Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “column”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Improved Design Tools for Surface Water and Standing Column Well Heat Pump Systems (DE-EE0002961)

Ground-source heat pump (GSHP) systems are perhaps the most widely used “sustainable” heating and cooling systems, with an estimated 1.7 million installed units with total installed heating capacity on the order of 18 GW. They are widely used in residential, commercial, and institutional buildings. Standing column wells (SCW) are one form of ground heat exchanger that, under the right geological conditions, can provide excellent energy efficiency at a relatively low capital cost. Closed-loop surface water heat pump (SWHP) systems utilize surface water heat exchangers (SWHE) to reject or extract heat from nearby surface water bodies. For building near surface water bodies, these systems also offer a high degree of energy efficiency at a low capital cost. However, there have been few design tools available for properly sizing standing column wells or surface water heat exchangers. Nor have tools for analyzing the energy consumption and supporting economics-based design decisions been available. The main contributions of this project lie in providing new tools that support design and energy analysis. These include a design tool for sizing surface water heat exchangers, a design tool for sizing standing column wells, a new model of surface water heat pump systems implemented in EnergyPlus and a new model of standing column wells implemented in EnergyPlus. These tools will better help engineers design these systems and determine the economic and technical feasibility.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Column Optimization Studies

Argonne National Laboratory (Argonne) is assisting Babcock and Wilcox Technical Services Group (BWTSG) in their efforts to develop an aqueous homogenous reactor (AHR) for the production of molybdenum-99 (Mo-99). Several different titania-based sorbents and alumina have been investigated as potential candidates for the development of a separation and recovery column for Mo-99 from a uranyl nitrate solution. A pure titania sorbent with 80-μm particles and 60-Å pores (S80) was initially chosen for the plant-scale column. However, ZirChrom Separations, Inc., discontinued their Sachtopore (pure titania) sorbent with 80-μm particles and 60-Å pores. As a result, Argonne has tested several other Sachtopore sorbents with different particle and pore sizes in an effort to find a replacement for S80. Initial Versatile Reaction Separation (VERSE) column designs suggest that S40 is the best replacement for S80; however, experimental results show that a significant amount of Mo does not adsorb on the S40 sorbent. S110 performs much better than S40, and the S110 column designs are final designs for the plant-scale operation and the mini- Medical Isotope Production System (mini-MIPS).

Youker, Amanda J.↗

Radiolytic Stability of the ABEC Column

A key reagent of the TechneGen generator (NorthStar) is an ABEC (aqueous biphasic extraction chromatographic) column that consists of polyethylene glycol (PEG) bonded to a polystyrene-divinylbenzene co-polymer bead. The ABEC column is highly selective for the pertechnetate ion under highly alkaline conditions, while molybdenum passes through the column. This study was focused on determining whether radiolysis of an ABEC column used multiple times in a 20-Ci (Mo-99) generator could affect the recovery of technetium due to a radiolytic degradation of PEG. Irradiations were performed using a Van de Graaff generator.

Tkac, Peter↗

Development and design of a multi-column experimental setup for Kr/Xe separation

As a precursor to FY-15 Kr/Xe separation testing, design modifications to an existing experimental setup are warranted. The modifications would allow for multi-column testing to facilitate a Xe separation followed by a Kr separation using engineered form sorbents prepared using an INL patented process. A new cooling apparatus capable of achieving test temperatures to -40° C and able to house a newly designed Xe column was acquired. Modifications to the existing setup are being installed to allow for multi-column testing and gas constituent analyses using evacuated sample bombs. The new modifications will allow for independent temperature control for each column enabling a plethora of test conditions to be implemented. Sample analyses will be used to evaluate the Xe/Kr selectivity of the AgZ-PAN sorbent and determine the Kr purity of the effluent stream following Kr capture using the HZ-PAN sorbent.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development Of ABEC Column For Separation Of Tc-99 From Northstar Dissolved Target Solution

Batch and column breakthrough experiments were performed to determine isotherms and mass-transfer parameters for adsorption of Tc on aqueous biphasic extraction chromatographic (ABEC) sorbent in two solutions: 200 g/L Mo, 5.1 M K + , 1 M OH - , and 0.1 M NO 3 - (Solution A) and 200 g/L Mo, 9.3 M K + , 5 M OH - , and 0.1 M NO 3 - (Solution B). Good agreement was found between the isotherm values obtained by batch and column breakthrough studies for both Solutions A and B. Potassium-pertechnetate intra-particle diffusivity on ABEC resin was estimated by VERSE simulations, and good agreement was found among a series of column-breakthrough experiments at varying flow velocities, column sizes, and technetium concentrations. However, testing of 10 cc cartridges provided by NorthStar with Solutions A and B did not give satisfactory results, as significant Tc breakthrough was observed and ABEC cartridge performance varied widely among experiments. These different experimental results are believed to be due to inconsistent preparation of the ABEC resin prior to packing and/or inconsistent packing.

36 MATERIALS SCIENCE↗

Tank Closure Cesium Removal Project CST Simulant Cesium Batch Contact Kinetics Test Results and Column Performance Predictions

To evaluate the cesium removal capabilities of the caustic-washed R9120-B version of crystalline silicotitanate (CST) ion exchange media from Savannah River Site (SRS) waste during Tank Closure Cesium Removal (TCCR) column processing, batch contact kinetics tests were performed at 23 °C in SRS Average simulant. Cesium loading kinetics data was also collected (in current and previous testing; King, et al., 2018a) using the same simulant for an older CST sample (IE- 911) which was caustic-washed by the vendor many years ago and was recently retrieved from drums stored at SRS. (Note that R9120-B and IE-911 are believed to be identical materials, after the R9120-B was caustic washed by SRNL, and differ only by particle size and manufacturing date, and thus can be considered different batches). Although cesium loading kinetics testing can be conducted more rigorously using dynamic column tests, the batch contact method requires less simulant and considerably less experimental effort. Average percent removal data for batch contact samples for the two CST batches are provided in Table ES-1. Faster cesium uptake was observed with IE-911, although the loading rates for the two media batches were similar. After 5.5 hours of CST contact, 81% cesium removal was observed with R9120-B versus 86% removal with IE-911. Although these differences are small, the trend is consistent across the timed results, with the larger bead material always loading slower. These seemingly small differences in percent removal are believed to have a large impact on the column performance. Cesium loading curves for the two CST batches are provided in Figure ES-1 below. Faster cesium loading with IE-911 CST is presumed to be associated with the smaller average particle diameter (408 μm mean volume diameter) versus R9120-B (572 μm diameter). Cesium loading kinetic data was needed to conduct column performance comparisons (i.e., model predictions) for the two CST batches.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank Closure Cesium Removal Ion Exchange Column CST Characterization: SRNL-STI-2024-00072 (Rev.0) pdf

Savannah River Mission Completion (SRMC) recently suspended operation of the Tank Closure Cesium Removal (TCCR) system which utilized an ion exchange (IX) process to remove radioactive cesium from waste supernate. During the demonstration phase, a total of three batches of Tank 10H dissolved salt waste were processed through the original TCCR columns. Subsequently, dissolved salt waste from Tank 9H was processed through TCCR in a phase referred to as TCCR 1A with four new IX columns. All eight columns have now been moved to Interim Safe Storage (ISS). For each batch processed through the TCCR IX columns, SRNL performed a number of analyses on surface and variable depth samples as well as batch equilibrium contact tests (BECT) to determine equilibrium loadings of Cs on the crystalline silicotitanate (CST) IX media. The BECTs were performed by lowering “teabags” containing ~0.1 g of CST each into the tank for a period of at least 10 days. The teabags were then retrieved and sent to SRNL for digestion and analysis.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigating Bacterial-Fungal Interactions using Fungal Highway Columns in Diverse Environments and Substrates

Bacterial-fungal interactions (BFIs) play an integral role in shaping microbial community composition, biogeochemical functions, spatial dynamics, and microbial dispersal. Mycelial networks created by filamentous fungi or other filamentous microorganisms (e.g., Oomycetes) act as 'fungal highways' that can be utilized by bacteria for transport throughout heterogeneous environments, greatly facilitating their mobility and granting them access to regions that may be challenging or impossible to reach on their own (e.g., due to air pockets within the soil). Several devices and experimental protocols have been created to study these fungal highways, including fungal highway columns. The fungal highway column designed by our group can be used for a variety of in situ or in vitro applications, as well as with diverse environmental and host-associated sample types. Herein, we describe the methods for performing experiments with these columns, including designing, printing, sterilizing, and preparing the devices. The options for analyzing data obtained from the use of these devices are also discussed here, and troubleshooting advice regarding potential pitfalls associated with experiments using fungal highway columns is offered. These devices can be used to gain a more comprehensive understanding of the diversity, mechanisms, and dynamics of fungal highway BFIs to provide valuable insights into the structural and functional dynamics within complex environments (e.g., soils) and across diverse habitats in which bacteria and fungi co-exist.

59 BASIC BIOLOGICAL SCIENCES↗

Calibrating column density tracers with gamma-ray observations of the ρ ophiuchi molecular cloud

Diffuse gamma-ray emission from interstellar clouds results largely from cosmic ray (CR) proton collisions with ambient gas, regardless of the gas state, temperature, or dust properties of the cloud. The interstellar medium is predominantly transparent to both CRs and gamma-rays, so GeV emission is a unique probe of the total gas column density. The gamma-ray emissivity of a cloud of known column density is then a measure of the impinging CR population and may be used to map the k-scale CR distribution in the Galaxy. To this end, we test a number of commonly used column density tracers to evaluate their effectiveness in modeling the GeV emission from the relatively quiescent, nearby ρ Ophiuchi molecular cloud. We confirm that both H i and an appropriate H{sub 2} tracer are required to reproduce the total gas column densities probed by diffuse gamma-ray emisison. We find that the optical depth at 353 GHz (τ{sub 353}) from Planck best reproduces the gamma-ray data overall, based on the test statistic across the entire region of interest, but near-infrared stellar extinction also performs very well, with smaller spatial residuals in the densest parts of the cloud.

79 ASTRONOMY AND ASTROPHYSICS↗

A New Two-fluid Radiation-hydrodynamical Model for X-Ray Pulsar Accretion Columns

Previous research centered on the hydrodynamics in X-ray pulsar accretion columns has largely focused on the single-fluid model, in which the super-Eddington luminosity inside the column decelerates the flow to rest at the stellar surface. This type of model has been relatively successful in describing the overall properties of the accretion flows, but it does not account for the possible dynamical effect of the gas pressure. On the other hand, the most successful radiative transport models for pulsars generally do not include a rigorous treatment of the dynamical structure of the column, instead assuming an ad hoc velocity profile. In this paper, we explore the structure of X-ray pulsar accretion columns using a new, self-consistent, “two-fluid” model, which incorporates the dynamical effect of the gas and radiation pressures, the dipole variation of the magnetic field, the thermodynamic effect of all of the relevant coupling and cooling processes, and a rigorous set of physical boundary conditions. The model has six free parameters, which we vary in order to approximately fit the phase-averaged spectra in Her X-1, Cen X-3, and LMC X-4. In this paper, we focus on the dynamical results, which shed new light on the surface magnetic field strength, the inclination of the magnetic field axis relative to the rotation axis, the relative importance of gas and radiation pressures, and the radial variation of the ion, electron, and inverse-Compton temperatures. The results obtained for the X-ray spectra are presented in a separate paper.

79 ASTRONOMY AND ASTROPHYSICS↗

Dynamical and Radiative Properties of X-Ray Pulsar Accretion Columns: Phase-averaged Spectra

The availability of the unprecedented spectral resolution provided by modern X-ray observatories is opening up new areas for study involving the coupled formation of the continuum emission and the cyclotron absorption features in accretion-powered X-ray pulsar spectra. Previous research focusing on the dynamics and the associated formation of the observed spectra has largely been confined to the single-fluid model, in which the super-Eddington luminosity inside the column decelerates the flow to rest at the stellar surface, while the dynamical effect of gas pressure is ignored. In a companion paper, we have presented a detailed analysis of the hydrodynamic and thermodynamic structure of the accretion column obtained using a new self-consistent model that includes the effects of both gas and radiation pressures. In this paper, we explore the formation of the associated X-ray spectra using a rigorous photon transport equation that is consistent with the hydrodynamic and thermodynamic structure of the column. We use the new model to obtain phase-averaged spectra and partially occulted spectra for Her X-1, Cen X-3, and LMC X-4. We also use the new model to constrain the emission geometry, and compare the resulting parameters with those obtained using previously published models. Our model sheds new light on the structure of the column, the relationship between the ionized gas and the photons, the competition between diffusive and advective transport, and the magnitude of the energy-averaged cyclotron scattering cross-section.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration of the Total Carbon Column Observing Network using Aircraft Profile Data

The Total Carbon Column Observing Network (TCCON) produces precise measurements of the column average dry-air mole fractions of CO{sub 2}, CO, CH{sub 4}, N{sub 2}O and H{sub 2}O at a variety of sites worldwide. These observations rely on spectroscopic parameters that are not known with sufficient accuracy to compute total columns that can be used in combination with in situ measure ments. The TCCON must therefore be calibrated to World Meteorological Organization (WMO) in situ trace gas measurement scales. We present a calibration of TCCON data using WMO-scale instrumentation aboard aircraft that measured profiles over four TCCON stations during 2008 and 2009. The aircraft campaigns are the Stratosphere-Troposphere Analyses of Regional Transport 2008 (START-08), which included a profile over the Park Falls site, the HIAPER Pole-to-Pole Observations (HIPPO-1) campaign, which included profiles over the Lamont and Lauder sites, a series of Learjet profiles over the Lamont site, and a Beechcraft King Air profile over the Tsukuba site. These calibrations are compared with similar observations made during the INTEX-NA (2004), COBRA-ME (2004) and TWP-ICE (2006) campaigns. A single, global calibration factor for each gas accurately captures the TCCON total column data within error.

54 ENVIRONMENTAL SCIENCES↗

Small-Column Ion Exchange Testing of Spherical Resorcinol-Formaldehyde

Ion exchange using the Spherical Resorcinol-Formaldehyde (SRF) resin has been selected by the U.S. Department of Energy’s Office of River Protection (DOE-ORP) for use in the Pretreatment Facility (PTF) of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) and for potential application in an at-tank deployment. Numerous studies have shown the SRF resin to be effective for removing Cs-137 from a wide variety of actual and simulated tank waste supernatants. Prior work focused primarily on the loading behavior for 5 M sodium (Na) solutions at 25°C and the eluting behavior of the loaded SRF resin with virgin 0.5 M HNO3. Recent proposed changes to the process baseline indicate that loading may include a broader range of sodium molarities (2 to 8 M) and higher temperatures (50°C) to alleviate post-filtration precipitation issues. In addition, elution will likely utilize variable-strength recycled nitric acid containing trace amounts of Cs-137. Cesium ion exchange loading and elution curves were generated for a 5 M Na, 2.4E-05 M Cs loading solution traced with Cs-134 followed by elution with variable HNO3 (0.02, 0.07, 0.15, 0.23, and 0.28 M) containing variable CsNO3 (5.0E-09, 5.0E-08, and 5.0E-07 M) and traced with Cs-137. The ion exchange system consisted of a pump, tubing, process solutions, and a single, small (~15 mL) bed of SRF resin with a water-jacketed column for temperature-control. The columns were loaded with approximately 250 bed volumes (BVs) of feed solution at 45°C and at 1.5 to 12 BV per hour (0.15 to 1.2 cm/min). The columns were then eluted with approximately 25 BVs of HNO3 processed at 25°C and at 1.4 BV/hr. The two independent tracers allowed analysis of the on-column cesium interaction between the loading and elution solutions. The objective of these tests was to improve the correlation between the spent resin cesium content and cesium leached out of the resin in subsequent loading cycles (cesium bleed), to help establish acid strength and purity requirements.

Brown, Garrett N.↗

Space Charge Compensation Using Electron Columns and Electron Lenses at IOTA

The ability to transport a high current proton beam in a ring is ultimately limited by space charge effects. Two novel ways to overcome this limit in a proton ring are by adding low energy, externally matched electron beams (electron lens, e-lens), and by taking advantage of residual gas ionization induced neutralization to create an electron column (e-column). Theory predicts that an appropriately confined electrons can completely compensate the space charge through neutralization, both transversely and longitudinally. In this report, we will discuss the current status of the Fermilab’s e-lens experiment for the space charge compensation. In addition, we will show how the IOTA e-column compensates space charge with theWARP simulations. The dynamics of proton beams inside of the e-column is understood by changing the magnetic field of a solenoid, the voltage on the electrodes, and the vacuum pressure, and by looking for electron accumulation, as well as by considering various beam dynamics in the IOTA ring.

43 PARTICLE ACCELERATORS↗

Full-Column Greenhouse Gas Sampling Field Campaign Report

The AirCore is a balloon-borne sampler patented and developed at the National Oceanic and Atmospheric Administration (NOAA) Earth System Research Laboratory (ESRL) Global Monitoring Division (GMD) (Tans 2009) that has the capability to provide full-column measurements of greenhouse gases and other trace gas species (Karion et al. 2010). It consists of a long, coated stainless steel tube that is filled with a known trace gas mixture prior to balloon launch (Figure 1). The AirCore is opened at one end prior to balloon launch and, as the balloon ascends, it evacuates to ambient pressure. At 30 km, the balloon is cut away and the AirCore descends via parachute, now capturing an atmospheric air sample or “core” of air from 30 km to the surface due to the pressure gradient between the evacuated AirCore and the environment. Upon landing, the AirCore is closed, preserving the air sample collected in-flight. Because diffusion acts slowly on the AirCore sample in the four hours that it typically takes to launch, retrieve, and analyze the sample, it is possible to capture more than 100 discrete samples in the atmospheric profile collected by the AirCore. Currently, the AirCore is analyzed for carbon dioxide (CO2), methane (CH4), and carbon monoxide (CO) at NOAA/ESRL GMD, but the sample collected can be measured on a variety of other analyzers to obtain full-column profiles of other trace gas species. Unlike routine aircraft measurements, the AirCore provides a low-cost alternative to atmospheric profiling and captures >95% of the atmospheric column. It has a variety of applications, including to full-column greenhouse and trace gas sampling and monitoring, to satellite and remote-sensing instrumentation evaluation, and to tropospheric and stratospheric model evaluation.

Greenhouse gases, Southern Great Plains, balloon-b↗

Tests of isotopic separation efficiency of palladium packed columns

The isotopic effect of palladium has been applied in different ways to separate hydrogen isotopes for many years. At Savannah River Site palladium deposited on kieselguhr (Pd/k) is used in a thermal cycling absorption process (TCAP) to purify tritium for over ten years. The need to design columns for different throughputs and the desire to advance the performance of TCAP created the need to evaluate different column designs and packing materials for their separation efficiency. In this work, columns with variations in length, diameter and metal foam presence were tested using an isotope displacement method. A simple computer model was also developed to calculate the number of theoretical separation stages based on the test results. The effects of column diameter, metal foam presence and gas flow rate were identified. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Simulation of In Situ Bioremediation of Chromium (VI) Using Consortium Cultures and Column Studies - 19357

Chromium contaminated soil and ground water has become a serious problem caused by the rapid expansion of industries, leading to direct or indirect discharge of Cr(VI). The conventional methods that include pump and treat result into toxic byproducts and residual. Cr(VI) reducing bacteria in the contrary have been envisioned as an economically and ecologically friendly method to treat contaminated sites. Biological Cr(VI) reduction processes include biotransformation, biosorption which involve detoxification/ removal of hazardous substances and bioaccumulation. A continuous flow column system for Cr(VI) reduction was investigated in three different treatments and the control, using dried sludge and soil from target site. Cultures identified using effluent samples in the 16S rRNA sequencing showed a prominent of Exiguobacterium aestuarii species as it was identified from all column systems. Other cultures that showed 100% query cover included; Enterobacter aerogenes, Enterobacter kobei and Pseudomonas aeruginosa. More than 90% of Cr(VI) reduction was observed in all columns over a 60 day period at 40 mgL{sup -1}. Cr(VI) was reduced from 38.12 mgL{sup -1} to 0.39 mgL{sup -1}. A more unstable profile was observed at 60 mgL{sup -1} over 60 days. Subsequently, there was near complete reduction from System 1 and 3 of 1.152 mgL{sup -1} and 1.215 mgL{sup -1} Cr(VI) concentration, respectively. A Cr(VI) reduction profile along the column proved to be uniform at assumed quasi-steady state from the influent to the effluent for both 40 and 60 mgL{sup -1} Cr(VI) concentration. Biological remediation strategies for Cr(VI) contaminated soil and groundwater is an emerging field that has been proposed to successfully treat Cr(VI) contaminated sites using Cr(VI) reduction species of bacteria. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fundamental Study of Migration Behavior of Cesium under the Unsaturated Condition through One-dimensional Column Simulating Soil around the Disposal Site - 20262

Using a packed column simulating unsaturated soil around the disposal site, flow experiments of cesium ions were conducted in order to examine the difference of retardation effect between saturated and unsaturated conditions. The column was packed with silica sand particles of 350 μm in diameter. In this study, it was confirmed that the X-ray CT images of the column showed that the water saturation was mostly uniform within the column under unsaturated conditions. The values of water saturation in the flow experiments of Cs ions were in a range from 0.85 to 0.93. The retardation coefficients(Rd) were estimated by applying the one-dimensional advection-dispersion equation to the experimental results. The comparison of the Rd-values estimated experimentally and theoretically showed that the experimental value was estimated to be larger than the theoretical value. This means that the theoretical value evaluated through a conventional method would bring the conservative value as an apparent retardation coefficient, at least when the flow direction is from top to bottom as shown in this study. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗