Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dc”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A High Efficiency DC-DC Converter Topology Suitable for Distributed Large Commercial and Utility Scale PV Systems

In this paper a DC-DC power converter for distributed photovoltaic plant architectures is presented. The proposed converter has the advantages of simplicity, high efficiency, and low cost. High efficiency is achieved by having a portion of the input PV power directly fed forward to the output without being processed by the converter. The operation of this converter also allows for a simplified maximum power point tracker design using fewer measurements

14 SOLAR ENERGY↗

Coupled-inductor DC-DC power converter

A DC-to-DC power converter device has a common magnetic core structure that serves the functions of both transformer device and output inductor by integrating each into the common core. The transformer device has primary and secondary windings integrated into a first leg structure of the magnetic core, and the output inductor device has an output inductor winding integrated into a second leg structure of the magnetic core, the inductor winding structure for delivering output current to a load when a periodically switched input voltage is applied across the primary winding structure. The winding polarities of the transformer secondary winding structure and of the output inductor winding structure provide oppositely oriented polarities of electromotive force (EMF) to substantially reduce an output current ripple to an output load when delivering power through the transformer, through the output inductor and into the output load. A third leg structure of the common magnetic core allows magnetic flux passing through the transformer leg structure to partially magnetically couple to flux passing through the inductor leg structure, thereby allowing adjustment of the output voltage at which output current ripple is minimized.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Novel Decentralized PWM Interleaving Technique for Ripple Minimization in Series-Stacked DC-DC Converters: Preprint

Cascaded dc-dc converters are commonly used in applications where distributed energy sources or loads are connected to elevated voltage levels for power transfer. In such systems, it is advantageous to minimize the ripple on the bus current and voltage by proper phase shifting of the pulse-width modulation (PWM) pulses among the converters via a method known as interleaving. Existing approaches use either a centralized controller or separate communication lines among the stacked converters to control their relative PWM switch transitions. The key drawbacks are that these methods entail significant wiring, the central controller acts as a single point of failure, and implementation on very large numbers of units is impractical. In this paper, we introduce a decentralized interleaving control (DIC) strategy that acts on local current measurements at every converter and achieves communication-free PWM interleaving among the series-stacked converters. The proposed controller is simple in structure and is shown to converge asymptotically to the interleaved state irrespective of clock drifts among the digital signal processors. Experimental results are provided for a system of five series-connected converters showing a 10 times reduction in the current ripple compared to normal operation.

41 EE - Solar Energy Technologies Office (EE-4S)↗

An Intelligent System for Automatic Selection of DC-DC Converter Topology with Optimal Design

In this paper, we present an intelligent system that has the capabilities of automatically selecting topology classes and optimizing circuit parameters of DC-DC power converters for a given design specification. The system, Machine-Learning-enhanced Automated Circuit Configuration and Evaluation of Power Converters (ML-ACCEPT), uses a hybrid of machine learning technologies, decision tree inference, reinforcement learning and deep neural networks. The system gives high accurate recommendations of design topology classes and computationally efficient results in optimizing power efficiencies in power converter design.

Xue, Lincoln↗

Thermoelectric properties of DC-sputtered filled skutterudite thin film

The Yb filled CoSb{sub 3} skutterudite thermoelectric thin films were prepared by DC magnetron sputtering. The electrical conductivity, Seebeck coefficient, thermal conductivity, and figure of merit ZT of the samples are characterized in a temperature range of 300 K to 700 K. X-ray diffraction, scanning electron microscopy, and energy-dispersive X-ray spectroscopy are obtained to assess the phase composition and crystallinity of thin film samples at different heat treatment temperatures. Carrier concentrations and Hall mobilities are obtained from Hall Effect measurements, which provide further insight into the electrical conductivity and Seebeck coefficient mechanisms. The thermal conductivity of thin film filled skutterudite was found to be much less compared with bulk Yb filled CoSb{sub 3} skutterudite. In this work, the 1020 K heat treatment was adopted for thin film post process due to the high degree of crystallinity as well as avoiding reverse heating effect. Thin film samples of different thicknesses were prepared with the same sputtering deposition rate and maximum ZT of 0.48 was achieved at 700 K for the 130 nm thick sample. This value was between half and one third of the bulk figure of merit which was due to the lower Hall mobility.

36 MATERIALS SCIENCE↗

Crossed-beam DC slice imaging of fluorine atom reactions with linear alkanes

We report the reaction dynamics of F atom with selected alkanes studied by crossed beam scattering with DC slice ion imaging. The target alkanes are propane, n-butane, and n-pentane. The product alkyl radicals are probed by 157 nm single photon ionization following reaction at a collision energy of ∼10 kcal mol{sup −1}. The analyzed data are compared with the corresponding theoretical studies. Reduced translational energy distributions for each system show similar trends with little of the reaction exoergicity appearing in translation. However, the pentane reaction shows a somewhat smaller fraction of available energy in translation than the other two, suggesting greater energy channeled into pentyl internal degrees of freedom. The center-of-mass angular distributions all show backscattering as well as sharp forward scattering that decreases in relative intensity with the size of the molecule. Possible reasons for these trends are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrostatic design and conditioning of a triple point junction shield for a –200 kV DC high voltage photogun [Electrostatic design of a triple point junction shield for a -200 kV DC high voltage photogun using COMSOL]

Nuclear physics experiments performed at the Continuous Electron Beam Accelerator Facility (CEBAF) at the Jefferson Lab require a DC high voltage photogun to generate polarized electron beams from GaAs photocathodes. The photogun uses a tapered ceramic insulator that extends into the vacuum chamber and mechanically holds the cathode electrode. Increasing the operating voltage from nominal –130 kV to –200 kV will provide lower beam emittance, better transmission through injector apertures, and improved photocathode lifetime. This desire to increase the photogun operating voltage led to the design of a triple-point-junction shield electrode which minimizes the electric field at the delicate insulator-metal-vacuum interface and linearizes the potential across the insulator, thus reducing the risk of arcing along the ceramic insulator. Furthermore, this work describes the results obtained using COMSOL® electrostatic-field simulation software and presents the high voltage conditioning results of the upgraded –200 kV CEBAF photogun.

47 OTHER INSTRUMENTATION↗

Design of the Pacific DC Intertie Wide Area Damping Controller

This study describes the design and implementation of a proof-of-concept Pacific DC Intertie (PDCI) wide area damping controller and includes system test results on the North American Western Interconnection (WI). To damp inter-area oscillations, the controller modulates the power transfer of the PDCI, a ±500 kV DCtransmission line in the WI. The control system utilizes real-time phasor measurement unit feedback to construct a commanded power signal which is added to the scheduled power flow for the PDCI. After years of design, simulations, and development, this controller has been implemented in hardware and successfully tested in both open and closed-loop operation. The most important design specifications were safe, reliable performance, no degradation of any system modes in any circumstances, and improve damping to the controllable modes in the WI. The main finding is that the controller adds significant damping to the modes of the WI and does not adversely affect the system response in any of the test cases. The primary contribution of this paper, to the state of the art research, is the design methods and test results of the first North American real-time control system that uses wide area PMU feedback.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modelica Buildings Library Extension for AC and DC Building Comparison (Modelica DC Buildings) v1

This software simulates and compares the losses in AC and DC buildings. It uses formatted load profile data from EnergyPlus, PV generation data from PVWatts, realistic converter efficiency curves based on product data, a battery controller based on excess PV, and a realistic wire model. The software includes Modelica code, which is an extension of the Buildings Library Electrical models. It also includes Python code, which manages the Modelica parametric simulations and plots results.

Gerber, Daniel↗

A general unified approach to modelling switching dc-to-dc converters in discontinuous conduction mode

A method for modelling switching converters in the discontinuous conduction mode is developed, whose starting point is the unified state-space representation, and whose end result is a complete linear circuit model which correctly represents all essential features, namely, the input, output, and transfer properties (static dc as well as dynamic ac small signal). While the method is generally applicable to any switching converter operating in the discontinuous conduction mode, it is extensively illustrated for the three common power stages (buck, boost, and buck-boost). The results for these converters are then easily tabulated owing to the fixed equivalent circuit topology of their canonical circuit model.

Cuk, S.↗

Bidirectional dc-to-dc Power Converter

Solid-state, series-resonant converter uses high-voltage thyristors. Converter used either to convert high-voltage, low-current dc power to lowvoltage, high current power or reverse. Taking advantage of newly-available high-voltage thyristors to provide better reliability and efficiency than traditional converters that use vacuum tubes as power switches. New converter essentially maintenance free and provides greatly increased mean time between failures. Attractive in industrial applications whether or not bidirectional capability is required.

Griesbach, C. R.↗

A study of DC-DC converters with MCT's for arcjet power supplies

Many arcjet DC power supplies use PWM full bridge converters with large arrays of parallel FET's. This report investigates an alternative supply using a variable frequency series resonant converter with small arrays of parallel MCT's (metal oxide semiconductor controlled thyristors). The reasons for this approach are to: increase reliability by reducing the number of switching devices; and decrease the surface mounting area of the switching arrays. The variable frequency series resonant approach is used because the relatively slow switching speed of the MCT precludes the use of PWM. The 10 kW converter operated satisfactorily with an efficiency of over 91 percent. Test results indicate this efficiency could be increased further by additional optimization of the series resonant inductor.

Stuart, Thomas A.↗

Modular DC circuit breaker with integrated energy storage for future DC networks

A T-breaker is an all-in-one solution for dc microgrid fault protection, power flow control, and power quality improvement. A T-breaker features a modular multilevel “T” structure with integrated energy storage devices. The two horizontal arms of the T-breaker realize fault current breaking, load voltage compensation, and power flow control; and the vertical arm of the T-breaker realizes shunt compensation. The configuration provides excellent voltage scalability and relaxes the requirements on the switching signal synchronization during fault transients. The local energy storage in sub-modules eases the fault energy dissipation requirement placed on the traditionally-adopted surge arrestors. The modular multilevel structure also offers immense control flexibility for all types of targeted functions of the provided T-breaker.

Wang, Jin↗

S-Hybrid Step-Down DC-DC Converter-Analysis of Operation and Design Considerations

This paper presents a new highly integrable hybrid step-down converter that merges switched-inductor (SI) and switched-capacitor (SC) operations and significantly reduces onboard loss by using the input cable's parasitic inductance as its main inductor. This converter has the inductor placed at the input with a smaller voltage swing, leading to possible use of a smaller inductor and low-voltage rating switches that generally translate to reduced conduction losses. Analyses of converter operation and losses to reveal its original characteristics and design guidelines are presented to facilitate the components optimization. The converter architecture is verified by a proof-of-concept 15-W inductor-less lithium-ion battery charger prototype that uses a 1-m USB 3.0 cable as inductor. The converter, switched at 2 MHz from a 5-V input, experimentally achieves 89.7% peak efficiency and 6% higher efficiency at full load than a Buck converter counterpart. This high efficiency and zero onboard inductor yield a relative 45.7% onboard loss reduction at full load, promising excellent integration feasibility and superior system thermal management.

24 POWER TRANSMISSION AND DISTRIBUTION↗