Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controller”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Reduced Switching Frequency Finite Control Set Model Predictive Control (FCS-MPC) for DFIG

An enhanced Finite Control Set Model Predictive Control (FCS-MPC) strategy with a two-step prediction horizon for a Doubly-Fed Induction Generator (DFIG) is the focus of this paper. The DFIG and RL filter's discrete-time model is used in the proposed control scheme for a two-step prediction horizon of rotor and filter currents for the converter's eight possible switching states. Afterward, the control algorithm selects the ideal switching state, which minimizes currents' objective function. The proposed control scheme does not require a modulation stage for internal controllers. We use Lagrange extrapolations to predict the dynamic changes in currents. The switching frequency reduction is achieved by integrating an optimization constraint in the algorithm's cost function. Furthermore, the Total Harmonic Distortion level of currents is kept below 5%, according to IEEE Std 519-14. Obtained results reveal that the switching frequency of the DFIG converters is considerably reduced without losing control; it is reduced by 13.89KHz for the Grid Side Converter (GSC) and by 1.78KHz for the Rotor Side Converter (RSC).

doubly-fed induction generator↗

Next-Cycle Optimal Fuel Control for Cycle-to-Cycle Variability Reduction in EGR-Diluted Combustion

In this simulation study, cycle-to-cycle fuel control was used to reduce CCV by injecting additional fuel in operating conditions with sporadic misfires and partial burns. An optimal control policy was proposed that utilizes 1) a physics-based model that tracks in-cylinder gas composition and 2) a one-step-ahead prediction of the combustion efficiency based on a kernel density estimator. The optimal solution, however, presents a tradeoff between the reduction in combustion CCV and the increase in fuel injection quantity required to stabilize the charge. Such a tradeoff can be ad- just by a single parameter embedded in the cost function.

Maldonado, BryanP. [Oak Ridge National Lab. (ORNL)↗

A Tutorial on Control-Oriented Modeling and Control of Wind Farms

Wind turbines are often sited together in wind farms as it is economically advantageous. However, the wake inevitably created by every turbine will lead to a time-varying interaction between the individual turbines. Common practice in industry has been to control turbines individually and ignore this interaction while optimizing the power and loads of the individual turbines. However, turbines that are in a wake experience reduced wind speed and increased turbulence, leading to a reduced energy extraction and increased dynamic mechanical loads on the turbine, respectively. Neglecting the dynamic interaction between turbines in control will therefore lead to suboptimal behaviour of the total wind farm. Therefore, wind farm control has been receiving an increasing amount of attention over the past years, with the focus on increasing the total power production and reducing the dynamic loading on the turbines. In this paper, wind farm control-oriented modeling and control concepts are explained. In addition, recent developments and literature are discussed and categorized. This paper can serve as a source of background information and provides many references regarding control-oriented modeling and control of wind farms.

17 WIND ENERGY↗

A Comparative Study of Model Predictive Control and Optimal Causal Control for Heaving Point Absorbers

Efforts by various researchers in recent years to design simple causal control laws that can be applied to WEC devices suggest that these controllers can yield similar levels of energy output as those of more complex non-causal controllers. However, most studies were established without adequately considering device and power conversion system constraints which are relevant design drivers from a cost and economic point of view. It is therefore imperative to understand the benefits of MPC compared to causal control from a performance and constraint handling perspective. In this paper, we compare linear MPC to a casual controller that incorporates constraint handling to benchmark its performance on a one DoF heaving point absorber in a range of wave conditions. Our analysis demonstrates that MPC provides significant performance advantages compared to an optimized causal controller, particularly if significant constraints on device motion and/or forces are imposed. We further demonstrate that distinct control performance regions can be established that correlate well with classical point absorber and volumetric limits of the wave energy conversion device.

42 ENGINEERING↗

Towards intelligent emergency control for large-scale power systems: Convergence of learning, physics, computing and control

Here, this paper has delved into the pressing need for intelligent emergency control in large-scale power systems, which are experiencing significant transformations and are operating closer to their limits with more uncertainties. Learning-based control methods are promising and have shown effectiveness for intelligent power system control. However, when they are applied to large-scale power systems, there are multifaceted challenges such as scalability, adaptiveness, and security posed by the complex power system landscape, which demand comprehensive solutions. The paper first proposes and instantiates a convergence framework for integrating power systems physics, machine learning, advanced computing, and grid control to realize intelligent grid control at a large scale. Our developed methods and platform based on the convergence framework have been applied to a large (more than 3000 buses) Texas power system, and tested with 56 000 scenarios. Our work achieved a 26% reduction in load shedding on average and outperformed existing rule-based control in 99.7% of the test scenarios. The results demonstrated the potential of the proposed convergence framework and DRL-based intelligent control for the future grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nowcasting, predictive control, and feedback control for temperature regulation in a novel hybrid solar-electric reactor for continuous solar-thermal chemical processing

A novel 15 kW reactor for the hybridization of concentrated solar and conventional electric heat was fabricated for renewable and continuous chemical processing at temperatures up to 1700 °C. Solar-electric controllers based on feedback or predictive linear models were used to regulate the device at 925 °C for the production of syngas via the gasification of carbon. The system was challenged with cloud transients programmed on a 45 kW high-flux solar simulator that approximated weather observed in the San Luis Valley (Colorado, USA). In experiment it was found that model predictive control with a 1 min ahead nowcast of incipient clouding best regulated solar-electric reactor temperatures, potentially averting thermal fatigue. Upon clouding, model predictive control with a nowcast yielded temperature disturbances of ±10 °C, whereas feedback control alone featured ±25 °C excursions. Overall, the performance of model predictive control with a nowcast was 75% better than feedback as indicated by the integral squared error of temperature excursion residuals. The importance of nowcast accuracy was explored, and although the model-based controller was robust to forecast amplitude inaccuracy, temporal forecast inaccuracy wholly negated the benefits of predictive control.

14 SOLAR ENERGY↗

Diesel Generator Controller Evaluation via Controller-Hardware-in-the-Loop for Various Microgrid Operation Modes

This paper presents the Controller-Hardware-in-the-Loop (CHIL) evaluation of a diesel generator controller for various microgrid operation modes. The model of the diesel generator (governor, exciter, and primary control) is simulated in real time, and the secondary control is implemented in a real hardware controller, Woodward easYgen, which is tested via CHIL with different microgrid configurations under microgrid transition operations. The experimental results demonstrate that the control settings and configuration of the Woodward controller work correctly for different microgrids under microgrid transition operations, which provides confidence for site commissioning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Evaluation of Data-Enhanced Hierarchical Control for Grid Operations

This paper presents a hardware-in-the-loop (HIL) simulation to evaluate the performance of voltage regulation of Data-Enhanced Hierarchical Control (DEHC). This DEHC uses an advanced distribution management system (ADMS) for grid operations to control legacy and grid-edge devices and coordinate with distributed energy management systems (DERMS) to manage high penetrations of photovoltaics (PV) on a utility distribution system. The HIL platform provides realistic laboratory testing, including accurate modeling (legacy devices, grid-edge devices, and PV) of the real-world distribution system from a utility partner, a real controller (ADMS), software controller DERMS, hardware grid-edge devices, and standard communications protocols. The test results demonstrate functionalities of the integrated platform and the performance of voltage regulation of the coordinated control systems. Based on laboratory testing, the utility can set up the same grid-automation system to manage DERs, legacy devices, and grid-edge devices to achieve their system-level control and operation objectives (e.g., voltage regulation), thus de-risking potential issues such as instability for field deployment.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Per-Phase Control for CHB Converters with Negative-Sequence Current and DC Voltage Balancing Control

This paper presents a per-phase controller for a grid-connected Cascaded H-Bridge (CHB) converter featuring negative sequence current regulation and DC bus voltage balancing capabilities. Unlike conventional three-phase controllers, each phase of the CHB can be separately and controlled to regulate the DC voltage and reactive power flow. per-phase negative sequence current control strategy is incorporated into the proposed controller to ensure compliance with IEEE Standard 2800-2022, which requires the absorption of negative-sequence reactive current during grid voltage disturbances. Furthermore, a feed-forward control-based DC bus voltage balancing method is employed, which eliminates the need for the integrator commonly used in traditional approaches. The performance of the proposed controller is validated under various unbalanced grid scenarios and DC bus voltage imbalances through electromagnetic transient (EMT) simulation using a three-phase, three-level grid-connected CHB–Dual Active Bridge (DAB) converter testbed developed on MATLAB/Simulink. Additionally, the performance of the negative-sequence current regulation is investigated through simulation under different unbalanced grid voltage scenarios.

negative sequence current↗

Model predictive control for integrated control of air-conditioning and mechanical ventilation, lighting and shading systems

Modern buildings are increasingly automated and often equipped with multiple building services (e.g., air-conditioning and mechanical ventilation (ACMV), dynamic shading, dimmable lighting). These systems are conventionally controlled individually without considering their interactions, affecting the building’s overall energy inefficiency and occupant comfort. A model predictive control (MPC) system that features a multi-objective MPC scheme to enable coordinated control of multiple building services for overall optimized energy efficiency, indoor thermal and visual comfort, as well as a hybrid model for predicting indoor visual comfort and lighting power is proposed. The MPC system was implemented in a test facility having two identical, side-by-side experimental cells to facilitate comparison with a building management system (BMS) employing conventional reactive feedback control. The MPC system coordinated the control of the ACMV, dynamic façade and automated dimmable lighting systems in one cell while the BMS controlled the building services in the other cell in a conventional manner. The MPC side achieved 15.1–20.7% electricity consumption reduction, as compared to the BMS side. Simultaneously, the MPC system improved indoor thermal comfort by maintaining the room within the comfortable range (-0.5 < predicted mean vote < 0.5) for 98.3% of the time, up from 91.8% of the time on the BMS side. Visual comfort, measured by indoor daylight glare probability (DGP) and horizontal illuminance level at work plane height, was maintained for the entire test period on the MPC side, improving from having visual comfort for 94.5% and 85.7% of the time, respectively, on the BMS side.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A bi-level advanced control framework for large-scale control of buildings with system-level impact

Increased electricity consumption combined with new forms of generation is testing the reliability of our grid infrastructure. This work describes a method to improve the reliability of the grid through large-scale advanced building control. This paper develops a bi-level distributed control framework to shift the load of 153 buildings to achieve a system-level objective of tracking a power reference signal. This bi-level control is based on the previously-developed ANPV-MPC, a predictive controller that uses a Bayesian neural network to generate an accurate control model and adapt to changing conditions over time. By shifting the building electricity demand to better match the available power, the grid system supplying the buildings is more reliable as evidenced by the analysis of node voltages across an IEEE 13-bus distribution system. The proposed bi-level control framework tracks the system-level power reference with enough accuracy to regulate node voltages across the IEEE 13-bus distribution system within ANSI limits of ±5%. Additionally, the adaptive nature of ANPV-MPC allows each building across the system to adapt to changing conditions, further amplifying the system-level reliability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Reactor Control and Operations (ARCO): A University Research Facility for Developing Optimized Digital Control Rooms

The Advanced Reactor Control and Operations (ARCO) facility was constructed in January 2018 to serve as a test bed for advanced reactor control rooms and operator support systems. Since then, it has supported human-machine interface user experience research, fault detection and mitigation technology development, control room concept of operations development, and remote operations research. ARCO serves as the control room for the Compact Integral Effects Test (CIET) facility, which replicates the primary-side flow paths and thermal-hydraulic behavior of a fluoride-salt-cooled high-temperature reactor (FHR) using simulant fluids and scaling principles. New reactor designs feature different operating conditions and scenarios than those in existing reactors. ARCO supports the research and development of digital tools for operator communications, intuitive real-time data analysis, online health monitoring and prognostics, and control room cybersecurity. By integrating these different technologies, ARCO acts as a prototypical control system to iteratively develop methods and tools of operation in advanced small modular nuclear reactors. This paper describes the features of and challenges to operating advanced small modular reactors underlying the design basis for ARCO and its operator support systems.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Equivalent Circuit Models of Voltage-Controlled Dual Active Bridge Converters: Preprint

In this paper, we introduce a new method of modeling voltage-controlled dual active bridge converters as equivalent circuits. What makes the proposed model unique is that the entire closed loop system converter and control are represented together in one equivalent circuit. Since the full system can be recast as a circuit, this allows for deeper insights on how the closed-loop system performs and for the direct application of circuit analysis techniques. In particular, we reveal how classical control notions can be understood as circuit laws.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Memory forensic analysis of a programmable logic controller in industrial control systems

In industrial control systems (ICS), programmable logic controllers (PLCs) are used to automate physical processes such as nuclear plants and power grid stations, and are often subject to cyber attacks. As in conventional IT domain, the memory analysis of the PLCs can help answer important forensic questions about the attack, such as the presence of malicious firmware, injection of modified control logic (the program running on the PLC), and manipulation of I/O devices (e.g., sensors and actuators). Unlike conventional IT domain, PLCs have heterogeneous hardware architecture, proprietary firmware and control software, making it challenging to employ a unified framework for their memory forensics. For merely extracting artifacts of forensic importance, reverse-engineering the firmware is a tedious task, and the effort needs to be repeated for every PLC model. As a community, a step-wise approach to tackle this challenge is to analyze the memory of specific PLCs, and subsequently find a generic framework applicable to all PLCs. Our work is a step forward in this direction. By following a methodology that focuses on the functional layer of PLCs instead of reverse engineering the firmware, we analyze the digital forensic artifacts available in a common PLC, Allen-Bradley ControlLogix 1756-L61. Before diving into the memory dump, we analyze the PLC control software to create a list of important artifacts that are sure to exist in the PLC memory dump. The approach employs a setup where PLC control software RSLogix-5000 is connected to the PLC, and the memory dump can be obtained as and when needed. We create test cases that sequentially highlight each category of artifacts, followed by an examination of the resultant impact on memory. After attaining the listed artifacts, we employ conventional string and known data searches to extract interesting information present in this PLC's memory. The memory analysis profile, presented as a Python library and shared with the community, can help a forensic investigator to readily extract forensic artifacts from the same model's controller. The adopted approach may help researchers in creating memory profile of other PLCs, and ultimately formulating a generic PLC memory analysis framework.

Rais, Muhammad Haris↗

SEMI-ACTIVE CONTROL FOR TWO-BODY OCEAN WAVE ENERGY CONVERTER BY USING HYBRID MODEL PREDICTIVE CONTROL

Model predictive control (MPC) has been considered as one important feed-forward optimal control strategy for ocean wave energy converter (WEC) targeted on power maximization. The capability of MPC to handle system constraints (ex. stroke, velocity, actuator limitations), and the availability to provide optimal solution for linear system provide potential for the implementation of such algorithm in the WEC control. However, currently, only active MPC control has been introduced for single and two-body WECs. Such control strategy may introduce negative power during the optimization process, since the power take-off (PTO) damping has no constraint. In this paper, we proposed a hybrid MPC strategy in limiting both the PTO damping force and PTO damping to avoid negative power generation during cost function minimization (negative power minimization) for the two-body WEC. The problem is formulated into a quadratic programming (QP) problem targeted at power maximization. However, the standard QP problem formulation cannot be directly applied to the semi-active control problem due to the PTO damping constraints. Therefore, the problem is reformulated as a Mixed-integer Quadratic Programming (MIQP) problem, which contains logical switch to select constraint matrices based on the sign of the relative velocity between the buoy and submerged body. The optimal solution is compared with those of the active MPC control strategy and the passive model with the same irregular wave input.

16 TIDAL AND WAVE POWER↗