Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Characterization of Partially Observed Epidemics - Application to COVID-19

This report documents a statistical method for the "real-time" characterization of partially observed epidemics. Observations consist of daily counts of symptomatic patients, diagnosed with the disease. Characterization, in this context, refers to estimation of epidemiological parameters that can be used to provide short-term forecasts of the ongoing epidemic, as well as to provide gross information for the time-dependent infection rate. The characterization problem is formulated as a Bayesian inverse problem, and is predicated on a model for the distribution of the incubation period. The model parameters are estimated as distributions using a Markov Chain Monte Carlo (MCMC) method, thus quantifying the uncertainty in the estimates. The method is applied to the COVID-19 pandemic of 2020, using data at the country, provincial (e.g., states) and regional (e.g. county) levels. The epidemiological model includes a stochastic component due to uncertainties in the incubation period. This model-form uncertainty is accommodated by a pseudo-marginal Metropolis-Hastings MCMC sampler, which produces posterior distributions that reflect this uncertainty. We approximate the discrepancy between the data and the epidemiological model using Gaussian and negative binomial error models; the latter was motivated by the over-dispersed count data. For small daily counts we find the performance of the calibrated models to be similar for the two error models. For large daily counts the negative-binomial approximation is numerically unstable unlike the Gaussian error model. Application of the model at the country level (for the United States, Germany, Italy, etc.) generally provided accurate forecasts, as the data consisted of large counts which suppressed the day-to-day variations in the observations. Further, the bulk of the data is sourced over the duration before the relaxation of the curbs on population mixing, and is not confounded by any discernible country-wide second wave of infections. At the state-level, where reporting was poor or which evinced few infections (e.g., New Mexico), the variance in the data posed some, though not insurmountable, difficulties, and forecasts were able to capture the data with large uncertainty bounds. The method was found to be sufficiently sensitive to discern the flattening of the infection and epidemic curve due to shelter-in-place orders after around 90% quantile for the incubation distribution (about 10 days for COVID-19). The proposed model was also used at a regional level to compare the forecasts for the central and north-west regions of New Mexico. Modeling the data for these regions illustrated different disease spread dynamics captured by the model. While in the central region the daily counts peaked in the late April, in the north-west region the ramp-up continued for approximately three more weeks.

59 BASIC BIOLOGICAL SCIENCES↗

Characterizing energy dependence and count rate performance of a dual scintillator fiber-optic detector for computed tomography

Purpose: Kilovoltage (kV) x-rays pose a significant challenge for radiation dosimetry. In the kV energy range, even small differences in material composition can result in significant variations in the absorbed energy between soft tissue and the detector. In addition, the use of electronic systems in light detection has demonstrated measurement losses at high photon fluence rates incident to the detector. This study investigated the feasibility of using a novel dual scintillator detector and whether its response to changes in beam energy from scatter and hardening is readily quantified. The detector incorporates a tissue-equivalent plastic scintillator and a gadolinium oxysulfide scintillator, which has a higher sensitivity to scatter x-rays. Methods: The detector was constructed by coupling two scintillators: (1) small cylindrical plastic scintillator, 500 μm in diameter and 2 mm in length, and (2) 100 micron sheet of gadolinium oxysulfide 500 μm in diameter, each to a 2 m long optical fiber, which acts as a light guide to transmit scintillation photons from the sensitive element to a photomultiplier tube. Count rate linearity data were obtained from a wide range of exposure rates delivered from a radiological x-ray tube by adjusting the tube current. The data were fitted to a nonparalyzable dead time model to characterize the time response. The true counting rate was related to the reference free air dose air rate measured with a 0.6 cm{sup 3} Radcal{sup ®} thimble chamber as described in AAPM Report No. 111. Secondary electron and photon spectra were evaluated using Monte Carlo techniques to analyze ionization quenching and photon energy-absorption characteristics from free-in-air and in phantom measurements. The depth/energy dependence of the detector was characterized using a computed tomography dose index QA phantom consisting of nested adult head and body segments. The phantom provided up to 32 cm of acrylic with a compatible 0.6 cm{sup 3} calibrated ionization chamber to measure the reference air kerma. Results: Each detector exhibited counting losses of 5% when irradiated at a dose rate of 26.3 mGy/s (Gadolinium) and 324.3 mGy/s (plastic). The dead time of the gadolinium oxysulfide detector was determined to be 48 ns, while the dead time of the plastic scintillating detector was unable to accurately be calculated due to poor counting statistics from low detected count rates. Noticeable depth/energy dependence was observed for the plastic scintillator for depths greater than 16 cm of acrylic that was not present for measurements using the gadolinium oxysulfide scintillator, leading us to believe that quenching may play a larger role in the depth dependence of the plastic scintillator than the incident x-ray energy spectrum. When properly corrected for dead time effects, the energy response of the gadolinium oxysulfide scintillator is consistent with the plastic scintillator. Using the integrated dual detector method was superior to each detector individually as the depth-dependent measure of dose was correctable to less than 8% between 100 and 135 kV. Conclusions: The dual scintillator fiber-optic detector accommodates a methodology for energy dependent corrections of the plastic scintillator, improving the overall accuracy of the dosimeter across the range of diagnostic energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Suite of Mechanistic Epidemiological Decision Support Tools

Objective: We will demonstrate tools that allow mechanistic contraints on disease progression and epidemic spread to play off against interventions, mitigation, and control measures. The fundamental mechanisms of disease progression and epidemic spread provide important constraints on interpreting changing epidemic cases counts with time and geography in the context of on-going interventions, mitigations, and controls. Models such as these that account for the effects of human actions can also allow evaluation of the importance of categories of epidemic and disease controls. Introduction: We present the EpiEarly, EpiGrid, and EpiCast tools for mechanistically-based biological decision support. The range of tools covers coarse-, medium-, and fine-grained models. The coarse-grained, aggregated time-series only data tool (EpiEarly) provides a statistic quantifying epidemic growth potential and associated uncertainties. The medium grained, geographically-resolved model (EpiGrid) is based on differential equation type simulations of disease and epidemic progression in the presence of various human interventions geared toward understanding the role of infection control, early vs. late diagnosis, vaccination, etc. in outbreak control. A fine-grained hybrid-agent epidemic model (EpiCast) with diurnal agent travel and contagion allows the analysis of the importance of contact-networks, travel, and detailed intervention strategies for the control of outbreaks and epidemics. Methods: We use three types of methods for simulation and analysis. They are: (1) Bayesian and regression methods allowing estimation of the basic reproductive number from case-count data; (2) ordinary-differential equation integration with modifications to account for discreteness of disease spread when case counts are small (we include space- and time-dependent effects); and (3) methods that hybridize agent-based travel, mixing, and disease progression with nested-mass action contagion (i.e. not fully agent-based). From the perspective of decision support, the crucial feature of mechanistic infectious epidemiological models is a way to capture the human interventions that determine epidemic outcome. Categorizing types of mitigation into those that change the force of infection, and those that branch disease progression allows a common framework that can be extended from medium-grained models through fine-grained. Our canonical example is our EpiGrid tool which allows for the modulation of the force of infection (i.e. contagion) with time (and potentially space), the vaccination of a susceptible population in a geographically-targeted manner, movement controls, and branching our disease progression model to account for early- vs. late-intervention during host disease progression.ResultsWe will present analysis of diseases that exemplify the various aspects of analysis in support of outbreak and epidemic control. Human and animal diseases relevant to this demonstration include rinderpest, avian influenza, and measles. We will begin with EpiEarly’s estimate of epidemic potential using aggregated time-dependent case-count data. The key observation for EpiEarly is that under a wide range of situations a disease's reproductive number should be generalized to a distribution of possibilities to account for inherent randomness and other factors (including the variability of a disease contact network). We will then continue with a demonstration of EpiGrid’s capabilities for understanding and modelling the role of interventions including contagion control (the force of infection), treatment (changing disease progression and infectiousness depending on treatment), vaccination, culling, and movement controls. We will briefly touch on the capabilities of EpiCast for more detailed analysis of specific intervention strategies. Conclusions: We will demonstrate examples where modeling either contributed or plausibly would contribute to informing epidemic and outbreak control constrained by the possibilities of the underlying epidemic and disease dynamics.

Geospatial↗

Efficient data reduction for time-of-flight neutron scattering experiments on single crystals

Event-mode data collection presents remarkable new opportunities for time-of-flight neutron scattering studies of collective excitations, diffuse scattering from short-range atomic and magnetic structures, and neutron crystallography. In these experiments, large volumes of the reciprocal space are surveyed, often using different wavelengths and counting times. These data then have to be added together, with accurate propagation of the counting errors. This paper presents a statistically correct way of adding and histogramming the data for single-crystal time-of-flight neutron scattering measurements. In order to gain a broader community acceptance, particular attention is given to improving the efficiency of calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron detection using Poisson distribution comparison independent of count rate based on correlation signals

Embodiments are directed to comparison-based methods of conditionally assessing the excess in correlation of an unknown neutron count measurement compared to the correlation present in a data defined as background, and to providing a technical definition of excess correlation intended to properly handle the measured excess correlation. The degree of correlation between an unknown source and background can be used to prevent masking of neutron count data for the source by background radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Second ARM Aerosol Chemical Speciation Monitor Users’ Meeting Report

The aerosol chemical speciation monitor (ACSM) was developed to adapt the technology of the aerosol mass spectrometer (AMS) to routine, long-term, standalone monitoring. The calculation of particulate mass concentration from ACSM data requires the measurement of the response of the instrument to aerosol of specific size and composition as well as assumptions about the instrument response based on laboratory measurements and field experience acquired over more than two decades of operation of AMS and a decade of operation of the ACSM. Three parameters in the concentration calculations that are particularly important are the NO3 response factor (RFNO3), relative ionization efficiency (RIE), and the collection efficiency (CE). The values of RFNO3 and RIEs are determined from calibration, however the jump calibration method previously used in calibration can result in errors in the RIE for sulfate. This has been corrected by implementing a continuous calibration method. The default collection efficiency is 0.5. This has been shown to result in mass loadings that do not agree with mass determinations from other instruments because of effects of composition on the vaporization of the particles. The previous work of investigators addressing this issue is discussed. After preliminary work on ACSM and scanning mobility particle sizer (SMPS) data from the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility Southern Great Plains (SGP) observatory collected in late 2016 and 2017 produced a parameterization of composition dependent collection efficiency very different from the results of previous studies, SMPS data were examined and we determined that there was significant mass that the instrument did not capture because the particles with diameters larger than 465 nm are not counted by this instrument. Data for the ultra-high-sensitivity aerosol spectrometer (UHSAS), SMPS, and ACSM are available for nearly all of 2019. The data from UHSAS and SMPS collected in 2019 were compared. We found that the UHSAS data has particle counts and total volumes significantly less than measured by the condensation particle counter (CPC) and SMPS. The SMPS data were extended by fitting the average volume distribution with a log normal curve and using this relationship to estimate a mass value for the SMPS over extended diameter range. The extended SMPS mass values result in a CDCE parameterization that is in better agreement with the results of other investigators, but is still different from other formulations. The working group recommends that the ACSM data be processed with a collective efficiency (CE)=1, that this be documented clearly in the metadata, and the use of the default CE of 0.5 or a formulation of composition-dependent collection efficiencies (CDCE) chosen by the user should be implemented based on the ammonium nitrate mass fraction. This is clearly necessary for the wintertime SGP ACSM data because of the high nitrate concentrations.

47 OTHER INSTRUMENTATION↗

High-count rate effects in event processing for XRISM/ Resolve X-ray microcalorimeter: I. Ground test

The spectroscopic performance of an X-ray microcalorimeter is compromised at high count rates. We utilize the Resolve X-ray microcalorimeter onboard the XRISM satellite to examine the effects observed during high-count rate measurements and propose modeling approaches to mitigate them. We specifically address the following instrumental effects that impact performance: CPU limit, pile-up, and untriggered electrical cross-talk. Experimental data at high count rates were acquired during ground testing using the flight model instrument and a calibration X-ray source. In the experiment, data processing not limited by the performance of the onboard CPU was run in parallel, which cannot be done in orbit. This makes it possible to access the data degradation caused by limited CPU performance. We use these data to develop models that allow for a more accurate estimation of the aforementioned effects. To illustrate the application of these models in observation planning, we present a simulated observation of GX 13+1. Understanding and addressing these issues is crucial to enhancing the reliability and precision of X-ray spectroscopy in situations characterized by elevated count rates.

47 OTHER INSTRUMENTATION↗

Surrogate Distributed Radiological Sources—Part II: Aerial Measurement Campaign

In this second part of a multipaper series, we present results from outdoor aerial measurements of surrogate distributed gamma-ray sources. Here we detail the design, manufacture, and testing of 300 individual ~7 mCi Cu-64 sealed sources at the Washington State University (WSU) research reactor and their deployment in various source patterns (each comprising up to 100 point sources) during the aerial measurement campaign. We show the results of two such measurements, in which approximate source shapes and qualitative source intensities can be seen from the count rate versus position plots, even without performing reconstructions. We also detail our efforts in ground-truthing the deployed sources and comparing measured gamma-ray data to model predictions. In particular, we compare measured versus expected count data using the Poisson deviance formalism of Part I to evaluate whether the fielded surrogate point-source arrays “look like” their truly continuous distributed source analogs. More generally, we find that the point-source array technique provides high source placement accuracy, relative ease of quantifying the true source configuration, scalability to source dimensions of ≲100 m, ease of reconfiguration and removal, and relatively low dose to personnel. Finally, we consider potential improvements and generalizations of the point-source array technique for future measurement campaigns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Should the Standard Count Be Excluded from Neutron Probe Calibration?

About 6 decades after its introduction, the neutron probe remains one of the most accurate methods for indirect measurement of soil moisture content. Traditionally, the calibration of a neutron probe involves the ratio of the neutron count in the soil to a standard count, which is the neutron count in the fixed environment such as the probe shield or a specially-designed calibration tank. The drawback of this count-ratio-based calibration is that the error in the standard count is carried through to all the measurements. An alternative calibration is to use the neutron counts only, not the ratio, with proper correction for radioactive decay and counting time. To evaluate both approaches, the shield counts of a neutron probe used for three decades were analyzed. The results show that the surrounding conditions have a substantial effect on the standard count. The error in the standard count also impacts the calculation of water storage and could indicate false consistency among replicates. The analysis of the shield counts indicates negligible aging effect of the instrument over a period of 26 years. It is concluded that, by excluding the standard count, the use of the count-based calibration is appropriate and sometimes even better than ratio-based calibration. The count-based calibration is especially useful for historical data when the standard count was questionable or absent

54 ENVIRONMENTAL SCIENCES↗

PROBING NUCLEAR DYNAMICS IN REAL-PHOTON EXPERIMENTS

Experimental results on the reactions ?d ? ?0d, ?d ? pn, ?3He ? ppn, and ?3He ? pd obtained in Hall B at Jefferson Lab at photon energies between 0.3 and 3.0 GeV are discussed. The goal of the measurements is to study the transition between long- and short-range nuclear dynamics, as well as more specific dynamical effects, such as manifestations of three-body mechanisms. Conventional nuclear models can describe the data up to a momentum transfer of ~ 1 (GeV/c)2. All the studied reactions on deuterium clearly show scaling properties consistent with the predictions of the Constituent Counting Rules. The data on 3He suggest that the favorable energy range for the study of three-body mechanisms is 0.6 - 0.8 GeV.

ILIEVA, YORDANKA↗

Analysis of calibration data for the uranium active neutron coincidence counting collar with attention to errors in the measured neutron coincidence rate

The declared linear density of 238 U and 235 U in fresh low enriched uranium light water reactor fuel assemblies can be verified for nuclear safeguards purposes using a neutron coincidence counter collar in passive and active mode, respectively. The active mode calibration of the Uranium Neutron Collar - Light water reactor fuel (UNCL) instrument is normally performed using a non-linear fitting technique. The fitting technique relates the measured neutron coincidence rate (the predictor) to the linear density of 235 U (the response) in order to estimate model parameters of the nonlinear Parte equation, which traditionally is used to model the calibration data. Alternatively, following a simple data transformation, the fitting can also be performed using standard linear fitting methods. This article compares performance of the nonlinear technique to the linear technique, using a range of possible error variance magnitudes in the measured neutron coincidence rate. We develop the required formalism and then apply the traditional (nonlinear) and alternative approaches (linear) to the same experimental and corresponding simulated representative datasets. Here, we find that, in this context, because of the magnitude of the errors in the predictor, it is preferable not to transform to a linear model, and it is preferable not to adjust for the errors in the predictor when inferring the model parameters.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of processing algorithms to enable high-rate microcalorimeter array operation

The millisecond-scale decay constants of microcalorimeter gamma-ray pulses present challenges for operation at high count rates needed to compete with semiconductor HPGe detectors. If using conventional optimal filtering methods, pulse records with pileup events are simply discarded, leading to a large fraction of data unused when count rates are large. For single pixel rates exceeding 1-2 Hz, improved pulse processing algorithms are needed to better deal with pileup and increase the filter throughput. A 256-pixel array operating at 10 Hz per pixel would provide a total counting rate of 2.5 kHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fractal Dimension Calculation for Big Data Using Box Locality Index

The box-counting approach for fractal dimension calculation is scaled up for big data using a data structure named box locality index (BLI). The BLI is constructed as key-value pair style with the key (an integer array) indexing the location of a “box” (i.e., a gird cell on the multi-dimensional space embedding a given dataset) and the value counting the number of data points inside the box (called “box occupancy”). Compared with the traditionally used E-dim tree, the BLI avoids complex hierarchical structure and encodes only necessary information required by box-counting approach for fractal dimension calculation. Moreover, the key-value pair nature of BLI, together with the fact that the box occupancy is aggregatable, grants box-counting approach the needed scalability for fractal dimension calculation of big data using distributed computing techniques (e.g., MapReduce and Spark). Taking the advantage of the BLI, MapReduce and Spark methods for fractal dimension calculation of big data are developed, which conduct box-counting for each grid level as a cascade of MapReduce/Spark jobs in a bottom-up fashion. In an empirical validation, the MapReduce and Spark methods demonstrated good effectiveness and efficiency in fractal calculation of a big synthetic dataset. In summary, this work provides an efficient solution for the estimation of intrinsic dimension of big data that is essential for many machine learning methods and data analytics.

Fractal dimension, Intrinsic dimension, Box-counti↗

Alpha Air Sample Counting Efficiency Versus Dust Loading: Evaluation of a Large Data Set

Dust loading on air sample filters is known to cause a loss of efficiency for direct counting of alpha activity on the filters, but the amount of dust loading and the correction factor needed to account for attenuated alpha particles is difficult to assess. In this paper, correction factors are developed by statistical analysis of a large database of air sample results for a uranium and plutonium processing facility at the Savannah River Site. As is typically the case, dust-loading data is not directly available, but sample volume is found to be a reasonable proxy measure; the amount of dust loading is inferred by a combination of the derived correction factors and a Monte Carlo model. The technique compares the distribution of activity ratios [beta/(beta + alpha)] by volume and applies a range of correction factors on the raw alpha count rate. The best-fit results with this method are compared with MCNP modeling of activity uniformly deposited in the dust and analytical laboratory results of digested filters. Finally, a linear fit is proposed to evenly-deposited alpha activity collected on filters with dust loading over a range of about 2 mg cm -2 to 1,000 mg cm -2 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Validation Testing of TruckScan to Assay Large Sacks of Fukushima Radioactive Debris on a Truck

As a result of the March 2011 earthquake and resulting tsunami in Japan, there was a serious accident at the Fukushima Dai-ichi Nuclear Power Plant. This accident has contaminated soil and vegetation in a wide area around the plant. Decontamination projects over the last 4 years have resulted in large numbers of 1 cubic meter canvas bags of debris, commonly called Super Sacks [SS]. These are currently stored nearby where they were generated, but starting in 2015, they will be moved to various Interim Storage Facilities [ISF]. Trucks will typically carry 8-20 of these SSs. When the trucks arrive at the ISF they need to be rapidly sorted into groups according to radioactivity level, for efficient subsequent processing. Canberra Industries, Inc. [CI] has designed a new truck monitoring system 'TruckScan' for use at these ISFs. The TruckScan system must measure the entire truck loaded with multiple closely packed SSs, and generate a nuclide specific assay report showing the radioactivity in each individual SS. The Canberra-Japan office, along with Obayashi Corporation have performed validation testing to demonstrate to the regulatory authorities that the proposed technique was sufficiently accurate. These validation tests were conducted at a temporary storage area in Fukushima prefecture. Decontaminated waste of various representative types and of various levels of radioactivity was gathered and mixed to create homogeneous volumes. These volumes were sampled multiple times and assayed with laboratory HPGe detectors to determine the reference concentration of each pile. Multiple SSs were loaded from each pile. Some of the SSs were filled 50% full, others 75% full, and others 100% full, to represent the typical loading configuration of the existing SSs in the field. The content of the SSs are either sand, soil, or vegetation with densities ranging from 0.3 g/cc - 1.6 g/cc. These SSs with known concentrations of Cs-134 and Cs-137 were then loaded onto trucks in a variety of configurations, typical of how they might be on the real trucks. A partial system was installed at the site and used to assay these trucks with the various loading configurations. Whereas the full system will have 8 collimated 3 x 3'' NaI detectors, the test system only had two detectors; therefore the truck was moved and counted 4 times. The data were acquired and analyzed with the Canberra Genie software to determine the peak counts for both Cesium nuclides. That data was then analyzed with a prototype version of a Maximum Entropy algorithm, to determine the individual SS activity. The goal of the validation tests was to demonstrate that the system could detect 1000 Bq/kg in 15 seconds, and to determine how accurately it could quantify individual SSs. The validation tests demonstrated that the product would perform as predicted. The TruckScan results were consistent with the sample assay results [y = 1.0029 x, R{sup 2} = 0.914]. The Total Propagated Uncertainty, including both uncertainties from these tests and others that were estimated but not tested was 16.6% percent. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Revisiting galactic black hole binary GX 339-4 by using 2007 – 2014 Swift XRT observations

This work aims to study the X-ray properties of the galactic black hole binary GX 339-4. Focus of the study is on exploration of data from Swift-XRT in exclusively photon-counting mode. We use data from 2007 up to August 2014, which contain about 40 pointing observations with level 1 data. The flux of GX 339-4 varies in a factor of 100 during this period of observations. For the purpose of this work, we also try to develop a system to conduct standard SWIFT XRT data reduction automatically, in order to greatly reduce time when working with data bulk, which produces images, lightcurves as well as spectra. We also develop another system to conduct fitting of bulk spectral data with a two-component model, disk blackbody and power-law. The fitting results show that no data have a reduced chi-squared > 2. The fraction of the disk to total flux and the power-law to total flux range from 0.00389 – 0.994 and 0.00605 – 0.996, respectively. From the analysis of the disk component, we obtain the value of the innermost disk radius that does not show any large scale truncation which is in a good agreement with a previous study that used 2007 – 2011 Swift-XRT data, indicating that the systems we developed work properly.

79 ASTRONOMY AND ASTROPHYSICS↗

GPU-enabled extreme-scale turbulence simulations: Fourier pseudo-spectral algorithms at the exascale using OpenMP offloading

Fourier pseudo-spectral methods for nonlinear partial differential equations are of wide interest in many areas of advanced computational science, including direct numerical simulation of three-dimensional (3-D) turbulence governed by the Navier-Stokes equations in fluid dynamics. This paper presents a new capability for simulating turbulence at a new record resolution up to 35 trillion grid points, on the world's first exascale computer, Frontier, comprising AMD MI250x GPUs with HPE's Slingshot interconnect and operated by the US Department of Energy's Oak Ridge Leadership Computing Facility (OLCF). Key programming strategies designed to take maximum advantage of the machine architecture involve performing almost all computations on the GPU which has the same memory capacity as the CPU, performing all-to-all communication among sets of parallel processes directly on the GPU, and targeting GPUs efficiently using OpenMP offloading for intensive number-crunching including 1-D Fast Fourier Transforms (FFT) performed using AMD ROCm library calls. With 99% of computing power on Frontier being on the GPU, leaving the CPU idle leads to a net performance gain via avoiding the overhead of data movement between host and device except when needed for some I/O purposes. Memory footprint including the size of communication buffers for MPI_ALLTOALL is managed carefully to maximize the largest problem size possible for a given node count. Detailed performance data including separate contributions from different categories of operations to the elapsed wall time per step are reported for five grid resolutions, from 2048 3 on a single node to 32768 3 on 4096 or 8192 nodes out of 9408 on the system. Both 1D and 2D domain decompositions which divide a 3D periodic domain into slabs and pencils respectively are implemented. The present code suite (labeled by the acronym GESTS, GPUs for Extreme Scale Turbulence Simulations) achieves a figure of merit (in grid points per second) exceeding goals set in the Center for Accelerated Application Readiness (CAAR) program for Frontier. The performance attained is highly favorable in both weak scaling and strong scaling, with notable departures only for 2048 3 where communication is entirely intra-node, and for 32768 3 , where a challenge due to small message sizes does arise. Communication performance is addressed further using a lightweight test code that performs all-to-all communication in a manner matching the full turbulence simulation code. Performance at large problem sizes is affected by both small message size due to high node counts as well as dragonfly network topology features on the machine, but is consistent with official expectations of sustained performance on Frontier. Overall, although not perfect, the scalability achieved at the extreme problem size of 32768 3 (and up to 8192 nodes — which corresponds to hardware rated at just under 1 exaflop/sec of theoretical peak computational performance) is arguably better than the scalability observed using prior state-of-the-art algorithms on Frontier's predecessor machine (Summit) at OLCF. New science results for the study of intermittency in turbulence enabled by this code and its extensions are to be reported separately in the near future.

3D fast Fourier transform↗

Optical galaxy cluster mock catalogs with realistic projection effects: Validations with the SDSS clusters

Galaxy clusters identified in optical imaging surveys suffer from projection effects: Physically unassociated galaxies along a cluster’s line of sight can be counted as its members and boost the observed richness (the number of cluster members). To model the impact of projection on cluster cosmology analyses, we apply a halo occupation distribution model to 𝑁-body simulations to simulate the red galaxies contributing to cluster members, and we use the number of galaxies in a cylinder along the line of sight (counts in cylinders) to model the impact of projection on cluster richness. We compare three projection models: uniform, quadratic, and Gaussian, and we convert between them by matching their effective cylinder volumes. We validate our mock catalogs using SDSS redMaPPer clusters’ data vectors, including counts vs richness, stacked lensing signal, spectroscopic redshift distribution of member galaxies, and richness remeasured on a redshift grid. We find the former two are insensitive to the projection model, while the latter two favor a quadratic projection model with a width of ≈180 ℎ −1 Mpc (equivalent to the volume of a uniform model with a width of 100 ℎ −1 Mpc and a Gaussian model with a width of 110 ℎ −1 Mpc, or a Gaussian redshift error of 0.04). Furthermore, our framework provides an efficient and flexible way to model optical cluster data vectors, paving the way for a simulation-based joint analysis for clusters, galaxies, and shear.

79 ASTRONOMY AND ASTROPHYSICS↗