Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “compton Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Development of backlighting sources for a Compton Radiography diagnostic of Inertial Confinement Fusion targets

An important diagnostic tool for inertial confinement fusion is time-resolved imaging of the dense cold fuel surrounding the hot spot. Here we report on the source and diagnostic development of hard x-ray radiography and on the first radiographs of direct drive implosions obtained at photon energies up to about 100keV, where the Compton effect is the dominant contributor to the shell opacity. The radiographs of direct drive, plastic shell implosions obtained at the OMEGA laser facility have a spatial resolution of {approx}10um and a temporal resolution of {approx}10ps. This novel Compton Radiography is an invaluable diagnostic tool for Inertial Confinement Fusion targets, and will be integrated at the National Ignition Facility (NIF).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cross sections for the exclusive photon electroproduction on the proton and Generalized Parton Distributions

Unpolarized and beam-polarized four-fold cross sections $\frac{d^4 \sigma}{dQ^2 dx_B dt d\phi}$ for the $ep\to e^\prime p^\prime \gamma$ reaction were measured using the CLAS detector and the 5.75-GeV polarized electron beam of the Jefferson Lab accelerator, for 110 ($Q^2,x_B,t$) bins over the widest phase space ever explored in the valence-quark region. Several models of Generalized Parton Distributions (GPDs) describe the data well at most of our kinematics. This increases our confidence that we understand the GPD $H$, expected to be the dominant contributor to these observables. Thus, through a leading-twist extraction of Compton Form Factors, these results reveal a tomographic image of the nucleon.

43 PARTICLE ACCELERATORS↗

Recommended Priorities for NASA's Gamma Ray Astronomy Program 1999-2013

The Gamma-Ray Astronomy Program Working Group (GRAPWG) recommends priorities for the NASA Gamma-Ray Astronomy Program. The highest priority science topic is nuclear astrophysics and sites of gamma ray line emission. Other high priority topics are gamma ray bursts, hard x-ray emission from accreting black holes and neutron stars, the Advanced Compton Telescope (ACT), the High-resolution Spectroscopic Imager (HSI), and the Energetic X-ray Imaging Survey Telescope (EXIST). The recommendations include special consideration for technology development, TeV astronomy, the ultra-long duration balloon (ULDB) program, the International Space Station, optical telescope support, and data analysis and theory.

Carol, Ladd↗

SENSITIVITY OF STACKED IMAGING DETECTORS TO HARD X-RAY POLARIZATION

The development of multi-layer optics which allow to focus photons up to 100 keV and more promises an enormous jump in sensitivity in the hard X-ray energy band. This technology is already planned to be exploited by future missions dedicated to spectroscopy and imaging at energies >10 keV, e.g., Astro-H and NuSTAR. Nevertheless, our understanding of the hard X-ray sky would greatly benefit from carrying out contemporaneous polarimetric measurements, because the study of hard spectral tails and of polarized emission are often two complementary diagnostics of the same non-thermal and acceleration processes. At energies above a few tens of keV, the preferred technique to detect polarization involves the determination of photon directions after a Compton scattering. Many authors have asserted that stacked detectors with imaging capabilities can be exploited for this purpose. If it is possible to discriminate those events which initially interact in the first detector by Compton scattering and are subsequently absorbed by the second layer, then the direction of scattering is singled out from the hit pixels in the two detectors. In this paper, we give the first detailed discussion of the sensitivity of such a generic design to the X-ray polarization. The efficiency and the modulation factor are calculated analytically from the geometry of the instruments and then compared with the performance as derived by means of Geant4 Monte Carlo simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of the 3-D Track Imager for Medium and High-Energy Gamma-Ray Telescopes

The Advanced Compton Telescope (ACT) and Advanced Pair Telescope (APT) are envisioned as the next medium (0.3 ^ 50 MeV) and high-energy (30 MeV - greater than 100 GeV) gamma-ray missions. These missions will address many research focus areas of the Structure and Evolution of the Universe Roadmap. These areas include: element formation, matter, energy, & magnetic field interactions in galaxies, AGN & GRB emission, and behavior of matter in extreme environments of black holes & pulsars. Achieving these science goals requires a substantial increases in telescope sensitivity and angular resolution. This talk will discuss how these goals can be met with the three-dimensional track imager (3-DTI), a large volume, low density, time projection chamber with two-dimensional micro-well detector readout and report on our development of a 10 cm x 10 cm x 30 prototype instrument.

Hunter, Stanley D.↗

Development of Compton radiography of inertial confinement fusion implosions

An important diagnostic tool for inertial confinement fusion will be time-resolved radiographic imaging of the dense cold fuel surrounding the hot spot. The measurement technique is based on point-projection radiography at photon energies from 60 to 200 keV where the Compton effect is the dominant contributor to the opacity of the fuel or pusher. We have successfully applied this novel Compton radiography technique to the study of the final compression of directly driven plastic capsules at the OMEGA facility [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)]. The radiographs have a spatial and temporal resolution of {approx}10 {mu}m and {approx}10 ps, respectively. A statistical accuracy of {approx}0.5% in transmission per resolution element is achieved, allowing localized measurements of areal mass densities to 7% accuracy. The experimental results show 3D nonuniformities and lower than 1D expected areal densities attributed to drive asymmetries and hydroinstabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Metrology, applications and methods with high energy CT systems

The increase of Computed Tomography (CT) as an applicable metrology and Non Destructive Testing (NDT) method raises interest on developing the application fields to larger objects, which were rarely used in the past due to their requirements on the imaging system. Especially the classical X-ray generation techniques based on standard equipment restricted the applications of CT to typical material penetration lengths of only a few cm of steel. Even with accelerator technology that offers a suitable way to overcome these restrictions just the 2D radioscopy technique found a widespread application. Beside the production and detection of photons in the MeV range itself, the achievable image quality is limited using standard detectors due to the dominating absorption effect of Compton Scattering at high energies. Especially for CT reconstruction purposes these effects have to be considered on the development path from 2D to 3D imaging. Most High Energy CT applications are therefore based on line detectors shielding scattered radiation to a maximum with an increase in imaging quality but with time consuming large volume scan capabilities. In this contribution we present the High-Energy X-ray Imaging project at the Fraunhofer Development Centre for X-ray Technology with the characterization and the potential of the CT-system according to metrological and other application capabilities.

43 PARTICLE ACCELERATORS↗

RADIATIVE MODELS OF SGR A* FROM GRMHD SIMULATIONS

Using flow models based on axisymmetric general relativistic magnetohydrodynamics simulations, we construct radiative models for Sgr A*. Spectral energy distributions (SEDs) that include the effects of thermal synchrotron emission and absorption, and Compton scattering, are calculated using a Monte Carlo technique. Images are calculated using a ray-tracing scheme. All models are scaled so that the 230 GHz flux density is 3.4 Jy. The key model parameters are the dimensionless black hole spin a{sub *}, the inclination i, and the ion-to-electron temperature ratio T{sub i}/T {sub e}. We find that (1) models with T{sub i}/T {sub e} = 1 are inconsistent with the observed submillimeter spectral slope; (2) the X-ray flux is a strongly increasing function of a{sub *}; (3) the X-ray flux is a strongly increasing function of i; (4) 230 GHz image size is a complicated function of i, a{sub *}, and T{sub i}/T{sub e}, but the T{sub i}/T{sub e} = 10 models are generally large and at most marginally consistent with the 230 GHz very long baseline interferometry (VLBI) data; (5) for models with T {sub i}/T{sub e} = 10 and i = 85 deg. the event horizon is cloaked behind a synchrotron photosphere at 230 GHz and will not be seen by VLBI, but these models overproduce near-infrared and X-ray flux; (6) in all models whose SEDs are consistent with observations, the event horizon is uncloaked at 230 GHz; (7) the models that are most consistent with the observations have a{sub *} approx 0.9. We finish with a discussion of the limitations of our model and prospects for future improvements.

79 ASTRONOMY AND ASTROPHYSICS↗

Gamma-ray imaging of Np-237 metal using an organic glass imager

Neutron and gamma-ray imaging systems are deployed within the field of nuclear safeguards for the detection and localization of special nuclear materials and other materials of interest. 237 Np is one of these materials of interest due its presence in spent nuclear fuel and potential for use in nuclear weapons when purified. Here, for the first time, a 6 kg neptunium sphere (98.8 wt% 237 Np) was measured using a dual-particle imager, from the University of Michigan, consisting of organic glass and inorganic scintillators. The novel composition of organic glass scintillator was recently developed at Sandia National Labs and has been used in particle imaging systems due to its time resolution and particle discrimination capabilities. Gamma-ray energy spectra from single and coincident events were extracted and the sequencing of Compton scatter and photoelectric absorption gamma-ray events was used to generate images using simple backprojection. The emissions of interest in this work are the 312 keV and 416 keV gamma rays from 233 Pa, a daughter isotope from the neptunium decay series. The results of this work show that there is close agreement between the true source location in angular space and the converged location from the gamma ray images created using the system. The gamma spectroscopy from single and coincident events also identified the characteristic emission from the daughter isotope and could be used to assist with the identification of 237 Np. Furthermore, successful localization of the source with 5 s of data demonstrates the practical application of the imaging system for imaging and detection of material in weapons-useable quantities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A prototype compton camera for in-vivo dosimetry of ion beam cancer irradiation

Three-dimensional in-vivo dose monitoring of ion beam cancer irradiation can improve the quality of treatment. For this purpose we investigate the feasibility of imaging the single photon emissions due to nuclear reactions of projectiles with target nuclei (in-beam SPECT). A suitable imaging technique in the energy range of the emitted gamma rays is the Compton camera. A prototype based on prior simulations is currently under construction. Te system comprises two CdZnTe cross-strip detectors with steering grid and depth-of-interaction capability and one segmented LSO scintillator crystal with modified Anger light readout. We present the concept of the system including the front-end and DAQ electronics as well as first measurements. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observational Possibility of the Early GRBs using a Gaseous Electron Tracking Compton Camera in sub-MeV and MeV regions

GRBs have been recently known as a unique probe to catch the highest z galaxies and stars. Here I propose the new trigger method to catch high-z GRBs with z>10 efficiently by imaging sub-MeV gamma rays from GRBs. We have developed the Electron Tracking Compton Camera (ETCC) with reconstructing tracks of the recoil electron in Compton process to explore the MeV gamma-ray astronomy. By measuring the track of a recoil electron, the direction of the incident gamma ray is determined for each photon, which enables us to reconstruct the direction of GRBs by detecting only several ten photons (>100 keV). Ability of the large ETCC (100 cm{sup 2} effective area) to detect GRBs with z{approx}20 is revealed, based on the results of the balloon experiment and laboratory imaging test using the small ETCC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma electron vertex imaging and application to beam range verification in proton therapy

Purpose: This paper describes a new gamma-ray imaging method, ''gamma electron vertex imaging (GEVI)'', which can be used for precise beam range verification in proton therapy. Methods: In GEVI imaging, the high-energy gammas from a source or nuclear interactions are first converted, by Compton scattering, to electrons, which subsequently are traced by hodoscopes to determine the location of the gamma source or the vertices of the nuclear interactions. The performance of GEVI imaging for use in-beam range verification was evaluated by Monte Carlo simulations employing geant4 equipped with the QGSP{sub B}IC{sub H}P physics package. Results: Our simulation results show that GEVI imaging can determine the proton beam range very accurately, within 2-3 mm of error, even without any sophisticated analysis. The results were obtained under simplified conditions of monoenergetic pencil beams stopped in a homogeneous phantom and on the basis of the obtained results it is expected to achieve submillimeter accuracy in proton beam range measurement. Conclusions: If future experimental work confirms the simulated results presented in this paper, the use of GEVI imaging is expected to have a great potential in increasing the accuracy of proton beam range verification in a patient, resulting in significant improvement of treatment effectiveness by enabling tight conformation of radiation dose to the tumor volume and patient safety.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resolution recovery for Compton camera using origin ensemble algorithm

Purpose: Compton cameras (CCs) use electronic collimation to reconstruct the images of activity distribution. Although this approach can greatly improve imaging efficiency, due to complex geometry of the CC principle, image reconstruction with the standard iterative algorithms, such as ordered subset expectation maximization (OSEM), can be very time-consuming, even more so if resolution recovery (RR) is implemented. We have previously shown that the origin ensemble (OE) algorithm can be used for the reconstruction of the CC data. Here we propose a method of extending our OE algorithm to include RR. Methods: To validate the proposed algorithm we used Monte Carlo simulations of a CC composed of multiple layers of pixelated CZT detectors and designed for imaging small animals. A series of CC acquisitions of small hot spheres and the Derenzo phantom placed in air were simulated. Images obtained from (a) the exact data, (b) blurred data but reconstructed without resolution recovery, and (c) blurred and reconstructed with resolution recovery were compared. Furthermore, the reconstructed contrast-to-background ratios were investigated using the phantom with nine spheres placed in a hot background. Results: Our simulations demonstrate that the proposed method allows for the recovery of the resolution loss that is due to imperfect accuracy of event detection. Additionally, tests of camera sensitivity corresponding to different detector configurations demonstrate that the proposed CC design has sensitivity comparable to PET. When the same number of events were considered, the computation time per iteration increased only by a factor of 2 when OE reconstruction with the resolution recovery correction was performed relative to the original OE algorithm. We estimate that the addition of resolution recovery to the OSEM would increase reconstruction times by 2–3 orders of magnitude per iteration. Conclusions: The results of our tests demonstrate the improvement of image resolution provided by the OE reconstructions with resolution recovery. The quality of images and their contrast are similar to those obtained from the OE reconstructions from scans simulated with perfect energy and spatial resolutions.

60 APPLIED LIFE SCIENCES↗

High-energy gamma rays from the intense 1993 January 31 gamma-ray burst

The intense gamma-ray burst of 1993 January 31 was detected by the Energetic Gamma Ray Experiment Telescope (EGRET) on the Compton Observatory. Sixteen gamma rays above 30 MeV were imaged in the telescope when only 0.04 gamma rays were expected by chance. Two of these gamma rays have energies of approximately 1 GeV, and the five bin spectrum of the 16 events is fitted by a power law of photon spectral index -2.0 +/- 0.4. The high-energy emission extends for at least 25 s. The most probable direction for this burst is determined from the directions of the 16 gamma rays observed by Egret and also by requiring the position to lie on annulus derived by the Interplanetary Network.

Sommer, M.↗

COMPTEL observations of Ti-44 gamma-ray line emission from Cas A

The Compton Telescope (COMPTEL) telescope aboard the Compton Gamma-Ray Observatory (CGRO) is capable of imaging gamma-ray line sources in the MeV region with a sensitivity of the order 10(exp -5) photons/(sq cm s). During two observations periods in July 1992 and February 1993 the Galactic plane in the region of the young supernova remnant Cas A was observed, showing evidence for line emission at 1.16 MeV from the decay of Ti-44 at a significance level of approximately 4 sigma. This is the first time a supernova remnant has been detected in the gamma-ray line from Ti-44 decay. Adopting a distance of 2.8 kpc to the Cas A remnant, the measured line flux (7.0 +/- 1.7) x 10(exp -5) photons/(sq cm s), can be translated into a Ti-44 mass ejected during the Cas A supernova explosion, between (1.4 +/- 0.4) x 10(exp -4) solar mass and (3.2 +/- 0.8) x 10(exp -4) solar mass, depending on the precise value of the Ti-44 mean life time and on the precise date of the event. Implications of this result for supernova nucleosynthesis models are discussed.

Iyudin, A. F.↗

Nondestructive Evaluation of Foam Insulation on the Space Shuttle External Tank

Foam loss on the External Tank (ET) during launch can be caused by a number of factors. Voids are the best understood mechanism of foam loss, although it is known that delaminations, cracks and crushed foam can also lead to liberation of foam. Shortly after the Columbia accident, work began on non-destructive evaluation of foam targeted at finding voids and delaminations. After several months of searching for candidate methods capable of inspecting ET foam, the five most promising techniques were taken through a blind test and narrowed down to two methods to develop and use for inspection of the ET. These methods were backscatter radiography and terahertz imaging. The backscatter radiography system measures a test part by detecting Compton backscattered x-ray energy generated by a collimated beam of x-rays directed at the test subject. This collimated beam is scanned across the subject, recording scatter intensity data one pixel at a time until the area of interest is covered. The resulting data can be used to generate an image similar to a radiograph. Some depth information can be gathered utilizing apertures or collimation on the detectors. The detectors are located around the collimated source, making this a single sided inspection. The void detection limit with the currently utilized system is around 0.5 inches in diameter by 0.2 inches high. The terahertz imaging system inspects a test part by utilizing a transceiver to emit a pulse focused at the aluminum skin of the ET, which reflects it back to the transceiver where it is analyzed. The transceiver is scanned across the area of interest until a measurement has been taken at every location. Amplitude, time delay and frequency content are examined to note any discontinuities which may be the result of a void or other type of defect. The pulse currently utilized is in the millimeter wave regime. The void detection limit with this system is around 0.5 inches in diameter by 0.2 inches high. With increased interest in other causes of foam loss following the flight of Discovery in July 2005, laser shearography was added to the techniques used for inspecting ET foam. The shearography method records a sheared image of a laser speckle pattern projected on a test part before And after some sort of excitation. The resultant fringe pattern allows the slope of the out of plane displacement to be measured. For crushed and delaminated foam applications, a non-contact air coupled acoustic force is used to excite the surface of the foam. Regions without defects tend to respond differently to the sound energy than do regions with defects, generating a map of the foam integrity. Foam crushed to a depth of about 0.1 inches is detectable with shearography even after it has relaxed to its original shape.

Richter, Joel↗

Real-time Free-moving Active Coded Mask 3D Gamma-Ray Imaging

The ability to localize and map the distribution of gamma-ray emitting radionuclides in 3D has applications ranging from medical imaging to nuclear security. In the case of radiological source search and nuclear contamination remediation, the deployment of freely moving detection systems such as hand- held instruments or ground/aerial-based vehicles are critical in overcoming the inverse square law and complex shielding scenarios. Using contextual sensors, these systems can simultaneously generate 3D maps of the surrounding environment and track the position and orientation of the gamma-ray sensitive detectors in that environment. The fusion of contextual scene data and gamma-ray detector data to facilitate real-time 3D gamma-ray image reconstruction has been demonstrated with mobile HPGe and CdZnTe-based Compton cameras for gamma-ray energies ranging from a few hundred keV to several MeV. Here we apply this approach for lower energy (50-400 keV) gamma-rays, using a hand-held CdZnTe-based omnidirectional imaging system and an active coded mask imaging modality. Here, we present our approach to real-time reconstruction using a scene data constrained GPU- accelerated list-mode MLEM algorithm and show results from several measurements in the lab and in the field.

3D gamma-ray imaging↗

A compact neutron scatter camera for field deployment

Here, we describe a very compact (0.9 m high, 0.4 m diameter, 40 kg) battery operable neutron scatter camera designed for field deployment. Unlike most other systems, the configuration of the sixteen liquid-scintillator detection cells are arranged to provide omnidirectional (4π) imaging with sensitivity comparable to a conventional two-plane system. Although designed primarily to operate as a neutron scatter camera for localizing energetic neutron sources, it also functions as a Compton camera for localizing gamma sources. In addition to describing the radionuclide source localization capabilities of this system, we demonstrate how it provides neutron spectra that can distinguish plutonium metal from plutonium oxide sources, in addition to the easier task of distinguishing AmBe from fission sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗