Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenic system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Technical Assessment of Off-Gas System Technologies for Potential Use in Molten Salt Reactors

Molten salt reactors (MSRs) are a class of Generation IV advanced reactor technologies aimed to enhance and improve the safety, fuel utilization and cost-effectiveness of nuclear power generation. MSR concepts are based on using a molten salt mixture as a primary nuclear reactor coolant, while the fuel can be either directly dissolved in the coolant (i.e., fluid-fueled) or can be in a separate solid form (i.e., salt-cooled solid-fueled). MSRs can be operated in either thermal or fast neutron spectra, as simple fissile convertors, or breeder reactors (e.g., utilizing both fissile and fertile fuels), as well as accelerator-driven sub-critical reactors or transuranic element burners. Operation of MSRs will necessitate management and treatment of the off-gas streams released to the headspace of the reactor where, in some designs, a cover gas can be circulated to remove certain fission products and maintain an inert atmosphere. An inert MSR cover gas swept over or sparged into the salt will confine radionuclides emerging from the free surface, including radioactive noble and non-noble gases, aerosols, and volatile species. The elements and compounds of these species will have a wide range of thermochemical and physical properties, some of which will decay to different products in the off-gas stream. Therefore, system components used to manage and treat MSR off-gas streams will need to be robust under dynamic reactor and chemistry conditions to support adequate reactor performance by managing the composition and species in the salt coolant and cover gas space. Off-gas system components would perform as a radionuclide boundary to the reactor vessel and a primary means for preventing radionuclide release; therefore, they are of high safety significance for MSR operations. This report reviews various technologies and materials for potential implementation in the design of an MSR off-gas system per a general conceptual framework. The reviewed technologies operate based on scrubbing, capture, delay, or separation of species in the off-gas stream. These include molten hydroxide scrubbers, solid sorbents, delay off-gas systems, particle traps, and cryogenic distillation. Since aspects of an off-gas system will be design-specific, the approach is to provide general discussions on attributes of these technologies and materials, including target off-gas stream species, operational parameters and conditions of importance to decontamination factors, implementation maturity, system component monitoring, potential off-normal conditions and considerations for waste products. The information aims to support the U.S. Nuclear Regulatory Commission in their safety evaluations for MSR designs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Bandwidth and Aliasing in the Microwave SQUID Multiplexer

The microwave SQUID multiplexer (μmux) has enabled higher bandwidth or higher channel counts across a wide range of experiments in particle physics, astronomy, and spectroscopy. The large multiplexing factor coupled with recent commercial availability of microwave components and warm electronics readout systems make it an attractive candidate for systems requiring large cryogenic detector counts. Since the multiplexer is considered for both bolometric and calorimetric applications across several orders of magnitude of signal frequencies, understanding the bandwidth of the device and its interaction with readout electronics is key to appropriately designing and engineering systems. Here we discuss several important factors contributing to the bandwidth properties of μmux systems, including the intrinsic device bandwidth, interactions with warm electronics readout systems, and aliasing. Further, we present simulations and measurements of μmux devices coupled with SLAC Microresonator RF (SMuRF) tone-tracking electronics and discuss several implications for future experimental design.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fermilab’s horizontal test stand upgrade overview and commissioning

Cryo-assemblies with the low-beta Nb3Sn quadrupoles for the High Luminosity LHC (HL-LHC) upgrade will be tested at Fermilab’s magnet test facility. Total of 10 cryo-assemblies will be delivered to CERN within the US HL-LHC Accelerator Upgrade Project (AUP). The horizontal test stand at Fermilab already has been used for testing the existing LHC inner-triplet quadrupoles, but the stand and corresponding electrical and cryogenic sub-systems were not operational more than a decade. In order to restore the test stand functions and meet the design and test requirements for the high luminosity LHC magnets, the existing horizontal test facility at Fermilab underwent a significant refurbishment of the cryogenic and mechanical components. Most of the upgrades were completed and verified during so called zero-magnet test by late 2020, and then final commissioning of the upgraded test stand was completed during the first cryo-assembly test in 2023. These tests verified all the cryo-mechanical installations, as well as the test stand operations, including controlled cooldown and operation at 1.9 K, the helium recovery capabilities, magnet protection and process controls.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fermilab's Horizontal Test Stand Upgrade Overview and Commissioning

Cryo-assemblies with the Nb 3 Sn MQXFA low-beta quadrupoles for the High Luminosity LHC (HL-LHC) upgrade will be tested at Fermilab's magnet test facility. A total of 10 cryo-assemblies will be delivered to CERN within the US HL-LHC Accelerator Upgrade Project (AUP). The horizontal test stand at Fermilab already has been used for testing the existing LHC inner-triplet quadrupoles, but the stand and corresponding electrical and cryogenic sub-systems were not operational for more than a decade. In order to restore the test stand functions and meet the design and test requirements for the HL-LHC magnets, the existing horizontal test facility at Fermilab underwent a significant refurbishment of the cryogenic and mechanical components. Most of the upgrades were completed and verified during so called zero-magnet test by late 2020, and then final commissioning of the upgraded horizontal test stand was completed during the first cryo-assembly test in 2023. These tests verified the major cryo-mechanical installations, as well as the basic test stand operations, including controlled cooldown and operation at 1.9 K, magnet protection and process controls. Here, in this paper, overview of the Fermilab's horizontal test facility upgrade and commissioning of these upgrades are presented.

43 PARTICLE ACCELERATORS↗

High resolution diagnostic tools for superconducting radio frequency cavities

Superconducting radio-frequency (SRF) cavities are one of the fundamental building blocks of modern particle accelerators. To achieve the highest quality factors (10 10 –10 11 ), SRF cavities are operated at liquid helium temperatures. Magnetic flux trapped on the surface of SRF cavities during cool-down below the critical temperature is one of the leading sources of residual RF losses. Instruments capable of detecting the distribution of trapped flux on the cavity surface are in high demand in order to better understand its relation to the cavity material, surface treatments and environmental conditions. We have designed, developed, and commissioned two high-resolution diagnostic tools to measure the distribution of trapped flux at the surface of SRF cavities. One is a magnetic field scanning system, which uses cryogenic Hall probes and anisotropic magnetoresistance sensors that fit the contour of a 1.3 GHz cavity. This setup has a spatial resolution of ~ 13 μm in the azimuthal direction and ~ 1 cm along the cavity contour. The second setup is a stationary, combined magnetic and temperature mapping system, which uses anisotropic magnetoresistance sensors and carbon resistor temperature sensors, covering the surface of a 3 GHz SRF cavity. This system has a spatial resolution of 5 mm close to the iris and 11 mm at the equator. Initial results show a non-uniform distribution of trapped flux on the cavities’ surfaces, dependent on the magnitude of the applied magnetic field during field-cooling below the critical temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Pilot Testing of a Modular Oxygen Production System Using Oxygen Binding Adsorbents (Final Report)

In this project, RTI and Air Liquide have focused on the development of innovative oxygen separation materials and technologies based on reversibly binding of oxygen to enable smaller and cheaper air separations. In alignment with that object the team has had multiple achievements to advance the technology including: Synthesized and characterized novel M-CoSalen (RTIO2Sorb-1) material which showed a dynamic oxygen adsorption capacity in excess of 1wt%. Developed synthesis routes for RTIO2Sorb-1 with commercially relevant techniques and produced batches of 0.25kg and over 4 kg of total synthesis. Synthesized and characterized extrudate forms of the RTIO2Sorb-1 with relevant crush strength and maintained dynamic oxygen adsorption capacity in near 1wt%. Developed techniques for forming structured beds in fiber shapes with conventional materials. Developed a model for O 2 sorption processes to analyze various bed configurations and cycle parameters. Studied classic O 2 solid sorbents reported in the literature to learn oxygen binding mechanisms. Design a 10 kg/day O 2 VPSA pilot system with 2 or 4-bed operation. Completed a techno-economic analysis based on the experimental results and modeling. The overall objective of the project was to design, fabricate, and test a modular O 2 production system and perform a techno-economic analysis (TEA) after testing to determine the cost-benefit of the advanced modular air separation system. The goals of this technology development project were to achieve a bed-size factor (BSF) of less than 600 lb-adsorbent/TPD O 2 (ton/day O 2 ) (as compared with the state-of-the-art BSF of 850), and O 2 -purity greater than 95% at a cost that is projected to be equivalent or lower than the current state of the art (SOTA), commercially available large-scale cryogenic air separation systems. To achieve these goals and objective, the project team executed on (1) oxygen binding adsorbent optimization and scale up, (2) adsorbent material formation process studies to form the adsorbent material into structured beds for rapid pressure swing adsorption (PSA) cycles with low pressure drop, fast mass transfer, and low attrition, (3) cycle development studies to optimize the PSA process, and (4) develop simulation tools for rapid cycle modeling and numerical evaluation/optimization.

20 FOSSIL-FUELED POWER PLANTS↗

Broadband optical modulation and control at millikelvin temperatures

A universal experimental challenge in studying radiation effects on cryogenic devices is precisely and accurately characterizing the position-dependent device response near the energy detection threshold. Here, we have developed a compact cryogenic optical beam steering system that can be used to generate O (μs) pulses of small numbers of photons over the energy range of 1.3–3.4 eV at room temperature, and deliver those photons via fiber optic to any specified location on the surface of a detector operating at cryogenic temperatures. This new system will allow for robust calibration of any photon-sensitive detector, including superconducting devices. The system can be used efficiently to explore the physics of target materials, quantify the position sensitivity of different sensor designs, measure phonon transport, and study the effects of quasiparticle poisoning on detector operation. We describe the design of this pulsed calibration method and present first results obtained with a second-generation system operated at room temperature and sub-Kelvin temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EMC Effect of Tritium and Helium-3 from the JLab MARATHON Experiment

Measurements of the EMC effect in the tritium and helium-3 mirror nuclei are reported. The data were obtained by the MARATHON Jefferson Lab experiment, which performed deep inelastic electron scattering from deuterium and the three-body nuclei, using a cryogenic gas target system and the high resolution spectrometers of the Hall A Facility of the Lab. The data cover the Bjorken 𝑥 range from 0.20 to 0.83, corresponding to a squared four-momentum transfer 𝑄 2 range from 2.7 to 11.9 (GeV/𝑐) 2 , and to an invariant mass 𝑊 of the final hadronic state greater than 1.84 GeV/𝑐 2 . The tritium EMC effect measurement is the first of its kind. The MARATHON experimental results are compared to results from previous measurements by DESY-HERMES and JLab–Hall C experiments, as well as with few-body theoretical predictions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Record High Ramping Rates in HTS Based Superconducting Accelerator Magnet

Here we report results of experimental test of the High Temperature Superconductor (HTS) based fast-cycling prototype accelerator magnet capable to operate up to about 300 T/s field ramping rate with some 0.5 T B-field in the magnet gap. The measured upper limit for the cryogenic cooling power required to support magnet conductor operation at high ramping rates indicates great potential for such type of magnets in rapid cycling synchrotrons for neutrino research or acceleration of very short-lived muons. The test magnet design, construction and supporting cryogenic and power systems are briefly described. The magnet's power test results are discussed in terms of a possible upgrade of this magnet design to 2 T B-field, a maximum feasible with super-ferric magnet.

43 PARTICLE ACCELERATORS↗

Long-term stability-degradation analysis of DUNE SiPMs in Liquid Nitrogen

We developed a cryogenic photon readout system to monitor arrays of DUNE SiPMs operating at various over-voltages in liquid nitrogen (LN2) for over three months. Photoelectron signals were read out simultaneously via weak capacitive coupling to the micro-FEMB, a 32-channel charge sensitive readout board designed for 77 K to 300 K operation in liquid argon time projection chambers (LAr-TPCs). A waveform snippet acquisition scheme was implemented to capture waveform signals whenever they exceeded a predetermined trigger level; consequently, empty waveforms were discarded. Selected SiPM parameters were monitored to detect any deviations beyond statistical fluctuations. While some parameters exhibited ~1σ variations over the 3-month test period, there was no evidence of drift being enhanced when operating at 4 V or 5 V compared to a 3 V over-voltage. However, a discernible PDE drop was observed across all channels, which warrants further investigation. In addition, we demonstrated that our system can simultaneously read out single photons from a selected group of SiPMs at room temperature.

Tsang, Thomas [Brookhaven]↗

Effect of interfacial structures on phonon transport across atomically precise Si/Al heterojunctions

Phonons are important carriers of energy and information in many cryogenic devices used for quantum information science and in fundamental physics experiments such as dark matter detectors. In these systems phonon behavior can be dominated by interfaces, hence there is increasing demand for a more detailed understanding of interfacial phonon transport in relevant material systems. Previous studies have focused on understanding thermal transport over the entire phonon spectrum at and above room temperature. At ultra-low temperatures, however, knowledge is missing regarding athermal phonon behavior due to the challenge in modeling the extreme conditions in micro-scale, heterogeneous cryogenic systems, as well as extracting single-phonon information from a large ensemble. In this work, we delineate interfacial phonon transport using a combination of classical molecular dynamics (MD) and phonon wave packet simulations, to illustrate the consistency and differences between the ensemble- and single-phonon dynamics. We consider three single-crystal Si surface reconstructions --- (1×1), (v3×v3) and (7×7) --- and model both experimentally observed Si(1×1)/Al interfaces and hypothesized Si(v3×v3)/Al and Si(7×7)/Al interfaces. The overall interfacial thermal conductance calculated from non-equilibrium MD shows that for the Si(1×1)/Al system, the presence of Al twin grain boundaries can hinder phonon transport and reduce thermal conductance by 2--12% relative to single-crystal Al; whereas the Si (v3×v3) and (7×7) reconstructions can enhance it by 6--19%. Normal mode decomposition reveals that both the increase and decrease in conductance are related to inelastic phonon scattering. Single-phonon wave packet simulations show results consistent with NEMD, while further suggesting that phonon polarization conversion is significant even when elastic transmission dominates, and that the interfacial structures have anisotropic impacts on atomic vibrations along different lattice directions. Our findings suggest alternative perspectives in achieving selective phonon transport through controlling interfacial structures of materials with atomically-precise fabrication techniques, and that the phonon wave packet formalism is a potentially powerful method for developing a detailed understanding of non-equilibrium phenomena in the low-temperature limit.

Lu, Zexi↗

An automated system to define the optimal operating settings of cryogenic calorimeters

Cryogenic macro-calorimeters instrumented with NTD thermistors have been developed for several decades. The choice of the optimal bias current is crucial for a proper operation of these detectors, both in terms of energy resolution and stability. In this paper we present a set of automatic measurements and analysis procedures for the characterization and optimization of the working configuration of the NTD thermistors. The presented procedures were developed for CUORE, an array of 988 cryogenic macro-calorimeters instrumented with NTD thermistors that has been taking data since 2017. These procedures made it possible to characterize a large number of detectors in a reliable way. They are suitable enough to be used also in other large arrays of cryogenic detectors, such as CUPID.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Validation of a Cryogenic Dilatometer

This project focuses on the design and development of a cryogenic dilatometer capable of measuring the thermal expansion of materials at extremely low temperatures. Understanding how materials change dimension with temperature is critical for applications involving cryogenic environments, particularly laminated systems housing superconducting magnets, where small dimensional changes can significantly affect performance and reliability. To address this, a dilatometer system was designed to operate within a liquid nitrogen environment while accurately measuring displacements caused by thermal contraction. The purpose of this device is to determine the coefficient of thermal expansion (CTE) of a material. The design process involved defining functional requirements, developing mechanical and thermal concepts for the measurement apparatus, selecting appropriate materials compatible with cryogenic temperatures, and integrating sensors capable of detecting small dimensional changes. The resulting system aims to provide a practical and repeatable method for evaluating material thermal expansion at cryogenic temperatures, supporting research into composite use in superconducting applications that require accurate characterization of material behavior in low-temperature environments.

Schmitt, Nicholas [Northern Illinois U.]↗

Expandable systems for space

Systems for insulating a space vehicle or space borne container from an external environment as well as cryogens from heat sources. Such systems also protect the vehicle from the high dynamic pressures, the high heat loads encountered in atmospheric flight, and provide storage capability that strongly limits, or effectively eliminates, cryogenic boil-off losses once in space. Such systems include an expandable structure having a plurality of contiguously adjacent expandable layers. The layers are connected by a plurality of tension connectors between successive layers. For launch and flight the layers can be restrained in a collapsed position. Whereupon exiting a free stream environment, the layers are expanded where they can lock into place or otherwise remain in an expanded state. The expansion creates separation between the layers with minimal conduction paths providing near theoretically perfect multi-layer insulation and extremely effective debris protection.

de Jong, Maxim↗

Cryogenic Control Circuitry for Superconducting Qubits

Superconducting qubits have reached the point where system designers are worried about the heat that control wiring brings into the cryostat. To continue scaling cryogenic quantum systems, control solutions that work inside the cold space must be explored. One possibility is to use control electronics that is native to superconductivity, so called single-flux-quantum (SFQ) circuitry, to form an interface between qubits and whatever other electronics is needed to control eventual quantum systems. To begin exploring the utility of SFQ as control circuitry, we performed modeling and experiments on qubit readout using ballistic fluxons which are SFQ in the limit of ballistic fluxon transport. Our modeling results show that a flavor of qubit, the fluxonium, can be read out using ballistic fluxons. We designed test samples to prove some of the key concepts needed for such a readout but were ultimately unable to getting a working demonstration. The lack of testing success was due to challenges in fabrication and running short of time to perform testing rather than a fundamental problem with our analysis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

National Ignition Facility. Facility and Infrastructure Systems Maintenance Plan

Ensuring the reliability of the NIF, including its support systems, laser systems, target diagnostic systems, and utilities, is essential to the availability of the NIF in its support of NNSA missions. NIF is a key capability in the DOE Stockpile Stewardship Program and supports high energy physics experiments for nuclear weapons, energy, and astrophysics applications. High system reliability provides opportunities for shots and scientific discoveries with opportunities to enhance and upgrade capabilities. This Maintenance Plan (MP) identifies the policies and procedures used to perform and support asset management of the NIF Facility and Infrastructure Systems (FInS), NIF Lasers & Alignment (LASE), NIF Target Experimental Operations (TOPS), NIF Target Area Science and Engineering (TASE), and NIF&PS Control Systems (NCS). The FInS systems include the facility, HVAC, contamination control, beampath, and Line Replaceable Units (LRUs) as well as utilities which create the beampath environments, such as vacuum, argon, or clean dry air. The LASE systems are Programmatic systems which include laser diagnostics, alignment, power conditioning, pulsed power, and input laser systems. The TOPS and TASE systems are also Programmatic systems which include target and diagnostic delivery systems and positioners, many different insertable and fixed target diagnostics, and cryogenic and target gas fill systems. Finally, the NCS systems include both software and hardware for industrial and shot operation control systems. Policies governing administrative and operational practices related to maintenance of FInS, LASE, TOPS, TASE, and NCS systems are described in this plan. In addition, the plan provides processes and procedures for managing, tracking, and documenting the work. This document, the NIF Operations Management Plan, NIF-5020544 (Ref. 1), and NIF Shot Operations Plan, NIF-5018506 (Ref. 2), together satisfy the requirements of the Conduct of Operations. Duties, responsibilities, and reporting requirements of the various positions associated with FInS, LASE, and TOPS maintenance are detailed in this plan. The FInS systems include both Real Property systems with asset management requirements specified in DOE Order 430.1C (Ref. 3) and Programmatic systems. In addition, for FInS, there is a list of the System Level Maintenance Plans (SLMPs) in NIF-1007419198 (Ref. 4) which provide the system descriptions and maintenance plan and schedule. In addition, the list includes the Reliability Centered Maintenance (RCM) and Experience Centered Maintenance (ECM) evaluations that have been performed for applicable FInS systems as well as reliability criticality per Section 3.5. The -AM version of the NIF Maintenance Plan focuses on the reliability program for FInS, LASE, TOPS, TASE, and NCS within the context of the overall NIF Reliability, Availability, and Maintainability (RAM) program and incorporates changes since the -AL version from August 2011 and has been updated to be fully consistent with the updates to Ref. 1. It also includes asset management considerations, updates to the Work Order (WO) process within the NIF Computerized Maintenance Management System (CMMS) which is EAM infor® System Maintenance and Reliability Tracking (SMaRT) (Ref. 5), and updates to metrics and key performance indicators (KPIs).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Characterization of Losses in Superconducting Radio-Frequency Cavities by Combined Temperature and Magnetic Field Mapping

Superconducting radio-frequency (SRF) cavities are one of the fundamental building blocks of modern particle accelerators. To achieve the highest quality factors (10 10 -10 11 ), SRF cavities are operated at liquid helium temperatures. Magnetic flux trapped on the surface of SRF cavities during cool-down below the critical temperature is one of the leading sources of residual RF losses. Instruments capable of detecting the distribution of trapped flux on the cavity surface are in high demand in order to better understand its relation to the cavity material, surface treatments and environmental conditions. We have designed, developed, and commissioned two novel diagnostic tools to measure the distribution of trapped flux at the surface of SRF cavities. One is a magnetic field scanning system (MFSS) which uses cryogenic Hall probes and anisotropic magnetoresistance sensors that fit the contour of a 1.3 GHz cavity. The second setup is a stationary, combined magnetic and temperature mapping system which uses AMR sensors and carbon resistor temperature sensors, covering the surface of a 3 GHz SRF cavity. The MFSS system revealed a non-uniform distribution of trapped flux on the cavities' surface, dependent on the magnitude of the applied magnetic field during field-cooling below the critical temperature. The MFSS shows that magnetic field scanning as a function of the RF field indicates redistribution of trapped flux at some locations. About ~ 33% of hot-spots observed by temperature mapping during high power RF tests overlapped with the high B-field spots. Almost all high B-field spots observed after field-cool were found to be overlapped on grain boundaries. A clear correlation between the hot- spot formed after quench and local trapped flux was found, providing insight on the RF dissipation of trap vortices. The combined B&T map system showed that the T-map system is capable of detecting hot-spots and quench location on the surface of the 3 GHz SRF cavity. Different distribution of trapped flux was measured after different cool-down and residual B-field, but, no variation in magnetic field distribution was observed during quench, possibly due to magnetic sensors being far from the quench location.

Parajuli, Ishwari↗

Cryogenic Performance of the SPT-SLIM Receiver

The South Pole Telescope Shirokoff Line Intensity Mapper (SPT-SLIM) is a millimeter-wave line-intensity mapping experiment, deployed on the South Pole Telescope (SPT) during the 2024-2025 Austral Summer season. This pathfinder experiment serves to demonstrate the on-sky operation of multi-pixel on-chip spectrometer technology. We present on the cryogenic performance of the SPT-SLIM receiver for this Year 1 observing campaign. The SPT-SLIM receiver utilizes an Adiabatic Demagnetization Referigerator (ADR) for cooling the focal plane of superconducting filterbank spectrometers to a temperature of 150mK. We demonstrate stable thermal performance of the focal plane module during observing operations in line with thermal modelling, enabling a cryogenic operation efficiency above 80%. We also report on the receiver control system design utilizing the Observatory Control System (OCS) platform for automated cryogenic operation on the SPT.

Young, Matthew [Fermilab]↗