Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “confidence measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Measurement of neutral gadolinium oscillator strengths using dual-comb absorption spectroscopy in laser-produced plasmas

The oscillator strengths of 43 transitions of neutral gadolinium from 530 to 535 nm were determined based on high-resolution absorption spectra measured by probing a laser-produced plasma (LPP) using time-resolved dual-comb spectroscopy (DCS). Absorption spectra were measured at various time delays, ranging from 33 to 252 µs after the onset of the plasma formation, over which the temperature and number density varied as the ablation plume evolved. A Boltzmann analysis was used to determine the excitation temperature and column density of Gd in the ablation plume, based on measured absorption from 20 Gd I spectral lines with known oscillator strengths. Oscillator strengths were then determined for additional dipole-allowed Gd I transitions identified in the absorption spectra, 19 of which were previously unreported. Oscillator strengths of all measured transitions were compared with literature values when available and show good agreement in most cases. Time-resolved measurement of atomic absorption in the cooling plasma provides access to a range of excitation temperatures and optical densities for the atoms in the ablation plume, allowing repeated measurements under different conditions, thereby improving confidence in the results. The high spectral bandwidth and resolution capabilities of DCS make it well-suited to measuring the dense optical spectrum of Gd, and the technique is applicable to other elements, especially lanthanides and actinides.

(280.4788) Optical Sensing, (280.5395) Plasma Diag↗

Quantitative water quality with LANDSAT and Skylab

Correlation studies were completed between LANDSAT Multispectral Scanner (MSS) band ratios derived from computer compatible tape (CCT) and 170 water samples taken from three large Kansas reservoirs, coincident with 16 different LANDSAT passes over a 13 month period. The following conclusions were obtained: (1) LANDSAT MSS reflectance levels are useful for quantitative measurement of suspended solids up to at least 900 ppm, (2) MSS band ratios derived from CCT can measure suspended solids with 67% confidence level accuracy of 12 ppm over the range 0-80 ppm and 35 ppm over the range 0900 ppm, (3) suspended solids contour maps can be easily constructed from CCT for water bodies larger than approximately 100 acres, (4) rationing suppresses MSS reflectance level dependence on seasonal sun angle variation and permits measurement of suspended load the year round in the middle latitudes. SKYLAB imagery from a single pass over three reservoirs compares favorably to LANDSAT results up to 100 ppm.

Yarger, H. L.↗

Hypersonic Boundary Layer Measurements with Variable Blowing Rates Using Molecular Tagging Velocimetry

Measurements of mean and instantaneous streamwise velocity profiles in a hypersonic boundary layer with variable rates of mass injection (blowing) of nitrogen dioxide (NO2) were obtained over a 10-degree half-angle wedge model. The NO2 was seeded into the flow from a slot located 29.4 mm downstream of the sharp leading edge. The top surface of the wedge was oriented at a 20 degree angle in the Mach 10 flow, yielding an edge Mach number of approximately 4.2. The streamwise velocity profiles and streamwise fluctuating velocity component profiles were obtained using a three-laser NO2->NO photolysis molecular tagging velocimetry method. Observed trends in the mean streamwise velocity profiles and profiles of the fluctuating component of streamwise velocity as functions of the blowing rate are described. An effort is made to distinguish between the effect of blowing rate and wall temperature on the measured profiles. An analysis of the mean velocity profiles for a constant blowing rate is presented to determine the uncertainty in the measurement for different probe laser delay settings. Measurements of streamwise velocity were made to within approximately 120 gm of the model surface. The streamwise spatial resolution in this experiment ranged from 0.6 mm to 2.6 mm. An improvement in the spatial precision of the measurement technique has been made, with spatial uncertainties reduced by about a factor of 2 compared to previous measurements. For the quiescent flow calibration measurements presented, uncertainties as low as 2 m/s are obtained at 95% confidence for long delay times (25 gs). For the velocity measurements obtained with the wind tunnel operating, average single-shot uncertainties of less than 44 m/s are obtained at 95% confidence with a probe laser delay setting of 1 gs. The measurements were performed in the 31-inch Mach 10 Air Tunnel at the NASA Langley Research Center.

Bathel, Brett F.↗

Efficient computation of parameter confidence intervals

An important step in system identification of aircraft is the estimation of stability and control derivatives from flight data along with an assessment of parameter accuracy. When the maximum likelihood estimation technique is used, parameter accuracy is commonly assessed by the Cramer-Rao lower bound. It is known, however, that in some cases the lower bound can be substantially different from the parameter variance. Under these circumstances the Cramer-Rao bounds may be misleading as an accuracy measure. This paper discusses the confidence interval estimation problem based on likelihood ratios, which offers a more general estimate of the error bounds. Four approaches are considered for computing confidence intervals of maximum likelihood parameter estimates. Each approach is applied to real flight data and compared.

Murphy, Patrick C.↗

The Atacama Cosmology Telescope: Mitigating the Impact of Extragalactic Foregrounds for the DR6 Cosmic Microwave Background Lensing Analysis

We investigate the impact and mitigation of extragalactic foregrounds for the cosmic microwave background (CMB) lensing power spectrum analysis of Atacama Cosmology Telescope (ACT) data release 6 (DR6) data. Two independent microwave sky simulations are used to test a range of mitigation strategies. We demonstrate that finding and then subtracting point sources, finding and then subtracting models of clusters, and using a profile bias-hardened lensing estimator together reduce the fractional biases to well below statistical uncertainties, with the inferred lensing amplitude, A lens , biased by less than 0.2σ. We also show that another method where a model for the cosmic infrared background (CIB) contribution is deprojected and high-frequency data from Planck is included has similar performance. Other frequency-cleaned options do not perform as well, either incurring a large noise cost or resulting in biased recovery of the lensing spectrum. In addition to these simulation-based tests, we also present null tests on the ACT DR6 data for sensitivity of our lensing spectrum estimation to differences in foreground levels between the two ACT frequencies used, while nulling the CMB lensing signal. These tests pass whether the nulling is performed at the map or bandpower level. The CIB-deprojected measurement performed on the DR6 data is consistent with our baseline measurement, implying that contamination from the CIB is unlikely to significantly bias the DR6 lensing spectrum. This collection of tests gives confidence that the ACT DR6 lensing measurements and cosmological constraints presented in companion papers to this work are robust to extragalactic foregrounds.

79 ASTRONOMY AND ASTROPHYSICS↗

Determining Normal-Distribution Tolerance Bounds Graphically

Graphical method requires calculations and table lookup. Distribution established from only three points: mean upper and lower confidence bounds and lower confidence bound of standard deviation. Method requires only few calculations with simple equations. Graphical procedure establishes best-fit line for measured data and bounds for selected confidence level and any distribution percentile.

Mezzacappa, M. A.↗

Uncertainty Analysis of Instrument Calibration and Application

Experimental aerodynamic researchers require estimated precision and bias uncertainties of measured physical quantities, typically at 95 percent confidence levels. Uncertainties of final computed aerodynamic parameters are obtained by propagation of individual measurement uncertainties through the defining functional expressions. In this paper, rigorous mathematical techniques are extended to determine precision and bias uncertainties of any instrument-sensor system. Through this analysis, instrument uncertainties determined through calibration are now expressed as functions of the corresponding measurement for linear and nonlinear univariate and multivariate processes. Treatment of correlated measurement precision error is developed. During laboratory calibration, calibration standard uncertainties are assumed to be an order of magnitude less than those of the instrument being calibrated. Often calibration standards do not satisfy this assumption. This paper applies rigorous statistical methods for inclusion of calibration standard uncertainty and covariance due to the order of their application. The effects of mathematical modeling error on calibration bias uncertainty are quantified. The effects of experimental design on uncertainty are analyzed. The importance of replication is emphasized, techniques for estimation of both bias and precision uncertainties using replication are developed. Statistical tests for stationarity of calibration parameters over time are obtained.

Tripp, John S.↗

Development of a multicomponent force and moment balance for water tunnel applications, volume 1

The principal objective of this research effort was to develop a multicomponent strain gauge balance to measure forces and moments on models tested in flow visualization water tunnels. An internal balance was designed that allows measuring normal and side forces, and pitching, yawing and rolling moments (no axial force). The five-components to applied loads, low interactions between the sections and no hysteresis. Static experiments (which are discussed in this Volume) were conducted in the Eidetics water tunnel with delta wings and a model of the F/A-18. Experiments with the F/A-18 model included a thorough baseline study and investigations of the effect of control surface deflections and of several Forebody Vortex Control (FVC) techniques. Results were compared to wind tunnel data and, in general, the agreement is very satisfactory. The results of the static tests provide confidence that loads can be measured accurately in the water tunnel with a relatively simple multicomponent internal balance. Dynamic experiments were also performed using the balance, and the results are discussed in detail in Volume 2 of this report.

Suarez, Carlos J.↗

On the Confidence Limit of Hilbert Spectrum

Confidence limit is a routine requirement for Fourier spectral analysis. But this confidence limit is established based on ergodic theory: For stationary process, temporal average equals the ensemble average. Therefore, one can divide the data into n-sections and treat each section as independent realization. Most natural processes in general, and climate data in particular, are not stationary; therefore, there is a need for the Hilbert Spectral analysis for such processes. Here ergodic theory is no longer applicable. We propose to use various adjustable parameters in the shifting processes of the Empirical Mode Decomposition (EMD) method to obtain an ensemble of Intrinsic Mode Function 0 sets. Based on such an ensemble, we introduce a statistical measure in. a form of confidence limits for the Intrinsic Mode Functions, and consequently, the Hilbert spectra. The criterion of selecting the various adjustable parameters is based on the orthogonality test of the resulting M F sets. Length-of-day data from 1962 to 2001 will be used to illustrate this new approach. Its implication in climate data analysis will also be discussed.

Huang, Norden↗

Establishing and Verifying the Traceability of Remote-Sensing Measurements to International Standards

This viewgraph presentation reviews the principles of establishing and verifying the traceability of remote sensing measurements to national and international scales. Doing this allows comparisons to be made independent of time or locale, and improves understanding of instrument performance, provides confidence in the accuracy of the measurements, improves measurement accuracy and helps contractors understand and meet agency requirements, protecting contractor and customer.

Fraser, Gerald T.↗

Development of a 5-Component Balance for Water Tunnel Applications

The principal objective of this research/development effort was to develop a multi-component strain gage balance to measure both static and dynamic forces and moments on models tested in flow visualization water tunnels. A balance was designed that allows measuring normal and side forces, and pitching, yawing and rolling moments (no axial force). The balance mounts internally in the model and is used in a manner typical of wind tunnel balances. The key differences between a water tunnel balance and a wind tunnel balance are the requirement for very high sensitivity since the loads are very low (typical normal force is 90 grams or 0.2 lbs), the need for water proofing the gage elements, and the small size required to fit into typical water tunnel models. The five-component balance was calibrated and demonstrated linearity in the responses of the primary components to applied loads, very low interactions between the sections and no hysteresis. Static experiments were conducted in the Eidetics water tunnel with delta wings and F/A-18 models. The data were compared to forces and moments from wind tunnel tests of the same or similar configurations. The comparison showed very good agreement, providing confidence that loads can be measured accurately in the water tunnel with a relatively simple multi-component internal balance. The success of the static experiments encouraged the use of the balance for dynamic experiments. Among the advantages of conducting dynamic tests in a water tunnel are less demanding motion and data acquisition rates than in a wind tunnel test (because of the low-speed flow) and the capability of performing flow visualization and force/moment (F/M) measurements simultaneously with relative simplicity. This capability of simultaneous flow visualization and for F/M measurements proved extremely useful to explain the results obtained during these dynamic tests. In general, the development of this balance should encourage the use of water tunnels for a wider range of quantitative and qualitative experiments, especially during the preliminary phase of aircraft design.

Suarez, Carlos J.↗

The optimum cost-effective test time for redundant systems with specified reliability and confidence

This paper investigates the optimum test time to determine the number of redundant units needed to achieve high reliability with high confidence. Newly designed systems often have high initial failure rates which can be reduced by testing to find failure modes and remove them by redesign. To accurately estimate the required number of redundant units, the test time must be extended to accurately determine the failure rate. If the measured failure rate is used, there is a 50% chance that the actual hardware failure rate is higher. Using the measured failure rate gives only a 50% confidence that the failure rate and number of spares are not too low. After the test, given the measured failure rate and the desired reliability, the number of spares can be determined and the confidence in the reliability computed. Instead of accepting the reliability results of a fixed duration test, it is possible to set the requirements for both the redundant reliability and the confidence level and then compute the test time needed to minimize the total cost required to achieve these requirements. The confidence that the redundant reliability is not too low is increased by using a higher than measured failure rate to increase the number of spares. The higher number of spares increases cost. Longer test time reduces the variance in the failure rate and the increase in the number of spares, so that test cost increases and spares cost decreases. The total cost is the sum of the cost of the test time and the spares. The optimum test time produces the minimum total cost for the system failure rate, mission length, and required reliability and confidence level. Longer testing is justified by reduced cost. Some examples are given.

Harry W Jones↗

Experimental measurements and mathematical modeling of cold plate for aviation thermal management

Herein, this study, which has been motivated by the recent applications of the cold plate device in aviation thermal management, reports on physics-based mathematical models derived from the conservation laws of mass, momentum, and energy, and empiricism-based models. One of the objectives of the present work is to report on an elaborate and successful experimental work carried out on an additively manufactured device for the purpose of rigorously validating the numerical predictions. The excellent agreement between the numerical predictions and measured performance provides much needed confidence in the implementation, in the software package, of the offset-strip fin passage correlations, as well as in the software implementation of user-defined wavy fin correlations for aerospace heat exchangers and cold plates operating with ram air at Reynolds numbers below 8000. The contributions of this work can also be found in the development of a new and accurate thermal-hydraulic analysis procedure, referred to in this paper as plate-fin analogy. Results from this procedure are compared with those from thermal resistance network. The comparative study in this paper of the bulk and discrete enthalpy flux method is also new, as is the relative assessment of four off-set strip fin thermal-hydraulic models.

42 ENGINEERING↗

Asymmetric errors

We present a procedure for handling asymmetric errors. Many results in particle physics are presented as values with different positive and negative errors, and there is no consistent procedure for handling them. We consider the difference between errors quoted, using pdfs and using likelihoods, and the difference between the rms spread of a measurement and the 68% central confidence region. We provide a comprehensive analysis of the possibilities, and software tools to enable their use.

Asymmetric↗

Search for a bound di-neutron by comparing 3 He(e,e'p)d and 3 H(e,e'p)X measurements

We report on a search for a bound di-neutron by comparing electron-induced proton-knockout $(e,e'p)$ measurements from Helium-3 ($^3$He) and Tritium ($^3$H). The measurements were performed at Jefferson Lab Hall A with a 4.326 GeV electron beam, and kinematics of large momentum transfer $Q^2 \approx 1.9$ (GeV/$c$)$^2$ and $x_B>1$, to minimize contributions from non quasi-elastic (QE) reaction mechanisms. Analyzing the measured $^3$He missing mass ($M_{miss}$) and missing energy ($E_{miss}$) distributions, we can distinguish the two-body break-up reaction, in which the residual proton-neutron system remains bound as a deuteron. In the $^3$H mirror case, under the exact same kinematic conditions, we do not identify a signature for a bound di-neutron with similar binding energy to that of the deuteron. We calculate exclusion limits as a function of the di-neutron binding energy and find that, for binding equivalent to the deuteron, the two-body break-up cross section on $^3$H is less than 0.9% of that on $^3$He in the measured kinematics at the 95% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantifying the Impact of Charge Rate and Number of Cycles on Structural Degeneration of Li-Ion Battery Electrodes

A quantitative link between crack evolution in lithium-ion positive electrodes and the degrading performance on cells is not yet well established nor is any single technique capable of doing so widely available. Here, we demonstrate a widely accessible high-throughput approach to quantifying crack evolution within electrodes. The approach applies super-resolution scanning electron microscopy (SEM) imaging of cross-sectioned NMC532 electrodes, followed by segmentation and quantification of crack features. Crack properties such as crack intensity, crack width and length are quantified as a function of charge rate (1C, 6C, and 9C) and cycle number (25, 225, and 600 cycles). Hundreds of particles are characterized for statistical confidence in the quantitative crack measurements. The data on crack evolution is compared to electrochemical data from full cells and half cells with the NMC532 positive electrodes. We show that while crack evolution strongly correlates with capacity fade in the first 25 cycles, it does not correlate well for the following hundreds of cycles indicating that cracking may not be the dominant cause of capacity fade throughout the cycle-life of cells.

25 ENERGY STORAGE↗

A Catalog of 71 Coronal Line Galaxies in MaNGA: [Ne v] Is an Effective AGN Tracer

Despite the importance of active galactic nuclei (AGNs) in galaxy evolution, accurate AGN identification is often challenging, as common AGN diagnostics can be confused by contributions from star formation and other effects (e.g., Baldwin–Phillips–Terlevich diagrams). However, one promising avenue for identifying AGNs is "coronal emission lines" ("CLs"), which are highly ionized species of gas with ionization potentials ≥100 eV. These CLs may serve as excellent signatures for the strong ionizing continuum of AGNs. To determine if CLs are in fact strong AGN tracers, we assemble and analyze the largest catalog of optical CL galaxies using the Sloan Digital Sky Survey's Mapping Nearby Galaxies at Apache Point Observatory (MaNGA) catalog. We detect CL emission in 71 MaNGA galaxies, out of the 10,010 unique galaxies from the final MaNGA catalog, with ≥5σ confidence. In our sample, we measure [Ne v]λ3347, λ3427, [Fe vii]λ3586, λ3760, λ6086, and [Fe x]λ6374 emission and crossmatch the CL galaxies with a catalog of AGNs that were confirmed with broad-line, X-ray, IR, and radio observations. We find that [Ne v] emission, compared to [Fe vii] and [Fe x] emission, is best at identifying high-luminosity AGNs. Moreover, we find that the CL galaxies with the least dust extinction yield the most iron CL detections. We posit that the bulk of the iron CLs are destroyed by dust grains in the galaxies with the highest [O III ] luminosities in our sample, and that AGNs in the galaxies with low [O III ] luminosities are possibly too weak to be detected using traditional techniques.

79 ASTRONOMY AND ASTROPHYSICS↗

Summary of ionizing radiation analysis on the Long Duration Exposure Facility

The ionizing radiation measurements flown on the Long Duration Exposure Facility (LDEF) were contained in 15 experiments which utilized passive detectors to pursue objectives in astrophysics and to measure the radiation environment and dosimetric quantities. The spacecraft structure became sufficiently radioactive to permit additional important studies. The induced activity allows extensive radiation mapping in the structure, and independent comparison with experiment dosimetric techniques, and significant studies of secondary effects. The long exposure time, attitude stability, and number and types of measurements produced a unique and critical set of data for low Earth orbit that will not be duplicated for more than a decade. The data allow an unprecedented test, and improvement if required, of models of the radiation environment and the radiation transport methods that are used to calculate the internal radiation and its effects in spacecraft. Results of measurements in the experiments, as well as from radioactivity in the structure, have clearly shown effects from the directional properties of the radiation environment, and progress was made in the dosimetric mapping of LDEF. These measurements have already influenced some Space Station Freedom design requirements. Preliminary results from experiments, reported at this symposium and in earlier papers, show that the 5.8 years exposure considerably enhanced the scientific return of the radiation measurements. The early results give confidence that the experiments will make significant advances in the knowledge of ultra heavy cosmic rays, anomalous cosmic rays, and heavy ions trapped in the radiation belts. Unexpected phenomena were observed, which require explanation. These include stopping iron group ions between the energy ranges anticipated for anomalous and galactic cosmic rays in the LDEF orbit. A surprising concentration of the Be-7 nuclide was discovered on the 'front' surface of LDEF, apparently transported up from the stratosphere with exceptional efficiency.

Parnell, T. A.↗