoir. Coulombic efficiency (CE) measurements revealed no statistically significant difference in CE across different current collectors within the same electrolyte. However, significant variations were noted when the current collector remained intact, and the electrolyte was changed. Although polarization, electrochemical impedance, and lithium morphology varied between structures and electrolytes, no consistent patterns emerged to suggest superior performance by any specific current collector structure. Therefore, the choice of structure appears inconsequential when a lithium reservoir is present, and efforts should focus on selecting and designing the electrolyte.
A variance deconvolution estimator for efficient uncertainty quantification in Monte Carlo radiation transport applications
Monte Carlo simulations are at the heart of many high-fidelity simulations and analyses for radiation transport systems. As is the case with any complex computational model, it is important to propagate sources of input uncertainty and characterize how they affect model output. Unfortunately, uncertainty quantification (UQ) is made difficult by the stochastic variability that Monte Carlo transport solvers introduce. The standard method to avoid corrupting the UQ statistics with the transport solver noise is to increase the number of particle histories, resulting in very high computational costs. In this contribution, we propose and analyze a sampling estimator based on the law of total variance to compute UQ variance even in the presence of residual noise from Monte Carlo transport calculations. Here, we rigorously derive the statistical properties of the new variance estimator, compare its performance to that of the standard method, and demonstrate its use on neutral particle transport model problems involving both attenuation and scattering physics. We illustrate, both analytically and numerically, the estimator’s statistical performance as a function of available computational budget and the distribution of that budget between UQ samples and particle histories. We show analytically and corroborate numerically that the new estimator is unbiased, unlike the standard approach, and is more accurate and precise than the standard estimator for the same computational budget.
Method for direct deconvolution of heat signals in transient adsorption calorimetry
Not Available
Improving spatio-temporal focusing and source reconstruction through deconvolution
Not Available
pyMS-Vis, an Open-Source Python Application for Visualizing and Investigating Deconvoluted Top-Down Mass Spectrometric Experiments: A Histone Proteoform Case Study
Not Available