Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coagulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Pure Ethiodized Oil-based Transcatheter Ablative Therapy in Normal Rabbit Kidneys and Kidneys Inoculated with VX-2 Carcinoma

Purpose: To evaluate the efficacy of ablation with selective arterial injection of pure ethiodized oil followed by arterial occlusion with 9:1 ethanol-Ethiodol mixture (EEM) and coil placement in normal rabbit kidneys and kidneys inoculated with VX-2 carcinoma. Materials and Methods: All experiments were conducted with Animal Care and Use Committee approval. In six rabbits (group 1), one kidney was embolized with pure Ethiodol until capillary stasis, followed by injection of 9:1 EEM until arterial stasis and then coil placement into the main renal artery. In 12 other rabbits, one kidney was inoculated with VX-2 tumor. Ethiodol and EEM embolization and coil placement followed 7 days later (group 2, n = 6) or 11-14 days later (group 3, n = 6). Kidneys were evaluated (angiography, computed tomography, macro- and microscopy) 7 days after treatment. Results: Capillary stasis was achieved in groups 1, 2, and 3 with (mean {+-} standard deviation) 0.47 {+-} 0.03, 0.53 {+-} 0.02, and 0.56 {+-} 0.04 ml of pure Ethiodol, followed by 0.47 {+-} 0.05, 0.42 {+-} 0.03, and 0.38 {+-} 0.04 ml of EEM, respectively, which caused complete arterial occlusion in 17 of 18 kidneys. In group 1, all but one kidney showed at least 95% generalized coagulative necrosis. In group 2, all six kidneys exhibited 100% coagulative necrosis, with no viable tumor present. In group 3, 100% coagulative necrosis was present in all kidneys, with a small viable tumor in one. Conclusion: In the rabbit, selective arterial injection of pure Ethiodol can cause complete renal parenchyma and tumor ablation when it is followed by prompt, contiguous, and permanent occlusion of the arterial compartment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiological Insertion of Denver Peritoneovenous Shunts for Malignant Refractory Ascites: A Retrospective Multicenter Study (JIVROSG-0809)

Purpose: Peritoneal venous shunts (PVSs) are widely used for palliating symptoms of refractory malignant ascites and are recognized as one of the practical methods. However, reliable clinical data are insufficient because most previous reports have been small studies from single centers. We conducted a retrospective, multicenter study to evaluate the safety and efficacy of radiologically placed PVSs in patients with malignant refractory ascites. Methods: A total of 133 patients with malignant ascites refractory to medical therapies were evaluated for patient characteristics, technical success, efficacy, survival times, adverse events, and changes in laboratory data. Results: PVSs were successfully placed in all patients and were effective (i.e., improvement of ascites symptoms lasting 7 days or more) in 110 (82.7%). The median duration of symptom palliation was 26 days and median survival time was 41 days. The most frequent adverse event was PVS dysfunction, which occurred in 60 (45.1%) patients, among whom function was recovered with an additional minimally invasive procedure in 9. Abnormalities in coagulation (subclinical disseminated intravascular coagulation) occurred in 37 (27.8%) patients, although only 7 (5.3%) developed clinical disseminated intravascular coagulation. Other major adverse events were gastrointestinal bleeding (9.8%), sepsis (3.8%), and acute heart failure (3.0%). PVS was least effective in patients with elevated serum creatinine, bloody ascites, or gynecologic tumor. Conclusions: Radiological PVS is a technically feasible and effective method for palliating the symptoms from refractory malignant ascites, but preoperative evaluation and monitoring the postprocedural complications are mandatory to preclude severe adverse events after PVS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct Current Combined With Bipolar Radiofrequency Ablation: An Ex Vivo Feasibility Study

The combination of radiofrequency ablation (RFA) with direct current (DC) is a promising strategy to improve the efficiency of RFA. However, DC-enhanced monopolar RFA is limited by electrolytic injury at the positive-electrode site. The aim of this study was to investigate the feasibility of the DC-enhanced bipolar RFA. To obviate the need for the subcutaneous positive electrode, the DC circuit was combined with a commercially available bipolar RFA system, in which both poles of the DC circuit are connected to a single RF probe. DC was applied for 15 min and followed by RFA in bovine livers using the following various DC currents: (1) no DC (control), (2) 3V continued until the end of RFA, (3) 5V continued until the end of RFA, (4) 10V continued until the end of RFA, (5) 5V continued in the circuit with reversed pole, (6) 3V stopped after initiation of RFA, and (7) 5V stopped. Coagulation volume, temperatures at a distance of 5, 10, and 15 mm from the RF probe, mean amperage, ablation duration, applied energy, minimum impedance, and degree of tissue charring were assessed and compared (analysis of variance, Student-Newman-Keuls test). All combined DC and RFA groups did increase coagulation volume. The 10V continued group showed significantly lower applied energy, shortest ablation duration, highest minimum impedance, and highest degree of charring with the lowest coagulation volume (p < 0.05). DC-enhanced bipolar RFA with both poles of the DC circuit on a single probe appears to be ineffective.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined Treatment of Large Hepatocellular Carcinoma with Transcatheter Arterial Chemoembolization and Percutaneous Ethanol Injection with a Multipronged Needle: Experimental and Clinical Investigation

Purpose: This study was designed to evaluate the usefulness of percutaneous ethanol injection (PEI) with a multipronged needle for the treatment of large hepatocellular carcinoma (HCC). An experimental animal study and a clinical investigation were performed. Methods: In the experimental study, 20 ml of 99.5% ethanol was injected into porcine liver in vivo with a multipronged needle (n = 5) or a straight needle (n = 5), and the volumes of coagulation necrosis were compared. In the clinical investigation, PEI was performed in 17 patients (10 men, 7 women; mean age 73.4 {+-} 6.7 years) with single, large HCC (mean tumor diameter, 47.2 {+-} 11.5 mm; range, 32-70 mm) by using a multipronged needle. Fifteen of 17 patients received transarterial chemoembolization (TACE) before PEI. Results: The volume of coagulation in porcine liver in vivo was significantly increased with the multipronged needle compared with the straight needle (longest perpendicular diameters, 34.2 {+-} 3.6 mm Multiplication-Sign 30.2 {+-} 3.6 mm vs. 22.6 {+-} 2.5 mm Multiplication-Sign 19 {+-} 2.2 mm, respectively; P < 0.05). In the clinical trial, initial complete response (CR) of the tumor was achieved in 17 of 17 patients, 7 of whom required two PEI sessions. During the follow-up, local recurrence was detected in 4 of 17 patients at 3-19 months after the procedure, for a rate of sustained local CR of 76%. No major complication occurred. Conclusions: Use of a multipronged needle substantially increases the volume of coagulation in vivo with respect to the conventional PEI technique. Combined TACE and PEI with multipronged needles is a safe and effective option for percutaneous treatment of single, large HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Peripherally Inserted Central Catheter-Related Infections in a Cohort of Hospitalized Adult Patients

PurposeTo determine the incidence and the risks factors of peripherally inserted central catheter (PICC)-related infectious complications.Materials and MethodsMedical charts of every in-patient that underwent a PICC insertion in our hospital between January 2010 and October 2013 were reviewed. All PICC-related infections were recorded and categorized as catheter-related bloodstream infections (CR-BSI), exit-site infections, and septic thrombophlebitis.ResultsNine hundred and twenty-three PICCs were placed in 644 unique patients, mostly male (68.3 %) with a median age of 58 years. 31 (3.4 %) PICC-related infections occurred during the study period corresponding to an infection rate of 1.64 per 1000 catheter-days. We observed 27 (87.1 %) CR-BSI, corresponding to a rate of 1.43 per 1000 catheter-days, 3 (9.7 %) septic thrombophlebitis, and 1 (3.2 %) exit-site infection. Multivariate logistic regression analysis showed a higher PICC-related infection rate with chemotherapy (odds ratio (OR) 7.2–confidence interval (CI) 95 % [1.77–29.5]), auto/allograft (OR 5.9–CI 95 % [1.2–29.2]), and anti-coagulant therapy (OR 2.2–95 % [1.4–12]).ConclusionChemotherapy, auto/allograft, and anti-coagulant therapy are associated with an increased risk of developing PICC-related infections.Clinical AdvanceChemotherapy, auto/allograft, and anti-coagulant therapy are important predictors of PICC-associated infections. A careful assessment of these risk factors may be important for future success in preventing PICC-related infections.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of carboxymethyl chitosan on the blood system of rats

Highlights: {yields} We report, for the first time, the safety of carboxymethyl chitosan in blood system. {yields} CM-Chitosan has no significant effects on coagulation function of rats. {yields} CM-Chitosan has no significant effects on anticoagulation performance of rats. {yields} CM-Chitosan has no significant effects on fibrinolytic function of rats. {yields} CM-Chitosan has no significant effects on hemorheology of rats. -- Abstract: Carboxymethyl chitosan (CM-chitosan), a derivative of chitosan, was extensively studied in the biomedical materials field for its beneficial biological properties of hemostasis and stimulation of healing. However, studies examining the safety of CM-chitosan in the blood system are lacking. In this study CM-chitosan was implanted into the abdominal cavity of rats to determine blood indexes at different times and to evaluate the effects of CM-chitosan on the blood system of rats. Coagulation function was reflected by thrombin time (TT), prothrombin time (PT), activated partial thromboplatin time (APTT), fibrinogen (FIB) and platelet factor 4 (PF4) indexes; anti-coagulation performance was assessed by the index of antithrombinIII (ATIII); fibrinolytic function was reflected by plasminogen (PLG) and fibrin degradation product (FDP) indexes; and blood viscosity (BV) and plasma viscosity (PV) indexes reflected hemorheology. Results showed that CM-chitosan has no significant effects on the blood system of rats, and provides experimental basis for CM-chitosan to be applied in the field of biomedical materials.

60 APPLIED LIFE SCIENCES↗

Rac1 regulates sepsis-induced formation of platelet-derived microparticles and thrombin generation

Dysfunctional coagulation aggravates clinical outcome in patients with sepsis. The aim of this study was to define the role of Rac-1 in the formation of platelet-derived microparticles (PMPs) and thrombin generation (TG) in abdominal sepsis. Male C57BL/6 mice underwent cecal ligation and puncture (CLP). Scanning electron microscopy and flow cytometry were used to quantify PMPs. TG was determined by use of a fluorimetric assay. It was found that CLP increased Rac1 activity in platelets, which was abolished by administration of the Rac1 inhibitor NSC23766. Sepsis-induced TG in vivo was reflected by reduced capacity of plasma from septic animals to generate thrombin ex vivo. Administration of NSC23766 increased peak and total TG in plasma from CLP mice indicating that Rac-1 regulates sepsis-induced formation of thrombin. The number of circulating PMPs was markedly elevated in animals with abdominal sepsis. Treatment with NSC23766 significantly decreased formation of PMPs in septic mice. Platelet activation in vitro caused release of numerous MPs. Notably, NSC23766 abolished PMP formation in activated platelets in vitro. These findings suggest that Rac-1 regulates PMP formation and TG in sepsis and that inhibition of Rac1 activity could be a useful target to inhibit dysfunctional coagulation in abdominal sepsis. - Highlights: • Rac-1 regulates platelet-derived microparticles formation in abdominal sepsis. • Rac-1 mediates formation of thrombin generation in abdominal sepsis. • Targeting Rac-1 activity might protect against coagulation dysfunction in sepsis.

60 APPLIED LIFE SCIENCES↗

A model of particulate and species formation applied to laminar, nonpremixed flames for three aliphatic-hydrocarbon fuels

A detailed kinetic mechanism is developed that includes aromatic growth and particulate formation. The model includes reaction pathways leading to the formation of nanosized particles and their coagulation and growth to larger soot particles using a sectional approach for the particle phase. It is tested against literature data of species concentrations and particulate measurements in nonpremixed laminar flames of methane, ethylene, and butene. Reasonably good predictions of gas and particle-phase concentrations and particle sizes are obtained without any change to the kinetic scheme for the different fuels. The model predicts the low concentration of particulates in the methane flame (about 0.5 ppm) and the higher concentration of soot in the ethylene and butene flames (near 10 ppm). Model predictions show that in the methane flame small precursor particles dominate the particulate loading, whereas soot is the major component in ethylene and butene flames, in accordance with the experimental data. The driving factors in the model responsible for the quite different soot predictions in the ethylene and butene flames compared with the methane flame are benzene and acetylene concentrations, which are higher in the ethylene and butene flames. Soot loadings in the ethylene flame are sensitive to the acetylene soot growth reaction, whereas particle inception rates are linked to benzene in the model. A coagulation model is used to obtain collision efficiencies for some of the particle reactions, and tests show that the modeled results are not particularly sensitive to coagulation at the rates used in our model. Soot oxidation rates are not high enough to correctly predict burnout, and this aspect of the model needs further attention. (author)

03 NATURAL GAS↗

Quantifying structural errors in cloud condensation nuclei activity from reduced representation of aerosol size distributions

Aerosol effects on clouds and radiation are the dominant contribution to uncertainty in radiative forcing relative to the pre-industrial atmosphere. While previous studies have assessed the impact of parametric uncertainty on modeled forcing, structural errors from the numerical representation of particle distributions have not been well quantified. Here we present a framework for quantifying error in aerosol size distributions and cloud condensation nuclei activity, which we apply to the widely used 4-mode version of the Modal Aerosol Module (MAM4). Box model predictions from the MAM4 are evaluated against the Particle Monte Carlo Model for Simulating Aerosol Interactions and Chemistry (PartMC-MOSAIC), a benchmark model that tracks the evolution of individual particles. We show that size distributions simulated by MAM4 diverge from those simulated by PartMC-MOSAIC after only a few hours of aging by condensation and coagulation in polluted conditions, which leads to large errors in modeled cloud condensation nuclei concentrations. We find that differences between MAM4 and PartMC-MOSAIC are largest under polluted conditions, where the size distribution evolves rapidly though aging by condensation of semi-volatile substances and coagulation among particles. These findings suggest that structural error in modeled aerosol properties contributes to the large inter-model variability in aerosol radiative forcing.

Fierce, Laura M.↗

Stochastic weighted particle methods for population balance equations

Highlights: {yields} Weight transfer functions for Monte Carlo simulation of coagulation. {yields} Efficient support for single-particle growth processes. {yields} Comparisons to analytic solutions and soot formation problems. {yields} Better numerical accuracy for less common particles. - Abstract: A class of coagulation weight transfer functions is constructed, each member of which leads to a stochastic particle algorithm for the numerical treatment of population balance equations. These algorithms are based on systems of weighted computational particles and the weight transfer functions are constructed such that the number of computational particles does not change during coagulation events. The algorithms also facilitate the simulation of physical processes that change single particles, such as growth, or other surface reactions. Four members of the algorithm family have been numerically validated by comparison to analytic solutions to simple problems. Numerical experiments have been performed for complex laminar premixed flame systems in which members of the class of stochastic weighted particle methods were compared to each other and to a direct simulation algorithm. Two of the weighted algorithms have been shown to offer performance advantages over the direct simulation algorithm in situations where interest is focused on the larger particles in a system. The extent of this advantage depends on the particular system and on the quantities of interest.

97 MATHEMATICS AND COMPUTING↗

Facile preparation of carbon coated magnetic Fe{sub 3}O{sub 4} particles by a combined reduction/CVD process

Graphical abstract: Magnetic carbon coated Fe{sub 3}O{sub 4} particles are prepared by a one step combined reduction of Fe{sub 2}O{sub 3} together with a CVD process of using methane. Analyses show that the Fe{sub 2}O{sub 3} is reduced by methane to produce mainly Fe{sub 3}O{sub 4} particles coated with amorphous carbon. These materials can be separated into two fractions by simple dispersion in water and can be used as adsorbents, catalyst supports and rapid coagulation systems. Research highlights: {yields} Magnetic Fe{sub 3}O{sub 4} particles coated with a very thin layer of amorphous carbon (4 wt%). {yields} Combined reduction of Fe{sub 2}O{sub 3} with a Chemical Vapor Deposition process using methane. {yields} Nanoparticles with an average size of 100-200 nm. {yields} Uses as adsorbent, catalyst support and rapid coagulation systems. -- Abstract: In this work, we report a simple method for the preparation of magnetic carbon coated Fe{sub 3}O{sub 4} particles by a single step combined reduction of Fe{sub 2}O{sub 3} together with a Chemical Vapor Deposition process using methane. The temperature programmed reaction monitored by Moessbauer, X-ray Diffraction and Raman analyses showed that Fe{sub 2}O{sub 3} is directly reduced by methane at temperatures between 600 and 900 {sup o}C to produce mainly Fe{sub 3}O{sub 4} particles coated with up to 4 wt% of amorphous carbon. These magnetic materials can be separated into two fractions by simple dispersion in water, i.e., a settled material composed of large magnetic particles and a suspended material composed of nanoparticles with an average size of 100-200 nm as revealed by Scanning Electron Microscopy and High-resolution Transmission Electron Microscopy. Different uses for these materials, e.g., adsorbents, catalyst supports, rapid coagulation systems, are proposed.

36 MATERIALS SCIENCE↗

Tissue factor contributes to neutrophil CD11b expression in alpha-naphthylisothiocyanate-treated mice

Cholestatic liver injury induced by alpha-naphthylisothiocyanate (ANIT) is provoked by injury to intrahepatic bile ducts and the progression of hepatic necrosis requires the procoagulant protein tissue factor (TF) and extrahepatic cells including neutrophils. Recent studies have shown that myeloid cell TF contributes to neutrophil activation. We tested the hypothesis that myeloid cell TF contributes to neutrophil activation in ANIT-treated mice. TF activity in liver homogenates increased significantly in TF{sup flox/flox} mice treated with ANIT, but not in TF{sup flox/flox}/LysMCre mice (TF{sup {Delta}Myeloid} mice), which have reduced TF expression in monocytes/macrophages and neutrophils. Myeloid cell-specific TF deficiency did not alter expression of the chemokines KC or MIP-2 but reduced hepatic neutrophil accumulation in ANIT-treated mice at 48 h as indicated by tissue myeloperoxidase (MPO) activity. Myeloid cell TF deficiency significantly reduced CD11b expression by blood neutrophils in ANIT-treated mice, and this was associated with reduced plasma MPO protein levels, an index of neutrophil degranulation. However, myeloid cell-specific TF deficiency had no effect on ANIT-induced coagulation cascade activation. The increase in serum ALT and ALP activities in ANIT-treated mice was reduced by myeloid cell TF deficiency (p < 0.05), but the myeloid cell TF deficiency did not reduce hepatic necrosis at 48 h, as determined by histopathology and morphometry. The results suggest that myeloid cell TF contributes to neutrophil CD11b expression during cholestasis by a coagulation-independent pathway. However, the resultant reduction in neutrophil accumulation/activation is insufficient to substantially reduce ANIT hepatotoxicity, suggesting that myeloid cell TF is only one of many factors modulating hepatic necrosis during cholestasis. - Research Highlights: > Myeloid cell tissue factor contributes to liver procoagulant activity during acute cholestasis. > ANIT-induced coagulation cascade activation is independent of myeloid cell tissue factor. > Myeloid cell tissue factor contributes to neutrophil CD11b priming during cholestasis.

60 APPLIED LIFE SCIENCES↗

Lepidocrocite Titanate–Graphene Composites for Sodium-Ion Batteries

To overcome electronic transport issues of layered titanates in sodium-ion batteries, we have designed and synthesized composites of lepidocrocite titanates with reduced graphene oxide through a solution-based self-assembly approach. The parent lepidocrocite titanate (K 0.8 [Ti 1.73 Li 0.27 ]O 4 ) was exfoliated by a soft-chemical approach and mechanical shaking. Exfoliated layered titania sheets (LTO) were then combined with reduced graphene oxide (rGO) layers to assemble into composites through flocculation. Countercations (i.e., Mg 2+ ) were used for the self-assembly of negatively charged titania and rGO nanosheets via flocculation. The carbon content in the composites was tuned from 1 to 17% by changing the ratio of titania and rGO sheets in the mixed colloidal suspensions. Electrodes were processed with as-prepared LTO-rGO composites without any carbon additives and tested in sodium half-cell configurations. Mg + -coagulated LTO-rGO composite electrodes deliver higher capacities than electrodes prepared with coagulated titania sheets and 10% acetylene black in sodium half-cells and display good capacity retention after 50 cycles. Electrochemical impedance spectroscopy results indicate lower charge transfer resistance for LTO-14.5%rGO composites than that of coagulated titania sheets with 10% acetylene black. A power law analysis of cells containing the composites indicate a hybrid mechanism consisting of both surface and diffusional processes. A comparison with a similar system, that of dopamine-derived LTO-C heterostructures, reveal significant differences. While capacities showed a strong dependence on carbon content for the dopamine-derived materials, this was not true for the LTO-rGO composites. Instead, the highest capacity was obtained for the 14.5% rGO sample, with a lower value obtained for the 17% rGO sample. A greater proportion of the redox processes were surface rather than diffusional in nature for the LTO-rGO composites as well.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Particle-resolved simulation of aerosol size, composition, mixing state, and the associated optical and cloud condensation nuclei activation properties in an evolving urban plume

The recently developed particle-resolved aerosol box model PartMC-MOSAIC was used to simulate the evolution of aerosol mixing state and the associated optical and cloud condensation nuclei (CCN) activation properties in an idealized urban plume. The model explicitly resolved the size and composition of individual particles from a number of sources and tracked their evolution due to condensation/evaporation, coagulation, emission, and dilution. The ensemble black carbon (BC) specific absorption cross section increased by 40% over the course of two days as a result of BC aging by condensation and coagulation. Three- and four-fold enhancements in CCN/CN ratios were predicted to occur within 6 hours for 0.2% and 0.5% supersaturations (S), respectively. The particle-resolved results were used to evaluate the errors in the optical and CCN activation properties that would be predicted by a conventional sectional framework that assumes monodisperse, internally-mixed particles within each bin. This assumption artificially increased the ensemble BC specific absorption by 14-30% and decreased the single scattering albedo by 0.03-0.07 while the bin resolution had a negligible effect. In contrast, the errors in CCN/CN ratios were sensitive to the bin resolution, and they depended on the chosen supersaturation. For S = 0.2%, the CCN/CN ratio predicted using 100 internally-mixed bins was up to 25% higher than the particle-resolved results, while it was up to 125% higher using 10 internally-mixed bins. Errors introduced in the predicted optical and CCN properties by neglecting coagulation were also quantified.

54 ENVIRONMENTAL SCIENCES↗

Correlation between nanoparticle and plasma parameters with particle growth in dusty plasmas

Since plasma parameters are altered by dust particles, studying how plasma parameters are related to dust particle growth is an important research issue in dusty plasma. In this paper, the correlation between plasma parameters (electron temperature and ion flux) and particle parameters (particle radius and density) is investigated in silane plasma both experimentally using a floating probe and theoretically by solving balance equations including an additional electron and ion loss to the dust. The results reveal that while the ion flux shows two peak values in the early discharge phase and at the end of coagulation phase, the electron temperature shows a sudden increase in the coagulation step and a gradual decrease in the molecular accretion step. Moreover, the calculated results with the secondary electron emission taken into account produce the best fit with the experimental results. Thus the study confirms that the secondary electron emission plays a crucial role in the coagulation of the dust particles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase-shift effects on growth and transport of dust particles in VHF capacitively coupled silane discharges: Two dimensional fluid simulation

A two-dimensional (2D) self-consistent fluid model is developed to describe the formation, subsequent growth, transport, and charging mechanisms of nanoparticles in a capacitively coupled silane discharge applied by two very high frequency (VHF) sources with phase shift. In this discharge process, large anions are produced by a series of chemical reactions of anions with silane molecules, while the lower limit of the initial nanoparticles are taken as large anions (Si{sub 12}H{sub 25}{sup -} and Si{sub 12}H{sub 24}{sup -}) to directly link the coagulation module with the nucleation module. And then, by using the coagulation module, the particle number density quickly decreases over several orders of magnitude, whereas the particle size strongly increases. We investigate in particular the growth of the nanoparticles ranging in size from {approx}1 to 50 nm in coagulation processes. The influences of controlled phase shifts between VHF (50 MHz) voltages on the electron density, electron temperature, nanoparticle uniformity, and deposition rate, are carefully studied. It is found from our simulation that the plasma density and nanoparticle density become center high and more uniform as the phase shift increases from 0 to 180 deg. Moreover, the role of phase-shift control in the silane discharge diluted with hydrogen gas is also discussed.

36 MATERIALS SCIENCE↗

Characterization of a dimer preparation method for nanoscale organic aerosol

Nanoscale dimers have application in studies of aerosol physicochemical properties such as aerosol viscosity. These particle dimers can be synthesized using the dual tandem differential mobility analyzer (DTDMA) technique, wherein oppositely charged particle streams coagulate to form dimers that can be isolated using electrostatic filtration. Although some characterization of the technique has been published, a detailed thesis on the modes and theory of operation has remained outside the scope of prior work. In this paper we present new experimental data characterizing the output DTDMA size distribution and the physical processes underlying its apparent modes. Key experimental limitations for both general applications and for viscosity measurements are identified and quantified in six distinct types of DTDMA experiments. The primary consideration is the production of an adequate number of dimers, which typically requires high mobility-selected number concentration in the range 25,000-100,000 cm -3 . The requisite concentration threshold depends upon the rate of spontaneous monomer decharging, which arises predominately from interactions of the aerosol with ionizing radiation within the coagulation chamber and is instrument location dependent. Lead shielding of the coagulation chamber reduced the first-order decharging constant from ~2.0 x 10 -5 s -1 to ~0.8 x 10 -5 s -1 in our laboratory. Dimer production at monomer diameters less than 40 nm is hindered by low bipolar charging efficiency. Results from the characterization experiments shed light on design considerations for general applications and for characterization of viscous aerosol phase transitions.

54 ENVIRONMENTAL SCIENCES↗

COSMIC DUST AGGREGATION WITH STOCHASTIC CHARGING

The coagulation of cosmic dust grains is a fundamental process which takes place in astrophysical environments, such as presolar nebulae and circumstellar and protoplanetary disks. Cosmic dust grains can become charged through interaction with their plasma environment or other processes, and the resultant electrostatic force between dust grains can strongly affect their coagulation rate. Since ions and electrons are collected on the surface of the dust grain at random time intervals, the electrical charge of a dust grain experiences stochastic fluctuations. In this study, a set of stochastic differential equations is developed to model these fluctuations over the surface of an irregularly shaped aggregate. Then, employing the data produced, the influence of the charge fluctuations on the coagulation process and the physical characteristics of the aggregates formed is examined. It is shown that dust with small charges (due to the small size of the dust grains or a tenuous plasma environment) is affected most strongly.

79 ASTRONOMY AND ASTROPHYSICS↗