Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “bill”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Near isothermal compressed air energy storage system in residential and commercial buildings: Techno-economic analysis

Electrical energy storage systems offer a wide range of options to efficiently manage our power supply infrastructure. Energy and environmental security via renewable resources and energy storage devices will also play a critical role in addressing the supply-demand challenges. A novel energy efficient storage system based on near isothermal compressed air energy storage concept, named as Ground-Level Integrated Diverse Energy Storage (GLIDES) is analyzed for integration with residential and commercial buildings. Additionally, the influence of different configurational aspects on key performance and cost attributes is presented in this study. GLIDES modules in the range of 0.5 kWh–15 kWh configurations were considered for residential buildings whereas 25 kW h–500 kW h modules were considered for commercial buildings. Detailed cost and performance analysis of the GLIDES module proved them to be an effective resource in lowering the peak energy demand and corresponding utility bills.

25 ENERGY STORAGE↗

Solar cities: A case study analysis of city-level enablers of expanded solar energy access

Rooftop solar photovoltaic (PV) adoption can benefit households by reducing electricity bills and enhancing energy resiliency. Low and moderate-income (LMI) households have been less likely to adopt PV and experience these benefits in the United States than higher-income households. Adopter income trends are often explored through quantitative analysis with limited explanatory power. Our quantitative analysis only explains around one-third of city-level variation in LMI adoption trends through socioeconomic factors such as median home values and income inequality and PV market factors such as cumulative adoption and incentives. We implement semi-structured interviews in three case studies of cities with relatively high rates of LMI PV adoption to better understand the factors that explain PV adopter income trends. The case studies partly reiterate findings from quantitative analysis, such as the role of PV incentives. The case studies reveal a broader set of LMI adoption drivers that are missed in quantitative analyses. The case studies show how city contexts can affect LMI adoption, such as the role of supportive city governments. The case studies also reveal the importance of partnerships, such as partnerships between city governments and state LMI PV program implementers. Finally, interviewees emphasized the importance of building trust among prospective LMI PV adopters. Interviewees suggested that partnerships, outreach, and consumer protection measures were crucial to building trust in PV installers among LMI households.

Adoption↗

A hierarchical framework for aggregating grid-interactive buildings with thermal and battery energy storage

The behind-the-meter (BTM) thermal and battery energy storage can help improve energy efficiency, reduce energy costs, and enhance energy resilience, particularly in rural areas and for disadvantaged communities. Aggregating numerous BTM energy storage systems can act as a price influencer with a significant source of load shifting and peak demand reduction. An integrated and scalable control mechanism is required to effectively utilize energy storage systems and flexible building loads to maximize the economic benefits, considering various distribution system constraints. Here, this paper presents an innovative hierarchical coordination framework for energy storage and flexible load in buildings, considering various factors such as electricity prices, thermal comfort, and distribution system modeling and constraints. At the upper level, a distribution system operator optimizes the power flow to minimize its power procurement costs from the electricity wholesale market, while at the lower level, aggregators determine the optimal dispatch of battery and thermal energy storage systems in multiple buildings on behalf of end-users to minimize operating costs according to the power prices. These problems are solved using a game-theoretic approach through negotiations between the distribution system operator and aggregators as a bi-level decision model. Simulation case studies have been performed for a test distribution network with a number of building end-users using energy storage systems to quantify the performance of aggregators. The results demonstrate that the proposed strategy can reduce peak load for a reliable electricity distribution network while saving electricity bills for customers.

25 ENERGY STORAGE↗

Recovery of DNA from fired and unfired cartridge casings: comparison of two DNA collection methods

For over 10 years, various studies have attempted to increase the recovery of DNA from ammunition by modifying the DNA collection, extraction, purification, and amplification procedures, with varying levels of success. This study focused on the “soaking” method of Montpetit & O’Donnell [1] and the “rinse-and-swab" method of Bille et al. [2]. First, testing for the presence of exogenous DNA, 210 boxed cartridges (brass, steel, and nickel-plated) from nine manufacturers were swabbed and DNA was extracted, concentrated, and quantified. Extracts that quantified > 0 ng/µL (44 of 210) were amplified and genotyped with GlobalFiler™. Of those, only one extract yielded two alleles indicating that the manufacturing and packaging of ammunition was virtually DNA free. Next, to obtain a baseline comparison of two DNA collection methods on a non-metallic substrate and identify a suitable number of cells to spot on cartridges, different DNA input amounts of primary human adult epidermal keratinocytes (HEKa) were tested. Thereafter, 300 brass and 300 nickel-plated, cartridges were spotted with HEKa cells containing ~5 ng of DNA, fired or unfired, and processed with either method. Finally, five methods representing hybrids of the soaking and rinse-and-swab methods were tested to determine if variations of those methods could be used to increase DNA yield and recovery. The results show that the soaking method consistently yielded more DNA than the rinse-and-swab method from a non-metallic substrate. However, the comparison study demonstrated that both methods performed comparably for cartridges. On average, the soaking method recovered 0.25 ng of DNA (5.1% recovery) and the rinse-and-swab method recovered 0.28 ng (5.8% recovery). However, average recoveries were significantly different among three analysts and considerable variation in yields were observed, possibly due to storage time. Furthermore, consistent with prior reports, the DNA recovered from brass casings was only 16% of that recovered from nickel-plated casings and the average yield of DNA from fired casings was reduced to 67% of unfired casings. Moreover, DNA extracts from brass or nickel-plated casings did not appear to contain amplification inhibitors and only 30/596 appeared severely degraded. Finally, both the published rinse-and-swab and soaking methods yielded more DNA than all modifications of the two methods. Overall, both methods yielded equivalent DNA quantities. Additionally, recovery of DNA from any given cartridge casing may be dependent on storage time as well as the skill, proficiency, and experience of the analyst and may reflect stochastic effects, particularly for casings containing low copy and/or degraded DNA.

59 BASIC BIOLOGICAL SCIENCES↗

Roadmap and Benchmarking: Privacy in Federated Load Forecasting

Data-driven techniques for energy demand forecasting continue to emerge with promising impacts on distribution grid planning. However, the development of robust and generalizable machine learning models requires that representative high quality training data are available. Distributed energy resources have begun to embed intelligence, gathering large amounts of data on customer demand, behavior, and household devices that are connected to the grid. Though utilities aggregate meter-level demand data for load shaping, demand response, outage management, reliability planning, and billing applications, there lies an inherent privacy concern in sharing consumption data that may identify individual consumer behavioral patterns. Hence, while sharing the data is crucial, the private sensitive customer data must be safeguarded from being exposed or manipulated. In this study, we propose a roadmap for implementing a based privacy preserving framework to support the advancement of data-driven analytics in data-sensitive distributed energy resources environments. The roadmap incorporates federated learning–a distributed training framework, differential privacy–a statistical framework that provides guarantees to safeguard the leakage of sensitive data, secure multiparty computation and homomorphic encryption– techniques for encrypting model gradients and applying secure aggregation on the server. Moreover, we perform baseline experiments on the federated short-term load forecasting (STLF) task using open-source residential load profile datasets, offering insights into the challenges of integrating differential privacy into federated learning.

Abebe, Waqwoya [Oak Ridge National Laboratory (ORN↗

The power reliability event simulator tool (PRESTO): A novel approach to distribution system reliability analysis and applications

The growing interest in onsite solar photovoltaic and energy storage systems is partially motivated by customer concerns regarding grid reliability. However, accurately assessing the effectiveness of PVESS in mitigating these interruptions requires a comprehensive understanding of location-specific outage patterns and the ability to simulate realistic scenarios. To address the gap, we introduce the Power Reliability Event Simulation TOol (PRESTO), the first publicly available tool that simulates location-specific power interruptions at the county level. PRESTO allows for a more realistic assessment of system reliability by considering the unpredictability and location-specific patterns of power interruptions. We applied PRESTO in a case study of a single-family home across three U.S. counties, examining the performance of a solar photovoltaic system with 10kWh of battery storage during short-duration power interruptions. Our findings show that this system reliably met 93% of energy demand for essential non-heating and cooling loads, fully serving these loads in 84% of events, despite the constraints of daily time-of-use bill management which limits the battery's state-of-charge reserve. However, when heating and cooling loads were included, system performance decreased significantly, with only 70% of demand met and full service in 43% of events. These results highlight the challenges of using solar photovoltaic and energy storage systems for short-duration outages, emphasizing the need to consider factors like battery size and grid charging strategies to improve reliability. Our study demonstrates the practical applications of PRESTO, providing valuable insights into potential mitigation strategies including grid charging and optimizing battery size.

14 SOLAR ENERGY↗

Heat pumps for all? Distributions of the costs and benefits of residential air-source heat pumps in the United States

Electrification of fossil-fuel combustion in buildings is a key component of achieving global greenhouse gas emissions targets. We use physics simulations of 550,000 statistically representative households to analyze distributions of the costs and benefits of three air-to-air heat pump performance levels, with and without insulation upgrades, across the diversity of the US housing stock. We find positive greenhouse gas reductions in every US state for all performance levels across five 2022-2038 electric grid scenarios, with full adoption reducing national emissions by 5%-9%. We find that air-to-air heat pumps could be cost effective without subsidies in 59% of households (65 million). However, efficiency is key: whereas minimum-efficiency equipment could increase energy bills in 39% of households, this fraction is only 19% when also upgrading insulation or 5% when using higher-efficiency equipment, though both strategies have higher upfront costs. Such affordability challenges could be addressed through supportive incentives, policy, and innovation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

HIV drug resistance during antiretroviral therapy scale-up in Uganda, 2012–19: a population-based, longitudinal study

Background With scale-up of antiretroviral therapy (ART) in sub-Saharan Africa, increasing pretreatment HIV drug resistance has been reported; however, the broader effect of ART expansion on population-level resistance patterns remains insufficiently quantified. We aimed to estimate the longitudinal prevalence of drug resistance and resistance-conferring mutations. Methods This study used data collected as part of the Rakai Community Cohort Study (RCCS), an open population-based census and cohort study conducted in southern Uganda. At each survey round, residents aged 15–49 years are invited to participate and receive a structured questionnaire that obtains sociodemographic, behavioural, and health information, including self-reported past and current ART use. Voluntary HIV testing is conducted using a rapid test algorithm and a venous blood sample. People with HIV provide samples for viral load quantification and deep sequencing. We analysed RCCS survey, HIV viral load, and deep sequencing (which was used to predict resistance) data from five survey rounds. The key outcomes were the population prevalence of viraemic people with HIV with non-nucleoside reverse transcriptase inhibitor (NNRTI), nucleoside reverse transcriptase inhibitor (NRTI), protease inhibitor, or multiclass resistance among all participants (regardless of HIV serostatus) in the 2015 and 2017 surveys. Prevalence of class-specific resistance and resistance-conferring substitutions were estimated using robust log-Poisson regression. Findings Between Aug 10, 2011, and Nov 4, 2020, there were 43 361 participants in the RCCS and 7923 (18·27%) people with HIV. Over five survey rounds, 93 622 participant visits occurred, among which 17 460 (18·65%) were from people with HIV. Over the analysis period, the median age of study participants remained similar (28 years [22–35] in 2012 and 29 years [21–38] in 2019). Sufficient data were available to reliably genotype 4072 (90·03%) of 4523 participant visits from 3407 people with HIV for at least one drug. Overall population prevalence of resistance contributed by viraemic pretreatment people with HIV decreased between 2012 and 2017 from 0·56% (95% CI 0·42–0·75) to 0·25% (0·18–0·33) for NNRTI and from 0·24% (0·15–0·37) to 0·05% (0·02–0·10) for NRTI (prevalence ratio 0·44 [0·29–0·68] for NNRTI and 0·21 [0·09–0·47] for NRTI). Between 2012 and 2017, NNRTI resistance among viraemic pretreatment people with HIV increased from 4·86% (3·69–6·42) to 9·61% (7·27–12·7; prevalence ratio 1·98 [1·34–2·91]). The prevalence of NNRTI and NRTI resistance was substantially higher among viraemic treatment-experienced people with HIV (51·49% [46·24–57·34] for NNRTI and 36·46% [30·06–44·22] for NRTI in 2017) than among pretreatment people with HIV. NNRTI and NRTI resistance was predominantly attributable to rtK103N and rtM184V. inT97A was observed at a similar prevalence among viraemic treatment-experienced (9·96% [6·41–15·48]) and viraemic pretreatment (10·56% [8·01–13·93]) people with HIV; no major dolutegravir resistance mutations were observed. Interpretation Despite rising NNRTI resistance among pretreatment people with HIV, overall population prevalence of pretreatment HIV drug-resistant viraemia decreased due to increasing ART uptake and viral suppression. This finding underscores the crucial role of achieving and maintaining high ART coverage in reducing transmission of drug-resistant HIV. The high prevalence of mutations conferring resistance to components of first-line ART regimens among viraemic people with HIV is potentially concerning. Funding National Institutes of Health, Johns Hopkins University Center for AIDS Research, Bill & Melinda Gates Foundation, and the US Centers for Disease Control and Prevention.

59 BASIC BIOLOGICAL SCIENCES↗

Assessing uncertainty in the timing of energy use during cost-optimal distributed energy technology selection and sizing

This paper empirically derives uncertainty ranges in cost-optimal solar PV and storage sizing by comparing results from the REopt Lite optimization platform from metered data and a set of simulated Department of Energy Commercial Reference Building (CRB) profiles at 65 sites. We find load profile shape alone does not explain a site’s optimal configurations (i.e., PV, Storage, PV and Storage, No System). Still, load profile shape does introduce uncertainty to optimal PV and storage capacities. Across all cases where PV is part of an optimal configuration, we find the average ratio of power capacities derived from metered loads to capacities derived from CRB profiles to be 0.97 (and as high as 1463), where 1 would be a perfect match in system size. For storage, the ratio is 1.6 (and as high as 42). We also assess how, in the absence of complete metered data, a CRB profile can be selected that would be expected to yield the most similar solar PV and storage capacities. From those metrics that can be available from billing data (i.e., peak demand, monthly load totals), we find that uncertainty is most reduced by selecting the CRB’s with an annual peak occurring at the most similar time, or those with the lowest average root mean square error (RMSE) among monthly peak loads. This research can help improve the implementation and interpretation of results derived from simulated load profiles and is an important next step in advancing smart grid solutions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Managing weather- and market price-related financial risks in algal biofuel production

Large-scale algae production has garnered interest due to its potential as a biofuel feedstock. Previous research assessing the profitability of algae products has been mostly based on values averaged over time, but algae production and resulting financial returns exhibit significant variability due to weather and fluctuations in selling prices for algae-based products. In other sectors, producers often reduce weather- and market price-related financial risk with financial instruments such as insurance, but little research has been performed on the design of insurance products to protect algae producers. Furthermore, this study develops a novel index-based insurance instrument that pays-out during unfavorable weather and market conditions, then explores the instrument's effectiveness, combined with a cash reserve, in reducing revenue stream variability for an algae producer. Results indicate that a biophysically based index-insurance product tailored to the specific financial risks in algae production can reduce variability in net revenues and can do so at a lower cost than relying solely on cash reserves, the most common financial risk management tool. Assessing the performance of index-insurance in algae production is particularly timely given the passage of the 2018 Farm Bill, which newly opens opportunities for the USDA to provide crop insurance to algae producers.

09 BIOMASS FUELS↗

Virtual storage capability of residential buildings for sustainable smart city via model-based predictive control

This paper evaluates the virtual storage capability of a residential air-conditioning (AC) system by utilizing the building mass as a thermal storage to enable sustainable cities through model-based predictive control (MPC). The control-oriented building model was developed with a grey-box model structure based on the experimental data to predict the indoor air temperature. Based on the model, the operation cost-saving potential of the MPC was investigated in a single house with different comfort levels, electricity prices, and prediction horizons. The cost-saving of the MPC was approximately 10.6 % compared to the conventional control. The MPC was expanded to a residential building cluster considering the peak demand charge. In an hourly shedding and load-up scenario, the performances of the MPC and the heuristic prior-based control (PBC) are promising. When shedding was enforced all day, the peak demand saving of the MPC was 36~38 %, whereas that of the PBC was 25.7 % compared to the baseline. In addition, the monthly electricity bill, including the operation and peak demand cost, was investigated with different demand charge rates and weather conditions. The total saving decreased with a low demand charge rate and hot conditions, and the operation cost saving was compromised with more aggressive demand shedding.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Economic and embodied energy analysis of integrated circuit manufacturing processes

Integrated circuits (ICs) are the fundamental microelectronic building blocks of typical information and communication technology (ICT) devices such as laptops and smartphone. With the emergence of faster and cheaper low-power ICs for the growing ICT market, there is a limited information on their manufacturing energy and economic impacts owing to the lack of recurrent upgradation of proprietary IC manufacturing process data. In this work, economic and life cycle energy assessments (LCAs) of IC manufacturing and assembly processes were conducted using the latest bill of materials (BOM) manufacturing data in a state-of-the-art IC manufacturing cost software tool developed by IC Knowledge, LLC. IC manufacturing cost was estimated to be $\$$1.00-$\$$5.00/cm 2 ; the high-end cost represents the most advanced 3D NAND IC technology with the Wafer Level Chip Scale Package cost of $4/cm 2 . Total cumulative energy demand (CED) estimates of IC manufacturing using the OpenLCA software ranged from 9 to 38 MJ/cm 2 or 56–235 BJ/month with the largest share (~ 75%) from on-site energy. The IC manufacturing CED is projected to increase with the progress in IC technology node, which has increased by more than two times for technology node evolution from 110 to 14 nm. Furthermore, the representative detailed BOM data were considered to reduce the CED uncertainties of the estimated standard deviation of 35%- 42%.

97 MATHEMATICS AND COMPUTING↗

Coupled management of electric vehicle workplace charging and office building loads

Significant building energy savings are realized through heating, ventilation, and air conditioning (HVAC) setpoint adjustment and daylighting control. Workplace charging (WPC) enables colocation of electric vehicles (EVs) with office building loads. We proposed managing energy use of workplace EV charging and the office building and determined the number of EVs that building energy savings can facilitate charging. We simulated building energy savings in typical medium offices in Chicago IL, Baltimore MD, and Houston TX, spanning three US climate regions. Considering the EV hosting capacity of the saved building energy and travel patterns of roundtrip commuting, we minimized EV charging costs under time-of-use electricity pricing. Managed WPC can reduce charging electricity bills compared to first-come, first-served charging. The ratio of EVs to chargers, the coincident period of commuters’ dwell time and lower electricity prices, and the number of EVs in the office impacted the economic benefits achieved through charging management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Environmental life cycle impacts of small wastewater treatment plants: Design recommendations for impact mitigation

The objective of this study was to quantify potential mitigation of environmental impacts from the operation and construction of wastewater treatment plants (WWTP) from implementing specific design recommendations. The study investigated small WWTPs, many of which are serving slow growing or declining populations. Life Cycle Assessment methodology was used to evaluate and compare the inventory and environmental impacts of nine small WWTP case studies. Detailed inventory data was collected from the facilities’ engineering design plans and utility bills. One recommended practice was to avoid significant overdesign by planning for no lower than a 75% capacity utilization by the facilities’ end-of-life. A theoretical correction to a 75% capacity utilization was estimated to mitigate 0.4% of lifetime electricity usage and 1% of secondary process concrete for every 1% reduction in design average flow rate. Relatedly, a 0.4% mitigation in the Carcinogenic and Global Warming impacts could be achieved for every 1% reduction in design average flow toward a 75% capacity utilization. Other suggested practices were focused on conveyance, namely, to minimize non-process facility area and to use polyvinyl chloride pipe instead of ductile iron pipe where possible. Furthermore, the latter practice was estimated to mitigate between 1.1 and 4.8% of the Carcinogenic impact in the nine case studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Desalination Operations for Energy Flexibility

Despite the value of energy optimization in desalination processes, modeling dynamic operations for monthly billing periods has remained a computational challenge. This work proposes a framework for energy flexibility optimization, which includes new modeling features for independent operation of parallel skids, start-up delays associated with chemical stabilization, the consideration of industrial energy tariff structures, and inclusion of hourly electrical carbon intensities. This is done using a modular and computationally efficient formulation that guarantees a globally optimal solution with standard optimization solvers. In this study, the approach is demonstrated in two distinct case studies: a seawater desalination plant in Santa Barbara, CA, and an indirect potable reuse facility in San Jose, CA. Trends predicted from the model are validated against operational facility measurements from a demand response shutdown event. Preliminary results show that optimizing energy flexibility can result in 18.51% monthly cost savings over energy efficiency-optimized operation. The value extracted from a facility-wide shutdown during peak electricity price hours is hampered by start-up delays in post-treatment chemical stabilization. In cases in which a facility does not have much excess capacity, using a flow equalization tank or operating over a wide recovery range may be cost-effective.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling the potential effects of rooftop solar on household energy burden in the United States

Policymakers at the federal and state level have begun to incorporate energy burden into equity goals and program evaluations, aiming to reduce energy burden below a high level of 6% for lower income households in the United States. Pairing an empirical household-level dataset spanning United States geographies together with modeled hourly energy demand curves, we show that rooftop solar reduces energy burden across a majority of adopters during our study period from a median of 3.3% to 2.6%. For low- and moderate-income adopters (at or below 80% and 120% of area median income, respectively), solar reduces median 2021 energy burden from 7.7% to 6.2%, and 4.1% to 3.3%, respectively. Importantly, solar reduces the rate of high or severe energy burden from 67% of all low-income households before adoption to 52% of households following adoption, and correspondingly from 21% to 13% for moderate-income households. Here, we show rooftop solar can support policy goals to reduce energy burden along with strategies such as weatherization and bill assistance.

14 SOLAR ENERGY↗

Benefits and costs of a utility-ownership business model for residential rooftop solar photovoltaics

The rapid growth of rooftop solar photovoltaic systems can pose a number of financial challenges for electric utility shareholders and their customers. One potential pathway to resolving these perceived challenges involves allowing utilities to own and operate rooftop solar systems. However, the financial benefits and costs of this business model are not well understood. Here we model the financial performance of a large-scale utility-owned residential rooftop solar programme. Furthermore, over a 20 yr period, the programme increases shareholder earnings by 2–5% relative to a no-solar scenario, compared to a 2% earnings loss when an equivalent amount of rooftop solar is instead owned by non-utility parties. Such a programme could therefore be attractive from the perspective of utility investors. The impacts on utility customers, however, are more mixed, with average bills of non-solar customers increasing by 1–3% compared to the no-solar scenario, similar to the 2% increase under traditional, non-utility-ownership structures.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The effect of residential solar on energy insecurity among low- to moderate-income households

Each year, millions of Americans experience energy insecurity, or the inability to afford enough energy to meet their basic needs. Here, this study evaluates whether residential rooftop solar can serve as a preventative solution to energy insecurity among low- to moderate-income households. Using a national, matched sample of solar and non-solar households based on detailed and address-specific data, we find that solar leads to large, robust and salient reductions in five indicators of energy insecurity. Moreover, the benefits of solar ‘spill over’ to improve a household’s ability to pay other energy bills. The results suggest that rooftop solar may be an effective tool for policymakers who seek to reduce energy insecurity.

14 SOLAR ENERGY↗