Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cost data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Environmental Cost Analysis System (ECAS) Status and Compliance Requirements for EM Consolidated Business Center Contracts - 13204

The Department of Energy (DOE) Office of Environmental Management (EM) has developed a web-accessible database to collect actual cost data from completed EM projects to support cost estimating and analysis. This Environmental Cost Analysis System (ECAS) database was initially deployed in early 2009 containing the cost and parametric data from 77 decommissioning, restoration, and waste management projects completed under the Rocky Flats Closure Project. In subsequent years we have added many more projects to ECAS and now have a total of 280 projects from 8 major DOE sites. This data is now accessible to DOE users through a web-based reporting tool that allows users to tailor report outputs to meet their specific needs. We are using it as a principal resource supporting the EM Consolidated Business Center (EMCBC) and the EM Applied Cost Engineering (ACE) team cost estimating and analysis efforts across the country. The database has received Government Accountability Office review as supporting its recommended improvements in DOE's cost estimating process, as well as review from the DOE Office of Acquisition and Project Management (APM). Moving forward, the EMCBC has developed a Special Contract Requirement clause or 'H-Clause' to be included in all current and future EMCBC procurements identifying the process that contractors will follow to provide DOE their historical project data in a format compatible with ECAS. Changes to DOE O 413.3B implementation are also in progress to capture historical costs as part of the Critical Decision project closeout process. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In-situ Detection of Glovebox Glove Degradation Prior to Glove Failure; Effects on Safety, Waste, and Operational Costs - 20402

Glovebox glove pressure decay leak testing and analysis of the data can greatly improve glovebox safety, minimize Transuranic (TRU) glove waste, and minimize operational cost. It is well known, the weakest point of containment on a glovebox is the glove. Mitigating unplanned openings in gloves is critical to minimizing operational and safety costs in glovebox operations. Mitigating unplanned glove openings due to glove failures will be discussed in this paper. The lack of an engineered solution to determine a gloves operational life in nuclear operations, has lead to use of theoretical and manual subjective methods to determine the life and safety of a glovebox glove. Whether the glove is inspected visually prior to use, or gloves are changed regularly to theoretically avoid failure, both the operators PPE and the room are being exposed to contamination, or un-necessary amounts of TRU glove waste are being generated. Millions of dollars yearly in operational costs are spent on glove failures due to loss of production, incident analysis, regulatory audits, clean up, and paperwork. In a nuclear application, a glove failure could contaminate an operator and laboratory, shut down the operation for weeks, potentially create a regulatory audit, and potentially create a media frenzy; the damages to the organization can be astronomical. Elimination of glove failures is possible by tracking glove material degradation and setting limits to allow glove change when it becomes necessary, prior to glove failure. Analytical pressure decay leak testing allows the detection of material degradation, and in turn the ability to limit operational glove failures. A German based company called MK Versuchsanlagen, e.K., has developed an advanced Glove Integrity Testing System. The system, with its use of proprietary RFID and special software technology, is unique in its capabilities. The system is capable to perform highly accurate regular glove testing on any size glovebox line in minimal time. The system records and can analyze a tremendous amount of system data that in turn can determine, for example, a safe glove change time prior to a glove material failure. This paper will show how an advanced Glove Integrity Testing System can detect glove material degradation and help determine a safe change point prior to glove failure. Pressure decay curves of new gloves and recorded effects of accelerated aging on the glove over time will be shown. The use of this technology in nuclear facilities can greatly improve glovebox operational safety, minimize glovebox glove TRU waste, and save organizations tremendous costs in downtime, clean up, documentation, and potential regulatory review. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of an Enhanced Payback Function for the Superior Energy Performance Program

The U.S. DOE Superior Energy Performance (SEP) program provides recognition to industrial and commercial facilities that achieve certification to the ISO 50001 energy management system standard and third party verification of energy performance improvements. Over 50 industrial facilities are participating and 28 facilities have been certified in the SEP program. These facilities find value in the robust, data driven energy performance improvement result that the SEP program delivers. Previous analysis of SEP certified facility data demonstrated the cost effectiveness of SEP and identified internal staff time to be the largest cost component related to SEP implementation and certification. This paper analyzes previously reported and newly collected data of costs and benefits associated with the implementation of an ISO 50001 and SEP certification. By disaggregating “sunk energy management system (EnMS) labor costs”, this analysis results in a more accurate and detailed understanding of the costs and benefits of SEP participation. SEP is shown to significantly improve and sustain energy performance and energy cost savings, resulting in a highly attractive return on investment. To illustrate these results, a payback function has been developed and is presented. On average facilities with annual energy spend greater than $2M can expect to implement SEP with a payback of less than 1.5 years. Finally, this paper also observes and details decreasing facility costs associated with implementing ISO 50001 and certifying to the SEP program, as the program has improved from pilot, to demonstration, to full launch.

Therkelsen, Peter↗

Cost Analysis In A Multi-Mission Operations Environment

Spacecraft control centers have evolved from dedicated, single-mission or single missiontype support to multi-mission, service-oriented support for operating a variety of mission types. At the same time, available money for projects is shrinking and competition for new missions is increasing. These factors drive the need for an accurate and flexible model to support estimating service costs for new or extended missions; the cost model in turn drives the need for an accurate and efficient approach to service cost analysis. The National Aeronautics and Space Administration (NASA) Huntsville Operations Support Center (HOSC) at Marshall Space Flight Center (MSFC) provides operations services to a variety of customers around the world. HOSC customers range from launch vehicle test flights; to International Space Station (ISS) payloads; to small, short duration missions; and has included long duration flagship missions. The HOSC recently completed a detailed analysis of service costs as part of the development of a complete service cost model. The cost analysis process required the team to address a number of issues. One of the primary issues involves the difficulty of reverse engineering individual mission costs in a highly efficient multimission environment, along with a related issue of the value of detailed metrics or data to the cost model versus the cost of obtaining accurate data. Another concern is the difficulty of balancing costs between missions of different types and size and extrapolating costs to different mission types. The cost analysis also had to address issues relating to providing shared, cloud-like services in a government environment, and then assigning an uncertainty or risk factor to cost estimates that are based on current technology, but will be executed using future technology. Finally the cost analysis needed to consider how to validate the resulting cost models taking into account the non-homogeneous nature of the available cost data and the decreasing flight rate. This paper presents the issues encountered during the HOSC cost analysis process, and the associated lessons learned. These lessons can be used when planning for a new multi-mission operations center or in the transformation from a dedicated control center to multi-center operations, as an aid in defining processes that support future cost analysis and estimation. The lessons can also be used by mature serviceoriented, multi-mission control centers to streamline or refine their cost analysis process.

Newhouse, M.↗

Benchmarking Non-Hardware Balance-of-System (Soft) Costs for U.S. Photovoltaic Systems Using a Bottom-Up Approach and Installer Survey

This report presents results from the first U.S. Department of Energy (DOE) sponsored, bottom-up data-collection and analysis of non-hardware balance-of-system costs—often referred to as “business process” or “soft” costs—for residential and commercial photovoltaic (PV) systems. Annual expenditure and labor-hour-productivity data are analyzed to benchmark 2010 soft costs related to the DOE priority areas of (1) customer acquisition; (2) permitting, inspection, and interconnection; (3) installation labor; and (4) installer labor for arranging third-party financing. Annual expenditure and labor-hour data were collected from 87 PV installers. After eliminating outliers, the survey sample consists of 75 installers, representing approximately 13% of all residential PV installations and 4% of all commercial installations added in 2010. Including assumed permitting fees, in 2010 the average soft costs benchmarked in this analysis total $1.50/W for residential systems (ranging from $0.66/W to $1.66/W between the 20th and 80th percentiles). For commercial systems, the median 2010 benchmarked soft costs (including assumed permitting fees) are $0.99/W for systems smaller than 250 kW (ranging from $0.51/W to $1.45/W between the 20th and 80th percentiles) and $0.25/W for systems larger than 250 kW (ranging from $0.17/W to $0.78/W between the 20th and 80th percentiles). Additional soft costs not benchmarked in the present analysis (e.g., installer profit, overhead, financing, and contracting) are significant and would add to these figures. The survey results provide a benchmark for measuring—and helping to accelerate—progress over the next decade toward achieving the DOE SunShot Initiative’s soft-cost-reduction targets. We conclude that the selected non-hardware business processes add considerable cost to U.S. PV systems, constituting 23% of residential PV system price, 17% of small commercial system price, and 5% of large commercial system price (in 2010). These processes present significant opportunities for further cost reductions and labor-productivity gains.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cost Analysis in a Multi-Mission Operations Environment

Spacecraft control centers have evolved from dedicated, single-mission or single mission-type support to multi-mission, service-oriented support for operating a variety of mission types. At the same time, available money for projects is shrinking and competition for new missions is increasing. These factors drive the need for an accurate and flexible model to support estimating service costs for new or extended missions; the cost model in turn drives the need for an accurate and efficient approach to service cost analysis. The National Aeronautics and Space Administration (NASA) Huntsville Operations Support Center (HOSC) at Marshall Space Flight Center (MSFC) provides operations services to a variety of customers around the world. HOSC customers range from launch vehicle test flights; to International Space Station (ISS) payloads; to small, short duration missions; and has included long duration flagship missions. The HOSC recently completed a detailed analysis of service costs as part of the development of a complete service cost model. The cost analysis process required the team to address a number of issues. One of the primary issues involves the difficulty of reverse engineering individual mission costs in a highly efficient multi-mission environment, along with a related issue of the value of detailed metrics or data to the cost model versus the cost of obtaining accurate data. Another concern is the difficulty of balancing costs between missions of different types and size and extrapolating costs to different mission types. The cost analysis also had to address issues relating to providing shared, cloud-like services in a government environment, and then assigning an uncertainty or risk factor to cost estimates that are based on current technology, but will be executed using future technology. Finally the cost analysis needed to consider how to validate the resulting cost models taking into account the non-homogeneous nature of the available cost data and the decreasing flight rate. This paper presents the issues encountered during the HOSC cost analysis process, and the associated lessons learned. These lessons can be used when planning for a new multi-mission operations center or in the transformation from a dedicated control center to multi-center operations, as an aid in defining processes that support future cost analysis and estimation. The lessons can also be used by mature service-oriented, multi-mission control centers to streamline or refine their cost analysis process.

Felton, Larry↗

Multivariate analysis of progressive thermal desorption coupled gas chromatography-mass spectrometry.

Thermal decomposition of poly dimethyl siloxane compounds, Sylgard{reg_sign} 184 and 186, were examined using thermal desorption coupled gas chromatography-mass spectrometry (TD/GC-MS) and multivariate analysis. This work describes a method of producing multiway data using a stepped thermal desorption. The technique involves sequentially heating a sample of the material of interest with subsequent analysis in a commercial GC/MS system. The decomposition chromatograms were analyzed using multivariate analysis tools including principal component analysis (PCA), factor rotation employing the varimax criterion, and multivariate curve resolution. The results of the analysis show seven components related to offgassing of various fractions of siloxanes that vary as a function of temperature. Thermal desorption coupled with gas chromatography-mass spectrometry (TD/GC-MS) is a powerful analytical technique for analyzing chemical mixtures. It has great potential in numerous analytic areas including materials analysis, sports medicine, in the detection of designer drugs; and biological research for metabolomics. Data analysis is complicated, far from automated and can result in high false positive or false negative rates. We have demonstrated a step-wise TD/GC-MS technique that removes more volatile compounds from a sample before extracting the less volatile compounds. This creates an additional dimension of separation before the GC column, while simultaneously generating three-way data. Sandia's proven multivariate analysis methods, when applied to these data, have several advantages over current commercial options. It also has demonstrated potential for success in finding and enabling identification of trace compounds. Several challenges remain, however, including understanding the sources of noise in the data, outlier detection, improving the data pretreatment and analysis methods, developing a software tool for ease of use by the chemist, and demonstrating our belief that this multivariate analysis will enable superior differentiation capabilities. In addition, noise and system artifacts challenge the analysis of GC-MS data collected on lower cost equipment, ubiquitous in commercial laboratories. This research has the potential to affect many areas of analytical chemistry including materials analysis, medical testing, and environmental surveillance. It could also provide a method to measure adsorption parameters for chemical interactions on various surfaces by measuring desorption as a function of temperature for mixtures. We have presented results of a novel method for examining offgas products of a common PDMS material. Our method involves utilizing a stepped TD/GC-MS data acquisition scheme that may be almost totally automated, coupled with multivariate analysis schemes. This method of data generation and analysis can be applied to a number of materials aging and thermal degradation studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Military housing foam application and analysis

Sandia and Forest City have established a Cooperative Research and Development Agreement (CRADA), the partnership provides a unique opportunity to take technology research and development from demonstration to application in sustainable communities. This project consists of two activities conducted in Hawaii that focus on performance, integration and application of energy saving technologies. Hawaii has many energy challenges, making this location an excellent testbed for these activities. Under this project, spray foam technology was applied at military housing on Oahu and the consumption data collected. A cost benefit and operational analysis of the foam was completed. The second phase of this project included design, integration, and analysis of photovoltaic systems at a military community on Oahu. This phase of the project was conducted as part of Forest City's second Solar America Showcase Award.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An evaluation of the ERTS data collection system as a potential operational tool

The Earth Resources Technology Satellite Data Collection System has been shown to be, from the users vantage point, a reliable and simple system for collecting data from U.S. Geological Survey operational field instrumentation. It is technically feasible to expand the ERTS system into an operational polar-orbiting data collection system to gather data from the Geological Survey's Hydrologic Data Network. This could permit more efficient internal management of the Network, and could enable the Geological Survey to make data available to cooperating agencies in near-real time. The Geological Survey is conducting an analysis of the costs and benefits of satellite data-relay systems.

Paulson, R. W.↗

Hierarchical Cluster Analysis of Service Usage and Geographic Variation in Medicare Spending

Per capita Medicare spending varies considerably throughout the Unites States, even after taking into account factors such as cost of living and pre-existing conditions of the Medicare populations. Additionally, per capita spending may vary up to four times as much under Medicare as it does under private insurance. Several studies have explored the Medicare-costs differences between regions with respect to how Medicare services are used. The recent public release of a large, relatively fine-grained set of Medicare data over four annual periods (2007–2010) by the Centers for Medicare and Medicaid Services (CMS), allowed us to perform a broad-scale exploratory analysis of Medicare service-usage patterns. The CMS data set contains data on the Health Care Referral Region level, which subsets the United States into 306 distinct regions. To identify potential trends in service usage over these regions, we used hierarchical agglomerative cluster analysis (HACA) to group regions into clusters based on similarity of service-usage patterns. Much previous work on the subject of cost variation starts with analysis of cost. By beginning with service-usage data, HACA effectively uncoupled patterns of service-usage from overall patterns of cost. We found that while some Medicare services were used in a fairly consistent manner over all clusters, other services varied considerably. Variation in how frequently services are used may provide insight into practices that are particularly expensive or particularly cost effective. It also may be possible to develop recommendations for more cost-efficient high-quality medical care by taking such information into account. In addition, the variance among the frequencies with which some services are used may point to inconsistent standards of medical practice that are not necessarily directly reflected in total cost, or to more deeply underlying geographic or demographic factors that are not necessarily reflected directly in total cost.

Vacha, Linnet↗

System Integration of Rationally Designed Dilute Alloy Catalysts for Energy-Efficient Electrochemical CO 2 -To-Fuel Conversion

Energy effiecient electrochemical conversion of CO 2 to high-demand chemicals and transportation fuels using renewable solar and wind energy is a key technology needed for a high-productivity, low-carbon future. However, the development of scalable, low-cost, active, selective, and stable electrocatalysts remains a key challenge that needs to be overcome to enable high-volume conversion of CO 2 to feedstock chemicals for the chemical industry. In previous work, Lawrence Livermore National Laboratory (LLNL) has developed a rational design platform for dilute alloy transition metal electrocatalysts that promise to make electrochemical CO 2 conversion more energy efficient and selective. In this project, we worked with our industrial partners, Twelve and TotalEnergies, to improve scale up, integration, and stability of LLNL’s dilute alloy catalyst technology into an industry-relevant zero gap electrolyzer platform. Through virtual experiments and data analysis, we designed efficient and cost-effective copper-based catalysts. The catalyst was specifically designed to streamline the slowest and most energy-intensive step of the electrochemical chemical transformation of CO 2 to multi-carbon products – that is making the carbon-carbon bond by dimerization of the reaction intermediate carbon monoxide - resulting in up to 10% improvement in energy efficiency for C 2 products while simultaneously increasing the selectivity towards C 2 products. We tested two different scalable catalyst coating technologies and down-selected magnetron sputtering as the technique that provided the best control over catalyst loading, composition, and morphology. Using this technology, we successfully demonstrated integration of our dilute alloy catalysts into a 100 cm 2 electrolyzer platform with Faradaic efficiencies for ethylene production reaching 40% at a current density of 200 mA/cm 2 . We also developed the technology to integrate a well-defined nanoscale porosity by depositing alloy compositions that were compatible with dealloying, that is, selective leaching of an alloy component to generate nanoscale porosity. We observed that integration of the dealloying-derived nanoporosity improved catalyst performance and stability by leading to a more hydrophobic catalyst/anion exchange membrane interface. Unsolved problems that still need to be addressed are corrosion of the Cu catalyst -specifically if the used catalyst is exposed to air - as well as long term stability do to salt formation/deposition and flooding of the catalyst/electrolyzer flow channels, especially at higher current densities. As we only worked on optimization of catalyst composition, coating thickness, and morphology, further performance optimization will require a system level approach that includes optimization of electrolyzer design and membrane technology.

36 MATERIALS SCIENCE↗

Utility-Scale Solar 2014. An Empirical Analysis of Project Cost, Performance, and Pricing Trends in the United States

Other than the nine Solar Energy Generation Systems (“SEGS”) parabolic trough projects built in the 1980s, virtually no large-scale or “utility-scale” solar projects – defined here to include any groundmounted photovoltaic (“PV”), concentrating photovoltaic (“CPV”), or concentrating solar thermal power (“CSP”) project larger than 5 MW AC – existed in the United States prior to 2007. By 2012 – just five years later – utility-scale had become the largest sector of the overall PV market in the United States, a distinction that was repeated in both 2013 and 2014 and that is expected to continue for at least the next few years. Over this same short period, CSP also experienced a bit of a renaissance in the United States, with a number of large new parabolic trough and power tower systems – some including thermal storage – achieving commercial operation. With this critical mass of new utility-scale projects now online and in some cases having operated for a number of years (generating not only electricity, but also empirical data that can be mined), the rapidly growing utility-scale sector is ripe for analysis. This report, the third edition in an ongoing annual series, meets this need through in-depth, annually updated, data-driven analysis of not just installed project costs or prices – i.e., the traditional realm of solar economics analyses – but also operating costs, capacity factors, and power purchase agreement (“PPA”) prices from a large sample of utility-scale solar projects in the United States. Given its current dominance in the market, utility-scale PV also dominates much of this report, though data from CPV and CSP projects are presented where appropriate.

14 SOLAR ENERGY↗

NREL Screens Universities for Solar and Battery Storage Potential

In support of the U.S. Department of Energy's SunShot initiative, NREL provided solar photovoltaic (PV) screenings in 2016 and 2017 for universities seeking to go solar. Fifteen universities were selected for screenings based on campus solar and sustainability goals, plans for future solar projects and solar deployment capacity (megawatts), regional diversity, energy costs, and availability of campus energy data for the analysis.

14 SOLAR ENERGY↗

2015 Cost of Wind Energy Review

This report uses representative commercial projects to estimate the levelized cost of energy (LCOE) for both land-based and offshore wind plants in the United States for 2015. Scheduled to be published on an annual basis, the analysis relies on both market and modeled data to maintain an up-to-date understanding of wind generation cost trends and drivers. It is intended to provide insight into current component-level costs and a basis for understanding variability in the LCOE across the industry. Data and tools developed by the National Renewable Energy Laboratory (NREL) are used in this analysis to inform wind technology cost projections, goals, and improvement opportunities.

17 WIND ENERGY↗

NASTRAN benefits analysis. Volume 2: Final technical report

Baseline data are considered for comparisons of the costs and benefits of the NASA structural analysis program and to determine impacts and benefits to current users. To develop this information, questionnaires were mailed to users. Personal and telephone interviews were made to solicit further information. The questions in the questionnaire and in the interview were related to benefits derived from the programs, areas of needed improvement, and applicable usage comments. The collected information was compiled and analyzed. Methodology, analyses, and results are presented. The information is applicable to issues preceding NASTRAN Level 15.

Source record↗

Benchmarking Autonomous Scattering Experiments Illustrated on TAS

With the advancement of artificial intelligence and machine learning methods, autonomous approaches are recognized to have great potential for performing more efficient scattering experiments. In our view, it is crucial for such approaches to provide thorough evidence about respective performance improvements in order to increase acceptance within a scientific community. Therefore, we propose a benchmarking procedure designed as a cost-benefit analysis that is applicable to any scattering method sequentially collecting data during an experiment. For a given approach, the performance assessment is based on how much benefit, given a certain cost budget, it is able to acquire in predefined test cases. Different approaches thus get a chance for comparison and can make their advantages explicit and visible. Key components of the procedure, i.e., cost measures, benefit measures, and test cases, are made precise for the setting of three-axes spectrometry (TAS) as an illustration. Finally, we discuss neglected aspects and possible extensions for the TAS setting and comment on the procedure’s applicability to other scattering methods. A Python implementation of the procedure to simplify its utilization by interested researchers from the field is also provided.

36 MATERIALS SCIENCE↗

Gasification and Techno-Economic Analysis of High-Impact Biomass Feedstocks for the Synthesis of High-Octane Gasoline

Five economically advantaged biomass feedstocks identified in the US Department of Energy's 2016 Billion Ton Study were gasified and the syngas reformed at the bench scale to study the feedstock price-performance relationship. The distribution of reformed syngas compositions, heating values, and yields were similar across the different feedstocks and blends thereof, which ranged from inexpensive residual wastes to more expensive and higher quality biomass, revealing that feedstock performance was mostly insensitive to its price. Custom blended feedstocks produced syngas with characteristics resembling linear combinations of syngas from single-component feedstocks, supporting the ability to customize and predict blended properties based on single-feedstock data. A techno-economic analysis of specific feedstock costs for producing high-octane gasoline showed that miscanthus and forest residues were the most cost-effective with gas yields consistent with experimental gasification data. A field-to-wheels life-cycle assessment of greenhouse gas emissions showed that forest residues was the most environmentally benign feedstock of those studied.

09 BIOMASS FUELS↗

Telemetry Monitoring and Display Using LabVIEW

The Measurement Technology Center of the Instrumentation Section configures automated data acquisition systems to meet the diverse needs of JPL's experimental research community. These systems are based on personal computers or workstations (Apple, IBM/Compatible, Hewlett-Packard, and Sun Microsystems) and often include integrated data analysis, visualization and experiment control functions in addition to data acquisition capabilities. These integrated systems may include sensors, signal conditioning, data acquisition interface cards, software, and a user interface. Graphical programming is used to simplify configuration of such systems. Employment of a graphical programming language is the most important factor in enabling the implementation of data acquisition, analysis, display and visualization systems at low cost. Other important factors are the use of commercial software packages and off-the-shelf data acquisition hardware where possible. Understanding the experimenter's needs is also critical. An interactive approach to user interface construction and training of operators is also important. One application was created as a result of a competative effort between a graphical programming language team and a text-based C language programming team to verify the advantages of using a graphical programming language approach. With approximately eight weeks of funding over a period of three months, the text-based programming team accomplished about 10% of the basic requirements, while the Macintosh/LabVIEW team accomplished about 150%, having gone beyond the original requirements to simulate a telemetry stream and provide utility programs. This application verified that using graphical programming can significantly reduce software development time. As a result of this initial effort, additional follow-on work was awarded to the graphical programming team.

graphical user interface LabVIEW graphical program↗