Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “blind system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Hybrid AlGaN-SiC Avalanche Photodiode for Deep-UV Photon Detection

The proposed device is capable of counting ultraviolet (UV) photons, is compatible for inclusion into space instruments, and has applications as deep- UV detectors for calibration systems, curing systems, and crack detection. The device is based on a Separate Absorption and Charge Multiplication (SACM) structure. It is based on aluminum gallium nitride (AlGaN) absorber on a silicon carbide APD (avalanche photodiode). The AlGaN layer absorbs incident UV photons and injects photogenerated carriers into an underlying SiC APD that is operated in Geiger mode and provides current multiplication via avalanche breakdown. The solid-state detector is capable of sensing 100-to-365-nanometer wavelength radiation at a flux level as low as 6 photons/pixel/s. Advantages include, visible-light blindness, operation in harsh environments (e.g., high temperatures), deep-UV detection response, high gain, and Geiger mode operation at low voltage. Furthermore, the device can also be designed in array formats, e.g., linear arrays or 2D arrays (micropixels inside a superpixel).

Aslam, Shahid↗

Z-2 Threaded Insert Design and Testing

NASA's Z-2 prototype space suit contains several components fabricated from an advanced hybrid composite laminate consisting of IM10 carbon fiber and fiber glass. One requirement was to have removable, replaceable helicoil inserts to which other suit components would be fastened. An approach utilizing bonded in inserts with helicoils inside of them was implemented. During initial assembly, cracking sounds were heard followed by the lifting of one of the blind inserts out of its hole when the screws were torqued. A failure investigation was initiated to understand the mechanism of the failure. Ultimately, it was determined that the pre-tension caused by torqueing the fasteners is a much larger force than induced from the pressure loads of the suit which was not considered in the insert design. Bolt tension is determined by dividing the torque on the screw by a k value multiplied by the thread diameter of the bolt. The k value is a factor that accounts for friction in the system. A common value used for k for a non-lubricated screw is 0.2. The k value can go down by as much as 0.1 if the screw is lubricated which means for the same torque, a much larger tension could be placed on the bolt and insert. This paper summarizes the failure investigation that was performed to identify the root cause of the suit failure and details how the insert design was modified to resist a higher pull out tension.

Ross, Amy↗

Motorized Beam Alignment of a Commercial X-ray Diffractometer

X-ray diffraction (XRD) is a powerful analysis method that allows researchers to noninvasively probe the crystalline structure of a material. This includes the ability to determine the crystalline phases present, quantify surface residual stresses, and measure the distribution of crystallographic orientations. The Structures and Materials Division at the NASA Glenn Research Center (GRC) heavily uses the on-site XRD lab to characterize advanced metal alloys, ceramics, and polymers. One of the x-ray diffractometers in the XRD lab (Bruker D8 Discover) uses three different x-ray tubes (Cu, Cr, and Mn) for optimal performance over numerous material types and various experimental techniques. This requires that the tubes be switched out and aligned between experiments. This alignment maximizes the x-ray tube s output through an iterative process involving four set screws. However, the output of the x-ray tube cannot be monitored during the adjustment process due to standard radiation safety engineering controls that prevent exposure to the x-ray beam when the diffractometer doors are open. Therefore, the adjustment process is a very tedious series of blind adjustments, each followed by measurement of the output beam using a PIN diode after the enclosure doors are shut. This process can take up to 4 hr to perform. This technical memorandum documents an in-house project to motorize this alignment process. Unlike a human, motors are not harmed by x-ray radiation of the energy range used in this instrument. Therefore, using motors to adjust the set screws will allow the researcher to monitor the x-ray tube s output while making interactive adjustments from outside the diffractometer. The motorized alignment system consists of four motors, a motor controller, and a hand-held user interface module. Our goal was to reduce the alignment time to less than 30 min. The time available was the 10-week span of the Lewis' Educational and Research Collaborative Internship Project (LERCIP) summer internship program and the budget goal was $1200. In this report, we will describe our motorization design and discuss the results of its implementation.

Van Zandt, Noah R.↗

Time Course of Effects of Carbon Dioxide Exposure on Physical and Cognitive Performance in a Simulated Surface Extravehicular Activity Contingency Scenario

INTRODUCTION Carbon dioxide (CO 2 ) is a metabolic byproduct produced by humans that must be scrubbed from the atmosphere by environmental control and life support systems in space vehicles and spacesuits to prevent buildup. Current nominal CO 2 limits are set by NASA Standard 3001, however, limits during contingency situations are not specified. The purpose of this study was to characterize and quantify the physiological, cognitive, and self-assessed symptom and performance metrics as a function of inspired CO 2 (P I CO 2 ) during a simulated 1-hour contingency lunar EVA scenario in virtual reality (VR). METHODS Fifteen healthy subjects completed 7 simulated EVA scenarios walking on a passive treadmill for one hour breathing dry, ambient air mixed with added CO 2 in a blind, counterbalanced manner (P I CO 2 : 0, 5, 10, 15, 20, 25, 30 mmHg) simulating a 2.0 km contingency EVA walkback to a habitat on the lunar surface in the event of a CO 2 scrubber malfunction. Subjects were immersed in a Lunar VR environment and asked to maintain their walking speed between 2.1 km/h and an upper limit individually calibrated to a fixed metabolic workload of 1.3 L/min of O 2 consumption, and performed periodic cognitive tasks and continuous cardiopulmonary measurements. Self-assessments of symptoms and task performance were measured via verbal Likert-scale survey at the onset of the walkback and at 10-minute intervals thereafter. RESULTS The time course of cardiopulmonary, cognitive, and self-reported responses at each level of P I CO 2 will be presented. All 15 subjects were able to complete the 1-hr walk back task at all CO 2 levels. Physiological responses were rapid, typically within 1 to 5 minutes. No effects of time were detected for cognitive measures. Symptomatic ratings of headache, shortness of breath, and fatigue demonstrated a time-course development, reaching asymptote after 40 minutes of CO 2 exposure. DISCUSSION These findings will inform the posture of risk associated with CO 2 exposure on human health and performance during microgravity and planetary surface operations, This will help inform decisions related to space suit and environmental life support hardware requirements and EVA operational limits for contingency extravehicular activity (EVA) scenarios.

carbon dioxide↗

Operation of a microchannel plate counting system in a mass spectrometer

A multiplier detector system has been developed as part of a mass spectrometer in an ion counting mode. During its operation ions striking a microchannel plate release pulses of electrons which are accelerated to a phosphor layer. The resulting flash of light is carried by a fiber-optic bundle to a photodiode array. The detector simultaneously counts ions throughout a mass spectrum covering more than 30 amu. It extends the mass spectrometer's operation toward low count rates for trace gas analysis. Each mass peak can be independently measured at count rates between 0.1 and 1000 counts/s. Higher rates on a few peaks do not blind the entire detector. The detector's capabilities have been demonstrated by measuring Kr and Xe isotopes in air at natural abundances. The mass spectrometer, detector, and readout electronics are sufficiently compact to permit use in a balloon-borne experiment.

Murphy, D. M.↗

Membrane-Based Gas Traps for Ammonia, Freon-21, and Water Systems to Simplify Ground Processing

Gas traps are critical for the smooth operation of coolant loops because gas bubbles can cause loss of centrifugal pump prime, interference with sensor readings, inhibition of heat transfer, and blockage of passages to remote systems. Coolant loops are ubiquitous in space flight hardware, and thus there is a great need for this technology. Conventional gas traps will not function in micro-gravity due to the absence of buoyancy forces. Therefore, clever designs that make use of adhesion and momentum are required for adequate separation, preferable in a single pass. The gas traps currently used in water coolant loops on the International Space Station are composed of membrane tube sets in a shell. Each tube set is composed of a hydrophilic membrane (used for water transport and capture of bubbles) and a hydrophobic membrane (used for venting of air bubbles). For the hydrophilic membrane, there are two critical pressures, the pressure drop and the bubble pressure. The pressure drop is the decrease in system pressure across the gas trap. The bubble pressure is the pressure required for air bubbles to pass across the water filled membrane. A significant difference between these pressures is needed to ensure complete capture of air bubbles in a single pass. Bubbles trapped by the device adsorb on the hydrophobic membrane in the interior of the hydrophilic membrane tube. After adsorption, the air is vented due to a pressure drop of approximately 1 atmosphere across the membrane. For water systems, the air is vented to the ambient (cabin). Because water vapor can also transport across the hydrophobic membrane, it is critical that a minimum surface area is used to avoid excessive water loss (would like to have a closed loop for the coolant). The currently used gas traps only provide a difference in pressure drop and bubble pressure of 3-4 psid. This makes the gas traps susceptible to failure at high bubble loading and if gas venting is impaired. One mechanism for the latter is when particles adhere to the hydrophobic membrane, promoting formation of a water layer about it that can blind the membrane for gas transport (Figure 1). This mechanism is the most probable cause for observed failures with the existing design. The objective of this project was to devise a strategy for choosing new membrane materials (database development and procedure), redesign of the gas trap to mitigate blinding effects, and to develop a design that can be used in ammonia and Freon-21 coolant loops.

Ritchie, Stephen M. C.↗

Progress on the Development of a Simulation Environment for Optical Communications

Deep space laser communications require extremely accurate beam pointing to take advantage of the narrow beams achievable at optical wavelengths. This pointing accuracy must be achieved in the presence of spacecraft basebody motion which may exceed laser pointing requirements by orders of magnitude.In this paper a model of an optical band transceiver pointing control system is developed that can be used to predict performance under various operating scenarios. The transceiver model consists of an electro-mechanical model of the telescope platform and isolator. A novel photon counting detector array is used in the simulation as the focal plane detector. In the simulation we are able to inject various cases of spacecraft basebody motion based on both flight data and future mission spacecraft jitter requirements. Various models of uplink beacon flux levels and atmospheric scintillation are also available for analysis.Using these models, detector processing and control functions are implemented in the simulation. A complete acquisition sequence is demonstrated with blind acquisition and tracking of the modulated uplink beam and positioning of the downlink beam on the focal plane array. These simulations predict that pointing requirements will be met with representative disturbance models and uplink beam scintillation.

pointing control↗

Vision Systems Illuminate Industrial Processes

When NASA designs a spacecraft to undertake a new mission, innovation does not stop after the design phase. In many cases, these spacecraft are firsts of their kind, requiring not only remarkable imagination and expertise in their conception but new technologies and methods for their manufacture. In the realm of manufacturing, NASA has from necessity worked on the cutting-edge, seeking new techniques and materials for creating unprecedented structures, as well as capabilities for reducing the cost and increasing the efficiency of existing manufacturing technologies. From friction stir welding enhancements (Spinoff 2009) to thermoset composites (Spinoff 2011), NASA s innovations in manufacturing have often transferred to the public in ways that enable the expansion of the Nation s industrial productivity. NASA has long pursued ways of improving upon and ensuring quality results from manufacturing processes ranging from arc welding to thermal coating applications. But many of these processes generate blinding light (hence the need for special eyewear during welding) that obscures the process while it is happening, making it difficult to monitor and evaluate. In the 1980s, NASA partnered with a company to develop technology to address this issue. Today, that collaboration has spawned multiple commercial products that not only support effective manufacturing for private industry but also may support NASA in the use of an exciting, rapidly growing field of manufacturing ideal for long-duration space missions.

Source record↗

Overview and Status of EXCLAIM, the Experiment for Cryogenic Large-Aperture Intensity Mapping

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a balloon-borne far-infrared telescope that will survey star formation history over cosmological time scales to improve our un-derstanding of why the star formation rate declined at redshiftz <2, despite continued clustering of darkmatter. Specifically, EXCLAIM will map the emission of redshifted carbon monoxide and singly ionized carbon lines in windows over a redshift range0< z <3.5, following an innovative approach known asintensity mapping. Intensity mapping measures the statistics of brightness fluctuations of cumulative lineemissions, as opposed to detecting individual galaxies, thus enabling a blind, complete census of the emittinggas. To detect this emission unambiguously, EXCLAIM will cross-correlate with a rich spectroscopic galaxycatalog. The EXCLAIM mission will use a cryogenic design to cool the telescope optics to approximately1.7K. The telescope will feature a90-cm primary mirror to probe spatial scales on the sky from the linearregime up to shot-noise-dominated scales. The telescope optical elements will couple to six μ-Spec spectrom-eter modules, operating over a420–540-GHz frequency band with a spectral resolution of512and featuringMicrowave Kinetic Inductance Detectors (MKIDs). In the baseline design, the detectors will be read out witha Radio Frequency System-on-Chip (RFSoC). The cryogenic telescope and the sensitive detectors will allowEXCLAIM to reach high sensitivity in spectral windows of low emission in the upper atmosphere. Here, anoverview of the mission design and development status since the start of the EXCLAIM project in early 2019 is presented.

Giuseppe Cataldo↗

The critical role of velocity storage in production of motion sickness

We propose that motion sickness is mediated through the orientation properties of velocity storage in the vestibular system that tend to align eye velocity produced by the angular vestibulo-ocular reflex (aVOR) with gravito-inertial acceleration (GIA). (GIA is the sum of the linear accelerations acting on the head. In the absence of translational accelerations, gravity is the GIA.) We further postulate that motion sickness produced by cross-coupled vestibular stimulation can be characterized by a metric composed of the disparity between the axis of eye rotation and the GIA, the strength of the response to angular motion, and the response duration, as determined by the central vestibular time constant, that is, by the time constant of velocity storage. The nodulus and uvula of the vestibulocerebellum are likely to be the central sites where the disparity is sensed, where the vestibular time constants are habituated, and where links are made to the autonomic system to produce the symptoms and signs.

Non-NASA Center↗

Long-Duration Space Flight Provokes Pathologic Q-Tc Interval Prolongation

Space flight has a profound influence on the cardiovascular and autonomic nervous systems. Alterations in baroreflex function, plasma catecholamine concentrations, and arterial pressure regulation have been observed. Changes in autonomic regulation of cardiac function may lead to serious rhythm disturbances. In fact, ventricular tachycardia has been reported during long-duration space flight. The study aim was to determine the effects of space flight on cardiac conduction. Methods and Results: Electrocardiograms (ECGs) and serum electrolytes were obtained before and after short-duration (SD) (4-16 days) and long-duration (LD) (4-6 months) missions. Holter recordings were obtained from 3 different subjects before, during and after a 4-month mission. P-R, R-R, and Q-T intervals were measured manually in a random, blinded fashion and Bazzet's formula used to correct the Q-T interval (Q-Tc). Space flight had no clinically significant effect on electrolyte concentrations. P-R and RR intervals were decreased after SD flight (p<0.05) and recovered 3 days after landing. In the same subjects, P-R and Q-Tc intervals were prolonged after LD flight (p<0.01). Clinically significant Q-Tc prolongation (>0.44 sec) occurred during the first month of flight and persisted until 3 days after landing (p<0.01). Conclusions - Space flight alters cardiac conduction with more ominous changes seen with LD missions. Alterations in autonomic tone may explain ECG changes associated with space flight. Primary cardiac changes may also contribute to the conduction changes with LD flight. Q-Tc prolongation may predispose astronauts to ventricular arrhythmias during and after long-duration space flight.

D'Aunno, DOminick S.↗

Condition sensor system and method

The condition sensor system comprises a condition detector which produces a pulse when a parameter of the monitored condition exceeds a desired threshold. A resettable condition counter counts each pulse. A resettable timer is preset to produce a particular time frame. The counter produces a condition signal when the accumulated number of pulses within the time frame is equal to or greater than a preset count. Control means responsive to the incoming pulses and to the condition signal produce control signals that control utilization devices. After a suitable delay, the last detected pulse simultaneously resets the pulse counter and the timer, and prepares them for sensing another condition occurrence within the time frame. The invention has particular utility in the process of detecting rocking motions of blind people. A controlled, audible, bio-feedback signal is provided which constitutes a warning to the blind person that he is rocking.

Polhemus, J. T.↗

SMOKE: Characterization of Smoke Particulate for Spacecraft Fire Detection

'Smoke' is a flight definition investigation whose purpose is to characterize the smoke particulate from microgravity smoke sources to enable improved design of future space-craft smoke detectors. In the earliest missions (Mercury, Gemini and Apollo), the crew quarters were so cramped that it was considered reasonable that the astronauts would rapidly detect any fire. The Skylab module, however, included approximately 30 UV-sensing fire detectors. The Space Shuttle Orbiter has nine particle-ionization smoke detectors in the mid-deck and flight deck. The detectors for the US segments of the International Space Station (ISS) are laser-diode, forward-scattering, smoke detectors. Current plans for the ISS call for two detectors in the open area of the module, and detectors in racks that have cooling air-flow. Due to the complete absence of microgravity data, all three of these detector systems were designed based upon 1-g test data and experience. As planned mission durations and complexity increase and the volume of spacecraft increases, the need for and importance of effective, crew-independent, fire detection will grow significantly, necessitating more research into microgravity fire phenomena. In 1997 the Comparative Soot Diagnostics Experiment (CSD) flew in the Orbiter Middeck as a Glovebox payload. The CSD experiment was designed to produce small quantities of smoke from several sources to obtain particulate samples and to determine the response of the ISS and Orbiter smoke detectors to these sources. Marked differences in the performance of the detectors compared to their behavior in 1-g were observed. In extreme cases, the detector used in the orbiter was completely blind to easily visible smoke from sources that were readily detected in 1-g. It is hypothesized but as yet unverified that this performance difference was due to enhanced growth of liquid smoke droplets in low-g. These CSD results clearly demonstrate that spacecraft smoke detector design cannot be based on 1-g experience.

Urban, D. L.↗

Restricted by A Historical Review of Strategies and Organization for Restricted Earth Return of Samples from NASA Planetary Missions

Return of samples from the Moon via the Apollo 11, 12 and 14 missions represented NASA's first attempts into conducting what is now known as Restricted Earth Return. When Apollo returned samples from the moon, there were few of the agencies, legal and organizational structures that exist now. A half a century later, the U.S system has seen changes in legal and organizational structures with the appearance of different agencies and legal requirements. During the Apollo era, U.S. legal and organizational structures, assessed threats to the Earth’s biosphere with a priority towards the risks of effects from extraterrestrial pathogens on humans, though the guiding document, the Baylor Protocol, also considered animal and plant models. This presentation focuses on a review of two main questions: Did the return of samples from the Moon happen at a “sweet spot” in time, where the number of requirements and conservatism was commensurate with the scientific knowns and unknowns? Could the emphasis of risk mitigation on human pathogens during the return of extraterrestrial samples be more about human solipsism, leaving us with a blind spot to sources of pathogens, such as fungi, which could lead to an impact to our biosphere, and we humans, via our food chains and agricultural pathways?

planetary protection↗

Simplified Architecture for Precise Aiming of a Deep-Space Communication Laser Transceiver

The simplified architecture is a minimal system for a deep-space optical communications transceiver. For a deepspace optical communications link the simplest form of the transceiver requires (1) an efficient modulated optical source, (2) a point-ahead mechanism (PAM) to compensate for two-way light travel, (3) an aperture to reduce the divergence of the transmit laser communication signal and also to collect the uplink communication signal, and (4) a receive detector to sense the uplink communication signal. Additional components are introduced to mitigate for spacecraft microvibrations and to improve the pointing accuracy. The Canonical Transceiver implements this simplified architecture (see figure). A single photon-counting smart focal plane sensor combines acquisition, tracking, and forward link data detection functionality. This improves optical efficiency by eliminating channel splits. A transmit laser blind sensor (e.g. silicon with 1,550-nm beam) provides transmit beam-pointing feedback via the two-photon absorption (TPA) process. This vastly improves the transmit/receive isolation because only the focused transmit beam is detected. A piezoelectric tiptilt actuator implements the required point-ahead angle. This point-ahead mechanism has been demonstrated to have near zero quiescent power and is flight qualified. This architecture also uses an innovative 100-mHz resonant frequency passive isolation platform to filter spacecraft vibrations with voice coil actuators for active tip-tilt correction below the resonant frequency. The canonical deep-space optical communications transceiver makes synergistic use of innovative technologies to reduce size, weight, power, and cost. This optical transceiver can be used to retire risks associated with deep-space optical communications on a planetary pathfinder mission and is complementary to ongoing lunar and access link developments.

Ortiz, Gerard G.↗

Radio Detection of the Fermi-LAT Blind Search Millisecond Pulsar J1311-3430

We report the detection of radio emission from PSR J1311.3430, the first millisecond pulsar (MSP) discovered in a blind search of Fermi Large Area Telescope (LAT) gamma-ray data. We detected radio pulsations at 2 GHz, visible for less than 10% of approximately 4.5 hr of observations using the Green Bank Telescope (GBT). Observations at 5 GHz with the GBT and at several lower frequencies with Parkes, Nan cay, and the Giant Metrewave Radio Telescope resulted in non-detections. We also report the faint detection of a steep spectrum continuum radio source (0.1 mJy at 5 GHz) in interferometric imaging observations with the Jansky Very Large Array. These detections demonstrate that PSR J1311.3430 is not radio quiet and provide additional evidence that radio-quiet MSPs are rare. The radio dispersion measure of 37.8 pc cm(exp -3) provides a distance estimate of 1.4 kpc for the system, yielding a gamma-ray efficiency of 30%, typical of LAT-detected MSPs. We see apparent excess delay in the radio pulses as the pulsar appears from eclipse and we speculate on possible mechanisms for the non-detections of the pulse at other orbital phases and observing frequencies.

Ray, P. S.↗

Automation and AI in Space Drilling

Future planetary surface sampling missions, such as delving past the near-surface ice layers on Mars in search of organics and possibly signs of past/extant life, will require lightweight, low-mass planetary drilling and sample handling. Unlike terrestrial drills, these exploration drills must work dry (without drilling muds or gas), blind (no prior local or regional seismic or other surveys), and light (very low downward force or weight on bit, and perhaps 100 W available from solar power or batteries). Given the lightspeed transmission delays to Mars and outward, an exploratory planetary drill cannot be controlled directly from Earth. Drills that penetrate deeper than a few centimeters are likely to get stuck if operated open-loop (the MSL drill only penetrates 5 cm, and the MER Rock Abrasion Tools 5 mm by comparison), so some form of local drill control is required. In the relatively near-term, human crews cannot be presumed to be available for surface instrument teleoperation. Therefore highly automated drill and sample-transfer operations will be required, to explore the subsurface with the ability to safe robotic drilling systems and recover and continue on from the most probable fault conditions. Current automation, scheduling and diagnostic approaches will be discussed that roughly track the actions and roles of humans in terrestrial manual drilling operations.

drill automation↗

Stripline/Microstrip Transition in Multilayer Circuit Board

A stripline-to-microstrip transition has been incorporated into a multilayer circuit board that supports a distributed solid-state microwave power amplifier, for the purpose of coupling the microwave signal from a buried-layer stripline to a top-layer microstrip. The design of the transition could be adapted to multilayer circuit boards in such products as cellular telephones (for connecting between circuit-board signal lines and antennas), transmitters for Earth/satellite communication systems, and computer mother boards (if processor speeds increase into the range of tens of gigahertz). The transition is designed to satisfy the following requirements in addition to the basic coupling requirement described above: (1) The transition must traverse multiple layers, including intermediate layers that contain DC circuitry. (2) The transition must work at a frequency of 32 GHz with low loss and low reflection. (3) The power delivered by the transition to top-layer microstrip must be split equally in opposite directions along the microstrip. Referring to the figure, this amounts to a requirement that when power is supplied to input port 1, equal amounts of power flow through output ports 2 and 3. (4) The signal-line via that is necessarily a part of such a transition must not be what is known in the art as a blind via; that is, it must span the entire thickness of the circuit board.

Epp, Larry↗