Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cybersecurity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Internship Presentation: Integrating Safety and Cybersecurity: Security-by-Design with SOWT Analysis for Reactor Testing

This study covers leveraging reactor testing facilities that are primarily designed with a focus on safety to enhance cybersecurity testing. By incorporating reactor security-by-design with reactor safety-by-design principles and adopting defense-in-depth strategies that emphasize both safety and security, the research evaluates applicable cyber tools, models, and solutions. This includes simulating specific cyber-attack scenarios using reactor simulators and performing SWOT (Strengths, Weaknesses, Opportunities, Threats) analysis to improve the cybersecurity of reactor systems.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Work With Us to Advance Cybersecurity for the Current and Future Grid

The energy sector is undergoing rapid change. Advanced technologies and controls, digitally connected devices, and a mix of generation sources offer increased energy reliability and security, reduced energy costs, and enhanced grid operations. But they can also carry physical and cybersecurity risks that are not yet fully understood. With deep expertise in advanced energy technologies, the National Laboratory of the Rockies is examining the cybersecurity implications of evolving systems and developing cutting-edge tools, novel approaches, and innovative research capabilities to address sector-wide challenges. Together with our partners, we are working to achieve a more secure, defensible, and reliable grid.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cyber-Physical Power Systems Protection: The Byzantine Cybersecurity Framework

Cybersecurity of smart grids have been topic of much interest in recent years. As this critical infrastructure operation increases dependency on automated processes and controls, exposure to cyber-physical threats become inevitable. Considering cyber-physical security of the grid, much focus of attention has been made towards smart grids real-time monitoring solutions, including the state estimation process. Analyzing the relevant literature, one can note though that seldom research has been done on cyber-physical security of smart grids protection systems. Protection systems have intangible value towards grid reliability. This paper presents a cybersecurity framework for smart grids protection systems. A physics-based inspired machine learning solution is at the core process of the framework. Processed relay inputs and outputs are used by a deep predictive coding network. Formal models, a quasi-static state estimator, provides an oracle when low confidence decision is reached. Evolving knowledge is derived through reinforcement learning. Implementation aspects considering the Pacific Northwest National Laboratory Electricity Infrastructure Operations Center are presented. Built as an extra control layer to protection systems, without hard-to-derive parameters, highlights potential aspects towards real-life applications.

Bretas, Arturo Suman↗

Descriptive Analytics-Based Anomaly Detection for Cybersecure Load Forecasting

As power delivery systems evolve and become increasingly reliant on accurate forecasts, they will be more and more vulnerable to cybersecurity issues. A coordinated data attack by sophisticated adversaries can render existing data corrupt or outlier detection methods ineffective. This would have a very negative impact on operational decisions. The focus of this paper is to develop descriptive analytics-based methods for anomaly detection to protect the load forecasting process against cyberattacks to essential data. We propose an integrated solution (IS) and a hybrid implementation of IS (HIIS) that can detect and mitigate cyberattack induced long sequence anomalies. HIIS is also capable of improving true positive rates and reducing false positive rates significantly comparing with IS. The proposed HIIS can serve as an online cybersecure load forecasting scheme.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity for Distance Relay Protection

This project is a DOE follow-up effort on the CREDC workshop held on September 13, 2018 in Cambridge, MA to discuss cybersecurity of distance relays, which considered the benefits, vulnerabilities and risk mitigations for the use of communication systems in power system protection. The objectives of this project are to define the taxonomy of relay protection and associated communications; define use cases describing approaches to reduce the cyber-attack surface on those protective relays; and evaluate the loss of operational functional capability from changes to communication coverage. Mitigating controls will also be evaluated to understand if there are other approaches to reduce attack surfaces while maintaining communications or partial communications. Distance relays are used to protect transmission lines of approximately 10 to 300 miles in length, by detecting short circuits (i.e., faults) on the lines and then tripping circuit breakers in the substation. Such protection systems are a subset of the power system and they incorporate sensing, logic and communication functions. Protection system exposure to cyberattack could be drastically limited by disconnecting relays from all vulnerable communication systems, but this may adversely impact overall power system performance in the absence of cyberattack. This project began with a use case analysis of protection systems with communications, as summarized in this report. It continued with modeling, testing and evaluation in a miniature power system (MPS), located in the Western Area Power Administration (WAPA) Electric Power Training Center (EPTC). The project also incorporated feedback from two industry meetings held in February and September 2019. The suggested next steps account for and complement the work already underway with DOE/CESER funding: 1. Study the performance of LCD and PC vs. PUTT, which is less reliant on communication system performance and GPS timing references. The PUTT scheme could prove to be more resilient to cyberattack or communications-related disruption. It could also be more tolerant of message re-routing with SDN/SDR communication systems. On the other hand, it will be more vulnerable to false tripping during dynamic events or to loss of the voltage signal. The optimum choice of scheme may depend on the specific power system and risk assessment. This study could provide a new template for evaluation based on business functions. 2. Research and develop new methods to detect and monitor distributed physical attacks, possibly using drones, video sensors, thermal sensors, machine learning and other advanced techniques. This will help mitigate the impact of cyberattack on the protection system, and will also help mitigate the impact of wild fires. 3. Implement a scalable PKI for use in electric utility protection systems. This will encourage widespread adoption of secure authentication methods that are already available, but not widely used at present. This will help secure engineering access to the relays. 4. Investigate the use of SDN in combination with SDR to achieve better cybersecurity and electromagnetic security of the network, incorporating path variability. This would help secure both engineering access and peer-to-peer GOOSE messaging. 5. Perform additional testing, with operator evaluation of “red button” scenarios, PUTT vs. LCD, relay mis-operations, and other cyberattacks in the EPTC. This is an important advantage of testing in the EPTC rather than by computer simulation or even hardware-in-the-loop simulation; the EPTC is already dedicated to managing the situational awareness, operator response times and other human impacts. One of the project objectives was to settle on a common nomenclature for this problem space. We have concluded that the OSI layer model, supplemented by ANSI device numbers and other IEEE standards, is already well-accepted by the industry. The IEEE PSRC knowledge base provides a great deal of public information

24 POWER TRANSMISSION AND DISTRIBUTION↗

New Mexico Cybersecurity Center Institute 2020 Experience

The New Mexico Cybersecurity Center 2020 Summer Institute with Sandia National Laboratories was the rst ever for the New Mexico Cybersecurity Centers. Due to the occurrence of the COVID-19 global pandemic during the summer of 2020 some unforeseen challenges had to be faced in running the institute, such as the fact that all students had to work remotely. This document details the students involved in the institute and their contributions to Sandia projects over the summer of 2020, as well as an analysis on how to successfully run a summer institute via distance.

97 MATHEMATICS AND COMPUTING↗

NNSA Minority Serving Institute Partnership Program (MSIPP)--Indigenous Mutual Partnership to Advanced Cybersecurity Technology (ASPIRE, IMPACT and PAMER); FY22 Q2 Progress Report

The following report summarizes the status update during this quarter for the National Nuclear Security Agency (NNSA) initiated Minority Serving Institution Partnership Plan's (MSIPP) projects titled, Indigenous Mutual Partnership to Advanced Cybersecurity Technology (ASPIRE), Indigenous Mutual Partnership to Advanced Cybersecurity Technology (IMPACT) and Partnership for Advanced Manufacturing Education and Research (PAMER).

42 ENGINEERING↗

Cybersecurity for the Operational Technology Environment (CyOTE) (Final Technical Report)

Electric grids have historically been susceptible to both physical attacks and environmental hazards but the implementation of smart grids, remote management, and self-healing networks, has now made the grid vulnerable to cyber attacks. To address risks introduced by routable connectivity, utilities must establish dynamic solutions to identify, protect, detect, respond to, and recover from cyber security threats and vulnerabilities. In response to the evolving threat landscape U.S. Department of Energy-Office of Cybersecurity, Energy Security, and Emergency Response (DOE CESER) initiated the Cybersecurity for the OT Environment (CyOTE) pilot program, a U.S. Department of Energy (DOE) effort designed to leverage U.S. intelligence capabilities to prevent, detect, or mitigate a cyber attack on utility operational technology (OT) networks. As part of the CyOTE pilot, The Southern Company (Southern Company or Southern) researched, evaluated and deployed emerging Commercial off the Shelf (COTS) technologies and cyber security monitoring architectures to provide previously unrealized network visibility and situational awareness through deep packet inspection and data analytics. This Final Scientific/Technical Report documents the objectives, methodology, lessons learned, and results of Southern Company’s participation in the CyOTE pilot from December 2018 to September 2023.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DEReliction: A Cybersecurity Vulnerability Assessment Methodology for Distributed Energy Resources

With the increasing integration of Distributed Energy Resources (DER) into the electric grid, maintaining grid reliability and resilience requires that these devices remain secure. This paper discusses a cybersecurity vulnerability assessment methodology that incorporates best practices from Sandia National Laboratories, SANS Institute, OWASP Foundation, and other web and Internet of Things (IoT) penetration testing (“pen testing”) programs, courses, and frameworks for assessing the security posture of devices. The methodology involves five sequential steps: (1) Collect Public Information, (2) Extract Hardware Details, (3) Inventory Software Components, (4) Identify Vulnerabilities, and (5) Test Vulnerabilities. Each step uncovers potential weaknesses in both hardware and software components of DER devices, considering adversary tactics, techniques, and procedures (TTPs), and potential attack vectors along the way. The results from the execution of this method on multiple residential- and small commercial-scale photovoltaic (PV) inverters reveled hardware and software vulnerabilities, which highlight the benefit of taking a methodical approach to discover vulnerabilities. While the specific vulnerability details are not shared here, a generalized overview of findings underscore the importance of robust security assessments for DER devices. Adoption of an assessment framework of this kind will identify and mitigate cybersecurity threats and bolster the resilience of DER-integrated electric grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Defensive Cybersecurity Architecture Design Using Force-on-Force Cyber-Physical Modeling

Currently, nuclear power plant physical security systems are highly dependent on air-gaps as a protective measure against cyber-threats. Cyber-physical threats become more likely as advanced cyber-threat capabilities to jump air-gaps transition into common use. Defending against the emerging threat of cyber-enabled physical intrusions is poorly understood. The consequence of these cyber-physical attacks has no quantitative analysis method to inform risk-informed, performance-based cybersecurity approaches. By modifying the physical security simulation tool Dante, cyber-physical threat consequence was able to be analyzed on a notional facility. The results of this analysis are used to design a Defensive Cybersecurity Architecture (DCSA) for the physical security system to produce example resilience measures for this notional facility. A DCSA defines security levels to provide a graded approach for defending plant functions, and security zones for trusted communication between systems. This approach can be applied to real world systems to produce physical protection systems and response measures that are resilient to cyber-physical threats.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Cybersecurity Plan Review Summary: For Connected Communities

As part of the Connected Communities (CC) Technical Assistance Program led by Lawrence Berkeley National Laboratory (LBNL), Pacific Northwest National Laboratory (PNNL) oversees the cybersecurity technical assistance for the CC cohort. PNNL’s role is to provide a combination of provision of resources and technical assistance to support the development of successful cybersecurity plans for the Connected Communities cohort. This report is an update for June 2023 on the current status of plans reviewed to date.

97 MATHEMATICS AND COMPUTING↗

Cybersecurity Center for Offshore Wind Energy (Final Project Report)

This project establishes a Cybersecurity Center for Offshore Wind Energy with the objective of designing and operating a cyber-physical testbed for wind energy farms (WEFs) that enables comprehensive cybersecurity research. The testbed incorporates a Supervisory Control and Data Acquisition (SCADA) system connected to turbine models via industrial-grade programmable logic controllers (PLCs) and remote terminal units (RTUs). It supports side-channel data acquisition, implementation and analysis of various cyberattack scenarios, and development of attack detection, mitigation, and best-practice guidance tailored to wind energy systems. During the project, the team expanded the number and fidelity of mathematical turbine models (MTMs), integrated these models with SCADA infrastructure, and deployed a scaled physical turbine and associated sensors. High-resolution operational and side-channel data streams were collected and used to refine machine-learning (ML)-based attack detection systems and to extend the WindCRAFT framework to multi-turbine threat scenarios. The project demonstrated a realistic, scalable environment for evaluating cyber threats, validated attack detection approaches using enriched datasets, and identified new multi-turbine and inter-turbine communication attack vectors. The resulting testbed, models, and security mechanisms provide a foundation for ongoing R&D and deployment of cyber-resilient offshore wind energy systems.

17 WIND ENERGY↗

Verification and Validation of Performance with Dissemination of Best Practices in District Energy and CHP for Enhanced Resiliency, Energy Efficiency, and Cybersecurity

This report contains the results of the International District Energy Association’s work to analyze, validate, and verify performance data of existing district energy systems and identify industy best practices for the purpose of improving system reliability, resiliency, and efficiency, and to accellerate decarbonization. In addition to a technical evaluation of the surveyed systems and identification of a series of technical performance metrics, the report illustrates the accompanying operations and financial best practices employed by surveyed systems to fully serve their customer base. Additionally, the third chapter of the report describes the current landscape of cybersecurity threats and counteracting measures, and recommends a series of steps for effectively guarding highly networked district energy systems against cybersecurity attacks.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Cybersecurity Workforce Training for SMR Integration into Distribution Grids: A Competency Framework and Containerized Hands-On Lab for the SMR/DER/Microgrid Boundary

Small modular reactors (SMRs) and microreactors are entering the U.S. distribution grid as synchronous generation on feeders designed for loads and inverter-based distributed energy resources (DERs). No existing cybersecurity training program addresses this intersection of nuclear operations, DER management, and operational technology security. As subcontractor to Iowa State University on the CyDERMS Center, Argonne analyzed the relevant standards and training landscape, translated the resulting gaps into a twelve-objective competency framework across distribution-operator and graduate-analyst role tracks, and built a containerized training lab using a ∼400-bus composite grid model behind a realistically simulated Modbus TCP SCADA stack. The analysis isolates the balance-of-plant / energy-management-system (BOP/EMS) boundary as the critical jurisdictional seam where, as of March 2026, neither NRC nor NERC CIP cleanly claims cybersecurity responsibility for distribution-connected SMRs. The framework maps each objective across NIST CSF 2.0, ISA/IEC 62443, NIST NICE Task–Knowledge–Skill statements, and NRC RG 5.71 awareness-and-training controls. The training lab implements operator-recognition assessment scenarios spanning grid-side disturbances and telemetry-layer anomalies.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Data Center Cybersecurity, Supply Chain Risk Management, and Emerging Regulation Cohort Summary: Takeaways and Action Plans

This report summarizes the outcomes of the Data Center Cohort under the Department of Energy’s Technical Assistance for Digital Assurance (TADA) initiative, aimed at enhancing grid resilience through cybersecurity, supply chain risk management (SCRM), and Cyber-Informed Engineering (CIE). The cohort engaged 17 organizations across utilities, data center operators, vendors, and technology providers in three sessions combining presentations, discussions, and exercises. Key topics included AI-driven load behavior, cybersecurity vulnerabilities in UPS/BESS and cooling systems, governance gaps at utility–data center boundaries, and supply chain integrity. Five cross-cutting themes emerged: interconnection architecture vulnerabilities, fragmented governance, AI-driven stability risks, lack of regulatory frameworks, and long-term supply chain concerns. Actionable recommendations were developed, including implementing DMZ segmentation, formalizing vendor access agreements, designing AI workload limits, and advancing standards through NERC and state-level programs. These strategies aim to strengthen resilience, clarify responsibilities, and ensure secure integration of data centers into the grid.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

An Accuracy-Maximization Approach for Claims Classifiers in Document Content Analytics for Cybersecurity

This paper presents our research approach and findings towards maximizing the accuracy of our classifier of feature claims for cybersecurity literature analytics, and introduces the resulting model ClaimsBERT. Its architecture, after extensive evaluations of different approaches, introduces a feature map concatenated with a Bidirectional Encoder Representation from Transformers (BERT) model. We discuss deployment of this new concept and the research insights that resulted in the selection of Convolution Neural Networks for its feature mapping aspects. We also present our results showing ClaimsBERT to outperform all other evaluated approaches. This new claims classifier represents an essential processing stage within our vetting framework aiming to improve the cybersecurity of industrial control systems (ICS). Furthermore, in order to maximize the accuracy of our new ClaimsBERT classifier, we propose an approach for optimal architecture selection and determination of optimized hyperparameters, in particular the best learning rate, number of convolutions, filter sizes, activation function, the number of dense layers, as well as the number of neurons and the drop-out rate for each layer. Fine-tuning these hyperparameters within our model led to an increase in classification accuracy from 76% obtained with BertForSequenceClassification’s original model to a 97% accuracy obtained with ClaimsBERT.

Ameri, Kimia (ORCID:0000000328791871)↗

OPERATIONAL TECHNOLOGY BEHAVIORAL ANALYTICS (OTBA) – A DATA-CENTRIC APPROACH FOR REDUCING CYBERSECURITY RISK

This paper provides a summary of the methodology, findings, lessons learned, and insights from an investigation into the feasibility of the Operational Technology Behavioral Analytics (OTBA) cybersecurity approach. The concept was evaluated with data from the National Carbon Capture Center (NCCC) – a U.S. Department of Energy (DOE) funded facility that is managed and operated by Southern Company at Alabama Power’s E. C. Gaston generating power plant in Wilsonville, Alabama. Appropriate data sources for the post-combustion carbon capture system were identified. Infrastructure was deployed to monitor, capture and archive data for the system. Critical parameters for each subsystem were identified and analyzed. Machine-learning algorithms were used to establish and characterize normal operations and subsequently identify anomalies. This effort yielded valuable insights and formed the basis of a data-centric strategy for detecting cyber-attacks along with a coordinated response philosophy. A significant takeaway is that the OTBA cybersecurity approach is quite portable; it can be applied to other critical infrastructure beyond fossil power generation.

Black, Clifton↗

HP in Cybersecurity: CyOTE

The U.S. Department of Energy’s (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER), through the Cybersecurity for the Operational Technology Environment (CyOTE) Program, worked with energy sector asset owners and operators (AOOs), partners, and Idaho National Laboratory (INL) to develop capabilities for AOOs to independently detect adversarial tactics, techniques, and procedures (TTPs) within their operational technology (OT) environments. Unlike the approach taken with commercial security solutions, CyOTE seeks to tie anomalies in cyber operations to a cyber-attack. By stringing together multiple techniques in the OT environment, AOOs can identify attack campaigns with ever decreasing impacts. The CyOTE methodology applies fundamental concepts of perception and comprehension to a universe of knowns and unknowns increasingly disaggregated into observables, anomalies, and triggering events. MITRE’s ATT&CK® Framework for Industrial Control Systems (ICS) is used as a common lexicon to identify a set of triggering events related to three Use Cases – Alarm Logs, Human-Machine Interface (HMI), and Remote Logins – which together account for 87 percent of the techniques commonly used by adversaries. The CyOTE methodology is also appropriate for OT-related anomalies perceived outside the three Use Cases, such as through the energy system itself.

99 GENERAL AND MISCELLANEOUS↗