Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibrated”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

XCal: model-based approach to X-ray CT spectral calibration

Transmission X-ray computed tomography (CT) is widely used to quantitatively reconstruct 3D objects composed of multiple materials. However, accurate CT reconstruction requires the system to be calibrated to account for the effective X-ray spectrum. Unfortunately, measurement of the effective spectrum is ill-posed, and existing calibration methods require that the system be recalibrated when the system parameters are changed. In this paper, we propose XCal, a multi-energy model-based spectral calibration approach for X-ray CT. The XCal approach models the effective spectrum using a separable physics-based model of the CT system. The model parameters are then estimated by fitting calibration data with known objects at multiple energies. An important advantage of XCal is that it allows the user to change scanner settings, such as the source voltage or X-ray filters, without the need for recalibration. Evaluations on simulated and measured datasets demonstrate that XCal significantly improves the accuracy of the estimated spectrum as compared to existing calibration methods.

Li, Wenrui [Purdue Univ., West Lafayette, IN (Unit↗

Calibration and modification of the constitutive model for the mechanical response of P91

The objective of this first milestone was to calibrate and if necessary, modify a constitutive model predicting the primary and secondary creep response of P91. The overall path to be followed consists of first calibrating this constitutive model against experimental data available from the literature (this milestone). In parallel, data acquired by indentation tests will be used to calibrate the model (this involves transforming the indentation data into equivalent uniaxial tests). An overall comparison of model parameters will allow assessing to what extent these rapid tests can be used to calibrate models predicting the overall mechanical response of the bulk. Given that COVID naturally hindered the gathering of new experimental data, the choice was made to ensure that LANL would have sufficient funds in year two to perform the bulk of the new calibration work. The following report details (i) how and which of the bulk experimental data was selected, (ii) constitutive model formulation, (iii) predictions of the constitutive model: effects of imposed stress, temperature and precipitate content, (iv) future work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary Calibration System Report for High-Temperature Irradiation-Resistant Thermocouples

An established calibration procedure is presented for the high-temperature irradiation-resistant thermocouple (HTIR-TC). Standard calibration curves for both an individual (i.e. case by case basis) and common calibrations is shown. The error limits within ±3 σ are ±1% for the individual calibrations and ±2% for the common calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Spectacular Viscoelastic Model Calibration for 828/D230/Alox Generated from Legacy Sandia Data

The nonlinear viscoelastic Spectacular model is calibrated to the thermo-mechanical behavior of 828/D230/Alox with an alox volume fraction of 20 %. Legacy experimental data from Sandia’s polymer properties database (PPD) is used to calibrate the model. Based on known densities of the epoxy 828/D230 and the alox filler, the alox volume fractions listed on the PPD were likely reported incorrectly. The alox volume fractions are recalculated here. Using the recalculated alox volume fractions, the PPD contains experimental data for 828/D230/Alox with alox volume fractions of 16 %, 24 %, and 33 %, so the thermo-mechanical behavior at 20 % alox volume fraction is estimated by interpolating between the bounding cases of of 16 % and 24 %. Because the Spectacularmodel can be fairly challenging to calibrate, the calibration procedure is described in detail. Several of the calibration steps involve inverse parameter identification, where an experiment is simulated and parameters are iteratively updated until the model response matches the experimental data. As the PPD does not fully describe all experimental procedures, the experimental simulations use assumed thermal and mechanical loading rates that are typical for the viscoelastic characterization of epoxies. Spectacular uses four independent relaxation functions related to volumetric (ƒ 1 ), shear (ƒ 2 ), thermal strain (ƒ 3 ), and thermal relaxations (ƒ 4 ). The previous SPEC model form, also known as the universal_polymer model, uses two independent relaxation functions related to volumetric and thermal relaxation (ƒ ν = ƒ 1 = ƒ 3 = ƒ 4 ) and shear relaxation (ƒ s = ƒ 2 ). The two constitutive choices are briefly evaluated here, where it is found that the four relaxation function approach of Spectacular was better suited for fitting the coefficient of thermal expansion during both heating and cooling.

36 MATERIALS SCIENCE↗

Automated Calibration System for Beam Current Monitor

The Beam Current Monitor (BCM) measures the instantaneous current in a beam. This work aims to develop an automated calibration system for the BCM to address the need for calibration without interrupting beam operation. We strive to create a synchronous calibration method integrated into the master timeline by utilizing the pulsed nature of synchrotrons to run calibration pulses during inter-pulse gaps. This improvement should enhance operational efficiency, ensure safe operation, and help mitigate beam loss, all by enabling intermittent calibration during the operation of the accelerator. This is accomplished by developing a Python program that interfaces with a Keithley 6221 DC and AC source and a Keithley 2182A Nanovoltmeter. The program configures both of these devices to perform a selected mode of the current sweep, allows for the initiation of the current sweep, collects the measured voltage data from the 2182A, stores the collected data to the computer in a CSV file, and graphs the collected data.

Haller, James↗

Calibration of Al7075 with Plate-Puncture Predictions

The following details calibration of a material model for Al7075-T6511. This aluminum alloy is commonly used across a host of engineering applications. Owing to its widespread prevalence, there is great benefit in improving simulation predictions for this alloy. In the present effort, a calibration is performed of its elastic-plastic response accounting for both rate and temperature dependence. The calibration is informed by a series of tests that include specimens of different geometries tested at different rates and temperatures. All specimens are derived from the same barstock, 3.5 inches in diameter. The fitted model itself uses an anisotropic, Hill yield surface coupled with a Johnson-Cook hardening model. Failure predictions are had by means of a modified Wilkins failure criterion. Following calibration of the material model, a validation exercise is performed against platepuncture experiments. These experiments include multiple probe shapes, probe diameters, and plate thicknesses. The puncture experiments are replicated in simulation with mesh studies performed to assess uncertainty. Key quantities of interest, notably the absorbed energy up to failure, are compared between simulation and experiment providing a means to assess the suitability of the calibration in puncture simulations.

36 MATERIALS SCIENCE↗

Performance and automatic calibration scheme of the waveform sampler in the ETROC2 ASIC chip

The waveform sampler in the CMS ETROC2 chip for LGAD gain aging monitoring is a 2.56-GS/s 12-bit 8x-Interleaved ADC that consists of a coarse SAR stage, and a fine stage. This architecture delivers high performance on a relatively modest 65 nm process, while requires finding up to 24 calibration constants through calibration. We developed an automatic calibration method using charge injection test data. After calibration, the baseline random error is reduced by a factor of 2.5–3 compared to the default calibration, and a 5% charge measurement precision is achieved in 15 fC charge injection tests.

Fu, Tao [Unlisted, US]↗

SBND Calibration

The Short-Baseline Near Detector (SBND) is a 112-ton liquid argon time projection chamber (LArTPC) serving as the near detector of the Short-Baseline Neutrino Program at Fermilab. SBND aims to make precise measurements of neutrino-argon interactions, necessitating an extensive calibration program for the LArTPC to ensure precision/accuracy in these measurements. This talk describes the use of cosmogenic, radiogenic, and neutrino interaction activity with both Monte Carlo simulation and data in calibrating the SBND subsystems of the Time Projection Chamber, Photon Detection System, and Cosmic Ray Tagger. We will highlight some of SBND's first calibration results, including electronics calibrations, measurement of the electron lifetime, shower calibration, and studies of space charge effects in the detector.

Oh, Sungbin [Fermilab]↗

Photon Detection System Calibration for DUNE

Photon Detection System Calibration for DUNE Not scheduled 20m Conference Center (University of California, Irvine) Poster New Technologies for Neutrino Physics Poster session Speaker Denis Torres (South Dakota School of Mines and Technology) Description The Deep Underground Neutrino Experiment (DUNE) is a long baseline neutrino oscillation experiment that relies on a precise Photon Detection System (PDS) to provide accurate timing information, enhance sensitivity to low-energy and non-beam events, and support detector performance studies in liquid argon time projection chambers. Achieving these goals requires a well-understood and stable optical calibration strategy that operates reliably under cryogenic conditions. In this poster, I will present PDS calibration studies performed in ProtoDUNE, focusing on the characterization of the ultraviolet (UV) light calibration system and key optical components in the light-delivery chain. I will discuss measurements of optical fiber transmission, SMA-to-SMA connector and feedthrough interface losses, and diffuser assemblies, emphasizing wavelength dependence, attenuation, and performance under cryogenic thermal cycling and stability tests. These studies provide quantitative inputs for understanding light transport, uniformity, and long-term reliability of the PDS in large-scale liquid argon detectors, and they directly inform calibration strategies for the DUNE Far Detector.

Torres Muñoz, Denis [South Dakota Sch. Mines Tech.↗

Calibration of the Mu2e momentum scale using $\pi^{+}\rightarrow e^{+}\nu_{e}$ decays

The Mu2e experiment at Fermilab will search for the neutrinoless muon-to-electron conversion in the nuclear field by stopping negative muons on an Al target. The experimental signature of $\mu^{-}$ to $e^{-}$ conversion on Al is the observation of mono-energetic electrons with 104.97 MeV produced by the lepton violating reaction. Rejection of one of the most important experimental backgrounds coming from muon Decays-In-Orbit requires a momentum resolution $<1\%$ FWHM and a momentum scale calibrated to an accuracy of better than $0.1\%$ or $0.1$ MeV at an electron energy of $\sim$100 MeV. Among other momentum scale calibration techniques, the collaboration is considering using 68.9 MeV positrons from decays of stopped positive pions. This calibration measurement has a significant background dominated by the muon decays-in-flight affecting the calibration accuracy. In this article, we discuss the momentum calibration measurement results.

Tripathy, Sridhar [UC, Davis (main)] (ORCID:000000↗

Validation of Calibrated k–ε Model Parameters for Jet-in-Crossflow

Previous efforts determined a set of calibrated, optimal model parameter values for Reynolds-averaged Navier–Stokes (RANS) simulations of a compressible jet in crossflow (JIC) using a $k–ε$ turbulence model. These parameters were derived by comparing simulation results to particle image velocimetry (PIV) data of a complementary JIC experiment under a limited set of flow conditions. Here, a $k–ε$ model using both nominal and calibrated parameters is validated against PIV data acquired from a much wider variety of JIC cases, including a realistic flight vehicle. The results from the simulations using the calibrated model parameters showed considerable improvements over those using the nominal values, even for cases that were not used in the calibration procedure that defined the optimal parameters. This improvement is demonstrated using a number of quality metrics that test the spatial alignment of the jet core, the magnitudes of multiple flow variables, and the location and strengths of vortices in the counter-rotating vortex cores on the PIV planes. These results suggest that the calibrated parameters have applicability well outside the specific flow case used in defining them and that with the right model parameters, RANS solutions for the JIC can be improved significantly over those obtained from the nominal model.

42 ENGINEERING↗

The Open Cluster Chemical Abundances and Mapping Survey. VII. APOGEE DR17 [C/N]–Age Calibration

Large-scale surveys open the possibility to investigate Galactic evolution both chemically and kinematically; however, reliable stellar ages remain a major challenge. Detailed chemical information provided by high-resolution spectroscopic surveys of the stars in clusters can be used as a means to calibrate recently developed chemical tools for age-dating field stars. Using data from the Open Cluster Abundances and Mapping survey, based on the Sloan Digital Sky Survey/Apache Point Observatory Galactic Evolution Experiment 2 survey, we derive a new empirical relationship between open cluster stellar ages and the carbon-to-nitrogen ([C/N]) abundance ratios for evolved stars, primarily those on the red giant branch. With this calibration, [C/N] can be used as a chemical clock for evolved field stars to investigate the formation and evolution of different parts of our Galaxy. We explore how mixing effects at different stellar evolutionary phases, like the red clump, affect the derived calibration. We have established the [C/N]–age calibration for APOGEE Data Release 17 (DR17) giant star abundances to be $\mathrm{log}{[\mathrm{Age}(\mathrm{yr})]}_{\mathrm{DR}17}=10.14\,(\pm 0.08)+2.23(\pm 0.19)\,[{\rm{C}}/{\rm{N}}]$, usable for $8.62\leqslant \mathrm{log}(\mathrm{Age}[\mathrm{yr}])\leqslant 9.82$, derived from a uniform sample of 49 clusters observed as part of APOGEE DR17 applicable primarily to metal-rich, thin- and thick-disk giant stars. This measured [C/N]–age APOGEE DR17 calibration is also shown to be consistent with asteroseismic ages derived from Kepler photometry.

79 ASTRONOMY AND ASTROPHYSICS↗

RTN-117: Image Calibration and Instrument Signal Removal for the First Year of the LSST

The NSF-DOE Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST) requires calibration products that provide uniform, stable, and accurate photometric and astrometric performance across the 3.2 gigapixel focal plane and throughout the 10-year survey. This paper details the algorithms and workflows used to produce instrument calibrations and remove instrumental artifacts for Data Preview 2 (DP2)---the first end-to-end processing demonstration using on-sky data with the LSST Camera (LSSTCam). We describe the verification, acceptance, and certification framework used to assess calibration quality and quantify residual systematics. We show baseline metrics on calibrated science images to evaluate the robustness of the calibration and instrument signature removal (ISR) data processing pipelines for DP2. Finally, we summarize the known limitations observed in DP2 production and outline expected algorithmic improvements for the first public LSST data release (Data Release~1, DR1).

79 ASTRONOMY AND ASTROPHYSICS↗

Experiments and numerical modeling of surrogate droplet combustion for a 93 octane gasoline calibration fuel

Gasoline is the world’s most prolific liquid transportation fuel for ground transportation vehicles. Yet, a fundamental understanding of its burning characteristics is still lacking. Complicating this matter is the highly multicomponent nature of gasoline (comprised of hundreds of chemical species) and the seasonable variability of its composition due to variations in the crude oil feedstocks used in refining. The need to bring order to this complex problem has led to development of calibration fuels (Tier II in presented study) which on average will provide repeatable metrics that replicate performance of refined gasoline for various engine designs. This study presents results of experiments using the configuration of an isolated droplet to study the combustion dynamics of calibration fuel and three different surrogates (S4, S5, S6) for the calibration fuel. Droplet burning is under microgravity conditions, where gas transport is determined entirely by fuel evaporation in order to promote spherical symmetry in the burning process. The initial droplet diameters ranged between 0.55 mm and 0.60 mm. The droplets were spark-ignited and their burning histories were recorded by digital video cameras to obtain quantitative data. For each fuel, the evolutions of droplet, flame, and soot-shell diameters were measured to calculate the burn rates, flame-droplet diameter ratios (FSR) and soot-droplet diameter ratios. Additionally, a detailed numerical modeling is presented. This simulation includes multicomponent phase equilibrium, unsteady gas and liquid transport, radiative heat transfer, internal liquid diffusion and detailed combustion chemistry of different fuels during their burning process. Experiment results show that the calibration fuel and surrogates have a close burn rates and FSR, and S5 presents a relatively similar results with calibration fuel. Predictions from the numerical simulation using the surrogate are compared with experiment measurements, which showed a good agreement with the experiment results, including the droplet burning rate and FSR.

Guo, Songtao↗

Trial-based calibration for audio-based identification, recognition, and detection system

The disclosed technologies include methods for generating a calibration model using data that is selected to match the conditions of a particular trial that involves an automated comparison of data samples, such as a comparison-based trial performed by an audio-based recognition, identification, or detection system. The disclosed technologies also include improved methods for selecting candidate data used to build the calibration model. The disclosed technologies further include methods for evaluating the performance of the calibration model and for rejecting a trial when not enough matched candidate data is available to build the calibration model. The disclosed technologies additionally include the use of regularization and automated data generation techniques to further improve the robustness of the calibration model.

McLaren, Mitchell Leigh↗

Bayesian optimization for inverse calibration of expensive computer models: A case study for Johnson-Cook model in machining

Inverse model calibration for identifying the constitutive model parameters can be computationally demanding for expensive-to-evaluate simulation models. Here, this paper presents a modified Bayesian optimization (BO) method, denoted as BO-bound, that incorporates theoretical bounds on the quantity of interest. A case study for the inverse calibration of the Johnson Cook (J-C) flow stress model parameters is presented using machining (cutting) force data. The results show fast calibration of the five J-C parameters within 25 simulations. In general, the BO-bound method is applicable for inverse calibration of any expensive simulation models as well as optimization problems with known bounds.

Bayesian optimization↗

Flood hazard model calibration using multiresolution model output

Riverine floods pose a considerable risk to many communities. Improving flood hazard projections has the potential to inform the design and implementation of flood risk management strategies. Current flood hazard projections are uncertain, especially due to uncertain model parameters. Calibration methods use observations to quantify model parameter uncertainty. With limited computational resources, researchers typically calibrate models using either relatively few expensive model runs at high spatial resolutions or many cheaper runs at lower spatial resolutions. This leads to an open question: is it possible to effectively combine information from the high and low resolution model runs? We propose a Bayesian emulation–calibration approach that assimilates model outputs and observations at multiple resolutions. As a case study for a riverine community in Pennsylvania, we demonstrate our approach using the LISFLOOD-FP flood hazard model. Here, the multiresolution approach results in improved parameter inference over the single resolution approach in multiple scenarios. Results vary based on the parameter values and the number of available models runs. Our method is general and can be used to calibrate other high dimensional computer models to improve projections.

multiresolution↗

Calibration and uncertainty quantification for Davis Equation of State models for the High Explosive PBX 9501 products

Abstract This paper investigates the uncertainty in the parameters used in the calibration of an Davis Equation Of State (EOS) for the detonation products of the High Explosive PBX 9501. The procedure sought to make use of all available information about this HE to inform the best set of calibration parameters as well as the uncertainty in these parameters. The procedure made use of historical experimental data, the results from thermo‐chemical modeling as well as data on the best isentrope function fit to cylinder test experimental data. Combining all these heterogeneous data sources together in a Bayesian calibration, yielded a posterior mean and covariance. Sampling from the posterior distribution and evaluating an important Quantity Of Interest (QOI) in the EOS model, the detonation speed of a one‐inch rate stick, produced a distribution which showed variations which were in agreement with experiments. The uncertainty in the EOS was reported as eleven sets of model calibrations which spanned the range of this QOI.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗