Si/IrSi3 Schottky-Barrier Infrared Detectors

Si/IrSi or Si/IrSi3 Schottky-barrier detector fabricated by stoichiometric codeposition of Ir and Si on p Si substrate. Includes p+ substrate contact, silicide electrode, and n Si guard ring, which suppresses leakage around periphery of silicide electrode. Part of continuing effort to develop imaging arrays of Schottky-barrier detectors operating at far-infrared wavelengths.

Lin, True-Lon↗

Advanced Ge detectors for gamma-ray astronomy

Externally segmented coaxial detectors are fabricated for high efficiency in detecting gamma rays from cosmic sources with good sensitivities. The external background is reduced by enclosing the Ge detector array inside a thick active shield. The outer electrode of the coaxial detectors is subdivided into five segments, and internal beta activity is rejected by operating the segmented detector in a multisegment mode. The multisegment mode requires that events be detected in two or more segments before they are recorded. The full-energy-peak (FEP) efficiency of the unit is tested as a function of the incident gamma-ray energy and of the discriminator threshold of the segments. Measurements of beta-rejection and FEP efficiency are compared with Monte Carlo calculations, and good agreement is noted.

Varnell, Larry S.↗

Plasma Enhanced Growth of Carbon Nanotubes For Ultrasensitive Biosensors

The multitude of considerations facing nanostructure growth and integration lends itself to combinatorial optimization approaches. Rapid optimization becomes even more important with wafer-scale growth and integration processes. Here we discuss methodology for developing plasma enhanced CVD growth techniques for achieving individual, vertically aligned carbon nanostructures that show excellent properties as ultrasensitive electrodes for nucleic acid detection. We utilize high throughput strategies for optimizing the upstream and downstream processing and integration of carbon nanotube electrodes as functional elements in various device types. An overview of ultrasensitive carbon nanotube based sensor arrays for electrochemical bio-sensing applications and the high throughput methodology utilized to combine novel electrode technology with conventional MEMS processing will be presented.

Cassell, Alan M.↗

Microshutter Arrays for the NGST NIRSpec

We are developing a programmable multiobject field selector for the NGST NIRSpec. This device is a microshutter array, a close-packed 2000 x 2000 array of 100 micrometer x 100 micrometer shutters fabricated with Micro-ElectroMechanical Systems (MEMS) technologies. The shutters are opened using a magnet scanned over the array. The shutters are held open by electrostatic potentials on adjacent vertical electrodes. Modeling of the magnetic actuation of the microshutters allowed optimization of the magnetic field configuration, the distance between magnet and shutters, and the force and torque produced by the magnet. The results of laboratory tests are consistent with our modeling. We have demonstrated actuation, latching and addressing. We are able to rotate shutters out of the plane up to 90 degree and more, to latch them electrostatically to the walls and release them selectively. During the last six month all critical elements of the array have been demonstrated. Fabrication processes were developed to deposit vertical electrodes on support grid side walls and insulated light-shields that block the gaps between shutters and the support grid. Physical optics analysis was performed to assess the expected optical performance of the microshutters. A preliminary Fourier optics analysis on the microshutter array performance has been carried out. More detailed analysis of wave propagation through 3D structures is a next step. An optical test station for verifying optical parameters of the shutter array at room temperature has been developed. It allows to measure parameters, such as transmission, scattering, contrast ratio, and diffraction of the array structure. Initial data have been acquired and are being analyzed and compared to theoretical predictions.

Moseley, Harvey↗

Fully‐Printed Ion Sensor Arrays for Measuring Agricultural Nitrogen and Potassium Concentrations Using Nernstian and AI Models

Abstract The chemical composition of growing media is a key factor for plant growth, impacting agricultural yield and sustainability. However, there is a lack of affordable chemical sensors for ubiquitous nutrient ion monitoring in agricultural applications. This work investigates using fully printed ion‐sensor arrays to measure the concentrations of nitrate, ammonium, and potassium in mixed‐electrolyte media. Ion sensor arrays composed of nitrate, ammonium, and potassium ion‐selective electrodes and a printed silver‐silver chloride (Ag/AgCl) reference electrode are fabricated and characterized in aqueous solutions in a range of concentrations that encompass what is typical for agricultural growing media (0.01 m m –1 m ). The sensors are also tested in mixed‐electrolyte solutions of NaNO 3 , NH 4 Cl, and KCl of varying concentrations, and the recorded potentials are input into Nernstian and artificial neural network models to compare the prediction accuracy of the models against ground truth. The artificial neural network models demonstrated higher accuracy over the Nernstian model, and the model using only ion‐sensor inputs is 7.5% more accurate than the Nernstian model under the same conditions. By enabling more precise and efficient fertilizer application, these sensor arrays coupled to computational models can help increase crop yields, optimize resource use, and reduce environmental impact.

Goodrich, Payton [University of California Berkele↗

An Investigation of Ionic Wind Propulsion

A corona discharge device generates an ionic wind and thrust, when a high voltage corona discharge is struck between sharply pointed electrodes and larger radius ground electrodes. The objective of this study was to examine whether this thrust could be scaled to values of interest for aircraft propulsion. An initial experiment showed that the thrust observed did equal the thrust of the ionic wind. Different types of high voltage electrodes were tried, including wires, knife-edges, and arrays of pins. A pin array was found to be optimum. Parametric experiments, and theory, showed that the thrust per unit power could be raised from early values of 5 N/kW to values approaching 50 N/kW, but only by lowering the thrust produced, and raising the voltage applied. In addition to using DC voltage, pulsed excitation, with and without a DC bias, was examined. The results were inconclusive as to whether this was advantageous. It was concluded that the use of a corona discharge for aircraft propulsion did not seem very practical.

Wilson, Jack↗

Continuous antenna arrays

A continuous antenna array includes a plurality of antenna elements whose opposing electrodes create an electric field that excites polarization currents in an enclosed dielectric. Each of the antenna elements comprises one or more stripline feeds configured to provide a flat form factor and apply a signal with controlled phase differences between the plurality of antenna elements.

Krawczyk, Frank L.↗

Direct current microplasma formation around microstructure arrays

We demonstrate the formation and transition behaviors of a microplasma around microstructure arrays at different gas pressures via two-dimensional particle-in-cell/Monte Carlo collision simulations. It is found that the microdischarge occurs outside the cathode microcavities at the lowest pressure and starts penetrating the microcavities with a curved sheath edge as the pressure increases. At higher pressure, coupled periodic microhollow cathode discharges (MHCDs) are formed inside the microcavities. Further increasing the gas pressure results in the disappearance of the MHCDs, and the dominant discharge shifts outside of the microcavity, locating above the protrusion tips. The effect of the space charge shielding on the discharge and the conditions for MHCD formation are discussed. The macroscopic discharge parameter scalings with the gas pressure and the electron kinetics are also examined. The results are helpful for deeply understanding the microplasma formation with nonplanar electrodes, which inform the scaling, design, and optimization of microplasma array devices across a wide range of pressure regimes in practical applications.

42 ENGINEERING↗

Si Microwire-Array Photocathodes Decorated with Cu Allow CO 2 Reduction with Minimal Parasitic Absorption of Sunlight

High loadings of Cu were integrated on the light-facing side of Si microwire arrays used under simulated sunlight for the photoelectrochemical reduction of CO 2 (aq) to hydrocarbons in 0.10 M KHCO 3 (aq). Radial-junction n + p-Si microwire arrays decorated with Cu exhibited absolute photocurrent densities comparable to an uncovered Si surface. Moreover, with respect to a Cu foil electrode, the positive shift in the onset potential for hydrocarbon formation at n + p-Si/Cu microwire arrays was equal to or greater than the photovoltage of the semiconductor alone. Selective electrodeposition of Cu on the tips and sidewalls of Si microwires was responsible for the minimal parasitic reflection and absorption exhibited by the catalyst, such that light-limited, absolute current densities >25 mA·cm –2 were sustained for 48 h under simulated sunlight. Photoelectrodes prepared from semiconductors with low diode quality factors and electrocatalysts with large Tafel slopes are shown to benefit from increased microstructured surface area. Si microwire arrays are thus suitable for photoelectrochemical reactions requiring high loadings of metallic and reflective electrocatalysts.

25 ENERGY STORAGE↗

The Sensitivity of Nickel Substitution in the Structural Design of Manganese-Based Layered and Lithiated Spinel Electrodes for Li-Ion Batteries

A concerted effort is being made at Argonne National Laboratory to explore and develop high-performance lithium-manganese-nickel-oxide cathode materials for the lithium battery industry. They are both energy- and cost-competitive relative to cobalt- and nickel-rich systems, such as LiCoO 2 , LiNi 0.8 Co 0.15 Al 0.05 O 2 , and LiNi 0.8 Mn 0.1 Co 0.1 O 2 . The recent discovery of the structural versatility of LiNi 0.5 Mn 0.5 O 2 , has revealed that it can exist in three configurations: lithiated spinel, partially disordered layered, and completely disordered rock salt within a common cubic-close-packed oxygen array. This versatility opens up the possibility of designing structurally integrated electrode components with interlinking 2-D (layered) and 3-D (spinel) channels for Li-ion transport. This paper highlights the sensitivity of Ni substitution and synthesis temperature on the structural and electrochemical properties of LiNi 0.50 Mn 0.50 O 2 , LiNi 0.53 Mn 0.47 O 2 , LiNi 0.47 Mn 0.53 O 2 , and LiNi 0.25 Mn 0.75 O 2 electrodes, as well as a cobalt-containing composition, LiNi 0.333 Mn 0.333 Co 0.333 O 2 , when synthesized at a relatively low temperature of 400 °C.

25 ENERGY STORAGE↗

Advanced Frost Sensor for HVAC Applications

Frost is a common problem in heating, ventilation, and air conditioning (HVAC) systems that can degrade their efficiencies, leading to excessive electricity consumption. Appropriate defrosting is therefore essential for heat pumps and refrigeration systems. However, these systems typically run the defrost cycle based on a predetermined time interval, a method that does not accurately identify the amount of frost and thus consume excessive electricity. To substantially improve defrosting initiation and termination, this paper describes development of a smart sensor based on a capacitive sensing technique that can quantify frost accumulation and difference between frost, ice, and water. The reported sensor adopts interdigitated comb electrodes and can be updated to a potential multifunctional sensor array for the enhancing identification of frost, ice, and water with the integrated measurement of surface temperature, frost capacitance, and resistance. The proposed frost sensor is potentially expected to have widespread applications in HVAC systems, including heat pumps, refrigerators, and commercial refrigeration systems.

Gao, Zhiming↗

Ultra-Low-Temperature Homoepitaxial Growth of Sb-Doped Silicon

An ultra-low-temperature process for homoepitaxial growth of high-quality, surface-confined, Sb-doped silicon layers is presented. Non-equilibrium growth by molecular beam epitaxy (MBE) is used to achieve dopant incorporation in excess of 2x10(exp 14) per sq cm in a thin, surface-confined layer. Sb surface segregation larger than expected from theoretical models was observed, in agreement with other experimental works. Furthermore, this work details an entirely low-temperature process (less than 450 degree C) that can be applied to fully processed and aluminum-metallized silicon devices. One application of this process is the formation of a back-surface electrode for back-illuminated high-purity silicon imaging arrays.

Molecular beam epitaxy↗

Electronic Tongue Containing Redox and Conductivity Sensors

The Electronic Tongue (E-tongue 2) is an assembly of sensors for measuring concentrations of metal ions and possibly other contaminants in water. Potential uses for electronic tongues include monitoring the chemical quality of water in a variety of natural, industrial, and laboratory settings, and detecting micro-organisms indirectly by measuring microbially influenced corrosion. The device includes a heater, a temperature sensor, an oxidation/reduction (redox) sensor pair, an electrical sensor, an array of eight galvanic cells, and eight ion-specific electrodes.

Buehler, Martin↗

High-velocity, multistage, nozzled, ion driven wind generator and method of operation of the same adaptable to mesoscale realization

Gas flows of modest velocities are generated when an organized ion flux in an electric field initiates an ion-driven wind of neutral molecules. When a needle in ambient air is electrically charged to a potential sufficient to produce a corona discharge near its tip, such a gas flow can be utilized downstream of a ring-shaped or other permeable earthed electrode. In view of the potential practical applications of such devices, as they represent blowers with no moving parts, a methodology for increasing their flow velocities includes exploitation of the divergence of electric field lines, avoidance of regions of high curvature on the second electrode, control of atmospheric humidity, and the use of linear arrays of stages, terminating in a converging nozzle. The design becomes particularly advantageous when implemented in mesoscale domains.

Dunn-Rankin, Derek↗

Electrical sensing, tracking, and actuation of droplets

Devices, techniques, and processes are disclosed that use electrical impedance to detect of the presence and contents of droplets including cells, nucleic acids, proteins, or solute concentrations in an array of retrievable, trackable, trapped droplets in a fluidic system. Electrodes may be positioned underneath individual droplet traps in a microchannel to assay droplet contents and/or actuating droplets for the release of the droplets from corresponding traps. The disclosed technology may be used for detection of the results of solvent extraction processes including time-dependent quantification of metal ion concentration in the aqueous and organic phases, for wastewater treatment, heavy metal detection, pharmaceutical industry, and/or biotechnology, or for environmental monitoring of wastewater for toxic metal, monitoring of biological cell viability and proliferation, monitoring of extraction processes used in heavy metal mining, monitoring of extraction processes used in nuclear fuel processing, monitoring kinetics of enzyme processes, and/or assessing pharmacodynamics and drug efficacy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microelectrode Arrays for Electrochemical Cycling of Individual Battery Particles

The electrochemical characterization of battery materials is usually performed on porous electrodes containing conductive additives, binders, and ensembles of redox-active particles at densities as high as 10 15 cm –3 . These complex structures often obscure individual battery particles’ intrinsic properties, hindering insights into the fundamentals of battery electrochemistry. To address this challenge, we developed microelectrode arrays to enable the charge and discharge of individual battery particles in liquid electrolytes. In this Methods and Protocols paper, we describe the fabrication of the microelectrode array chips, the assembly of particles onto microelectrodes, and the different types of electrochemical techniques that can be used, including galvanostatic cycling, cyclic voltammetry, potentiostatic intermittent titration, and electrochemical impedance spectroscopy. We use micron-sized lithium cobalt oxide as a model system to showcase the reliability and versatility of single-particle electrochemical experiments enabled by our microelectrode array. In conclusion, we aim to provide a detailed description to promote future uses of microelectrode arrays in fundamental research of batteries and other electrochemical systems.

25 ENERGY STORAGE↗

Amplified Thermionic Cooling Using Arrays of Nanowires

A class of proposed thermionic cooling devices would incorporate precise arrays of metal nanowires as electron emitters. The proposed devices could be highly miniaturized, enabling removal of heat from locations, very close to electronic devices, that have previously been inaccessible for heat-removal purposes. The resulting enhancement of removal of heat would enable operation of the devices at higher power levels and higher clock speeds. Moreover, the mass, complexity, and bulk of electronic circuitry incorporating these highly miniaturized cooling devices could be considerably reduced, relative to otherwise equivalent circuitry cooled by conventional electromechanical, thermoelectric, and fluidic means. In thermionic cooling, one exploits the fact that because only the highest-energy electrons are thermionically emitted, collecting those electrons to prevent their return to the emitting electrode results in the net removal of heat from that electrode. Collection is effected by applying an appropriate positive bias potential to another electrode placed near the emitting electrode. The concept underlying the proposal is that the thermionic-emission current and, hence, the cooling effect attainable by use of an array of nanowires could be significantly greater than that attainable by use of a single emitting electrode or other electron- emitting surface. The wires in an array according to the proposal would protrude perpendicularly from a planar surface and their heights would be made uniform to within a sub-nanometer level of precision

Yang, Eui-Hyeok↗

Time delay and integration array (TDI) using charge transfer device technology. Phase 2, volume 1: Technical

The 20x9 TDI array was developed to meet the LANDSAT Thematic Mapper Requirements. This array is based upon a self-aligned, transparent gate, buried channel process. The process features: (1) buried channel, four phase, overlapping gate CCD's for high transfer efficiency without fat zero; (2) self-aligned transistors to minimize clock feedthrough and parasitic capacitance; and (3) transparent tin oxide electrode for high quantum efficiency with front surface irradiation. The requirements placed on the array and the performance achieved are summarized. This data is the result of flat field measurements only, no imaging or dynamic target measurements were made during this program. Measurements were performed with two different test stands. The bench test equipment fabricated for this program operated at the 8 micro sec line time and employed simple sampling of the gated MOSFET output video signal. The second stand employed Correlated Doubled Sampling (CDS) and operated at 79.2 micro sec line time.