Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “consistent filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Novel Coaxial High Pass Filter Design for RF Applications

The complete design of a novel coaxial high pass filter is given analytically and numerically for high power RF applications. The coaxial structure consists of two hollow concentric cylinders with a septum located between them at a single azimuthal angle. This septum provides a good high pass filter characteristics and mechanically holds two hollow cylinders together. The attenuation slope in the stop band with this structure is much sharper than the existing filter configurations. This gives faster transition time from stop band to pass band One end of the coaxial structure is closed and the other end is used as an output port. Excitation port is placed on the side walls of the outside cylinder. The design procedure proposed in this paper has been implemented to obtain a filter configuration at the lower end of the UHF range. The new filter is simulated using 3D electromagnetic simulator, HFSS. It is then constructed and measured. Simulation results are compared with the measured results. Good agreement between simulated and measured results has been observed

42 ENGINEERING↗

Multi‐Species Energy‐Banded Ions in the Ionosphere During the 21 January 2005 Magnetic Storm: Low‐Altitude Edge of the Warm Plasma Cloak

During the 21–22 January 2005 magnetic storm, the FAST satellite observed warm (< few keV) ions in discrete energy bands on the dayside at ∼3,000 km altitude for more than 6.5 hr. We suggest that the ionospheric energy-banded ions represent the low-altitude edge of the warm plasma cloak observed simultaneously by magnetospheric satellites. This is a clear example of the multi-species ion energy bands (10 eV to several keV) observed during strong magnetic storms by the FAST satellite, stretching from the diffuse auroral region to the plasmapause with lifetimes up to 12 hr. The close association of these energy-banded ions with magnetic storms, their broad latitudinal extent, and the presence of multiple ion species in the same energy band, rather than at the same velocity, indicate that this is a distinct phenomenon from other types of energy-banded ions. During the 21–22 January 2005 magnetic storm, the dayside ion energy band structures, centered at 10 eV (H + ), 40 eV (H + and He + ), and 160 eV (H + , He + , and O + ), were consistent with a “time-of-flight and velocity filter” formation process acting on a near-cusp, impulsive outflow of a <200 eV multi-species ion-source population, poleward and in the same hemisphere as FAST. Understanding the sources and dynamics of warm energy-banded ions and their linkage to the warm plasma cloak is important because during superstorms these ions are transported to L values as low as L ∼ 1.2 in the dawn sector, significantly altering the energetics of the mid-latitude ionosphere.

58 GEOSCIENCES↗

Spectrometer for cluster ion beam induced luminescence

A spectrometer to detect the ultra-weak luminescence originated by the collision of cluster ions on the surfaces of solid materials was constructed. This spectrometer consists of 11 photomultipliers with band-pass interference filters that can detect the luminescence within the wavelength ranging from 300 to 700 nm and of a photomultiplier without filter. The calibration of the detection system was performed using the photons emitted from a strontium aluminate fluorescent tape and from a high temperature tungsten filament. Preliminary measurements show the ability of this spectrometer to detect the cluster ion beam induced luminescence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The design of a correlation electron cyclotron emission system on J-TEXT

To study the anomalous transport, a correlation electron cyclotron emission (CECE) was planned to be developed on J-TEXT for electron temperature fluctuation measurement. The spectral decorrelation method was employed for the CECE system. It was developed based on the previous 16-channel electron cyclotron emission system. They shared the optical transmission line and mixer. The CECE part consists of 4 channels. Two fixed frequency narrow band filters were used for two channels and two yttrium iron garnet (YIG) filters for the other two channels. To meet the measuring requirement, some tests have been taken for the YIG filters. The results show good performance of the filters. Gaussian optics is used to produce a good poloidal resolution. Wavenumbers resolved by the CECE diagnostic are k{sub θ} ≤ 1.5 rad/cm and k{sub r} ≤ 12 rad/cm. Some preliminary experiment results are also presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interband cascade light-emitting diodes grown on silicon substrates using GaSb buffer layer

Interband cascade light-emitting diodes (ICLEDs) offer attractive advantages for infrared applications, which would greatly expand if high-quality growth on silicon substrates could be achieved. Here, this work describes the formation of threading dislocations in ICLEDs grown monolithically on GaSb-on-Silicon wafers. The epitaxial growth is done in two stages: the GaSb-on-Silicon buffer is grown first, followed by the ICLED growth. The buffer growth involves the nucleation of a 10-nm-thick AlSb buffer layer on the silicon surface, followed by the GaSb growth. The AlSb nucleation layer promotes the formation of 90° and 60° interfacial misfit dislocations, resulting in a highly planar morphology for subsequent GaSb growth that is almost 100% relaxed. The resulting GaSb buffer for growth of the ICLED has a threading dislocation density of ~10 7 /cm 2 after ~3 μm of growth. The fabricated LEDs showed variations in device performance, with some devices demonstrating comparable light–current–voltage curves to those for devices grown on GaSb substrates, while other devices showed somewhat reduced relative performance. Cross-sectional transmission electron microscopy observations of the inferior diodes indicated that the multiplication of threading dislocations in the active region had most likely caused the increased leakage current and lower output power. Enhanced defect filter layers on the GaSb/Si substrates should provide more consistent diode performance and a viable future growth approach for antimonide-based ICLEDs and other infrared devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nontoxic nanopore electroporation for effective intracellular delivery of biological macromolecules

We present a simple nanopore-electroporation (NanoEP) platform for delivery of nucleic acids, functional protein, and Cas9 single-guide RNA ribonucleoproteins into both adherent and suspension cells with up to 80% delivery efficiency and >95% cell viability. Low-voltage electric pulses permeabilize a small area of cell membrane as a cell comes into close contact with the nanopores. The biomolecule cargo is then electrophoretically drawn into the cells through the nanopores. In addition to high-performance delivery with low cell toxicity, the NanoEP system does not require specialized buffers, expensive materials, complicated fabrication processes, or cell manipulation; it simply consists of a generic nanopore-embedded water-filter membrane and a low-voltage square-wave generator. Ultimately, the NanoEP platform offers an effective and flexible method for universal intracellular delivery.

59 BASIC BIOLOGICAL SCIENCES↗

The CMS High Level Trigger System: Experience and future development

The CMS experiment at the LHC features a two-level trigger system. Events accepted by the first level trigger, at a maximum rate of 100 kHz, are read out by the Data Acquisition system (DAQ), and subsequently assembled in memory in a farm of computers running a software high-level trigger (HLT), which selects interesting events for offline storage and analysis at a rate of order few hundred Hz. The HLT algorithms consist of sequences of offline-style reconstruction and filtering modules, executed on a farm of 0(10000) CPU cores built from commodity hardware. Experience from the operation of the HLT system in the collider run 2010/2011 is reported. The current architecture of the CMS HLT, its integration with the CMS reconstruction framework and the CMS DAQ, are discussed in the light of future development. The possible short- and medium-term evolution of the HLT software infrastructure to support extensions of the HLT computing power, and to address remaining performance and maintenance issues, are discussed.

Bauer, G.↗

Dose reduction using a dynamic, piecewise-linear attenuator

Purpose: The authors recently proposed a dynamic, prepatient x-ray attenuator capable of producing a piecewise-linear attenuation profile customized to each patient and viewing angle. This attenuator was intended to reduce scatter-to-primary ratio (SPR), dynamic range, and dose by redistributing flux. In this work the authors tested the ability of the attenuator to reduce dose and SPR in simulations. Methods: The authors selected four clinical applications, including routine full field-of-view scans of the thorax and abdomen, and targeted reconstruction tasks for an abdominal aortic aneurysm and the pancreas. Raw data were estimated by forward projection of the image volume datasets. The dynamic attenuator was controlled to reduce dose while maintaining peak variance by solving a convex optimization problem, assuminga priori knowledge of the patient anatomy. In targeted reconstruction tasks, the noise in specific regions was given increased weighting. A system with a standard attenuator (or “bowtie filter”) was used as a reference, and used either convex optimized tube current modulation (TCM) or a standard TCM heuristic. The noise of the scan was determined analytically while the dose was estimated using Monte Carlo simulations. Scatter was also estimated using Monte Carlo simulations. The sensitivity of the dynamic attenuator to patient centering was also examined by shifting the abdomen in 2 cm intervals. Results: Compared to a reference system with optimized TCM, use of the dynamic attenuator reduced dose by about 30% in routine scans and 50% in targeted scans. Compared to the TCM heuristics which are typically used withouta priori knowledge, the dose reduction is about 50% for routine scans. The dynamic attenuator gives the ability to redistribute noise and variance and produces more uniform noise profiles than systems with a conventional bowtie filter. The SPR was also modestly reduced by 10% in the thorax and 24% in the abdomen. Imaging with the dynamic attenuator was relatively insensitive to patient centering, showing a 17% increase in peak variance for a 6 cm shift of the abdomen, instead of an 82% increase in peak variance for a fixed bowtie filter. Conclusions: A dynamic prepatient x-ray attenuator consisting of multiple wedges is capable of achieving substantial dose reductions and modest SPR reductions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Neptunium Oxide Precipitation Kinetics in Aqueous Systems at Elevated Temperatures, Part I: Colloidal, Temperature, Inert Atmosphere, and Ionic Strength Measurements

We evaluate the proposed NpO 2 + (aq)-NpO 2 (cr) reduction-precipitation system at elevated temperatures to obtain primary information on the effects of temperature, ionic strength, O 2 and CO 2 . Experiments conducted on unfiltered solutions at 10 -4 M NpO 2 + (aq), neutral pH, and 200°C indicated that solution colloids strongly affect precipitation kinetics. Subsequent experiments on filtered solutions at 200, 212, and 225°C showed consistent and distinctive temperature-dependent behavior at reaction times ≤ 800 hours. At longer times, the 200°C experiments showed unexpected dissolution of neptunium solids, but experiments at 212°C and 225°C demonstrated quasi steady-state neptunium concentrations of 3 x 10 -6 M and 6 x 10 -6 M, respectively. Solids from a representative experiment analyzed by X-ray diffraction were consistent with NpO 2 (cr). A 200°C experiment with a NaCl concentration of 0.05 M showed a dramatic increase in the rate of neptunium loss. A 200°C experiment in an argon atmosphere resulted in nearly complete loss of aqueous neptunium. Previously proposed NpO 2 + (aq)-NpO 2 (cr) reduction-precipitation mechanisms in the literature specified a 1:1 ratio of neptunium loss and H + production in solution over time. However, all experiments demonstrated ratios of approximately 0.4 to 0.5. Carbonate equilibria can account for only about 40% of this discrepancy, leaving an unexpected deficit in H + production that suggests that additional chemical processes are occurring.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reducing Exposures to Airborne Particles Through Improved Filtration: A High-Level Modeling Analysis

Indoor airborne particulates are well-known health hazards and filtration is one common method of reducing exposures. Based on our previously developed Regional Shelter Analysis methodology and parameters that characterize the existing US building stock, we perform a high-level assessment of the potential benefits of upgrading existing filters in furnace and in heating, ventilation, and air conditioning systems using off-the-shelf filters. We use three metrics to assess the improvement: Building Transmission Factor (a measure of protection against outdoor airborne particles), Indoor Normalized Time and Space Integrated Air Concentration (a measure of indoor exposure to indoor-origin airborne particles), and Building Exit Fraction (fraction of indoor airborne particles that are released to the outdoor atmosphere). We also discuss the potential reduction in regional exposures due to particles exiting the building and exposing downwind building occupants. Our modeling indicates that while buildings provide their occupants passive protection against airborne particulate hazards, including but not limited to PM 2.5 , PM 10 , and wildfire smoke; improving particle filtration efficiency may further improve this protection. The degree of improvement varies with particle size and building type. Of the building types studied, apartments are predicted to benefit most, with greater than a factor of 2 improvement (≥50% reduction in exposures) for 1 µm particle exposures when using MERV 7 to 12 rated filters. Non-residential buildings were notably less responsive to improved filtration but had the highest Building Exit Fractions with 30% to 40% of indoor airborne particles released to the outdoor atmosphere (apartment buildings only released 6% to 9%). Improvements predicted for single family homes were intermediate between apartments and non-residential buildings. Improvements in the Regional Exposure metric are larger, ranging from a factor of 2.5x to 10x for residences (when using MERV 7 to 12 rated filters) and up to 25x for large apartments with MERV 14 or 15 rated filters. The results of our modeling analysis are broadly consistent with the limited experimental data and modeling results available in the literature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detecting Long-period Variability in the SDSS Stripe 82 Standards Catalog

We report the results of a search for long-period (100 < P < 600 days) periodic variability in the SDSS Stripe 82 standards catalog. The SDSS coverage of Stripe 82 enables such a search because there are on average 20 observations per band in ugriz bands for about one million sources, collected over about 6 yr, with a faint limit of r ~ 22 mag and precisely calibrated 1%–2% photometry. We calculated the periods of variable source candidates in this sample using the Lomb–Scargle periodogram and considered the three highest periodogram peaks in each of the gri filters as relevant. Only those sources with gri periods consistent within 0.1% were later studied. We use the Kuiper statistic to ensure uniform distribution of data points in phased light curves. We present five sources with the spectra consistent with quasar spectra and plausible periodic variability. This SDSS-based search bodes well for future sensitive large-area surveys, such as the Rubin Observatory Legacy Survey of Space and Time, which, due to its larger sky coverage (about a factor of 60) and improved sensitivity (~2 mag), will be more powerful for finding such sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Climatology of aerosol properties at an atmospheric monitoring site on the northern California coast

Between April 2002 and June 2017, the Global Monitoring Laboratory (GML) of the National Oceanic and Atmospheric Administration (NOAA) made continuous measurements of a suite of in situ aerosol optical properties at a long-term monitoring site near Trinidad Head (THD), California. In addition to aerosol optical properties, between 2002–2006 a scanning humidograph system was operated, and inorganic ion and total aerosol mass concentrations were obtained from filter measurements. A combined analysis of these datasets demonstrates consistent patterns in aerosol climatology and highlights changes in sources throughout the year. THD is predictably dominated by sea salt aerosols; however, marine biogenic aerosols are the largest contributor to PM1 in the warmer months. Additionally, a persistent combustion source appears in the winter, likely a result of wintertime home heating. While the influences of local anthropogenic sources from vehicular and marine traffic are visible in the optical aerosol data, their influence is largely dictated by the wind direction at the site. Comparison of the THD aerosol climatology to that reported for other marine sites shows that the location is representative of clean marine measurements, even with the periodic influence of anthropogenic sources.

54 ENVIRONMENTAL SCIENCES↗

High Semi-Volatile Organic Aerosol Contributions Associated with Ammonium Nitrate in the Coastal Urban Environment

Organic components often contribute 50% or more of the submicron aerosol mass in coastal urban environments, but their partitioning between the gas and particle phases is controlled by a complex mixture of unidentified organic compounds that are poorly constrained by observations. This study compares daily filter organic functional groups (OFG) with online organic mass fragments from La Jolla, California, as part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), quantifying the contributions of four types of non-volatile (NV) organic emission sources to the submicron composition. Daily filters retained only 0.79–0.98 µg/m3 NV submicron organic mass concentration, even though 1.8–1.9 µg/m3 non-refractory (NR) submicron organic mass concentration was measured online. The 62–64% of measured NR submicron organic mass concentration that exceeded what remained on the filters after 23-hr sampling is interpreted as semi-volatile, consistent with the moderate correlation of the NR NV difference to NR ammonium, NR nitrate, and biomass burning-related NV and NR organic factors. The association between semi-volatile organic components and ammonium nitrate likely results from both co-emission and co-evaporation. Size-resolved filter analysis showed that NV organic mass concentration accounts for 68% of NR organic mass concentration for 0.5–1 µm dry diameter but account for 9.0% for 0.18–0.5 µm dry diameter showing the differences in volatility between particle modes. Importantly, volatility of organic components was size-dependent Information Classification: General and associated with ammonium nitrate and biomass burning, providing guidance for constraining atmospheric aerosol properties in global models.

Pelayo, Christian↗

HD100546 multi-epoch scattered light observations

We present H, K{sub s}, and L' filter polarimetric differential imaging (PDI) data for the transitional disk around HD100546 obtained in 2013, together with an improved re-reduction of previously published 2006 data. We reveal the disk in polarized scattered light in all three filters, achieving an inner working angle of ∼0.''1. Additional, short-exposure observations in the H and K{sub s} filters probe the surroundings of the star down to ∼0.''03 (∼3 AU). HD100546 is fascinating because of its variety of sub-structures possibly related to forming planets in the disk, and PDI is currently the best technique for imaging them in the near-IR. For the first time ever, we detect a disk in L-band PDI data, and we constrain the outer radius of the inner hole to 14 ± 2 AU and its eccentricity to <0.133. A dark lane is detected between ∼0.''2-0.''6 AU in the front side of the disk, which is likely an effect of the scattering angle and the scattering function of the grains. We find a spiral arm in the northeast that has no obvious connection to spiral arms seen before by other authors further out in the disk, but winds are in the same direction (clockwise). The two bright scattering peaks along the semi-major axis are asymmetric, with the southeastern one being significantly brighter. This could be related to the inner companion candidate that is close to the brighter side of the disk at the time of the observations. The scattering color is close to gray between the H and K{sub s} filters ([H]–[K{sub s}] = 0.19 ± 0.11), but the scattering in the L' filter is significantly weaker ([H]–[L'] = –1.08 ± 0.35, [K{sub s}]–[L'] = –1.27 ± 0.35). We measure the position angle of the disk to be 138° ± 3°, consistent with previous observations, and we derive the dust scattering function in the H and K{sub s} filters between ∼35° and ∼130° at two different radii (30-50 and 80-110 AU) and show that our results are consistent with a disk that is more strongly flared in the outer regions.

79 ASTRONOMY AND ASTROPHYSICS↗

Invited Article: Narrowband terahertz bandpass filters employing stacked bilayer metasurface antireflection structures

We experimentally demonstrate high-performance narrowband terahertz (THz) bandpass filters through cascading multiple bilayer metasurface antireflection structures. Each bilayer metasurface, consisting of a square array of silicon pillars with a self-aligned top gold resonator-array and a complementary bottom gold slot-array, enables near-zero reflection and simultaneously close-to-unity single-band transmission at designed operational frequencies in the THz spectral region. The THz bandpass filters based on stacked bilayer metasurfaces allow a fairly narrow, high-transmission passband, and a fast roll-off to an extremely clean background outside the passband, thereby providing superior bandpass performance. The demonstrated scheme of narrowband THz bandpass filtering is of great importance for a variety of applications where spectrally clean, high THz transmission over a narrow bandwidth is desired, such as THz spectroscopy and imaging, molecular detection and monitoring, security screening, and THz wireless communications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Two-Level Chebyshev Filter Based Complementary Subspace Method: Pushing the Envelope of Large-Scale Electronic Structure Calculations

We describe here a novel iterative strategy for Kohn–Sham density functional theory calculations aimed at large systems (>1,000 electrons), applicable to metals and insulators alike. In lieu of explicit diagonalization of the Kohn–Sham Hamiltonian on every self-consistent field (SCF) iteration, we employ a two-level Chebyshev polynomial filter based complementary subspace strategy to (1) compute a set of vectors that span the occupied subspace of the Hamiltonian; (2) reduce subspace diagonalization to just partially occupied states; and (3) obtain those states in an efficient, scalable manner via an inner Chebyshev filter iteration. By reducing the necessary computation to just partially occupied states and obtaining these through an inner Chebyshev iteration, our approach reduces the cost of large metallic calculations significantly, while eliminating subspace diagonalization for insulating systems altogether. We describe the implementation of the method within the framework of the discontinuous Galerkin (DG) electronic structure method and show that this results in a computational scheme that can effectively tackle bulk and nano systems containing tens of thousands of electrons, with chemical accuracy, within a few minutes or less of wall clock time per SCF iteration on large-scale computing platforms. We anticipate that our method will be instrumental in pushing the envelope of large-scale ab initio molecular dynamics. As a demonstration of this, we simulate a bulk silicon system containing 8,000 atoms at finite temperature, and obtain an average SCF step wall time of 51 s on 34,560 processors; thus allowing us to carry out 1.0 ps of ab initio molecular dynamics in approximately 28 h (of wall time).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Difficult Removal of Retrievable IVC Filters: A Description of the 'Double-Wire Restraining' Technique

We describe our experience with the use of the 'double-wire restraining' technique to assist in the removal of two retrievable inferior vena cava filters: one had been misplaced in the right brachiocephalic vein with apex perforation of the vessel wall, and the second filter had migrated cephalad to straddle across both renal veins. The 'double-wire restraining' technique consists of two stiff-shaft Glidewires (Terumo, Somerset, NJ) placed through the same introducer sheath and positioned on opposite sides of the filter. Both wires restrain the filter at the tip of the sheath as the sheath is advanced, thus allowing the operator to reposition the filter. This report details how this technique was used to realign two malpositioned filters and reposition the filter apices from their extravascular location, thus exposing them for ensnarement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exploration of Optimization Options for Increasing Performance of a GPU Implementation of a Three-dimensional Bilateral Filter

This report explores using GPUs as a platform for performing high performance medical image data processing, specifically smoothing using a 3D bilateral filter, which performs anisotropic, edge-preserving smoothing. The algorithm consists of a running a specialized 3D convolution kernel over a source volume to produce an output volume. Overall, our objective is to understand what algorithmic design choices and configuration options lead to optimal performance of this algorithm on the GPU. We explore the performance impact of using different memory access patterns, of using different types of device/on-chip memories, of using strictly aligned and unaligned memory, and of varying the size/shape of thread blocks. Our results reveal optimal configuration parameters for our algorithm when executed sample 3D medical data set, and show performance gains ranging from 30x to over 200x as compared to a single-threaded CPU implementation.

97 MATHEMATICS AND COMPUTING↗