Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cold injection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Combustion of hydrogen injected into a supersonic airstream (a guide to the HISS computer program)

A computer program based on a finite-difference, implicit numerical integration scheme is described for the prediction of hydrogen injected into a supersonic airstream at an angle ranging from normal to parallel to the airstream main flow direction. Results of calculations for flow and thermal property distributions were compared with 'cold flow data' taken by NASA/Langley and show excellent correlation. Typical results for equilibrium combustion are presented and exhibit qualitatively plausible behavior. Computer time required for a given case is approximately one minute on a CDC 7600. A discussion of the assumption of parabolic flow in the injection region is given which demonstrates that improvement in calculation in this region could be obtained by a partially-parabolic procedure which has been developed. It is concluded that the technique described provides an efficient and reliable means for analyzing hydrogen injection into supersonic airstreams and the subsequent combustion.

Dyer, D. F.↗

A novel path to runaway electron mitigation via deuterium injection and current-driven MHD instability

Relativistic electron (RE) beams at high current density (low safety factor, qa) yet very low free-electron density accessed with D2 secondary injection in the DIII-D and JET tokamak are found to exhibit large-scale MHD instabilities that benignly terminate the RE beam. In JET, this technique has enabled termination of MA-level RE currents without measurable first-wall heating. This scenario thus offers an unexpected alternate pathway to achieve RE mitigation without collisional dissipation. Benign termination is explained by two synergistic effects. First, during the MHD-driven RE loss events both experiment and MHD orbit-loss modeling supports a significant increase in the wetted area of the RE loss. Second, as previously identified at JET and DIII-D, the fast kink loss timescale precludes RE beam regeneration and the resulting dangerous conversion of magnetic to RE kinetic energy. During the termination, the RE kinetic energy is lost to the wall, but the current fully transfers to the cold bulk thus enabling benign Ohmic dissipation of the magnetic energy on longer timescales via a conventional current quench. Hydrogenic (D2) secondary injection is found to be the only injected species that enables access to the benign termination. D2 injection: 1) facilitates access to low qa in existing devices (via reduced collisionality & resistivity), 2) minimizes the RE avalanche by ‘purging’ the high-Z atoms from the RE beam, 3) drives recombination of the background plasma, reducing the density and Alfven time, thus accelerating the MHD growth. Furthermore, this phenomenon is found to be accessible when crossing the low qa stability boundary with rising current, falling toroidal field, or contracting minor radius - the latter being the expected scenario for vertically unstable RE beams in ITER. While unexpected, this path scales favorably to fusion-grade tokamaks and offers a novel RE mitigation scenario in principle accessible with the day-one disruption mitigation system (DMS) of ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical Optimization of Spray-Guided Spark Assistance for Cold Idle Operation in a Heavy-Duty Gasoline Compression Ignition Engine

This article describes the results of a response surface model (RSM)-based numerical optimization campaign for spray-guided spark assistance at cold operations in a heavy-duty gasoline compression ignition (GCI) engine. On the basis of an earlier work on spark-assisted GCI cold combustion, a space-filling design of experiments (DoE) method was first undertaken to investigate a multitude of hardware design variables and engine operating parameters. The main design variables included the number of injector nozzles, fuel split quantities and injection timings, and spark timing. The objective variables were engine combustion efficiency (ŋ c ), maximum pressure rise rate (MPRR), and engine-out nitrogen oxide (NO x ) emissions. A total of 150 design candidates were automatically generated using the Sobol sequence method provided by the commercial software package, CAESES. Then, closed-cycle computational fluid dynamic (CFD) spark-assisted GCI simulations under cold idling operations were performed. The outcomes from the CFD-DoE design campaign were utilized to construct high-fidelity RSMs that allowed for further design optimization of the spark plug- and fuel injector-related design variables, along with fuel injection strategy parameters. A merit function with respect to objective variables was formulated with an appropriate weight assignment on each objective variable. Finally, the best design candidate was identified from the RSM-based optimization process and further validated in the CFD analysis. The best design candidate showed the potential to significantly improve combustion efficiency (ŋ c > 90%) over the baseline at cold idle while satisfying MPRR and NOx emissions constraints (MPRR < 5 bar/CAD and NO x < 4.5 g/kWh).

33 ADVANCED PROPULSION SYSTEMS↗

A 16 x 16 element extrinsic silicon detector array

Two bismuth-doped silicon accumulation-mode charge-injection device (AMCID) infrared detector arrays are studied. The geometry and composition of the arrays, and a description of the cold and warm electronics components of the system are described. Instructions for setting up and operating the array system, plus results of a functional test, are included.

Source record↗

The Aquarius Ocean Salinity Mission High Stability L-band Radiometer

The NASA Earth Science System Pathfinder (ESSP) mission Aquarius, will measure global ocean surface salinity with approx.120 km spatial resolution every 7-days with an average monthly salinity accuracy of 0.2 psu (parts per thousand). This requires an L-band low-noise radiometer with the long-term calibration stability of less than or equal to 0.15 K over 7 days. The instrument utilizes a push-broom configuration which makes it impractical to use a traditional warm load and cold plate in front of the feedhorns. Therefore, to achieve the necessary performance Aquarius utilizes a Dicke radiometer with noise injection to perform a warm - hot calibration. The radiometer sequence between antenna, Dicke load, and noise diode has been optimized to maximize antenna observations and therefore minimize NEDT. This is possible due the ability to thermally control the radiometer electronics and front-end components to 0.1 Crms over 7 days.

Pellerano, Fernando A.↗

The Aquarius ocean salinity mission high stability L-band radiometer

The NASA Earth Science System Pathfinder (ESSP) mission Aquarius, will measure global ocean surface salinity with ~120 km spatial resolution every 7-days with an average monthly salinity accuracy of 0.2 psu (parts per thousand) [1]. This requires an L-band low-noise radiometer with the long-term calibration stability of ≤0.15 K over 7 days. The instrument utilizes a push-broom configuration which makes it impractical to use a traditional warm load and cold plate in front of the feedhorns. Therefore, to achieve the necessary performance Aquarius utilizes a Dicke radiometer with noise injection to perform a warm – hot calibration. The radiometer sequence between antenna, Dicke load, and noise diode has been optimized to maximize antenna observations and therefore minimize NEDT. This is possible due the ability to thermally control the radiometer electronics and front-end components to 0.1 °Crms over 7 days.

Freedman, Adam↗

Turnover of Biogenic Amines in the Hypothalamus of Rats during Pyrogen Fever

Many pharmacological studies have implicated the biogenic amines in the hypothalamus as playing a role in the production of fever, but few investigations of endogenous neurochemicals have been made during fever. Turnover rates of transmitters utilizing radioactive precursors may be one of the most accurate measurements of activity in brain regions. The present study was designed to measure the turnover of 5-hydroxytryptamine (5-HT) norepinephrine (NE) and dopamine (DA) in the hypothalamus of rats during pyrogen fever. Salmonella typhosa (Wyeth, 8 units) was previously found in our laboratory to produce a significant hyperthermia in most rats by 2.5 hours. This pyrogen (N = l2) or saline control (N = 8) was injected intraperitoneally and the rats killed 2.75 hours later. Rectal temperatures (Tr) were monitored continuously with thermocouples taped to the tail and recorded automatically every 3 minutes. Half of each group received an injection of radioactive precursors, (3)H-tryptophan (0.5 mCi) and (3)H-tryptophan (1.0 mCi), via an indwelling jugular catheter 60 minutes before killing, and the other half at 90 minutes. The rats were killed by near freezing in liquid nitrogen and the brains dissected in the cold. Turnover was measured by the method of Lane (Life Sci 21, 1101, 1977). At the time of killing most of the pyrogen group showed a significant (p < .02) increase (mean +/- s.e.m.) in Tr above pre injection levels (0.75 +/- 0.13 C, N = 10). The saline group showed no change (-0.025 +/- 0.16, N = 8), and the difference between groups was also significant. No significant differences were found in the levels of the amines between the pyrogen and saline groups. A significant difference was found in the specific activity of NE between the 60 minute pyrogen and saline groups (4.41 +/- 0.41 vs 2.6 +/- 0.51 dpm/pmole) but no change in turnover. This suggests an increased accumulation of (3)H-NE in the pyrogen group, but no change in utilization. An increased turnover of DA for the pyrogen group (44.5 vs 19.2 pmole/mg protein/hr) was found. However, DA is mainly a precursor in the hypothalamus and measurement was near the limit of sensitivity for the assay; these limitations Must be considered in interpreting this data. The most significant finding was an increase in the turnover of 5-HT in the pyrogen group (41.3 vs 7.3 pmole/mg protein/hr), indicating a resynthetization rate of 77% of the total pool per hour. These results suggest that at the time point measured, an increase in the utilization of 5-HT in the hypothalamus is-correlated with pyrogen fever.

Penn, P. E.↗

Measurements of Siple transmitter signals on the DE 1 satellite - Wave normal direction and antenna effective length

A new experimental technique is developed to simultaneously measure the wave propagation direction and the effective length of a small (L value much smaller than wavelength) electric dipole antenna on a spin-stabilized satellite in the magnetosphere. The technique relies on the near simultaneous measurement of single components of the electric and magnetic fields of a coherent VLF signal injected into the medium from a ground-based source. The spin fading characteristics of the signal received by the electric dipole and the magnetic loop antenna permit the measurement of the wave normal direction assuming whistler-mode propagation. In-situ and remote measurements of the local cold plasma density are used to determine the refractive index. The wave electric field is then inferred from the wave magnetic field as measured on the loop antenna, the refractive index and the direction of propagation. Comparing this electric field with the measured voltage across the dipole antenna leads to the determination of the effective length of the receiving electric dipole. The technique is applied to data from the Dynamics Explorer 1 satellite observations of whistler mode signals injected into the magnetosphere from the Siple, Antarctica, VLF transmitter. In one case, with the measured background cold plasma density being 15 el/cu cm, the effective length of the 200 m-long electric dipole antenna is found to be 222 + or - 56 m, i.e., about twice the conventional value.

Sonwalker, V. S.↗

Imaging hydrogen flames by two-photon, laser-induced fluorescence

A nonintrusive multicomponent imaging system is developed which can image hydrogen, hot oxygen, and air simultaneously. An Ar-F excimer laser is injection-locked to cover the Q1 two-photon transition in molecular hydrogen which allows the observation of both hot oxygen and cold hydrogen. Rayleigh scattering from the water molecules occurs at the same frequency as the illuminating laser allowing analysis of the air density. Images of ignited and nonignited hydrogen jets are recorded with a high-sensitivity gated video camera. The images permit the analysis of turbulent hydrogen-core jet, the combustion zone, and the surrounding air, and two-dimensional spatial correlations can be made to study the turbulent structure and couplings between different regions of the flow field. The method is of interest to the study of practical combustion systems which employ hydrogen-air diffusion flames.

Miles, R.↗

Unsteady High Turbulence Effects on Turbine Blade Film Cooling Heat Transfer Performance Using a Transient Liquid Crystal Technique

Unsteady wake effect, with and without trailing edge ejection, on detailed heat transfer coefficient and film cooling effectiveness distributions is presented for a downstream film-cooled gas turbine blade. Tests were performed on a five-blade linear cascade at an exit Reynolds number of 5.3 x 10(exp 5). Upstream unsteady wakes were simulated using a spoke-wheel type wake generator. Coolant blowing ratio was varied from 0.4 to 1.2; air and CO2 were used as coolants to simulate different density ratios. Surface heat transfer and film effectiveness distributions were obtained using a transient liquid crystal technique; coolant temperature profiles were determined with a cold wire technique. Results show that Nusselt numbers for a film cooled blade are much higher compared to a blade without film injection. Unsteady wake slightly enhances Nusselt numbers but significantly reduces film effectiveness versus no wake cases. Nusselt numbers increase only slic,htly but film cooling, effectiveness increases significantly with increasing, blowing ratio. Higher density coolant (CO2) provides higher effectiveness at higher blowing ratios (M = 1.2) whereas lower density coolant (Air) provides higher 0 effectiveness at lower blowing ratios (M = 0.8). Trailing edge ejection generally has more effect on film effectiveness than on the heat transfer, typically reducing film effectiveness and enhancing heat transfer. Similar data is also presented for a film cooled cylindrical leading edge model.

Han, J. C.↗

Formation of Tropopause Cirrus clouds by Typhoon-induced gravity waves during the Asian Summer Monsoon: A Case Study from the BATAL 2017 Campaign

Cirrus clouds in the Tropical Tropopause Layer (TTL) have a net warming impact on Earth’s climate and they regulate the amount of water vapor entering the lower stratosphere through dehydration process near the cold-point tropopause. During the Boreal summer, Asian Summer Monsoon (ASM) is an important source of cirrus clouds and humidity in the TTL owing to frequent deep convection. However, better representation of convection and TTL cirrus clouds in global climate models is needed for accurate assessment of their response to changing climate. In this study, we investigate the mechanisms involved in the formation of a tropopause cirrus cloud layer observed during the Balloon measurement campaigns of the Asian Tropopause Aerosol Layer (BATAL) over Hyderabad (17.47 °N, 78.58 °E), India on 23 August 2017. A subvisible cirrus cloud layer (optical thickness ~0.025) was detected by a backscatter sonde (COBALD) onboard a balloon near the cold-point tropopause (CPT, temperature~ -86.4 ° C, altitude~17.9 km) which was later confirmed by the CATS lidar on the ISS. Simultaneous measurements from an optical particle counter (Boulder Counter) revealed the presence of ice crystals smaller than 50 microns in this layer. The formation mechanism responsible for this tropopause cirrus is investigated using a technique combining three-dimensional back-trajectories, satellite observations, and ERA5 reanalysis data. Satellite observations revealed that the overshooting convection associated with a category-3 typhoon Hato, which hit Macau and Hong Kong on 23 August 2017 injected ice into the lower stratosphere. This caused a hydration patch that followed the ASM anticyclone subsequently moving towards Hyderabad. The presence of tropopause cirrus cloud layers in the cold temperature anomalies and updrafts along the back-trajectories indicated towards the role of typhoon-induced gravity waves in their formation. This case study highlights the role of typhoons in influencing the formation of tropopause cirrus clouds through stratospheric hydration and gravity waves in the ASM anticyclone.

Amit Kumar Pandit↗

Multiple jet study

Test data is presented which allows determination of jet penetration and mixing of multiple cold air jets into a ducted subsonic heated mainstream flow. Jet-to-mainstream momentum flux ratios ranged from 6 to 60. Temperature profile data is presented at various duct locations up to 24 orifice diameters downstream of the plane of jet injection. Except for two configurations, all geometries investigated had a single row of constant diameter orifices located transverse to the main flow direction. Orifice size and spacing between orifices were varied. Both of these were found to have a significant effect on jet penetration and mixing. The best mixing of the hot and cold streams was achieved with duct height.

Walker, R. E.↗

Variable frequency VLF signals in the magnetosphere Associated phenomena and plasma diagnostics

Coherent variable-frequency signals (ramps) extending from 1 to 8 kHz, injected into the magnetosphere from Siple Station, Antarctica (L=4.3), exhibit upper and lower cutoffs when received at the conjugate station, Roberval, Quebec. Ramp group delay measurements and ionospheric sounding data are used to determine the cold plasma density and L shell of the propagation path. Relationships among f, df/dt, and the 'phase equator' for gyroresonance are calculated using second-order resonance equations generalized to relativistic electrons. The concept thereby introduced is used to develop a diagnostic technique which, for an assumed g(alpha)(v exp -n) electron distribution, provides an estimate of the energy dependence n. Additional aspects of the magnetospheric response to ramp injection, such as emission triggering, curvature due to dispersion, and amplitude saturation, are discussed.

Carlson, C. R.↗

Cold water aquifer storage

A working prototype system is described in which water is pumped from an aquifer at 70 F in the winter time, chilled to a temperature of less than 50 F, injected into a ground-water aquifer, stored for a period of several months, pumped back to the surface in the summer time. A total of 8.1 million gallons of chilled water at an average temperature of 48 F were injected. This was followed by a storage period of 100 days. The recovery cycle was completed a year later with a total of 8.1 million gallons recovered. Approximately 20 percent of the chill energy was recovered.

Reddell, D. L.↗

A Finite Element Method for Compressible and Turbulent Multiphase Flow Instabilities with Heat Transfer

We present a new finite element framework for modeling compressible, turbulent multiphase flows with heat transfer. For two-fluid systems with a free surface, the Volume of Fluid (VOF) method is implemented without the need for interface reconstruction, while turbulence is resolved using a dynamic Vreman large eddy simulation (LES) model. Unlike most two-phase VOF studies, which neglect heat transfer, the present approach incorporates energy transport equations within the VOF formulation to account for heat exchange, an effect particularly important in turbulent flows. Conjugate heat transfer is often challenging in finite volume methods, which require explicit specification of heat fluxes at the solid–fluid interface, limiting accuracy and predictive capability. By contrast, the finite element formulation does not require heat flux inputs, allowing more accurate and robust simulation of heat transfer between solids and fluids. The method is demonstrated through three representative cases. First, a two-fluid instability with a single-mode perturbation is simulated and validated against analytical growth rates. Second, conjugate heat transfer is examined in a high-temperature flow over a cold metal cylinder, with validation performed both quantitatively—via pressure coefficient comparisons with experimental data—and qualitatively using vector field topology. Finally, compressible spray injection and breakup are modeled, demonstrating the ability of the framework to capture interfacial dynamics and atomization under turbulent, high-speed conditions. In the compressible spray injection and breakup case, the results indicate that the finite element formulation achieved higher predictive accuracy and robustness than the finite-volume method. With the same mesh resolution, the FEM reduced the root mean square error (RMSE) and mean absolute percentage error (MAPE) from 6.96 mm and 26.0% (for the FVM) to 4.85 mm and 12.7%, respectively, demonstrating improved accuracy and robustness in capturing interfacial dynamics and heat transfer. The study also introduced vector field topology to visualize and interpret coherent flow structures and instabilities, offering insights beyond conventional scalar-field analyses.

97 MATHEMATICS AND COMPUTING↗

Hypersonic engine airplane integration

A summary of the research activities is presented along with the design and analysis of an integrated scramjet engine which utilizes heat conduction flames. The scramjet engine model described was tested at a freestream Mach number of 4.0 by personnel at the General Applied Science Laboratory. The research effort was primarily concerned with the interpretation and analysis of the experimental data. The mixing tests were conducted with cold ambient air, while the combustion tests were conducted with hot vitiated air. The purpose of the cold mixing tests was to determine the degree of mixedness of the fuel at the ignitor station so as to certify if the fuel injection conditions and fuel injectors locations were properly selected to give a uniform fuel concentration profile at the ignitor station. A second objective was to assess the influence of the fuel injection on the inlet flow. Several fuel injection configurations were tested.

Source record↗

Beam-induced pressure gradients in the early phase of proton-heated solar flares

The pressure gradient induced in a coronal loop by proton beam momentum deposition is calculated and compared with the thermal pressure gradient arising from nonuniform deposition of beam energy; it is assumed that the transfer of momentum and energy from beam to target occurs via the Coulomb interaciton. Results are presented for both a low mean energy and a high mean energy proton beam injected at the loop apex and characterized by a power-law energy spectrum. The present treatment takes account of the breakdown of the cold target approximation for the low-energy proton beam in the corona, where the thermal speed of target electrons exceeds the beam speed. It is found that proton beam momentum deposition plays a potentially significant role in flare dynamics only in the low mean energy case and only in the corona, where it may dominate the acceleration of target material for as long as several tens of seconds. This conclusion suggest that the presence of low-energy nonthermal protons may be inferred from velocity-sensitive coronal observations in the early impulsive phase.

Tamres, David H.↗

Modeling the Rapid Boil-Off of a Cryogenic Liquid When Injected into a Low Pressure Cavity

Many launch vehicle cryogenic applications require the modeling of injecting a cryogenic liquid into a low pressure cavity. The difficulty of such analyses lies in accurately predicting the heat transfer coefficient between the cold liquid and a warm wall in a low pressure environment. The heat transfer coefficient and the behavior of the liquid is highly dependent on the mass flow rate into the cavity, the cavity wall temperature and the cavity volume. Testing was performed to correlate the modeling performed using Thermal Desktop and Sinda Fluint Thermal and Fluids Analysis Software. This presentation shall describe a methodology to model the cryogenic process using Sinda Fluint, a description of the cryogenic test set up, a description of the test procedure and how the model was correlated to match the test results.

Fluid Mechanics↗