Gravity Effect on Capillary Limit in a Miniature Loop Heat Pipe with Multiple Evaporators and Multiple Condensers

This paper describes the gravity effect on heat transport characteristics in a minia6re loop heat pipe with multiple evaporators and multiple condensers. Tests were conducted in three different orientations: horizontal, 45deg tilt, and vertical. The gravity affected the loop's natural operating temperature, the maximum heat transport capability, and the thermal conductance. In the case that temperatures of compensation chambers were actively controlled, the required control heater power was also dependent on the test configuration. In the vertical configuration, the secondary wick was not able to pump the liquid from the CC to the evaporator against the gravity. Thus the loop could operate stably or display some peculiar behaviors depending on the initial liquid distribution between the evaporator and the CC. Because such an initial condition was not known prior to the test, the subsequent loop performance was unpredictable.

Nagano, Hosei↗

The direction of water transport on Mars: A possible pumping mechanism

It is suggested that an atmospheric pumping mechanism might be at work in which water is preferentially transported into the north by a mass outflow wind (due to sublimation from polar cap) that is stronger during southern spring than it is during northern spring. The mechanism is provided by the asymmetric seasonal temperature distribution produced by the eccentric martial orbit and by the associated seasonal asymmetry in the carbon dioxide cycle. The alternating condensation and sublimation of CO2 at the poles produces condensation winds which, in turn, contribute to the meridional transport of water vapor.

James, P. B.↗

CPL Materials Life Cycle Test Facility

The Capillary Pumped Loop (CPL) Materials Life Cycle Test Facility at the Goddard Space Flight Center (GSFC) will identify the operational parameters controlling the performance of a CPL over an extended period of time. The primary purpose of the facility is to investigate the long-term chemical compatibility between the anhydrous ammonia working fluid and the CPL materials of construction. Chemical reactions occurring within the system may produce non-condensable gases or particulate debris that can lead to a degradation in system performance. Small liquid samples will be drawn from the system at specific time intervals and analyzed to check for the presence of non-condensable gases. Periodic maximum and minimum heat load tests will be performed on the CPL to monitor trends in the overall system performance.

Buchko, Matthew T.↗

Development of a solar-powered residential air conditioner: Screening analysis

Screening analysis aimed at the definition of an optimum configuration of a Rankine cycle solar-powered air conditioner designed for residential application were conducted. Initial studies revealed that system performance and cost were extremely sensitive to condensing temperature and to the type of condenser used in the system. Consequently, the screening analyses were concerned with the generation of parametric design data for different condenser approaches; i. e., (1) an ambient air condenser, (2) a humidified ambient air condenser (3) an evaporative condenser, and (4) a water condenser (with a cooling tower). All systems feature a high performance turbocompressor and a single refrigerant (R-11) for the power and refrigeration loops. Data were obtained by computerized methods developed to permit system characterization over a broad range of operating and design conditions. The criteria used for comparison of the candidate system approaches were (1) overall system COP (refrigeration effect/solar heat input), (2) auxiliary electric power for fans and pumps, and (3) system installed cost or cost to the user.

Source record↗

A Review of Recent Advances in Heat Exchanger Technology and Future Applications

This talk describes current and historical efforts concerning the development of condensing heat exchangers for use in space systems. These devices are used for a wide range of applications, including humidity/environmental control and multiphase fluid systems in Earth and in space. Therefore, keeping these systems running consistently and with minimal downtime/repairs is a high priority for exploration life support. Recent advances in low gravity capillary fluidics can be applied to newer systems and offer continuous operation in the event of a system pump failure or blockage. Additionally, new methods in femtosecond laser processing have been used to create microbial resistant surfaces with unique wetting characteristics. This research builds on experiments at both Glenn Research Center and Johnson Space Center. Future applications of this work will also be discussed, including water processing and plant growth systems.

heat exchanger↗

Staged regenerative sorption heat pump

A regenerative adsorbent heat pump process and system for cooling and heating a space. A sorbent is confined in a plurality of compressors of which at least four are first stage and at least four are second stage. The first stage operates over a first pressure region and the second stage over a second pressure region which is higher than the first. Sorbate from the first stage enters the second stage. The sorbate loop includes a condenser, expansion valve, evaporator and the compressors. A single sorbate loop can be employed for single-temperature-control such as air conditioning and heating. Two sorbate loops can be used for two-temperature-control as in a refrigerator and freezer. The evaporator temperatures control the freezer and refrigerator temperatures. Alternatively the refrigerator temperature can be cooled by the freezer with one sorbate loop. A heat transfer fluid is circulated in a closed loop which includes a radiator and the compressors. Low temperature heat is exhausted by the radiator. High temperature heat is added to the heat transfer fluid entering the compressors which are desorbing vapor. Heat is transferred from compressors which are sorbing vapor to the heat transfer fluid, and from the heat transfer fluid to the compressors which are desorbing vapor. Each compressor is subjected to the following phases, heating to its highest temperature, cooling down from its highest temperature, cooling to its lowest temperature, and warming up from its lowest temperature. The phases are repeated to complete a cycle and regenerate heat.

Jones, Jack A.↗

Development of a solar powered residential air conditioner (General optimization)

A commercially available 3-ton residential Lithium Bromide (LiBr) absorption air conditioner was modified for use with lower temperature solar heated water. The modification included removal of components such as the generator, concentration control chamber, liquid trap, and separator; and the addition of a Chrysler designed generator, an off-the-shelf LiBr-solution pump. The design goal of the modified unit was to operate with water as the heat-transfer fluid at a target temperature of 85 C (185 F), 29.4 C (85 F) cooling water inlet, producing 10.5 kW (3 tons) of cooling. Tests were performed on the system before and after modification to provide comparative data. At elevated temperatures (96 C, 205 F), the test results show that Lithium Bromide was carried into the condenser due to the extremely violent boiling and degraded the evaporator performance.

Lowen, D. J.↗

Lunar Passive Fuel Cell Technologies: Evaporator + Fluid Polishing Elements

This project investigates key elements of a fully-passive, fuel-cell based, surface power generation concept. The overall concept replaces the actively pumped thermal management of a state of the art (SOA) fuel cell/electrolyzer stack with a passive 2-phase thermosyphon for heat transport and a passive shape memory actuating radiator for temperature management. The elements of the concept investigated in this project are: Evaporator Element: Evaluating the compatibility of common fuel-cell interconnect materials in the evaporator of a 2-phase water thermosyphon Fluid Polishing element: The use of membrane gas separation and resin water polishing to address non-condensable gas removal and water purity.

Fuel Cell↗

Modelling and experimental verification of a water alleviation system for the NASP

One possible low speed propulsion system for the National Aerospace Plane is a liquid air cycle engine (LACE). The LACE system uses the heat sink in the liquid hydrogen propellant to liquefy air in a heat exchanger which is then pumped up to high pressure and used as the oxidizer in a hydrogen liquid air rocket. The inlet airstream must be dehumidified or moisture could freeze on the cryogenic heat exchangers and block them. The main objective of this research has been to develop a computer simulation of the cold tube/antifreeze-spray water alleviation system and to verify the model with experimental data. An experimental facility has been built and humid air tests were conducted on a generic heat exchanger to obtain condensing data for code development. The paper describes the experimental setup, outlines the method of calculation used in the code, and presents comparisons of the calculations and measurements. Cause of discrepancies between the model and data are explained.

Vanfossen, G. James↗

Experimental studies of circumstellar, interstellar and interplanetary refractory grain analogs

Experimental techniques for studying the processes which occur during the life cycle of a refractory grain are reviewed. Consideration is given to the construction of a differentially-pumped beam-mass spectrometer which is expected to determine the relative stability of small clusters in the Fe-Mg-Si-O and Ca-Ti-Al-O systems as a function of temperature and pressure. Also, a smoke generator has been constructed to produce gram quantities of amorphous grains for use in thermal annealing and hydrous alteration studies of smokes containing Fe-Mg-Al-Ti-Ca-Si-O and Cl. Topics of the studies include the properties of grains produced in a flow condensation apparatus, the sorption efficiency of Si2O3 smokes for AR gas, the processing of ices containing refractory precursors such as SiH4 or Fe(CO)5 plus water, and the residue from 1 MeV bombardment and warming of an amorphous Fe-SiO smoke.

Nuth, J. A.↗

Lyophilization -Solid Waste Treatment

This paper discusses the development of a solid waste treatment system that has been designed for a Mars transit exploration mission. The technology described is an energy-efficient lyophilization technique that is designed to recover water from spacecraft solid wastes. Candidate wastes include feces, concentrated brines from water processors, and other solid wastes that contain free water. The system is designed to operate as a stand-alone process or to be integrated into the International Space Station Waste Collection System. In the lyophilization process, water in an aqueous waste is frozen and then sublimed, separating the waste into a dried solid material and liquid water. The sublimed water is then condensed in a solid ice phase and then melted to generate a liquid product. In the subject system the waste solids are contained within a 0.2 micron bio-guard bag and after drying are removed from the system and stored in a secondary container. This technology is ideally suited to applications such as the Mars Reference Mission, where water recovery rates approaching 100% are desirable but production of CO2 is not. The system is designed to minimize power consumption through the use of thermoelectric heat pumps. The results of preliminary testing of a prototype system and testing of the final configuration are provided. A mathematical model of the system is also described.

Litwiller, Eric↗

Capillary Pumped Loop Modeler

Capillary Pumped Loop (CPL) Modeler computer program is amalgamation of software that mathematically models performance of CPL system and its environment. Two-phase heat-transport device capable of transferring heat loads efficiently over large distance with little temperature differential. Utilizes surface-tension forces established in fine-pore capillary wick to circulate working fluid, requiring no external pumpling power. Predicts steady-state or quasi-steady behavior of CPL embedded in spacecraft or other thermal environment. Also predicts location of liquid/vapor interface in each condenser. Written in VAX/VMS FORTAN 77.

Ku, Jentung↗

Operational Experience with the Internal Thermal Control System Dual-Membrane Gas Trap

A dual-membrane gas trap is currently used to remove non-condensed gases (NCG) from the Internal Thermal Control System (ITCS) coolant on board the International Space Station. The gas trap consists of concentric tube membrane pairs, comprised of outer hydrophilic tubes and inner hydrophobic fibers. Liquid coolant passes through the outer hydrophilic membrane, which traps the NCG. The inner hydrophobic fiber allows the trapped NCG to pass through and vent to the ambient atmosphere in the cabin. The purpose of the gas trap is to prevent gas bubbles from causing depriming, overspeed, and shutdown of the ITCS pump, and the current gas trap has performed flawlessly in this regard. However, because of actual operational conditions on-orbit, its gas removal performance and operational lifetime have been affected. This paper discusses experiences with several of these dual- membrane gas traps, including on-orbit gas venting rate, effects due to the presence of nickel in the ITCS coolant, and subsequent refurbishing to remove the nickel from the gas trap.

Leimkuehler, Thomas O.↗

Response of the Water Cycle of West Africa and Atlantic to Radiative Forcing by Saharan Dust

The responses of the atmospheric water cycle and climate of West Africa and the Atlantic to radiative forcing of Saharan dust are studied using the NASA finite volume general circulation model (fvGCM), coupled to a mixed layer ocean. We find evidence in support of the "elevated heat pump" (EHP) mechanism that underlines the responses of the atmospheric water cycle to dust forcing as follow. During the boreal summer, as a result of large-scale atmospheric feed back triggered by absorbing dust aerosols, rainfall and cloudiness are enhanced over the West Africa/Easter Atlantic ITCZ, and suppressed over the West Atlantic and Caribbean. region. Shortwave radiation absorption by dust warms the atmosphere and cools the surface, while long wave has the opposite response. The elevated dust layer warms the air over Nest Africa and the eastern Atlantic. The condensation heating associated with the induced deep convection drives and maintains an anomalous large-scale east-west overturning circulation with rising motion over West Africa/eastern Atlantic, and sinking motion over the Caribbean region. The response also includes a strengthening of the West African monsoon, manifested in northward shift of the West Africa precipitation over land, increased low-level westerlies flow over West Africa at the southern edge of the dust layer, and a near surface energy fluxes, resulting in cooling of the Nest African land and the eastern Atlantic, and a warming in the West Atlantic and Caribbean. The EHP effect is most effective for moderate to highly absorbing dusts, and becomes minimized for reflecting dust with single scattering albedo at 0.95 or higher.

Lau, K. M.↗

The Martian polar caps: Stability and water transport at low obliquities

The seasonal cycle of water on Mars is regulated by the two polar caps. In the winter hemisphere, the seasonal CO2 deposits at a temperature near 150 K acts as a cold trap to remove water vapor from the atmosphere. When summer returns, water is pumped back into the atmosphere by a number of mechanisms, including release from the receding CO2 frost, diffusion from the polar regolith, and sublimation from a water-ice residual cap. These processes drive an exchange of water vapor between the polar caps that helps shape the Martian climate. Thus, understanding the behavior of the polar caps is important for interpreting the Martian climate both now and at other epochs. Mars' obliquity undergoes large variations over large time scales. As the obliquity decreases, the poles receive less solar energy so that more CO2 condenses from the atmosphere onto the poles. It has been suggested that permanent CO2 condenses from the atmosphere onto the poles. It has been suggested that permanent CO2 caps might form at the poles in response to a feedback mechanism existing between the polar cap albedo, the CO2 pressure, and the dust storm frequency. The year-round presence of the CO2 deposits would effectively dry out the atmosphere, while diffusion of water from the regolith would be the only source of water vapor to the atmosphere. We have reviewed the CO2 balance at low obliquity taking into account the asymmetries which make the north and south hemispheres different. Our analysis linked with a numerical model of the polar caps leads us to believe that one summertime cap will always lose its CO2 cover during a Martian year, although we cannot predict which cap this will be. We conclude that significant amounts of water vapor will sublime from the exposed cap during summer, and the Martian atmosphere will support an active water cycle even at low obliquity.

Henderson, B. G.↗

Cascade Distiller System Performance Testing Interim Results

The Cascade Distillation System (CDS) is a rotary distillation system with potential for greater reliability and lower energy costs than existing distillation systems. Based upon the results of the 2009 distillation comparison test (DCT) and recommendations of the expert panel, the Advanced Exploration Systems (AES) Water Recovery Project (WRP) project advanced the technology by increasing reliability of the system through redesign of bearing assemblies and improved rotor dynamics. In addition, the project improved the CDS power efficiency by optimizing the thermoelectric heat pump (TeHP) and heat exchanger design. Testing at the NASA-JSC Advanced Exploration System Water Laboratory (AES Water Lab) using a prototype Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell d International, Torrance, Calif.) with test support equipment and control system developed by Johnson Space Center was performed to evaluate performance of the system with the upgrades as compared to previous system performance. The system was challenged with Solution 1 from the NASA Exploration Life Support (ELS) distillation comparison testing performed in 2009. Solution 1 consisted of a mixed stream containing human-generated urine and humidity condensate. A secondary objective of this testing is to evaluate the performance of the CDS as compared to the state of the art Distillation Assembly (DA) used in the ISS Urine Processor Assembly (UPA). This was done by challenging the system with ISS analog waste streams. This paper details the results of the AES WRP CDS performance testing.

Callahan, Michael R.↗

Airborne infrared spectroscopy of Comet Wilson (1986l) and comparisons with Comet Halley

H2O and possibly CH4 have been detected in near-infrared spectra of Comet Wilson (1986l). The observed number and relative intensities of cometary H2O lines in the nu3 band at 2.65 microns were consistent with fluorescent excitation pumped by solar infrared photons. The H2O production rate in Comet Wilson was approximately 3 x 10 to the 29th/s at R = 1.2 AU; no pronounced temporal variability was observed. Lines in the nu3 band of CH4 at 3.3 microns were possibly detected at the 3 sigma confidence level. The CH4 abundance is in the range CH4/H2O = 0.014-0.045; the uncertainty is due primarily to the assumed effective excitation temperature of CH4. The CH4 abundance in this dynamically 'new' comet is similar to that observed in P/Halley. These values are low for equilibrium compositional models and very high for disequilibrium condensation in the solar nebula.

Larson, Harold P.↗

Mars Ecopoiesis Testbed

Mars surface conditions where liquid water is absent were simulated for the purposes of laboratory research. A pressure-temperature (P-T) profile was maintained in which no combination of pressure or temperature corresponds to the liquid region of the water phase diagram. The triple point of pure water occurs at T = 0.1oC and P(H2O) = 6.01 mbar; therefore all temperatures and pressures must be kept below these values, respectively. A 35-day test was performed in a commercial planetary simulation system (Techshot, Inc., Greenville, IN) in which the minimum night-time temperature was -80oC, the maximum daytime temperature was +26oC, the simulated day-night light cycle in earth hours was 12-on and 12-off, and the total pressure of the pure CO2 atmosphere was maintained below 11 mbar. Any water present was allowed to equilibrate with the changing temperature and pressure. The gas phase was sampled into a CR1-A condensation-mirror low-pressure hygrometer, which uses liquid nitrogen (down to 77oK) to determine the dew point (Buck Technologies, Boulder, CO). Dew point was measured once every hour and recorded on a data logger, along with the varying temperature in the chamber, from which the partial pressure of water was calculated. The resulting calculated daily cycles were tracked on the water P-T diagram, and no points were found to fall within the liquid-phase region of the diagram. It is concluded that there was no liquid water present throughout the test except during the initial pump-down period when aqueous specimens were introduced on the first day (less than 1 hour). Mars regolith simulant was present during this test, and further investigation is needed to determine whether liquid water could have been present or absent in the regolith in the form of brine. Biological samples consisting of Cyanobacteria: Anabena sp., Chroococcidiopsis CCMEE171, Plectonema boryanum; Eubacteria: Bacillus subtilis, Pseudomonas aeruginosa, and Eukaryota: Chlorella ellipsoidia were maintained in the simulator under the above-described conditions. The exposed specimens were tested for intracellular esterase activity, chlorophyll content (where appropriate) and reproductive survival. All tests yielded low-level positive results in all cases. In parallel to these terrestrial studies a planned design study was undertaken for the proposed test bed. Design requirements include compact assembly for transport and installation on the planetary surface (multiple units per mission would be expected), protective internal package for the release of organisms, a means of atmosphere exchange, access to sunlight, a means of penetrating the planetary surface, and most importantly a means of acquiring regolith while meeting the requirements of planetary protection. In consultation with advisers a design was created, and a large-scale mock-up of this design was fabricated by additive manufacturing at Techshot, Inc. with moving parts that simulated the components of the design. The mock-up assembly has been demonstrated to interested parties. A means of detecting live metabolism will also be included in the test bed. Several options were reviewed, and it is concluded that, by the time the ecopoiesis test bed is ready for testing the optimum instrument will be the equivalent of a hand-held mass spectrometer for metabolic gas analysis. This will maximize versatility and reveal much more information than could a detector of a single product (such as molecular oxygen), and the

Ecopoiesis↗