Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “city evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Urban Effect on Precipitation and Deep Convective Systems Over Dallas‐Fort Worth

A range of multi-year observational data sets are used to characterize the hydroclimate of the Dallas Fort-Worth area (DFW) and to investigate the impact of urban land cover on daily accumulated precipitation, RADAR composite reflectivity (cREF), and cloud top height (CTH) during the warm season. Analyses of observational data indicate rainfall rates (RR) in a 45° annulus sector 50–100 km downwind of the city are enhanced relative to an upwind area of comparable size. Enhancement of mean precipitation intensity in this annulus sector is not observed on days with spatially averaged RR > 6 mm/day. Under some flow directions, the probability of cREF >30 dBZ, occurrence of hail, and the probability of CTH >10,000 geopotential meters are also enhanced up to 200 km downwind of DFW. Two deep convection events that passed over DFW are simulated with the Weather Research and Forecasting model using a range of microphysical schemes and evaluated using RADAR observations. Model configurations that exhibit the highest fidelity in these control simulations are used in a series of perturbation experiments where the areal extent of the city is varied between zero (replacement with grassland) and eight times its current size. These perturbation experiments indicate a non-linear response of Mesoscale Convective System properties to the urban areal extent and a very strong sensitivity to the microphysical scheme used. The impact on precipitation from the urban area, even when it is expanded to eight-times the current extent, is much less marked for deep convection with stronger synoptic forcing.

58 GEOSCIENCES↗

Formulation, Implementation and Validation of a 1D Boundary Layer Inflow Scheme for the QUIC Modeling System

Recent studies have highlighted the importance of accurate meteorological conditions for urban transport and dispersion calculations. In this work, we present a novel scheme to compute the meteorological input in the Quick Urban & Industrial Complex () diagnostic urban wind solver to improve the characterization of upstream wind veer and shear in the Atmospheric Boundary Layer (ABL). The new formulation is based on a coupled set of Ordinary Differential Equations (ODEs) derived from the Reynolds Averaged Navier–Stokes (RANS) equations, and is fast to compute. Building upon recent progress in modeling the idealized ABL, we include effects from surface roughness, turbulent stress, Coriolis force, buoyancy and baroclinicity. We verify the performance of the new scheme with canonical Large Eddy Simulation (LES) tests with the GPU-accelerated FastEddy"Equation missing" solver in neutral, stable, unstable and baroclinic conditions with different surface roughness. Furthermore, we evaluate QUIC calculations with and without the new inflow scheme with real data from the Urban Threat Dispersion (UTD) field experiment, which includes Lidar-based wind measurements as well as concentration observations from multiple outdoor releases of a non-reactive tracer in downtown New York City. Compared to previous inflow capabilities that were limited to a constant wind direction with height, we show that the new scheme can model wind veer in the ABL and enhance the prediction of the surface cross-isobaric angle, improving evaluation statistics of simulated concentrations paired in time and space with UTD measurements.

54 ENVIRONMENTAL SCIENCES↗

Building Tune-Up Accelerator Program (Final Technical Report)

In 2016, the City of Seattle passed a mandatory Building Tune-Up requirement for all commercial buildings 50,000 square feet (SF) and larger as part of its Climate Action strategy. The requirement is phased in by size with large buildings (greater than 200,000 SF) required first. This allowed Seattle’s Office of Sustainability & Environment (OSE) to offer the Building Tune-Up Accelerator (TUA) Program to the “mid-size” building market (less than 100,000 SF) to meet the requirements early. With funding from the US DOE, a package of technical and financial support was developed for building owners and energy service providers to encourage this hard-to-reach market to participate in the tune-up—and even go beyond requirements for greater energy savings. Seattle City Light, the municipal electric utility, offered participants a simple per square foot financial incentive. Partners at the University of Washington Integrated Design Lab, Smart Buildings Center and Pacific Northwest National Lab (PNNL) offered service provider trainings, analytical tools and technical support. This final technical report summarizes the program, projected energy and emissions savings and lessons learned from program development to implementation to final evaluation for the 102 buildings that participated.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Building a Real-Time Predictive Flood Model for Improving Early Warning Systems in Ellicott City, Maryland

As flood events in the United States grow in frequency and intensity, the use of applied remote sensing analyses is increasingly necessary for effective flood monitoring and warning systems. The NASA DEVELOP National Program partnered with the Howard County government in Maryland to investigate the use of machine learning for advanced flood risk detection, and to test the feasibility of integrating this approach into the county’s flood early warning system. To strengthen the efforts of the Howard County Office of Emergency Management (OEM), the project developed a prediction model capable of hindcasting the two severe flash flood events that devastated Ellicott City, and transitioned to an Long Short-Term Memory (LSTM) based sequence-to-sequence deep learning model with 8-hour forecast capability. The team combined data inputs from public sources including river and precipitation gauges, NASA and NOAA Earth observations, and numerical weather model products using scripts written in the Google Colaboratory Python scripting environment. In addition to designing the deep learning architecture, the team trained and tested the model, and evaluated its performance using the Nash-Sutcliffe Efficiency (NSE). The final product, called the Sequentially Trained Real-time EstimAted Model (STREAM), predicts stage height for the Hudson Branch gauge in Ellicott City using data products available in near real-time, including the High-Resolution Rapid Refresh (HRRR) model’s accumulated precipitation forecasts supplemented by stream gauge data from the OEM and the U.S. Geological Survey. STREAM was incorporated into an online dashboard in a user-friendly interface capable of triggering the alarms that initiate the OEM’s emergency response protocols up to 8 hours in advance of a predicted severe flood event. The project demonstrated the potential for the integration of open data and Earth observations into a flood risk forecasting tool capable of informing near real-time decision making.

Ryan Hammock↗

Case Study: Seattle Waterfront Networked Microgrid Evaluation - Case Study for Port Electrification Handbook

Many ports and waterfronts are evaluating alternative electrification efforts, including electrification of passenger and vehicle ferries. In Seattle, the Washington State Department of Transportation, in conjunction with Seattle City Light (the local utility) and the Port of Seattle, are working to deploy a hybrid electric ferry and provide charging at Seattle’s Colman dock. As part of this ferry electrification effort, Seattle City Light is considering including a large battery energy storage system (BESS) to help “buffer” the ferry charging. The “buffer” provides energy arbitrage and spreads out the large amount of power needed to recharge the ferry to times when the ferry is out of the dock – rather than one very large peak for 15 minutes, the battery storage allows it to be a smaller power value over a longer duration. This initial BESS concept served as the jumping off point to explore an expanded microgrid concept via a notional test system that incorporates additional distributed energy resources (DER) and infrastructure upgrades to the local distribution infrastructure at the Seattle Waterfront and neighboring Port of Seattle properties. This case study examined the potential for secondary use of the BESS within a networked microgrid during the scenario of a large-scale power outage, such as a natural disaster.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Subcontracted activities related to TES for building heating and cooling

The subcontract program elements related to thermal energy storage for building heating and cooling systems are outlined. The following factors are included: subcontracts in the utility load management application area; life and stability testing of packaged low cost energy storage materials; and development of thermal energy storage systems for residential space cooling. Resistance storage heater component development, demonstration of storage heater systems for residential applications, and simulation and evaluation of latent heat thermal energy storage (heat pump systems) are also discussed. Application of thermal energy storage for solar application and twin cities district heating are covered including an application analysis and technology assessment of thermal energy storage.

Martin, J.↗

Reliable, Secure, and Scalable Communications, Navigation, and Surveillance (CNS) Options for Urban Air Mobility (UAM)

The Aeronautics Research Mission Directorate directed a study to identify, evaluate, and recommend viable communications, navigation, and surveillance systems and technologies to enable safe, secure, and efficient Urban Air Mobility operations in US cities. The focus is on UML-4, when commercial air taxi operations take place in all weather, are widespread, and include autonomous systems. This report recommends technologies for independent navigation, collaborative communication, and surveillance, based on capacity, availability, precision, and update rate, size, weight, power, cost and other values. Recommendations for maturing and implementing the technologies are included.

Virginia L. Stouffer↗

The relative importance of building design parameters in reducing energy use and sensible heat release from buildings in light of forecasted future weather data and building coverage ratio

Buildings typically have a 60-to-75-year lifespan before they require significant maintenance or modifications. However, most builders evaluate the performance of their new buildings using whole-building energy simulation tools based on the current typical meteorological year (TMY) file or actual meteorological year. The energy use consumption and sensible heat release pattern observed from buildings could potentially change based on shifting global climates. Therefore, the recommended energy-efficiency design parameters might also change during these periods. In this study, we evaluate the role of different building design parameters, such as material reflectivity, HVAC COP, and insulation values, on building energy usage and sensible heat release from buildings with different building coverage ratios (BCR), based on the current and future weather file TMY (fTMY) for the middle of the century (2040–2060). The role of sensible heat release from buildings is not accounted for accurately while estimating building energy usage in most whole-building energy simulations. The study conducts a series of whole-building energy simulation analyses using EnergyPlus to evaluate the role of different design parameters based on TMY and fTMY weather conditions. The analysis is conducted for two hot desert climatic cities: Phoenix (USA) and Abu Dhabi (UAE). The results show that, for the base case in a future climate, the sensible heat release is reduced by an average of 30% due to the reduced delta T between the surface and ambient air. Further, the results show an increase in total energy consumption by 5% annually. The results also show that, for buildings with traditional coatings, shorter buildings release more heat than taller buildings. On the other hand, for buildings with reflective paints, shorter buildings release less heat than taller buildings. The findings from this study can be used by policymakers, utility companies, and builders to better understand the relative role of different building design parameters while constructing new and retrofitting existing buildings.

Alhazmi, Mansour [King Fahd University of Petroleu↗

The quest for improved air quality may push China to continue its CO 2 reduction beyond the Paris Commitment

China is challenged with the simultaneous goals of improving air quality and mitigating climate change. The “Beautiful China” strategy, launched by the Chinese government in 2020, requires that all cities in China attain 35 μg/m 3 or below for annual mean concentration of PM 2.5 (particulate matter with aerodynamic diameter less than 2.5 μm) by 2035. Meanwhile, China adopts a portfolio of low-carbon policies to meet its Nationally Determined Contribution (NDC) pledged in the Paris Agreement. Previous studies demonstrated the co-benefits to air pollution reduction from implementing low-carbon energy policies. Pathways for China to achieve dual targets of both air quality and CO 2 mitigation, however, have not been comprehensively explored. Here, we couple an integrated assessment model and an air quality model to evaluate air quality in China through 2035 under the NDC scenario and an alternative scenario (Co-Benefit Energy [CBE]) with enhanced low-carbon policies. Results indicate that some Chinese cities cannot meet the PM 2.5 target under the NDC scenario by 2035, even with the strictest end-of-pipe controls. Achieving the air quality target would require further reduction in emissions of multiple air pollutants by 6 to 32%, driving additional 22% reduction in CO 2 emissions relative to the NDC scenario. Results show that the incremental health benefit from improved air quality of CBE exceeds 8 times the additional costs of CO 2 mitigation, attributed particularly to the cost-effective reduction in household PM 2.5 exposure. The additional low-carbon energy polices required for China’s air quality targets would lay an important foundation for its deep decarbonization aligned with the 2 °C global temperature target.

54 ENVIRONMENTAL SCIENCES↗

Utilizing NASA Earth Observations to Evaluate Urban Tree Canopy and Land Surface Temperature for Green Infrastructure Development and Urban Heat Mitigation in Huntsville, AL

Huntsville, Alabama’s population has grown by 10.8% since 2010, due in part to the city’s advancing engineering industry. Rapid urban growth negatively impacts the environment by decreasing tree canopy cover and increasing impervious surface cover, which can intensify the urban heat island effect. To examine the impacts of this urban growth on the environment, the team partnered with the City of Huntsville to utilize Landsat 5 Thematic Mapper (TM), Landsat 8 Operational Land Imager (OLI), Landsat 8 Thermal Infrared Sensor (TIRS), Terra Moderate Resolution Imaging Spectroradiometer (MODIS) and the International Space Station’s Global Ecosystems Dynamic Investigation (GEDI) and ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS). The team utilized these Earth observations in combination with ancillary datasets to create a suite of end products to assist in mitigating the effects of extreme heat due to urban expansion and tree canopy loss. Rasters of annual land surface temperature (LST) was calculated in Google Earth Engine from 2010 to 2019. The team derived land cover classes through supervised and threshold classification methods to distinguish trees, other vegetation types, impervious surfaces, and water. From 2010 to 2019, LST increased approximately 4 °F for all census tracts within the city and the total amount of tree cover increases less than 3%. The findings will aid the city in future decision-making processes by indicating areas that would benefit from increased green infrastructure.

Greta Paris↗

Huntsville Urban Development II: Utilizing NASA Earth Observations to Map the Urban Heat Island and Evaluate Vulnerability in Huntsville, Alabama

Huntsville, Alabama has seen a boom in growth over recent years. One consequence of this urban expansion is the exacerbation of the Urban Heat Island (UHI) effect across the city. This project identified the areas within Huntsville the greatest potential for heat reduction and community health benefits from tree-planting efforts. The team created maps of land surface temperature (LST), the normalized difference vegetation index (NDVI), and the normalized difference built-up index (NDBI) over June through August from 2019 to 2022 using data from ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station, Landsat 8 Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS), Landsat 9 OLI-2 and TIRS-2. The team identified areas with high LST, low NDVI, and high NDBI as areas with the greatest potential for heat reduction via tree-planting. Social factors relating to age, race, income, and self-reported health were adapted from Tree Equity Score to map community need for tree cover. When combining social with environmental factors, the team determined areas with the greatest potential for UHI mitigation: west-central and north downtown Huntsville. The team’s partner organization, the City of Huntsville, can use this priority map to guide their future tree-planting, and weigh the factors assessed according to their preference.

James Karroum↗

Two-Way Option Contracts That Facilitate Adaptive Water Reallocation in the Western United States

Many water markets in the western United States (U.S.) have the ability to reallocate water temporarily during drought, often as short-term water rights leases from lower value irrigated activities to higher value urban uses. Regulatory approval of water transfers, however, typically takes time and involves high transaction costs that arise from technical and legal analyses, discouraging short-term leasing. This leads municipalities to protect against drought-related shortfalls by purchasing large volumes of infrequently used permanent water rights. High transaction costs also result in municipal water rights rarely being leased back to irrigators in wet or normal years, reducing agricultural productivity. This research explores the development of a multi-year two-way option (TWO) contract that facilitates leasing from agricultural-to-urban users during drought and leasing from urban-to agricultural users during wet periods. The modeling framework developed to assess performance of the TWO contracts includes consideration of the hydrologic, engineered, and institutional systems governing the South Platte River Basin in Colorado where there is growing competition for water between municipalities (e.g., the city of Boulder) and irrigators. The modeling framework is built around StateMod, a network-based water allocation model used by state regulators to evaluate water rights allocations and potential rights transfers. Results suggest that the TWO contracts could allow municipalities to maintain supply reliability with significantly reduced rights holdings at lower cost, while increasing agricultural productivity in wet and normal years. Additionally, the TWO contracts provide irrigators with additional revenues via net payments of option fees from municipalities.

54 ENVIRONMENTAL SCIENCES↗

SRB Materials and Processes Assessment from Laboratory and Ocean Environmental Tests

The Materials and Processes Laboratory evaluation of Solid Rocket Boosters (SRB) and Solid Rocket Motors (SRM) candidate material, both in-house and with ocean exposure tests at Panama City and Kennedy Space Center (KSC), Florida is presented. Early sample tests showed excellent seawater corrosion resistance for inconel 718 and titanium 6A1-4V alloys. Considerable corrosion and biofouling occurred with bare 2219-T87 aluminum. Subsequent tests conclusively demonstrated that epoxy coatings prevented corrosion of 2219-T87 aluminum as long as the coatings stays intact. The results and assessment of the series of ocean environmental tests that were conducted are also presented.

Source record↗

Simulations of Sparse Static Detector Networks for City-Scale Radiological/Nuclear Detection

Sparse static detector networks in urban environments can be used in efforts to detect illicit radioactive sources, such as stolen nuclear material or radioactive "dirty bombs." We use detailed simulations to evaluate multiple configurations of detector networks and their ability to detect sources moving through a $6\times 6$ km 2 area of downtown Chicago. A detector network's probability of detecting a source increases with detector density but can also be increased with strategic node placement. Here, we show that the ability to fuse correlated data from a source-carrying vehicle passing by multiple detectors can significantly contribute to the overall detection probability. In this article, we distinguish static sensor deployments operated as networks able to correlate signals between sensors, from deployments operated as arrays where each sensor is operated individually. In particular, we show that additional visual attributes of source-carrying vehicles, such as vehicle color and make, can greatly improve the ability of a detector network to detect illicit sources.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Huntsville Urban Development: Utilizing NASA Earth Observations to Evaluate Urban Tree Canopy and Land Surface Temperature for Green Infrastructure Development and Urban Heat Mitigation in Huntsville, AL

Huntsville, Alabama’s population has grown by approximately 11% since 2010, due in part to the city’s advancing engineering industry. Rapid urban growth negatively impacts the environment by decreasing tree canopy cover and increasing impervious surface cover, which can intensify the urban heat island effect. To examine the impacts of this urban growth on the environment, the team partnered with the City of Huntsville to utilize Landsat 5 Thematic Mapper (TM), Landsat 8 Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS), Terra Moderate Resolution Imaging Spectroradiometer (MODIS) and the International Space Station’s Global Ecosystems Dynamic Investigation (GEDI) and ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS). The team utilized these Earth observations in combination with ancillary datasets to create a suite of end products to assist in mitigating the effects of extreme heat due to urban expansion and tree canopy loss. Annual land surface temperature (LST) was calculated and land cover classes were derived through supervised and threshold classification methods to distinguish trees, other vegetation types, impervious surfaces, and water. From 2010 to 2019, LST increased approximately 4 °F for all census tracts within the city and the total amount of tree cover increased by approximately 3%. The findings will aid the city in future decision-making processes by indicating areas that would benefit from increased green infrastructure.

Greta Paris↗

Huntsville Urban Development: Utilizing NASA Earth Observations to Evaluate Urban Tree Canopy and Land Surface Temperature for Green Infrastructure Development and Urban Heat Mitigation in Huntsville, Alabama

Huntsville, Alabama’s population has grown by approximately 11% since 2010, due in part to the city’s advancing engineering industry. Rapid urban growth negatively impacts the environment by decreasing tree canopy cover and increasing impervious surface cover, which can intensify the urban heat island effect. To examine the impacts of this urban growth on the environment, the team partnered with the City of Huntsville to utilize Landsat 5 Thematic Mapper (TM), Landsat 8 Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS), Terra Moderate Resolution Imaging Spectroradiometer (MODIS) and the International Space Station’s Global Ecosystems Dynamic Investigation (GEDI) and ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS). The team utilized these Earth observations in combination with ancillary datasets to create a suite of end products to assist in mitigating the effects of extreme heat due to urban expansion and tree canopy loss. Annual land surface temperature (LST) was calculated and land cover classes were derived through supervised and threshold classification methods to distinguish trees, other vegetation types, impervious surfaces, and water. From 2010 to 2019, LST increased approximately 4 °F for all census tracts within the city and the total amount of tree cover increased by approximately 3%. The findings will aid the city in future decision-making processes by indicating areas that would benefit from increased green infrastructure.

Greta Paris↗

Subsurface Characterization for Evaluating Geothermal Resource Potential from Existing Oil and Gas Wells in Tuttle, Oklahoma

Oil and gas (O&G) wells often encounter co-produced hot water, possibly suitable for geothermal direct-use applications. The City of Tuttle is located on the eastern part of the Anadarko sedimentary basin in Oklahoma with high heat-in-place potential and recovery capability at depth. This study aims at demonstrating the potential of geothermal energy production for direct-use applications in two public schools and 250 nearby houses in Tuttle via repurposing existing O&G wells. In this scope, geochemistry, geology, and borehole log data were collected and incorporated into a 3D conceptual subsurface model. A digital elevation model (DEM) was used to represent the study area topography with four O&G wells. In addition, hydrogeochemical characteristics of the geothermal fluid and scaling potential were analyzed using ternary diagrams and chemical ratios to develop mixing models. The subsurface geology model indicated that the study area primarily consists of Permian to Mississippian Sandstone and Limestone formations, implying a porosity ranging between 12% and 22%, and a permeability up to 3.90E-14 m2 in certain reservoir levels. The reservoir temperature is expected to be ranging between 80 degrees C to 95 degrees C around 3 km depth with an average temperature gradient of 22.8 degrees C/km. Chemical geothermometers also estimated the reservoir temperature as 90 degrees C. Findings of the chemical model demonstrated that the geothermal fluid is Sodium-Potassium-Chloride-Sulfate type and possibly mixed with shallow groundwater resulting in higher Ca and Mg concentrations and lower Na/K ratio implying lower calcite scaling. These results comprehensively characterize the potential of geothermal resources in the study area and imply that geothermal energy production by repurposing existing O&G wells is suitable for low-temperature direct-use applications.

gas wells↗

Subsurface Characterization for Evaluating Geothermal Resource Potential from Existing Oil and Gas Wells in Tuttle, Oklahoma: Preprint

Oil and gas (O&G) wells often encounter co-produced hot water, possibly suitable for geothermal direct-use applications. The City of Tuttle is located on the eastern part of the Anadarko sedimentary basin in Oklahoma with high heat-in-place potential and recovery capability at depth. This study aims at demonstrating the potential of geothermal energy production for direct-use applications in two public schools and 250 nearby houses in Tuttle via repurposing existing O&G wells. In this scope, geochemistry, geology, and borehole log data were collected and incorporated into a 3D conceptual subsurface model. A digital elevation model (DEM) was used to represent the study area topography with four O&G wells. In addition, hydrogeochemical characteristics of the geothermal fluid and scaling potential were analyzed using ternary diagrams and chemical ratios to develop mixing models. The subsurface geology model indicated that the study area primarily consists of Permian to Mississippian Sandstone and Limestone formations, implying a porosity ranging between 12% and 22%, and a permeability up to 3.90E-14 m2 in certain reservoir levels. The reservoir temperature is expected to be ranging between 80 degrees C to 95 degrees C around 3 km depth with an average temperature gradient of 22.8 degrees C/km. Chemical geothermometers also estimated the reservoir temperature as 90 degrees C. Findings of the chemical model demonstrated that the geothermal fluid is Sodium-Potassium-Chloride-Sulfate type and possibly mixed with shallow groundwater resulting in higher Ca and Mg concentrations and lower Na/K ratio implying lower calcite scaling. These results comprehensively characterize the potential of geothermal resources in the study area and imply that geothermal energy production by repurposing existing O&G wells is suitable for low-temperature direct-use applications.

GEOTHERMAL ENERGY↗