Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

SeaWiFS calibration and algorithm validation

A substantial amount of field research has been completed during this period (1 October 1994 - 31 October 1995). The applicability of different in-flight calibration methods was studied. In addition, various field instruments and new equipment were tested to appraise their usefulness during such calibration activities. The purposes and (expected) results of these field experiments are detailed in separate sections of this report. One section contains a synopsis of calibrations conducted over both land and water targets. A second section contains the results of an experiment conducted to determine the spatial uniformity of surface reflectance at Lake Tahoe, the chosen water calibration site. Advances were also made in the area of radiative transfer software development. An existing exact radiative transfer code, Successive Orders (SO), was modified to provide outputs of the radiance distribution at arbitrary altitudes above a selected calibration target. These modifications were needed to utilize the SO software in radiance-based sensor calibrations. Serious thought was given to the general applicability of various calibration techniques to calibrations conducted over water surfaces. In particular, the practicality of the radiance-based and reflectance-based methods of in-flight radiometric calibration was evaluated.

Parada, Robert J., Jr.↗

Flood hazard model calibration using multiresolution model output

Riverine floods pose a considerable risk to many communities. Improving flood hazard projections has the potential to inform the design and implementation of flood risk management strategies. Current flood hazard projections are uncertain, especially due to uncertain model parameters. Calibration methods use observations to quantify model parameter uncertainty. With limited computational resources, researchers typically calibrate models using either relatively few expensive model runs at high spatial resolutions or many cheaper runs at lower spatial resolutions. This leads to an open question: is it possible to effectively combine information from the high and low resolution model runs? We propose a Bayesian emulation–calibration approach that assimilates model outputs and observations at multiple resolutions. As a case study for a riverine community in Pennsylvania, we demonstrate our approach using the LISFLOOD-FP flood hazard model. Here, the multiresolution approach results in improved parameter inference over the single resolution approach in multiple scenarios. Results vary based on the parameter values and the number of available models runs. Our method is general and can be used to calibrate other high dimensional computer models to improve projections.

multiresolution↗

A new rapid method of solar simulator calibration

A quick method for checking solar simulator spectra content is presented. The method is based upon a solar cell of extended spectral sensitivity and known absolute response, and a dichroic mirror with the reflection transmission transition close to the peak wavelength of the Thekaekara AMO distribution. It compromises the need for spectral discrimination with the ability to integrate wide spectral regions of the distribution which was considered important due to the spiky nature of the high pressure xenon lamp in common use. The results are expressed in terms of a single number, the blue/red ratio, which, combined with the total (unfiltered) output, provides a simple adequate characterization. Measurements were conducted at eleven major facilities across the country and a total of eighteen simulators were measured including five pulsed units.

Ross, B.↗

Evaluation of Wing Load Calibration and Sensing Methods Using Conventional Strain Gages and a Fiber Optic Sensing System Installed on a Straight Tapered Wing

State-of-the-art instrumentation techniques have provided an opportunity to obtain greater insight into structural wing loads during flight. An investigation was undertaken to research new wing instrumentation and load sensing techniques for measuring accurate in-flight spanwise load distributions on wing structures. A straight tapered wing was instrumented with both conventional foil strain gages at five spanwise wing stations and fiber optic strain sensors at every half inch along the entire wing span. Thirty-nine unique load cases were applied to the wing lower surface using hydraulic actuators to obtain various shear, bending moment, and torque load distributions on the wing. This paper will highlight three load calibration approaches. Conventional linear regression calibration methods were applied to foil strain gages providing a single wing station vertical shear, bending moment, and torque load. Linear regression methods were applied to a fiber optic sensing system to provide bending moment and torque spanwise load distributions. A load sensing scheme using strain derived wing shape information derived from a single load case provided vertical shear and bending moment spanwise load distribution information. Aspects of the three different approaches will be compared and contrasted to inform the reader of the benefits or disadvantages of each. Instrument installation, sensor characteristics, test execution aspects, and recommended calibration techniques will be discussed.

structural mechanics↗

Results of calibrations of the NOAA-11 AVHRR made by reference to calibrated SPOT imagery at White Sands, N.M

The calibration method reported here makes use of the reflectances of several large, uniform areas determined from calibrated and atmospherically corrected SPOT Haute Resolution Visible (HRV) scenes of White Sands, New Mexico. These reflectances were used to predict the radiances in the first two channels of the NOAA-11 Advanced Very High Resolution Radiometer (AVHRR). The digital counts in the AVHRR image corresponding to these known reflectance areas were determined by the use of two image registration techniques. The plots of digital counts versus pixel radiance provided the calibration gains and offsets for the AVHRR. A reduction in the gains of 4 and 13 percent in channels 1 and 2 respectively was found during the period 1988-11-19 to 1990-6-21. An error budget is presented for the method and is extended to the case of cross-calibrating sensors on the same orbital platform in the Earth Observing System (EOS) era.

Nianzeng, Che↗

The throughput calibration of the VERITAS telescopes

Context. The response of imaging atmospheric Cherenkov telescopes to incident γ -ray-initiated showers in the atmosphere changes as the telescopes age due to exposure to light and weather. These aging processes affect the reconstructed energies of the events and γ -ray fluxes. Aims. This work discusses the implementation of signal calibration methods for the Very Energetic Radiation Imaging Telescope Array System (VERITAS) to account for changes in the optical throughput and detector performance over time. Methods. The total throughput of a Cherenkov telescope is the product of camera-dependent factors, such as the photomultiplier tube gains and their quantum efficiencies, and the mirror reflectivity and Winston cone response to incoming radiation. This document summarizes different methods to determine how the camera gains and mirror reflectivity have evolved over time and how we can calibrate this changing throughput in reconstruction pipelines for imaging atmospheric Cherenkov telescopes. The implementation is validated against seven years of observations with the VERITAS telescopes of the Crab Nebula, which is a reference object in very-high-energy astronomy. Results. Regular optical throughput monitoring and the corresponding signal calibrations are found to be critical for the reconstruction of extensive air shower images. The proposed implementation is applied as a correction to the signals of the photomultiplier tubes in the telescope simulation to produce fine-tuned instrument response functions. This method is shown to be effective for calibrating the acquired γ -ray data and for recovering the correct energy of the events and photon fluxes. At the same time, it keeps the computational effort of generating Monte Carlo simulations for instrument response functions affordably low.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration of Hot Wire Anemometers. (Latest Citations from the Aerospace Database)

The bibliography contains citations concerning calibration methods and measurement correction schemes for hot wire anemometers. Coverage includes static and dynamic calibration of sensors having single, multiple, cross, and ring wire configurations. Correction methods to account for yaw angle, low-velocity flow, microgravity, wall proximity, and highly fluctuating turbulence, velocity, or temperature are covered. Correction methods are also referenced for installations having multiple sensors. Hot film and laser anemometers, and the use of anemometers in specific industrial and aerospace applications are extensively covered in separate biblographies. (Contains 50-250 citations and includes a subject term index and title list.)

HOT WIRE ANEMOMETERS↗

Aquarius Instrument Science Calibration During the Risk Reduction Phase

This final report presents the results of work performed under NASA Grant NAG512726 during the period 15 January 2003 through 30 June 2004. An analysis was performed of a possible vicarious calibration method for use by Aquarius to monitor and stabilize the absolute and relative calibration of its microwave radiometer. Stationary statistical properties of the brightness temperature (T(sub B)) measured by a low Earth orbiting radiometer operating at 1.4135 GHz are considered as a means of validating its absolute calibration. The global minimum, maximum, and average T(sub B) are considered, together with a vicarious cold reference method that detects the presence of a sharp lower bound on naturally occurring values for T(sub B). Of particular interest is the reliability with which these statistics can be extracted from a realistic distribution of T(sub B) measurements that would be observed by a typical sensor. Simulations of measurements are performed that include the effects of instrument noise and variable environmental factors such as the global water vapor and ocean surface temperature, salinity and wind distributions. Global minima can vary widely due to instrument noise and are not a reliable calibration reference. Global maxima are strongly influenced by several environmental factors as well as instrument noise and are even less stationary. Global averages are largely insensitive to instrument noise and, in most cases, to environmental conditions as well. The global average T(sub B) varies at only the 0.1 K RMS level except in cases of anomalously high winds, when it can increase considerably more. The vicarious cold reference is similarly insensitive to instrument effects and most environmental factors. It is not significantly affected by high wind conditions. The stability of the vicarious reference is, however, found to be somewhat sensitive (at the several tenths of Kelvins level) to variations in the background cold space brightness, T(sub c). The global average is much less sensitive to this parameter and so using two approaches together can be mutually beneficial.

Ruf, Christopher S.↗

Uncertainties for Pre- and Post-Launch Radiometric Calibration of Imaging Spectrometers for Multi-Sensor Applications

An important aspect to using imaging spectrometer data is the radiometric characterization and calibration of the sensors and validation of their data products and doing so with error budgets with known traceability. The radiometric accuracy of a given sensor is important for demonstrating the expected quality of data from the sensor. Known traceability allows data from multiple sensors to be directly comparable as will become more important in the near future with the expected launches of multiple imaging spectrometers from multiple countries, agencies, and commercial entities. The current work describes the state of pre- and post-launch radiometric absolute and relative uncertainties and their role in harmonising on-orbit data. Examples of prelaunch uncertainties based on the calibration of EnMAP and the calibration planned for the CLARREO Pathfinder Mission are presented highlighting recent work in the area of detector-based approaches using tunable laser sources. Post-launch calibration approaches for Pathfinder, EnMAP, CHIME, and DESIS including traditional vicarious calibration methods and the challenges of working with commercial data are presented. The vicarious calibration discussion relies on the example of the recently-available RadCalNet data to describe typical methods and challenges that will be faced when harmonising data between imaging spectrometers as well as with multispectral sensors.

Thome, K.↗

CaliQEC: In-situ Qubit Calibration for Surface Code Quantum Error Correction

Quantum Error Correction (QEC) is essential for fault-tolerant, large-scale quantum computation. However, error drift in qubits undermines QEC performance during long computations, necessitating frequent calibration. Conventional calibration methods disrupt quantum states, requiring system downtime and rendering in situ calibration impractical. To address this challenge, we propose QECali, a novel framework that enables in situ calibration for surface codes. Our evaluation demonstrates that QECali introduces modest qubit overhead and negligible increases in execution time, offering the first practical solution for in situ calibration in surface code based quantum computation.

Fang, Xiang [University of California, Santa Barba↗

The Dark Energy Survey Six-Year Calibration Star Catalog

This Technical Note presents a catalog of calibrated reference stars that was generated by the Forward Calibration Method (FGCM) pipeline (arXiv:1706.01542) as part of the FGCM photometric calibration of the full Dark Energy Survey (DES) 6-Year data set (Y6). This catalog provides DES grizY magnitudes for 17 million stars with i-band magnitudes mostly in the range 16 < i < 21 spread over the full DES footprint covering 5000 square degrees over the Southern Galactic Cap at galactic latitudes b < -20 degrees (plus a few outlying fields disconnected from the main survey footprint). These stars are calibrated to a uniformity of better than 1.8 milli-mag (0.18%) RMS over the survey area. The absolute calibration of the catalog is computed with reference to the STISNIC.007 spectrum of the Hubble Space Telescope CalSpec standard star C26202; including systematic errors, the absolute flux system is known at the approximately 1% level. As such, these stars provide a useful reference catalog for calibrating grizY-band or grizY-like band photometry in the Southern Hemisphere, particularly for observations within the DES footprint.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Variations in in-flight absolute radiometric calibration

Variations in the in-flight absolute radiometric calibration of the Coastal Zone Color Scanner and the Thematic Mapper (TM) are reviewed. At short wavelengths, the sensors show a gradual reduction in response, while in the mid-IR the TM shows oscillatory variations. One set of measurements made at White Sands, New Mexico shows anomalous results in TM bands 2 and 4. The results of a reflectance-based and a radiance-based calibration method at White Sands are described. An analysis of the radiance-based method shows the value of such measurements from helicopter altitudes for calibration.

Slater, Philip N.↗

Method and apparatus for precision control of radiometer

A radiometer controller of a radiation detector is provided with a calibration method and apparatus comprised of mounting all temperature sensitive elements of the controller in thermostatically controlled ovens during calibration and measurements, using a selected temperature that is above any which might be reached in the field. The instrument is calibrated in situ by adjusting heater power (EI) to the receptor cavity in the radiometer detector to a predetermined full scale level and is displayed by a meter.

Estey, R. S.↗

Long-term thermal stability and calibration of Type-II fiber Bragg grating array inscribed in radiation-hardened fibers

This paper investigates the long-term thermal stability of Type-II fiber Bragg grating (FBG) arrays, inscribed by femtosecond laser in radiation-hardened fiber, for potential applications as multiplexed sensors in high-temperature energy systems. The thermal stability of FBG sensors was assessed through 16 thermal cycles from room temperature (RT) to 750 ℃ about two months, involving 100 FBG sensors. The results show that the absolute temperature drift of FBG sensors can be reduced to less than 0.4 pm/day after 54 h thermal annealing process at a constant temperature of 800 ℃. As temperature sensors, the FBGs demonstrated stable performance, achieving a standard deviation (STD) of 1.8 pm (corresponding to a temperature resolution of 0.118 ℃) post-annealing. Repeated thermal cycles revealed a random drift of 2.3 pm in the FBG wavelength at RT. Polynomial fitting was explored as a calibration method to convert FBG wavelength shifts into absolute temperature measurements. By optimizing calibration temperature points (RT, 200 ℃, 400 ℃, and 750 ℃), the study shows that cubic polynomial calibration using four points yields an average R2 of 0.9997 and an RMSE of 3.58 ℃ across the entire temperature range (RT to 750 ℃). This approach represents an 11.53-fold improvement over empirical slope calibration and a 1.34-fold improvement over four-point piecewise fitting. The findings indicate that Type-II FBGs inscribed in radiation-hardened fibers can function as accurate temperature sensors, with performance on par with or exceeding that of thermocouples. With their multiplexing capability, robust signal transmission over long lead cables, and immunity to electromagnetic interference, FBG sensors offer a promising alternative to traditional electronic sensors for energy system monitoring.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗

Radiometric Calibration Techniques for Signal-of-Opportunity Reflectometers

Bi-static reflection measurements utilizing global navigation satellite service (GNSS) or other signals of opportunity (SoOp) can be used to sense ocean and terrestrial surface properties. End-to-end calibration of GNSS-R has been performed using well-characterized reflection surface (e.g., water), direct path antenna, and receiver gain characterization. We propose an augmented approach using on-board receiver electronics for radiometric calibration of SoOp reflectometers utilizing direct and reflected signal receiving antennas. The method calibrates receiver and correlator gains and offsets utilizing a reference switch and common noise source. On-board electronic calibration sources, such as reference switches, noise diodes and loop-back circuits, have shown great utility in stabilizing total power and correlation microwave radiometer and scatterometer receiver electronics in L-band spaceborne instruments. Application to SoOp instruments is likely to bring several benefits. For example, application to provide short and long time scale calibration stability of the direct path channel, especially in low signal-to-noise ratio configurations, is directly analogous to the microwave radiometer problem. The direct path channel is analogous to the loopback path in a scatterometer to provide a reference of the transmitted power, although the receiver is independent from the reflected path channel. Thus, a common noise source can be used to measure the gain ratio of the two paths. Using these techniques long-term (days to weeks) calibration stability of spaceborne L-band scatterometer and radiometer has been achieved better than 0.1. Similar long-term stability would likely be needed for a spaceborne reflectometer mission to measure terrestrial properties such as soil moisture.

calibrating↗

Derivation of the final OSIRIS-REx OVIRS in-flight radiometric calibration

The OSIRIS-REx Visible and InfraRed Spectrometer (OVIRS) operates over the ∼0.4- to 4.3-μm wavelength range. Radiometric calibration over this broad range requires the use of multiple calibration sources. Initial OVIRS in-flight calibration coefficients were previously computed using ground calibration from visible integrating sphere and IR blackbody sources, cross-calibrated with Earth-observing satellites for visible wavelengths, and adjusted using the spectrum of the OSIRIS-REx mission’s target body, asteroid (101955) Bennu. As part of the final in-flight calibration, we determined that the best calibration method removes out-of-band IR signal leakage prior to radiometric calibration and updated the calibration coefficients accordingly. These final calibration coefficients work well for data where the field of view is filled, and we document the possible artifacts in underfilled spots.

Amy A. Simon↗

Time-walk and jitter correction in SNSPDs at high count rates

Superconducting nanowire single-photon detectors (SNSPDs) are a leading detector type for time correlated single photon counting, especially in the near-infrared. When operated at high count rates, SNSPDs exhibit increased timing jitter caused by internal device properties and features of the RF amplification chain. Variations in RF pulse height and shape lead to variations in the latency of timing measurements. To compensate for this, we demonstrate a calibration method that correlates delays in detection events with the time elapsed between pulses. The increase in jitter at high rates can be largely canceled in software by applying corrections derived from the calibration process. We demonstrate our method with a single-pixel tungsten silicide SNSPD and show it decreases high count rate jitter. The technique is especially effective at removing a long tail that appears in the instrument response function at high count rates. At a count rate of 11.4 MCounts/s, we reduce the full width at 1% maximum level (FW1%M) by 45%. The method, therefore, enables certain quantum communication protocols that are rate-limited by the FW1%M metric to operate almost twice as fast.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TPSAS-NF1676L-10863-DND

One important aspect of successful climate monitoring is satellite calibration. There is at least a 25-year of operational geostationary (GEO) record available for climate studies, if properly calibrated. The Global Space-based Inter-Calibration System (GSICS) project is another effort to provide the climate community consistent calibration across multiple platforms. Also, the Clouds and the Earth's Radiant Energy System (CERES) project, provides consistent GEO retrieved cloud properties and derived broadband fluxes across multiple platforms. This year GSICS is focusing on geostationary visible channel calibration. The GSICS strategy is to use multiple approaches, such as cross-calibrating the GEO radiances against MODIS as a reference, deep convective clouds as bright stable targets, deserts, sun-glint, stars, moon and other model based calibration methods. Each of these methods is independent of each other and can assess the stability of the GEO visible instrument with differing uncertainties. This study focuses on the inter-calibration of the GEO radiances against MODIS as a reference by using collocated, and coincident ray-matched radiances. The advantage of the ray-matching technique is that it provides a full dynamic range of radiances to check the linearity of the GEO visible instrument. This presentation will focus on the technique, some error analysis, comparisons with other methods, and an approach to inter-calibrate historical GEOs before MODIS.

D R Doelling↗