Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “atomic clock”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Selection and amplification of a single optical frequency comb mode for laser cooling of the strontium atoms in an optical clock

In this paper, we report on the active filtering and amplification of a single mode from an optical femtosecond laser comb with mode spacing of 250 MHz by optical injection of two external-cavity diode lasers operating in cascade to build a narrow linewidth laser for laser cooling of the strontium atoms in an optical lattice clock. Despite the low injection of individual comb mode of approximately 50 nW, a single comb line at 689 nm could be filtered and amplified to reach as high as 10 mW with 37 dB side mode suppression and a linewidth of 240 Hz. This method could be applied over a broad spectral band to build narrow linewidth lasers for various applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparative studies of dipole polarizabilities in Sr{sup +}, Ba{sup +}, and Ra{sup +} and their applications to optical clocks

Static dipole polarizabilities are calculated in the ground and metastable states of Sr{sup +}, Ba{sup +} and Ra{sup +} using the relativistic coupled-cluster method. Trends of the electron correlation effects are investigated in these atomic ions. We also estimate the Stark and black-body radiation shifts from these results for these systems for the transitions proposed for the optical frequency standards and compare them with available experimental data.

74 ATOMIC AND MOLECULAR PHYSICS↗

Hysteresis prediction inside magnetic shields and application

We have developed a simple model that is able to describe and predict hysteresis behavior inside Mumetal magnetic shields, when the shields are submitted to ultra-low frequency (<0.01 Hz) magnetic perturbations with amplitudes lower than 60 μT. This predictive model has been implemented in a software to perform an active compensation system. With this compensation the attenuation of longitudinal magnetic fields is increased by two orders of magnitude. The system is now integrated in the cold atom space clock called PHARAO. The clock will fly onboard the International Space Station in the frame of the ACES space mission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Free Space Ramsey Spectroscopy in Rubidium with Noise below the Quantum Projection Limit

In this work, we demonstrate the utility of optical cavity generated spin-squeezed states in free space atomic fountain clocks in ensembles of 390 000 87 Rb atoms. Fluorescence imaging, correlated to an initial quantum nondemolition measurement, is used for population spectroscopy after the atoms are released from a confining lattice. For a free fall time of 4 milliseconds, we resolve a single-shot phase sensitivity of 814(61) microradians, which is 5.8(0.6) decibels (dB) below the quantum projection limit. We observe that this squeezing is preserved as the cloud expands to a roughly 200 μ m radius and falls roughly 300 μm in free space. Ramsey spectroscopy with 240 000 atoms at a 3.6 ms Ramsey time results in a single-shot fractional frequency stability of 8.4(0.2) × 10 –12 , 3.8(0.2) dB below the quantum projection limit. The sensitivity and stability are limited by the technical noise in the fluorescence detection protocol and the microwave system, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

229Th the Bridge Between Nuclear and Atomic Interactions

The precise measurement of time has been a goal of physicists for centuries. With every new increase in our ability to measure time we have discovered new phenomena. The most advanced clocks available to us currently are atomic clocks that use electronic transitions to track the passage of time. In this proposal, I put forward the framework for the first nuclear clock estimated to be 1000 to 10000 times more precise than the current atomic clocks. This research will explore in detail the atomic nuclear interactions and help perfect and refine current atomic-nuclear interaction models. The realization of a {sup 229}Th nuclear clock will allow tests of cosmology by measuring the change of the fine structure constant as a function of time. The results of these experiments could dramatically alter our view of the universe, its past and future evolution. Precision clocks - with fundamental physics applications - require a long-lived quantum transition (two-level system) that is immune to external perturbations. Nuclear transitions would be better suited than atomic transitions for these applications except that nuclear transitions are typically much higher in energy and therefore cannot be accessed with table-top lasers. There is, however, one promising nuclear transition: the doublet between the ground and first excited states of the {sup 229}Th nucleus discovered by Helmer and Reich. This doublet has an energy splitting of 7.6 {+-} 0.5 eV, a spin difference of 1 h-bar, and an excited state half-life that could be as long as hours. A precision clock based on the {sup 229}Th nuclear doublet has been proposed by Peik et al. Their design is similar to the ion clock research being conducted at NIST in Boulder, CO. However, the NIST researchers use atomic transitions for their frequency standards. In the {sup 229}Th nuclear doublet transition is the frequency standard while atomic transitions are used to cool the ions and for probing the state of the {sup 229}Th nucleus. Recently, Campbell et al. have trapped and cooled {sup 232}Th{sup 3+} at Georgia Institute of Technology. This is a large step forward in the realization of a nuclear clock. The Georgia Tech group is already a collaborator on this project and we are in discussions with the NIST Boulder group about collaboration. In order to determine the suitability of the {sup 229}Th nuclear doublet for a precision clock, the half-life of the excited-state needs to be measured. Current estimates of the half-life vary from 10 {micro}s to 1000 hours. The longer the half-life, the narrower the natural linewidth of the state and the more desirable the transition is for potential applications. In this proposal, I outline the necessary research to be conducted to determine the half-life and exact wavelength of the nuclear doublet transition in {sup 229}Th. This research will lead to a deeper understanding of atomic-nuclear interactions important for our knowledge of high energy density science. It will provide a spectroscopy measurement of the lowest known nuclear transition ever and open the doorway for the development of a nuclear clock with unprecedented precision.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Colloquium: Physics of optical lattice clocks

Recently invented and demonstrated optical lattice clocks hold great promise for improving the precision of modern time keeping. These clocks aim at the 10{sup -18} fractional accuracy, which translates into a clock that would neither lose nor gain a fraction of a second over an estimated age of the Universe. In these clocks, millions of atoms are trapped and interrogated simultaneously, dramatically improving clock stability. Here the principles of operation of these clocks are discussed and, in particular, a novel concept of magic trapping of atoms in optical lattices. Recently proposed microwave lattice clocks are also highlights and several applications that employ the optical lattice clocks as a platform for precision measurements and quantum information processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

p-Wave Cold Collisions in an Optical Lattice Clock

We study ultracold collisions in fermionic ytterbium by precisely measuring the energy shifts they impart on the atoms' internal clock states. Exploiting Fermi statistics, we uncover p-wave collisions, in both weakly and strongly interacting regimes. With the higher density afforded by two-dimensional lattice confinement, we demonstrate that strong interactions can lead to a novel suppression of this collision shift. In addition to reducing the systematic errors of lattice clocks, this work has application to quantum information and quantum simulation with alkaline-earth atoms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three-dimensional optical lattice clock with bosonic {sup 88}Sr atoms

We present detailed analyses of our recent experiment on the three-dimensional (3D) optical lattice clock with bosonic {sup 88}Sr atoms in which the collisional frequency shift was suppressed by applying a single-occupancy lattice. Frequency shifts in magnetically induced spectroscopy on the {sup 1}S{sub 0}-{sup 3}P{sub 0} clock transition ({lambda}=698 nm) of {sup 88}Sr were experimentally investigated by referencing a one-dimensional (1D) lattice clock based on spin-polarized {sup 87}Sr atoms. We discuss that the clock stability is limited by the current laser stability as well as the experimental sequence of the clock operation, which may be improved to {sigma}{sub y}({tau})=2x10{sup -16}/{radical}({tau}) by optimizing the cycle time of the clock operation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Search for variation of fundamental constants and violations of fundamental symmetries using isotope comparisons

Atomic microwave clocks based on hyperfine transitions, such as the caesium standard, tick with a frequency that is proportional to the magnetic moment of the nucleus. This magnetic moment varies strongly between isotopes of the same atom, while all atomic electron parameters remain the same. Therefore the comparison of two microwave clocks based on different isotopes of the same atom can be used to constrain variation of fundamental constants. In this paper, we calculate the neutron and proton contributions to the nuclear magnetic moments, as well as their sensitivity to any potential quark-mass variation, in a number of isotopes of experimental interest including {sup 201,199}Hg and {sup 87,85}Rb, where experiments are underway. We also include a brief treatment of the dependence of the hyperfine transitions to variation in nuclear radius, which in turn is proportional to any change in quark mass. Our calculations of expectation values of proton and neutron spin in nuclei are also needed to interpret measurements of violations of fundamental symmetries.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Clock transitions guard against spin decoherence in singlet fission

Short coherence times present a primary obstacle in quantum computing and sensing applications. In atomic systems, clock transitions (CTs), formed from avoided crossings in an applied Zeeman field, can substantially increase coherence times. We show how CTs can dampen intrinsic and extrinsic sources of quantum noise in molecules. Conical intersections between two periodic potentials form CTs in electron paramagnetic resonance experiments of the spin-polarized singlet fission photoproduct. We report on a pair of CTs for a two-chromophore molecule in terms of the Zeeman field strength, molecular orientation relative to the field, and molecular geometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical frequency reference for the national time scale

Incorporation of a strontium optical clock as an optical frequency reference into the primary standard GET 1-2018 is experimentally implemented. A new model is proposed to define a local atomic time scale using an optical reference incorporated into a complex for reproducing primary standard units. Preliminary results of comparing the frequencies of the optical reference and the hydrogen maser entering the composition of primary time and frequency standards are presented. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical pumping of ultracold thulium atoms to a lower level of the clock transition and study of their depolarisation

The atomic energy levels corresponding to states with the zero projection of the total angular momentum have a weak sensitivity to certain sources of shifts and, therefore, are widely used in precision spectroscopy. The optical pumping of ultracold thulium atoms to the ground state level with the zero projection of the total angular momentum is described. The population dynamics of this state due to magnetic dipole − dipole interaction in an external magnetic field is studied. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Absolute Frequency Measurement of the {sup 40}Ca{sup +} 4s {sup 2}S{sub 1/2}-3d {sup 2}D{sub 5/2} Clock Transition

We report on the first absolute transition frequency measurement at the 10{sup -15} level with a single, laser-cooled {sup 40}Ca{sup +} ion in a linear Paul trap. For this measurement, a frequency comb is referenced to the transportable Cs atomic fountain clock of LNE-SYRTE and is used to measure the {sup 40}Ca{sup +} 4s {sup 2}S{sub 1/2}-3d {sup 2}D{sub 5/2} electric-quadrupole transition frequency. After the correction of systematic shifts, the clock transition frequency {nu}{sub Ca{sup +}}=411 042 129 776 393.2(1.0) Hz is obtained, which corresponds to a fractional uncertainty within a factor of 3 of the Cs standard. In addition, we determine the Landeg factor of the 3d{sup 2}D{sub 5/2} level to be g{sub 5/2}=1.200 334 0(3)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Entangling the lattice clock: Towards Heisenberg-limited timekeeping

A scheme is presented for entangling the atoms of an optical lattice to reduce the quantum projection noise of a clock measurement. The divalent clock atoms are held in a lattice at a 'magic' wavelength that does not perturb the clock frequency - to maintain clock accuracy - while an open-shell J=1/2 'head' atom is coherently transported between lattice sites via the lattice polarization. This polarization-dependent 'Archimedes' screw' transport at magic wavelength takes advantage of the vanishing vector polarizability of the scalar, J=0, clock states of bosonic isotopes of divalent atoms. The on-site interactions between the clock atoms and the head atom are used to engineer entanglement and for clock readout.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of the systematic shifts of a single-{sup 40}Ca{sup +}-ion frequency standard

Progress on the evaluation of systematic frequency shifts is described in the development of the optical frequency standard based on single-trapped {sup 40}Ca{sup +} with a ''clock'' transition at 729 nm. The overall systematic uncertainty of the 4s {sup 2} S{sub 1/2}-3d {sup 2} D{sub 5/2} clock resonance has been characterized to be 7.8 x 10{sup -16}. This uncertainty is at a level similar to the Cs fountain primary standard, while the potential stability for the {sup 40}Ca{sup +} clock exceeds that of Cs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lattice-Induced Frequency Shifts in Sr Optical Lattice Clocks at the 10{sup -17} Level

We present a comprehensive study of the frequency shifts associated with the lattice potential in a Sr lattice clock by comparing two such clocks with a frequency stability reaching 5x10{sup -17} after a 1 h integration time. We put the first experimental upper bound on the multipolar M1 and E2 interactions, significantly smaller than the recently predicted theoretical upper limit, and give a 30-fold improved upper limit on the effect of hyperpolarizability. Finally, we report on the first observation of the vector and tensor shifts in a Sr lattice clock. Combining these measurements, we show that all known lattice related perturbations will not affect the clock accuracy down to the 10{sup -17} level, even for lattices as deep as 150 recoil energies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Frequency standards based on ultracold atoms in tests of general relativity, navigation and gravimetry

Research and development in the field of optical clocks based on ultracold atoms and ions have enabled the relative uncertainty in frequency to be reduced down to a few parts in 10{sup 18}. The use of novel, precise frequency comparison methods opens up new possibilities for basic research (sensitive tests of general relativity, a search for a drift of fundamental constants and a search for ‘dark matter’) as well as for state-of-the-art navigation and gravimetry. We discuss the key methods that are used in creating precision clocks (including transportable clocks) based on ultracold atoms and ions and the feasibility of using them in resolving current relativistic gravimetry issues. (paper)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗