Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “continuous quantum measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

EuAuSb: An odd-parity helical variation of altermagnetism

EuAuSb is a triangular-lattice Dirac semimetal in which a topological Hall effect has been observed to develop in association with a magnetically ordered phase. Our single-crystal neutron diffraction measurements have identified an incommensurate helical order in which individual ferromagnetic Eu 2+ layers rotate in-plane by ∼ 120° from one layer to the next. An in-plane magnetic field distorts the incommensurate order, eventually leading to a first order transition to a state that is approximately commensurate and that is continuously polarized as the bulk magnetization approaches saturation. From an analysis of the magnetic diffraction intensities versus field, we find evidence for a dip in the ordered in-plane moment at the same field where the topological Hall effect is a maximum, and we propose that this is due to field-induced quantum spin fluctuations. Our electronic structure calculations yield exchange constants compatible with the helical order and show that the bands near the Fermi level lose their spin degeneracy via a mechanism similar to that in the collinear altermagnets. In conclusion, we find that, unlike the even symmetry seen in the altermagnets, the spin splitting in EuAuSb has odd-wave symmetry similar to that recently found in a number of coplanar magnetic materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

First Experiments and Radiographs on the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) Dense Plasma Focus

We report a dense plasma focus (DPF) is a relatively compact coaxial plasma gun, which completes its discharge as a Z-pinch. These devices are designed to operate at a variety of scales to produce short (<100 ns) pulses of ions, X-rays, and/or neutrons. LLNL recently constructed and brought into operation a new device, the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) DPF, which is designed for radiography and high-yield operations. This device has been commissioned and has achieved neutron yields of up to 3.8E11 neutrons/pulse at 2.5-MA peak current while operating at up to 1 MJ of stored energy in its original pulsed power configuration. MJOLNIR is equipped with a wide range of diagnostics, including nuclear activation detectors, neutron time-of-flight (nToF) detectors, a fast-framing camera, optical light gates, and a time-gated neutron and X-ray imager. LLNL also runs unique particle-in-cell (PIC) simulations of DPF discharges in the Chicago code and has gained significant insight into the various physical factors that influence neutron yield. MJOLNIR is one of the first DPFs whose design and continual upgrades are heavily influenced by model predictions. In this article, we describe insights from modeling, device operation, and recent results. Comparisons between modeling predictions and measurements, as well as X-ray and neutron images are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reexpansion of charged nanoparticle assemblies in concentrated electrolytes

Electrostatic forces in solutions are highly relevant to a variety of fields, ranging from electrochemical energy storage to biology. However, their manifestation in concentrated electrolytes is not fully understood, as exemplified by counterintuitive observations of colloidal stability and long-ranged repulsions in molten salts. Highly charged biomolecules, such as DNA, respond sensitively to ions in dilute solutions. Here, we use non-base-pairing DNA-coated nanoparticles (DNA-NP) to analyze electrostatic interactions in concentrated salt solutions. Despite their negative charge, these conjugates form colloidal crystals in solutions of sufficient divalent cation concentration. We utilize small-angle X-ray scattering (SAXS) to study such DNA-NP assemblies across the full accessible concentration ranges of aqueous CaCl 2 , MgCl 2 , and SrCl 2 solutions. SAXS shows that the crystallinity and phases of the assembled structures vary with cation type. For all tested salts, the aggregates contract with added ions at low salinities and then begin expanding above a cation-dependent threshold salt concentration. Wide-angle X-ray scattering (WAXS) reveals enhanced positional correlations between ions in the solution at high salt concentrations. Complementary molecular dynamics simulations show that these ion–ion interactions reduce the favorability of dense ion configurations within the DNA brushes below that of the bulk solution. Measurements in solutions with lowered permittivity demonstrate a simultaneous increase in ion coupling and decrease in the concentration at which aggregate expansion begins, thus confirming the connection between these phenomena. Our work demonstrates that interactions between charged objects continue to evolve considerably into the high-concentration regime, where classical theories project electrostatics to be of negligible consequence.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance Characterization of UV Science Cameras Developed for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP)

The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras will be built and tested for flight with the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The goal of the CLASP mission is to observe the scattering polarization in Lyman-alpha and to detect the Hanle effect in the line core. Due to the nature of Lyman-alpha polarization in the chromosphere, strict measurement sensitivity requirements are imposed on the CLASP polarimeter and spectrograph systems; science requirements for polarization measurements of Q/I and U/I are 0.1% in the line core. CLASP is a dual-beam spectro-polarimeter, which uses a continuously rotating waveplate as a polarization modulator, while the waveplate motor driver outputs trigger pulses to synchronize the exposures. The CCDs are operated in frame-transfer mode; the trigger pulse initiates the frame transfer, effectively ending the ongoing exposure and starting the next. The strict requirement of 0.1% polarization accuracy is met by using frame-transfer cameras to maximize the duty cycle in order to minimize photon noise. Coating the e2v CCD57-10 512x512 detectors with Lumogen-E coating allows for a relatively high (30%) quantum efficiency at the Lyman-$\alpha$ line. The CLASP cameras were designed to operate with ≤10 e- /pixel/second dark current, ≤ 25 e- read noise, a gain of 2.0 and ≤0.1% residual non-linearity. We present the results of the performance characterization study performed on the CLASP prototype camera; dark current, read noise, camera gain and residual non-linearity.

Champey, Patrick↗

The Beginning and End of the Universe

Cosmology is the scientific study of how the Universe began more than 13 billion years ago, how its properties have changed from that time to the present, and what its eventual fate might be. Observational cosmology uses telescopes like the Hubble to reach back in time to find the faint echoes of the Big Bang. In this lecture, I will give an overview of cosmology, highlighting the very rapid progress this field has made in the last decade, and the role that NASA space telescopes have played and will continue to play in the years to come. I will then focus on two of the most intriguing of those recent discoveries: inflation and dark energy. Our universe began in an extremely rapid accelerated expansion, called inflation, which removed all traces anything that may have existed before, flattened the geometry of space-time, and turned microscopic quantum fluctuations into the largest structures in the universe. At the present time, more than 70% of the mass-energy in the Universe consists of a mysterious substance called dark energy. The dark energy causes the expansion of the Universe to accelerate, and he will discuss the ways that we might be able to measure that acceleration more accurately, revealing the nature of the dark energy and learning the eventual fate of the Universe.

Gardner, Jonathan P.↗

The Beginning and End of the Universe

Cosmology is the scientific study of how the Universe began more than 13 billion years ago, how its properties have changed from that time to the present, and what its eventual fate might be. Observational cosmology uses telescopes like the Hubble to reach back in time to find the faint echoes of the Big Bang. In this lecture, I will give an overview of cosmology, highlighting the very rapid progress this field has made in the last decade, and the role that NASA space telescopes have played and will continue to play in the years to come. I will then focus on two of the most intriguing of those recent discoveries: inflation and dark energy. Our universe began in an extremely rapid accelerated expansion, called inflation, which removed all traces anything that may have existed before, flattened the geometry of space-time, and turned microscopic quantum fluctuations into the largest structures in the universe. At the present time, more than 70% of the mass-energy in the Universe consists of a mysterious substance called dark energy. The dark energy causes the expansion of the Universe to accelerate, and he will discuss the ways that we might be able to measure that acceleration more accurately, revealing the nature of the dark energy and learning the eventual fate of the Universe.

Gardner, Jonathan P.↗

Performance Characterization of UV Science Cameras Developed for the Chromospheric Lyman-Alpha Spectro-Polarimeter

The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras will be built and tested for flight with the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The goal of the CLASP mission is to observe the scattering polarization in Lyman-alpha and to detect the Hanle effect in the line core. Due to the nature of Lyman-alpha polarization in the chromosphere, strict measurement sensitivity requirements are imposed on the CLASP polarimeter and spectrograph systems; science requirements for polarization measurements of Q/I and U/I are 0.1 percent in the line core. CLASP is a dual-beam spectro- polarimeter, which uses a continuously rotating waveplate as a polarization modulator, while the waveplate motor driver outputs trigger pulses to synchronize the exposures. The CCDs are operated in frame-transfer mode; the trigger pulse initiates the frame transfer, effectively ending the ongoing exposure and starting the next. The strict requirement of 0.1 percent polarization accuracy is met by using frame-transfer cameras to maximize the duty cycle in order to minimize photon noise. Coating the e2v CCD57-10 512x512 detectors with Lumogen-E coating allows for a relatively high (30 percent) quantum efficiency at the Lyman-alpha line. The CLASP cameras were designed to operate with a gain of 2.0 +/- 0.5, less than or equal to 25 e- readout noise, less than or equal to 10 e-/second/pixel dark current, and less than 0.1percent residual non-linearity. We present the results of the performance characterization study performed on the CLASP prototype camera; system gain, dark current, read noise, and residual non-linearity.

Champey, Patrick↗

Performance Characterization of UV Science Cameras Developed for the Chromospheric Lyman-Alpha Spectro-Polarimeter

The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras will be built and tested for flight with the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The goal of the CLASP mission is to observe the scattering polarization in Lyman-alpha and to detect the Hanle effect in the line core. Due to the nature of Lyman-alpha polarization in the chromosphere, strict measurement sensitivity requirements are imposed on the CLASP polarimeter and spectrograph systems; science requirements for polarization measurements of Q/I and U/I are 0.1 percent in the line core. CLASP is a dual-beam spectro-polarimeter, which uses a continuously rotating waveplate as a polarization modulator, while the waveplate motor driver outputs trigger pulses to synchronize the exposures. The CCDs are operated in frame-transfer mode; the trigger pulse initiates the frame transfer, effectively ending the ongoing exposure and starting the next. The strict requirement of 0.1 percent polarization accuracy is met by using frame-transfer cameras to maximize the duty cycle in order to minimize photon noise. Coating the e2v CCD57-10 512x512 detectors with Lumogen-E coating allows for a relatively high (30 percent) quantum efficiency at the Lyman-alpha line. The CLASP cameras were designed to operate with 10 e-/pixel/second dark current, 25 e- read noise, a gain of 2.0 +/- 0.5 and 1.0 percent residual non-linearity. We present the results of the performance characterization study performed on the CLASP prototype camera; dark current, read noise, camera gain and residual non-linearity.

Champey, P.↗

Superconducting Detectors Come of Age, or Ready to Leave the Lab

Cryogenically cooled superconducting detectors have become essential tools for a wide range of measurement applications, ranging from quantum limited heterodyne detection in the millimeter range to direct searches for dark matter with superconducting phonon detectors operating at 20 mK. Superconducting detectors have several fundamental and practical advantages which have resulted in their rapid adoption by experimenters. Their excellent performance arises in part from reductions in noise resulting from their low operating temperatures, but unique superconducting properties provide a wide range of mechanisms for detection. For example, the steep dependence of resistance with temperature on the superconductor normal transition provides a sensitive thermometer for calorimetric and bolometric applications. Parametric changes in the properties of superconducting resonators provide a mechanism for high sensitivity detection of submillil.neter photons. From a practical point of view, the use of superconducting detectors has grown rapidly because many of these devices couple well to SQUID amplifiers, which are easily integrated with the detectors. These SQUID-based amplifiers and multiplexers have matured with the detectors; they are convenient to use, and have excellent noise performance. The first generation of fully integrated large-scale superconducting detection systems is now being deployed. Improved understanding of the operation of these detectors, combined with rapidly improving fabrication techniques, is quickly expanding the capability of these detectors. I will review the development and application of superconductor-based detectors, the ultimate limits to their performance, and consider prospects for their future applications. Continued advances promise to enable important new measurements in physics, and with appropriate advances in cryogenic infrastn~cturem, ay result in the use of these detectors in everyday monitoring applications.

Moseley, Samuel H.↗

Revealing short- and long-range Li-ion diffusion in Li 2 MnO 3 from finite-temperature dynamical mean field theory

Li 2 MnO 3 is a key component of Li-excess layered cathodes of the form (1 − x), LiMO 2 + x, Li 2 MnO 3 (M = Mn, Ni, Co, …), yet its role in setting Li-ion transport limitations remains under debate. Here, in this study, we combine DFT+U, finite-temperature DFT+DMFT with a continuous-time quantum Monte Carlo impurity solver, and nudged-elastic-band (NEB) calculations to study Li + migration in paramagnetic Li 2 MnO 3 in the presence of a single Li vacancy. Evaluating DMFT total energies along the DFT+U NEB geometries reveals that dynamical correlations strongly renormalize the lowest-barrier processes, reducing the activation energies to E a = 0.18 eV for the shortest-range hop and E a = 0.50 eV for the next-lowest (transport-controlling) step. The 0.18 eV barrier quantitatively reproduces the short-range activation energy from µ+SR, while the 0.50 eV barrier is consistent with the long-range transport scale extracted from ac-impedance measurements. This single-vacancy, paramagnetic DMFT description thus provides a unified interpretation of local and macroscopic probes without invoking clustered vacancy configurations or strong extrinsic disorder, consistent with nearly stoichiometric Li 2 MnO 3 powders. More broadly, our results highlight finite-temperature dynamical correlations as an essential ingredient for predicting ionic migration energetics in correlated oxide electrodes.

Lee, Alex Taekyung [University of Illinois, Chicag↗

Widely Tunable Mode-Hop-Free External-Cavity Quantum Cascade Laser

The external-cavity quantum cascade laser (EC-QCL) system is based on an optical configuration of the Littrow type. It is a room-temperature, continuous wave, widely tunable, mode-hop-free, mid-infrared, EC-QCL spectroscopic source. It has a single-mode tuning range of 155 cm(exp -1) (approximately equal to 8% of the center wavelength) with a maximum power of 11.1 mW and 182 cm(exp -1) (approximately equal to 15% of the center wavelength), and a maximum power of 50 mW as demonstrated for 5.3 micron and 8.4 micron EC-QCLs, respectively. This technology is particularly suitable for high-resolution spectroscopic applications, multi-species tracegas detection, and spectroscopic measurements of broadband absorbers. Wavelength tuning of EC-QCL spectroscopic source can be implemented by varying three independent parameters of the laser: (1) the optical length of the gain medium (which, in this case, is equivalent to QCL injection current modulation), (2) the length of the EC (which can be independently varied in the Rice EC-QCL setup), and (3) the angle of beam incidence at the diffraction grating (frequency tuning related directly to angular dispersion of the grating). All three mechanisms of frequency tuning have been demonstrated and are required to obtain a true mode-hop-free laser frequency tuning. The precise frequency tuning characteristics of the EC-QCL output have been characterized using a variety of diagnostic tools available at Rice University (e.g., a monochromator, FTIR spectrometer, and a Fabry-Perot spectrometer). Spectroscopic results were compared with available databases (such as HITRAN, PNNL, EPA, and NIST). These enable precision verification of complete spectral parameters of the EC-QCL, such as wavelength, tuning range, tuning characteristics, and line width. The output power of the EC-QCL is determined by the performance of the QC laser chip, its operating conditions, and parameters of the QC laser cavity such as mirror reflectivity or intracavity losses. In order to maximize the output power, an analysis and optimization of the EC laser parameters has been performed. The parameters of the beam emitted from the gain medium, such as divergence angle, beam profile, and astigmatism, have been investigated. The gain medium has been fully characterized before and after each stage of modification. The main modification steps are coating one facet of the gain chip with a high reflectivity mirror and the other facet with an anti-reflection layer. Then the chip is mounted in the EC-QCL. The optomechanical design has been reviewed and improved to provide for precise collimation of the strongly divergent beam of the QCL and the tuning diffraction grating.

Wysocki, Gerard↗

Continuous-wave planar laser induced fluorescence with a fast camera

We present planar, laser induced fluorescence (PLIF) measurements of the velocity-resolved distribution function of ions in a plasma using a modulated, narrow linewidth, continuous-wave laser. Plasma emission is acquired with a high frame rate camera, and the laser light is spread into a thin sheet so that an entire plane of the plasma is imaged at each interrogation wavelength. Fourier analysis is conducted on each pixel of the images to separate the modulated fluorescent emission from the background light. Argon ion temperatures and bulk flow maps are reported in a helicon plasma source, and standard single-point LIF measurements provide validation of the PLIF measurement.

47 OTHER INSTRUMENTATION↗

Study of Dislocation-Ordered In(x)Ga(1-x)As/GaAs Quantum Dots

A report describes an experimental study of dislocation-induced spatial ordering of quantum dots (QDs) comprising nanometer-sized In(x)Ga(1-x)As islands surrounded by GaAs. Metastable heteroepitaxial structures were grown by molecular-beam epitaxy of In(x)Ga(1-x)As onto n+ GaAs and semi-insulating GaAs substrates. Then the structures were relaxed during a post-growth annealing/self-organizing process leading to the formation of surface undulations that acted as preferential sites for the nucleation of QDs. Structural effects of annealing times and temperatures on the strain-relaxed In(x)Ga(1-x)As/GaAs and the subsequent spatial ordering of the QDs were analyzed by atomic-force microscopy and transmission electron microscopy. Continuous-wave spectral and time-resolved photoluminescence (PL) measurements were performed to study the effects, upon optical properties, of increased QD positional ordering, increased QD uniformity, and proximity of QDs to arrays of dislocations. PL spectral peaks of ordered QD structures formed on strain-relaxed In(x)Ga(1-x)As/GaAs layers were found to be narrower than those of structures not so formed and ordered. Rise and decay times of time-resolved PL were found to be lower at lower temperatures -- apparently as a consequence of decreased carrier-transport times within the barriers surrounding the QDs.

Leon, Rose↗

Outlook for active plasma spectroscopy with entangled two-photon absorption

Entangled two-photon absorption (ETPA) exhibits a quantum-enhanced two-photon absorption cross-section and a linear scaling with incident power that exceeds classical two-photon absorption (TPA) at low photon flux. Here, we assess the feasibility and applications of ETPA for active plasma spectroscopy. The ETPA-absorbed power for an Ar + species in a helicon plasma scenario is calculated to be as high as 0.6 nW cm −1 along the incident beam path for nondegenerate-entangled photon pairs that are near-resonant with an intermediate level. The ETPA absorption power exceeds classical TPA and Bremsstrahlung emission, a necessary condition for a feasible fluorescence measurement. Applications of ETPA plasma spectroscopy may include trace impurity detection, ground-state excitation, and continuous-wave pumping for high-bandwidth turbulence measurements. Possible benefits of plasma measurements are less harm to optical components with lower incident flux and reduced stray light that can contaminate optical diagnostics.

active plasma spectroscopy↗

Measurement-induced phase transition in teleportation and wormholes

We demonstrate that some quantum teleportation protocols exhibit measurement induced phase transitions in Sachdev-Ye-Kitaev model. Namely, Kitaev-Yoshida and Gao-Jafferis-Wall protocols have a phase transition if we apply them at a large projection rate or at a large coupling rate respectively. It is well-known that at small rates they allow teleportation to happen only within a small time-window. We show that at large rates, the system goes into a new steady state, where the teleportation can be performed at any moment. In dual Jackiw-Teitelboim gravity these phase transitions correspond to the formation of an eternal traversable wormhole. In the Kitaev-Yoshida case this novel type of wormhole is supported by continuous projections.

Physics↗

Operational processing and cloud boundary detection from micro pulse lidar data

Micro Pulse Lidar (MPL) was developed at NASA Goddard Space Flight Center (GSFC) as the result of research on space-borne lidar techniques. It was designed to provide continuous, unattended observations of all significant atmospheric cloud and aerosol structure with a rugged, compact system design and the benefit of eye safety (Spinhirne 1993). The significant eye safety feature is achieved by using low pulse energies and high pulse repetition rates compared to standard lidar systems. MPL systems use a diode pumped 10 microj, 2500 Hz doubled Nd:YLF laser. In addition, a solid state Geiger mode avalanche photo diode (GAPD) photon counting detector is used allowing for quantum efficiencies approaching 70%. Other design features have previously been noted by Spinhirne (1995). Though a commercially available instrument, with nearly 20 systems operating around the world, the most extensive MPL work has come from those operated by the Atmospheric Radiation Measurement (ARM) (Stokes and Schwartz 1994) program. The diverse ability of the instrument relating to the measurement of basic cloud macrophysical structure and both cloud and aerosol radiative properties well suits the ARM research philosophy. MPL data can be used to yield many parameters including cloud boundary heights to the limit of signal attenuation, cloud scattering cross sections and optical thicknesses, planetary boundary layer heights and aerosol scattering profiles, including those into the stratosphere in nighttime cases (Hlavka et al 1996). System vertical resolution ranges from 30 m to 300 m (i.e. high and low resolution respectively) depending on system design. The lidar research group at GSFC plays an advisory role in the operation, calibration and maintenance of NASA and ARM owned MPL systems. Over the past three years, processing software and system correction techniques have been developed in anticipation of the increasing population of systems amongst the community. Datasets produced by three ARM-owned systems have served as the basis for this development. With two operating at the southern Great Plains Cloud and Radiation Testbed Site (SGP CART) since December 1993 and another at the Manus Island Atmospheric Radiation and Cloud Station (TWP ARCS) location in the tropical western Pacific since February 1997, the ARM archive contains over 4 years of observations. In addition, high resolution systems planning to come on-line at the North Slope, AK CART shortly with another scheduled to follow at the TWP ARCS-II will diversify this archive with more extensive observations.

Campbell, James R.↗

Diverse simulations of time-resolved photoluminescence in thin-film solar cells: A SnO 2 /CdSe y Te 1-y case study

Time-resolved photoluminescence (TRPL) is widely used to measure carrier lifetime in thin-film solar cell absorbers. However, the injection dependence of data and frequent non-exponential decay shapes complicate the interpretation. Here, we develop a numerical model to simulate injection-dependent TRPL measurements in a SnO 2 /CdSe y Te 1-y case study solar cell structure, considering parameters of interest to researchers in industry and academia. Previous simulations have shown that, in low injection, excess electrons and holes injected by the laser pulse are rapidly separated in the electric field formed by the pn junction. As a result, at early times, the PL signal can decay faster than the Shockley-Read-Hall lifetime in the absorber bulk (t_bulk). Prior simulations have shown that the charge stored in the junction can slowly leak out to affect decays at late times. However, it has not been clear if and to what degree charge storage can affect the slopes extracted from TRPL decays - t_2 - commonly cited as the TRPL-measured lifetime. Here, we show that charge storage can, in some cases, result in t_2 values that substantially overestimate t_bulk. Previous simulations indicate that high injection conditions can screen the junction field and minimize charge separation. Here, we show that continued injection increases can drive down t_2 below t_bulk as radiative recombination becomes dominant. We catalog charge storage and radiative recombination impacts for a diverse set of material parameters and compare results to double-heterostructure models.

CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS,S↗

Monte–Carlo ray-tracing studies of multiplexed prismatic graphite analyzers for the cold-neutron triple-axis spectrometer at the High Flux Isotope Reactor

A modern cold triple-axis spectrometer to study quantum condensed matter systems is planned for the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. Here, we describe the conceptual principles and design of a secondary spectrometer using a multiplexed, prismatic analyzer system relying on graphite crystals and inspired by the successful implementation of the Continuous Angle Multiple Energy Analysis (CAMEA) spectrometers at the Paul Scherrer Institute. This project is currently known as MANTA for Multi-Analyzer Neutron Triple-Axis. Here, we report Monte-Carlo ray-tracing simulations on a simple but realistic sample scattering kernel to further illustrate the prismatic analyzer concept’s workings, calibration, and performance. Then, we introduce a new statistical analysis approach based on the prismatic analyzer concept to improve the number of final energies measured on the spectrometer. We also study possible evolutions in the CAMEA design relevant for MANTA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗