Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “collimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Gamma-ray spectroscopic characterization of long, rapidly-grown KSr 2 I 5 :Eu crystals

Collimation and volumetric studies were done to evaluate the gamma-ray spectroscopic performance of KSr 2 I 5 :Eu scintillators grown via the vertical Bridgman method. To demonstrate practical crystal growth for large-scale production, Ø1 in. × 6 in. long crystals were grown using fast pulling rates up to 5 mm/h and short cooling times. The long crystals were sectioned into shorter Ø1 in. cylinders to investigate sample-to-sample variation of scintillation properties, the effects of self-absorption and scintillation non-uniformity using different gamma-ray excitation configurations. The best light output and energy resolution achieved for the largest volume and aspect ratio crystals (60 cm 3 Ø1 in x 4.7 in. long) were 53,500 ph/MeV and 4.6% at 662 keV. Finally, we produced eight Ø1 in. × 1 in. (12.5 cm 3 ) cylindrical samples, four from each boule, with energy resolutions between 3.1%-3.5% at 662 keV.

36 MATERIALS SCIENCE↗

A modular apparatus for use in high-precision measurements of parity violation in polarized eV neutron transmission

We describe a modular apparatus for use in parity-violation measurements in epithermal neutron–nucleus resonances with high instantaneous neutron fluxes at the Manuel Lujan Jr. Neutron Scattering Center at Los Alamos National Laboratory. This apparatus is designed to conduct high-precision measurements of the parity-odd transmission asymmetry of longitudinally polarized neutrons through targets containing nuclei with p-wave neutron–nucleus resonances in the 0.1–10 eV energy regime and to accommodate a future search for time reversal violation in polarized neutron transmission through polarized nuclear targets. The apparatus consists of an adjustable neutron and gamma collimation system, a 3 He- 4 He ion chamber neutron flux monitor, two identical cryostats for target cooling, an adiabatic eV-neutron spin flipper, a near-unit efficiency 6 Li- 7 Li scintillation detector operated in current mode, a flexible CAEN data acquisition system, and a neutron spin filter based on spin-exchange optical pumping of 3 He gas. We describe the features of the apparatus design devoted to the suppression of systematic errors in parity-odd asymmetry measurements. We describe the configuration of the apparatus used to conduct a precision measurement of parity violation at the 0.7 eV p-wave resonance in 139 La which employs two identical 139 La targets, one to polarize the beam on the p-wave resonance using the weak interaction and one to analyze the polarization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma-ray spectroscopy using angular distribution of Compton scattering

We present a novel method to perform gamma-ray spectroscopy suitable for extreme pileup situations, wherein traditional pulse-height spectroscopy is infeasible or impractical. One example of such application is spectral characterization of intense laser-based radiation sources that employ laser wakefield acceleration, in which a large number of photons can be produced in a well-collimated beam on a picosecond or shorter timescale. The method relies on the angularly-resolved calorimetric measurement of Compton scattering. The probability for a photon to undergo Compton scattering into a given solid angle is a function of its energy and is described by the Klein–Nishina formula. By first Compton scattering the incident beam and then measuring the total energies deposited in multiple detectors placed at various scattering angles, the incident beam energy spectrum can be reconstructed without resolving the individual events in detectors. Here, we compare the performance of an maximum likelihood expectation maximization algorithm with that of an artificial neural network to measure the energy spectrum of a beam of monoenergetic gamma rays from 137Cs decay. We demonstrate that the method can be used to reconstruct the characteristic inverse Compton scattering spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-modal tomographic imaging system for poolside characterization of nuclear test fuels: Design considerations and studies

Testing and qualification of advanced nuclear fuels involves an iterative process of prototyping, in-pile irradiation testing, and in-situ or ex-situ examination. Fuel restructuring and fission product migration during burnup are among the most important aspects of fuel evolution that affect several important performance characteristics such as heat removal, accident tolerance, and fission product retention. Pool-side non-destructive characterization techniques provide fuel developers with tools to understand fuel evolution at different points of burnup. A design for a compact, submersible, and multi-modal gamma-ray tomography system for imaging irradiated nuclear fuel is presented here. Detector selection, collimator geometry and fabrication, mechanical design, imaging protocol and acquisition speed are discussed. Modeling calculations show that sub-millimeter resolution can be achieved in both transmission computed tomography images as well as in emission computed tomography images in a matter of hours. Several design compromises and fabrication challenges are discussed which should be taken into consideration for future submersible gamma-ray tomography instruments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Novel X-ray scanning technique for in-situ alignment of photo-detectors in the MEGII calorimeter

Here, we describe and show results of a novel technique to measure with high precision the positions of photodetectors installed in the upgraded liquid xenon calorimeter of the MEG II experiment. The measurement was done by detecting the signal in individual photo-detectors as the front surface of the calorimeter was scanned in axial (Z) and azimuthal (Φ) directions with a precisely controlled, thin, collimated beam of X-rays obtained from a 57 CoX-ray source. The measurements were made when the calorimeter was cold and operational, under which conditions they could not otherwise be made. This technique is used to check for changes in the photodetector positions due to the effects of cooling and thermal cycling of the support structure and to provide a reference between the positions of the operational photodetectors and alignment markers on the cryostat exterior. The use of an essentially monochromatic X-ray source allowed ancillary measurements of photodetector properties, including pulse shape, relative gain, and variation in response over the photodetector surface. Measurement uncertainties below 0.6mm in Z and 0.7 mrad in Φ have been achieved, well within the requirements for the MEG II performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uranium measurements in the field using high-resolution cadmium zinc telluride detectors

A new generation of cadmium zinc telluride (CZT) detectors has become available and is being evaluated by the International Atomic Energy Agency (IAEA) for safeguards verifications in the field. The new CZT detector, model M400, is a room temperature spectrometer manufactured by H3D, Inc. The M400 demonstrates superior energy resolution, effective isotope identification capabilities, and convenient usability features when tested in a controlled laboratory environment. These characteristics define the M400 as a potential platform for IAEA field detection applications, which could become suitable for nuclear material characterization (e.g., enrichment verification) and nuclear safeguards missions. The capabilities of gamma spectrometry codes including Fixed energy, Response function Analysis with Multiple efficiencies (FRAM) from Los Alamos National Laboratory, CZT for Uranium (CZTU) from Lawrence Livermore National Laboratory, and Gamma Detector Response and Analysis Software (GADRAS) from Sandia National Laboratories were adapted for M400 spectra, and the performance of the codes has been validated. This was reported in a prior work. To further validate the performance of the high-energy resolution CZT detector and the isotopic analysis codes, a field measurement campaign consisting of uranium hexafluoride (UF 6 ) cylinder measurements was conducted at a fuel fabrication facility. A total of 34 Type 30B cylinders containing UF6 were measured using three different M400 CZT detectors. Each detector was outfitted with a custom rectangular collimator and shield made out T-Flex®, a tungsten-impregnated polymer. Measurements were performed at three different locations of the cylinder, ensuring that the measurement geometry satisfied the infinite thickness criterion. The spectra from the M400 CZT were analyzed using the code General Enrichment Meter (GEM). For analyzing the gamma-ray spectra from UF 6 cylinder, the GEM code is the appropriate tool since it relies only on the gamma-ray emissions from 235 U and not from other isotopes. Results from the spectral analysis were compared with the known abundance of 235 U in the cylinders, as well as with the International Target Values 2020 (ITV2020). The suitability of the different underlying techniques used by the various codes for UF 6 analysis is discussed. The challenges of measuring UF 6 contained in cylinders and mitigation strategies are highlighted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of ray-tracing simulations to confirm performance of the GP-SANS instrument at the High-Flux Isotope Reactor

The CG-2 beamline at the High Flux Isotope Reactor (HFIR) exhibits a notable discrepancy between observed count rates and the count rates we would expect based on a Monte-Carlo neutron ray-trace simulation. These simulations consistently predict count rates approximately five times greater than those observed in four separate experimental runs involving different instrument configurations. This discrepancy suggests that certain factors are causing losses in measurements that are not adequately accounted for in the simulation, in particular guide reflectivity or misalignment. To investigate these discrepancies, a high-dimensional simulation parameter approach is applied in order to understand the losses. Region of Interest (ROI) groups along the instrument are assigned to different surfaces of the guide components within the simulation. This allows the parameters of those guide components to be varied as a group to minimize the complexity of the search space. The result is an optimization of simulation parameters using an iterative scheme that aims to minimize the difference between experimentally measured count rates and simulated count rates across all tested collimator combinations. This proposed methodology holds the potential to reveal previously unrecognized sources of intensity loss in the CG-2 beamline at HFIR and improve the accuracy of simulations, leading to enhanced understanding and performance of the beamline for various scientific applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Characterizing the Experiment for Calibration with Uranium (Excalibur) neutron source for use in warhead verification

Neutron sources can play a variety of roles in warhead verification. For transmission radiography, a source of directed high energy neutrons is required, while for applications to detect fissile isotopes, sub-MeV neutrons are preferred. The Excalibur (Experiment for Calibration with Uranium) neutron source has been built and used in a variety of verification-related experiments. Excalibur is based on a commercial deuterium-tritium neutron generator specified and measured to be capable of producing 14 MeV neutrons at rates of up to 8.2 × 10 8 neutrons/s. Here, the generator is enclosed in a carbon-steel 32" diameter, 23.62" high carbon-steel cylinder that moderates the mean neutron energy to under 500 keV. This, in turn, is encased in 5%-borated polyethylene such that the entire assembly is a 48" x 48" box that is 30" tall. For radiographic applications, a narrow, tapered channel in the steel and polyethylene allows 14 MeV neutrons to stream directly from the generator to a test object. Its collimating capability is demonstrated by measuring the neutron flux profile. In the moderated mode of operation, the generator is fully enclosed in the steel, but a large section of the polyethylene is removed, providing a flux of sub-MeV neutrons from a wide range of angles. Neutron angular and spectral measurements using both a nested neutron spectrometer and a commercial liquid scintillator coupled with a 3 He detector show the expected softer neutron spectrum in moderated mode in good agreement with MCNP6 calculations. The gamma-ray spectrum from Excalibur is also in good agreement with MCNP modeling. Based on these findings, the future application of Excalibur in its two configurations is discussed.

Fissile material detection↗

Commissioning of the Advanced Rare Isotope Separator ARIS at FRIB

The Facility for Rare Isotope Beams (FRIB) at Michigan State University (MSU) consists of a newly constructed linear accelerator and fragment separator that are designed for enhanced production rates of rare isotopes for use in research and other societal applications. Recent activities through to August 2022 took place to commission the Advanced Rare Isotope Separator (ARIS) and carry out the first experiments. This followed commissioning of the newly constructed linac that is designed to provide orders of magnitude higher beam power than the previously coupled cyclotrons. This required that more advanced target, beam dump, and collimation systems of the new separator be designed and constructed to sustain unprecedented conditions by heavy ion beams. Commissioning with ~1 kW beams began recently and results from activities that began in late 2021 are reported here. Comparisons between the previous and current facilities are provided.

43 PARTICLE ACCELERATORS↗

FLArE up dark sectors with EM form factors at the LHC forward physics facility

Despite being mostly secluded, dark sector particles may feebly interact with photons via a small mass-dimension 4 millicharge, a mass-dimension 5 magnetic and electric dipole moment, or a mass-dimension 6 anapole moment and charge radius. If sufficiently light, the LHC may produce an intense and collimated beam of these particles in the far forward direction. We study the prospects of searching for such dark sector particles with electromagnetic form factors via their electron scattering signature in the Forward Liquid Argon Experiment (FLArE) at the Forward Physics Facility (FPF). We find that FLArE can provide new probes of sub-GeV dark particles with dipole moments and strong sensitivities for millicharged particles in the 100 MeV to 100 GeV region. This complements other search strategies using scintillation signatures or dark matter direct detection and allows for probing strongly interacting dark matter motivated by the EDGES anomaly. Along with the FORMOSA detector, this leads to a very versatile and leading experimental program in the search for millicharged particles in the FPF.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Wavefront preserving X-ray optics for Synchrotron and Free Electron Laser photon beam transport systems

We report in the last two decades, after the first light from the new Free Electron Lasers, either in the UV (FLASH and FERMI@Elettra) or X-ray (LCLS and SACLA), more and more new diffraction limited sources have been either constructed or planned. Third generation storage rings are upgraded to provide a more collimated, brighter, and coherent light for the next generation experimental techniques. X-ray optics are the bridge between the light sources and the experimental stations. They are the key to the success of advanced experiments but also the potential bottleneck preventing the exploitation of the full characteristics of the source. The beam degradation originated by any mirror defect (either from mirror polishing or from contamination) is amplified with a coherent source. Delivering diffraction-limited spots, including the option for variable spot sizes in and out of focus, requires the control of the surface of the optics at the 1 nm rms level, if not better. At LCLS, only very recently an almost perfectly uniform beam out of focus has been obtained in the hard X-rays. It has been obtained after two 1-m long mirrors with 0.5 nm rms shape precision (after installation). Those mirrors were not readily available just a decade ago. But, thanks to the pioneering work performed at the Osaka University, those optics are now commercially available with arbitrary tangential profiles. This new generation of mirrors permits achieving unprecedented results. However, they do not remove all road blocks to a perfect photon transport system. Instead, they highlighted the critical importance of mirror mounting, handling of the thermal deformation, and the need of advanced diagnostics to properly exploit all the new potentiality of these optics. Besides the need of “perfect” mirrors, other aspects of the beamline design and elements may impact the quality of the beam in the experimental station, from the lack of blaze gratings to the need of advanced simulation tools, just to cite two. In this article, after a brief historical excursus, we will present the current state of the art of mirrors, gratings, crystals, lenses, diagnostics, and simulation tools. The main problems yet to solve and a look ahead at what would be achievable in the next decade will give the reader an idea on the search for an almost ideal photon transport system and how the path toward experiments, not conceivable today, will unfold.

47 OTHER INSTRUMENTATION↗

IK-Frag: Frag data generator for the PHITS simulation with the inverse kinematic reaction producing a focused neutron beam

IK-Frag has been developed for the creation of the nuclear cross-section data format, which is named frag data and can be used in PHITS, a Monte Carlo simulation code. IK-Frag focuses on the inverse kinematic reactions between a lithium or beryllium ion and a proton target. These reactions achieve naturally collimated neutrons and potentially reduce the necessity of radiation shielding. IK-Frag enables PHITS users to conduct simulations for the inverse kinematic reactions. The present software aims to contribute to future development of the neutron source system using the inverse kinematic reactions.

43 PARTICLE ACCELERATORS↗

Structure and dynamics of magneto-inertial, differentially rotating laboratory plasmas

We present a detailed characterization of the structure and evolution of differentially rotating plasmas driven on the MAGPIE pulsed-power generator (1.4 MA peak current, 240 ns rise time). The experiments were designed to simulate physics relevant to accretion discs and jets on laboratory scales. A cylindrical aluminium wire array Z pinch enclosed by return posts with an overall azimuthal off-set angle was driven to produce ablation plasma flows that propagate inwards in a slightly off-radial trajectory, injecting mass, angular momentum and confining ram pressure to a rotating plasma column on the axis. However, the plasma is free to expand axially, forming a collimated, differentially rotating axial jet that propagates at ${\approx }100\,{\rm km}\,{\rm s}^{-1}$ . The density profile of the jet corresponds to a dense shell surrounding a low-density core, which is consistent with the centrifugal barrier effect being sustained along the jet's propagation. We show analytically that, as the rotating plasma accretes mass, conservation of mass and momentum implies plasma radial growth scaling as $r \propto t^{1/3}$ . As the characteristic moment of inertia increases, the rotation velocity is predicted to decrease and settle on a characteristic value ${\approx }20\,{\rm km}\,{\rm s}^{-1}$ . We find that both predictions are in agreement with Thomson scattering and optical self-emission imaging measurements.

Valenzuela-Villaseca, V. (ORCID:0000000167721441)↗

3D Volumetric Structural Hierarchy Induced by Colloidal Polymerization of a Quantum-Dot Ionic Liquid Monomer Conjugate

Hierarchically structured emissive quantum dot (CdS/CdSe) poly(ionic liquid) composites are synthesized through colloidal polymerization within a lyotropic liquid crystal, yielding a solvent-responsive nanoparticle (NP) composite possessing four ordered structural motifs. The composite is prepared by coassembling an amphiphilic ionic liquid (IL) monomer, 3-decyl-1-vinylimidazolium chloride, [C 10 VIm + ][Cl - ], and IL monomer, 3-(10-mercaptodecyl)-1-vinylimidazolium bromide surface-functionalized quantum dots, QD-[SC 10 VIm + ][Br - ], in 30 wt % water. Photo (UV)-initiated free radical polymerization serves to form a colloidal copolymer that collimates pairs of QDs within the core of large cylinders (average diameter = 21 nm and length = 422 nm), as evidenced by ultrasmall-angle X-ray scattering (USAXS). As revealed by continuous wave terahertz multispectral reconstructive 3-D imaging, the subsurface structure along the cylinder axis undergoes dynamic rearrangement between 2D hexagonal and cubic packing. The polymerized ionic liquid sheath surrounding the QDs is composed of concentric hexagonally perforated lamellae (HPL) with an interlamellar repeat distance of 3 nm, as determined by small-angle X-ray scattering (SAXS). The encapsulated QDs retain crystallinity (TEM and WAXS) and emission characteristics (photoluminescence spectroscopy, lambda(EM) = 638 nm). Phenomenological time-dependent Ginzburg-Landau calculations verify the mesoscale cylinders arise from the topological constraints imposed by the in-plane perforations of the polymerized ionic liquid as it wraps around the hard (unmalleable) spherical QDs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Caltech Lab Experiments and the Insights They Provide Into Solar Corona Phenomena

A comprehensive overview of two decades of Caltech experiments relevant to solar corona physics is presented. The extent to which the experiments scale to the solar corona, the basic configurations and operation, and the importance of the magnetic force J × B common to all the experiments is discussed. Summaries are given of the various configurations used, the main observations, and interpretations of these observations, including new models developed to provide these interpretations. Topics include observations and explanations for flux rope self-collimation, axial flows along flux ropes, eruption of arched flux ropes, strapping magnetic fields that inhibit eruption, the torus instability, and effects such as X-ray emission of a kink-driven secondary Rayleigh-Taylor instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron-upscattering enhancement of the triple-alpha process

Abstract The neutron inelastic scattering of carbon-12, populating the Hoyle state, is a reaction of interest for the triple-alpha process. The inverse process (neutron upscattering) can enhance the Hoyle state’s decay rate to the bound states of 12 C, effectively increasing the overall triple-alpha reaction rate. The cross section of this reaction is impossible to measure experimentally but has been determined here at astrophysically-relevant energies using detailed balance. Using a highly-collimated monoenergetic beam, here we measure neutrons incident on the Texas Active Target Time Projection Chamber (TexAT TPC) filled with CO 2 gas, we measure the 3 α -particles (arising from the decay of the Hoyle state following inelastic scattering) and a cross section is extracted. Here we show the neutron-upscattering enhancement is observed to be much smaller than previously expected. The importance of the neutron-upscattering enhancement may therefore not be significant aside from in very particular astrophysical sites (e.g. neutron star mergers).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma electron acceleration driven by a long-wave-infrared laser

Laser-driven plasma accelerators provide tabletop sources of relativistic electron bunches and femtosecond x-ray pulses, but usually require petawatt-class solid-state-laser pulses of wavelength λ L ~ 1 μm. Longer-λ L lasers can potentially accelerate higher-quality bunches, since they require less power to drive larger wakes in less dense plasma. Here, we report on a self-injecting plasma accelerator driven by a long-wave-infrared laser: a chirped-pulse-amplified CO 2 laser (λ L ≈ 10 μm). Through optical scattering experiments, we observed wakes that 4-ps CO 2 pulses with < 1/2 terawatt (TW) peak power drove in hydrogen plasma of electron density down to 4 × 10 17 cm –3 (1/100 atmospheric density) via a self-modulation (SM) instability. Shorter, more powerful CO 2 pulses drove wakes in plasma down to 3 × 10 16 cm –3 that captured and accelerated plasma electrons to relativistic energy. Collimated quasi-monoenergetic features in the electron output marked the onset of a transition from SM to bubble-regime acceleration, portending future higher-quality accelerators driven by yet shorter, more powerful pulses.

43 PARTICLE ACCELERATORS↗

Quantitative imaging and automated fuel pin identification for passive gamma emission tomography

Compliance of member States to the Treaty on the Non-Proliferation of Nuclear Weapons is monitored through nuclear safeguards. The Passive Gamma Emission Tomography (PGET) system is a novel instrument developed within the framework of the International Atomic Energy Agency (IAEA) project JNT 1510, which included the European Commission, Finland, Hungary and Sweden. The PGET is used for the verification of spent nuclear fuel stored in water pools. Advanced image reconstruction techniques are crucial for obtaining high-quality cross-sectional images of the spent-fuel bundle to allow inspectors of the IAEA to monitor nuclear material and promptly identify its diversion. In this work, we have developed a software suite to accurately reconstruct the spent-fuel cross sectional image, automatically identify present fuel rods, and estimate their activity. Unique image reconstruction challenges are posed by the measurement of spent fuel, due to its high activity and the self-attenuation. While the former is mitigated by detector physical collimation, we implemented a linear forward model to model the detector responses to the fuel rods inside the PGET, to account for the latter. The image reconstruction is performed by solving a regularized linear inverse problem using the fast-iterative shrinkage-thresholding algorithm. We have also implemented the traditional filtered back projection (FBP) method based on the inverse Radon transform for comparison and applied both methods to reconstruct images of simulated mockup fuel assemblies. Higher image resolution and fewer reconstruction artifacts were obtained with the inverse-problem approach, with the mean-square-error reduced by 50%, and the structural-similarity improved by 200%. We then used a convolutional neural network (CNN) to automatically identify the bundle type and extract the pin locations from the images; the estimated activity levels finally being compared with the ground truth. The proposed computational methods accurately estimated the activity levels of the present pins, with an associated uncertainty of approximately 5%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗