Diverse occupancy simulation and presence sensing viability for residential thermal energy regulation: Review and false positive modeling initial findings
Not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
Not provided.
Not provided.
A well‐ventilated room is essential to reduce the risk of airborne transmission. As such, the scientific community sets minimum limits on ventilation with the idea that increased ventilation reduces pathogen concentration and thus reduces the risk of transmission. In contrast, the upper limit on ventilation is usually determined by human comfort and the need to reduce energy consumption. While average pathogen concentration decreases with increased ventilation, local concentration depends on multiple factors and may not follow the same trend, especially within short exposure times over large separation distances. Here, we show through experiments and high‐fidelity simulations the existence of a worst‐case ventilation where local pathogen concentration increases near the receiving host. This occurs during the type of meetings that were recommended during the pandemic (and in some cases solely authorized) with reduced occupancy adhering to social distancing and short exposure times below 20 minutes. We maintain that for cases of high occupancy and long exposure time, increased ventilation remains necessary.
A new Dynamic zOnal Model with Air-diffuser (DOMA) was developed. Several case studies were investigated and tested to evaluate and validate this program using measurement data. This new model was integrated into a TRaNsient SYstems Simulation program library and coupled with the multi-zone thermal model. The DOMA/TRNSYS coupled model was then used to predict room temperature distribution over an entire day of a single-zone building. The results show that increasing the heating outputs of the electric floor system, for example, from 75 to 200 W/m 2 , would not effectively improve the indoor thermal comfort, since the thermostat will reach the set point first and then turn off the system before the room gets enough heat and reach a comfortable level. This indicates the importance of selecting an appropriate location and set point for the thermostat when using a floor heating system. This potential thermal comfort issue can only be identified through the two-node model with a dynamic zonal model rather than the conventional PMV model, which thus suggests that for optimizing indoor thermal comfort of a building equipped with a time-sensitive control strategy and/or HVAC system, the TSENS results obtained from the two-node model integrated with DOMA are more appropriate than PMVs.
Controlling airborne transmission of contaminants including respired viruses such as SARS-CoV-2 is necessary to protect occupants living in the same house with a contagious person. The effectiveness of interventions requiring minor efforts that create a negative pressure isolation zone (IZ) for a contagious person has yet to be systematically tested for residential homes. In this study, ASHRAE Standard 170, which offers guidance for negative pressure isolation space control in healthcare facilities, was used in developing practical and attainable recommendations for residential single-family homes. The relative effectiveness of several control strategies was evaluated through experimentally conducting 17 different test cases in a manufactured single-family house laboratory. These cases were designed based on various heating, ventilation and air-conditioning (HVAC) operating scenarios, intervention measures including closing the IZ door and/or sealing over supply and return air grilles in the IZ, and utilization of bathroom exhaust or portable window fans for pressure control. Four out of 17 test cases were identified as having the potential for strong containment with adequate depressurization in the IZ. The most effective IZ depressurization was achieved through continuously operating the exhaust fan in the bathroom attached to the IZ, by installing a portable window fan that extracted air out of the IZ, and a portable room air conditioner with the AC unit exhaust duct installed in one of the IZ windows.
Not provided.
Not provided.
Not provided.
Not provided.
Not provided.
Abstract Concrete creep research has focused primarily on uniaxial response. However, biaxially prestressed concrete structures are common, resulting in a multiaxial stress state that can complicate the behavior of a viscoelastic material like concrete. Significant creep strains may be induced in directions transverse to each principle stress due to Poisson’s effect. Past research is unclear regarding the viscoelastic or viscoplastic properties of concrete outside of uniaxial response. It has been reported in separate studies that concrete viscoelastic/viscoplastic Poisson’s ratio (VPR) is an increasing, decreasing and constant function with time, with all reported measurements performed at room temperature. In this paper, the 3D basic creep response of mature cement mortar is examined using a confined compression experiment that allows direct determination of the full stress and infinitesimal strain tensors in a single test, which enables the determination of VPR under a multiaxial stress state. For this purpose, a unique, miniature version of the standardized concrete creep frame is designed that is amenable to placing in climate chambers and temperature ovens. The experimental results indicate that the VPR of sealed, mature cement mortar is nearly constant and equal to the elastic at room temperature, while the VPR gradually increases with time when measured at 60 °C.
Digital fabrication methods with concrete have been rapidly developing, with many problems related to component production and material control being solved in recent years. These processes produce inherently layered cementitious components that are anisotropic, and in many cases, produces a weak interface between layers, which are generally referred to as cold joints. While material strength at these interfaces has been well studied in recent years, durability has received less attention, even though cold joints can function as channels for aggressive agents, such as chlorides. This work presents a method using micro-X-ray fluorescence (μXRF) to image chloride ingress into layer interfaces of 3D printed fine-grained concrete specimens produced with varying layer deposition time intervals, and also compares it to neutron imaging of moisture uptake. The results show that cold joints formed after a 1 day time interval are highly susceptible to chloride ingress, and that curing conditions play a major role in how quickly interfacial transport can take place. The μXRF method is also shown to be useful for study of transport of chlorides in cold joints, due to its spatial resolution and direct analysis of an aggressive species of interest.
The main thrust of the work reported herein is to study the effect of chemical additives to make beneficial use of carbon dioxide in enhancing the compressive strength of dry-cast concrete. The additives used in this investigation were calcium and magnesium oxides and silicates, nickel oxide, sodium hydroxide, sodium bicarbonate and strontium chloride. The experimental results showed that both the carbonation reactions and the compressive strength of dry-cast concrete mixtures were improved when using chemical additives. Experimental investigations for optimisation were also undertaken with selected additives to further increase the carbon dioxide uptake and improve the compressive strength. The best results were obtained when using calcium silicate in combination with calcium oxide. The early-age compressive strength of specimens made from the optimised mixture increased from 9·82 MPa to 13·32 MPa, and the specimens’ carbon dioxide uptake increased from 8·76% to 10·62% of cement weight.
In this design and development effort a latent-heat energy storage heat exchanger was designed for a 10MW e sCO 2 power plant as a basis for detailed design and testing of a new phase-change heat exchanger technology. High efficiency thermal conductors of graphite foam or folded copper were employed within chloride salt phase-change volumes bounded by alternating high density compact plate-fin heat exchange cells in this new heat exchanger technology. Test articles were constructed at Brayton Energy and tested at Argonne National Laboratory. Copper-conducting samples were constructed and tested at Brayton Energy.
This study investigates improvements in low-cost latent heat storage material calcium chloride hexahydrate (CaCl2.6H2O). Its melting point is between 25 and 28 °C, with relatively high enthalpy (170–190 J/g); however, this phase change material (PCM) shows supercooling and phase separation. In CaCl2.6H2O incongruent melting causes lower hydrates of CaCl2 to form, which affects the overall energy storage capacity and long-term durability. In this work, PCM performance enhancement was achieved by adding SrCl2.6H2O as a nucleating agent and NaCl/KCl as a stabilizer to prevent supercooling and phase separation, respectively. We investigated the PCM preparation method and optimized the proportions of SrCl2.6H2O and NaCl/KCl. Thermal testing for 25 cycles combined with DSC and T-history testing was performed to observe changes in enthalpy, phase transitions and supercooling over the extended period of usage. X-ray diffraction was used to verify crystalline structure in the compounds. It was found that the addition of 2 wt.% of SrCl2.6H2O reduced supercooling from 12 °C to 0 °C compared to unmodified CaCl2.6H2O. The addition of 5 wt.% NaCl or KCl proved to effectively suppress separation and the melting enthalpy achieved was 169 J/g–178 J/g with congruent melting over 25 cycles, with no supercooling and almost no reduction in the latent heat.
Structural walls in safety-related nuclear facilities are required to be designed for seismic and accident thermal (due to postulated high-energy pipe break events) loading combination. Current U.S. and international codes provide limited guidance for analysis and design of walls for this loading combination. This paper describes the experimental results and observations from tests conducted on a laboratory-scale (1:4 to 1:5) test unit representing steel-plate composite (SC) walls subjected to combined in-plane (seismic) and accident thermal loading. The test unit was subjected to surface temperatures of up to 450°F in combination with cyclic in-plane loading. Results of similar experiments recently conducted in Japan are also summarized (with surface temperatures up to 570°F). Surface heating combined with the low thermal conductivity and high specific heat of concrete resulted in nonlinear thermal gradients through the thickness of the specimens. These nonlinear thermal gradients and the associated self- or internal restraint led to extensive concrete cracking. This concrete cracking reduced the initial and secant stiffness of the specimens. The initial stiffness of the heated specimens reduced to 30 to 40% of the initial stiffness of the control (unheated) specimen. The secant stiffness of the heated specimens reduced up to 50% of the secant stiffness of the control (unheated) specimen. However, the in-plane shear strength of the heated SC specimens was still approximately 10 to 30% greater than the nominal in-plane shear strength calculated, for the limit state of steel plate von Mises yielding, using AISC N690 equations and measured material properties. Evaluation of the experimental results and observations suggests that the in-plane shear strength of SC walls subjected to typical accident surface temperatures (up to 570°F) can be estimated conservatively using the current provisions of AISC N690. The stiffness for accident thermal loading combinations can be considered to reduce from cracked composite stiffness at ambient temperature to fully cracked—that is, steel-only stiffness as the surface temperature increases up to typical accident value.
The United States Department of Energy (DOE) is committed to the advancement of nuclear reactor technology through initiatives such as the Advanced Reactor Development Program (ARDP), to diversify the United States energy portfolio towards more sustainable energy options. The ARDP includes demonstration by industry partners of molten salt fast reactors (MSRs). Construction of molten salt reactor technology requires qualified nuclear structural materials. Unfortunately, there are no current materials that meet current qualification requirements dictated by the Nuclear Regulatory Commission for construction of MSRs. Adapting current structural material qualifications requires expansion of our current knowledgebase on corrosion performance. In this investigation, we assess microstructural changes in a Ni-based superalloy after exposure to a chloride-containing salt system through a correlated multi-modal approach combining several advanced characterization techniques. Namely we will highlight the impact of grain boundary phenomena at the onset of corrosion attack, including the role of intergranular crack propagation and development of internal corrosion products. The findings from this investigation will further expand our assessment of the corrosion performance of structural materials being investigated for construction of MSR components.