Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “analytical detection method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Separation and determination of ultratrace rhenium quantities in molybdenum matrix

The production of very pure molybdenum, free of Re even at ultratrace levels, is extremely important in meeting target purity specifications during the production of 99 Mo for medical applications. Here we propose two methods for separating ultratrace levels of Re from a bulk Mo matrix using either solvent extraction or extraction chromatography, combined with inductively coupled plasma quadrupole mass spectrometry (ICP-MS) detection. Re is extracted (D > 70) from solutions in sulfuric acid as a complex with tri-n-butyl phosphate. Scrubbing and washing steps result in total decontamination factors for Mo up to 1,700 for solvent extraction and 3,500 for extraction chromatography. Re is stripped into a 3 M NH 4 OH matrix and analyzed by ICP-MS. Detection (L D ) and quantification (L Q ) limits were optimized by matrix-matching to allow detection of Re in strip solutions at levels of L D = 0.1 ng Re/g-Mo and L Q = 0.3 ng Re/g-Mo in Mo powder samples. By employing these two extraction methods, excellent recoveries of Re from bulk Mo are achieved, and the L Q is improved by a factor of 5 x 10 4 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advancements of On-Line Monitoring and Real-Time Characterization of Actual Low-Level Hanford Tank-Waste Samples

Waste and process stream characterization is essential to the safe, efficient, and cost-effective processing of Hanford Site materials. The demand for materials characterization including chemical, radionuclide, and physical attributes during waste management, transfer, and staging operations in the Hanford tank farms is expected to significantly increase as the U.S. Department of Energy River Protection Project progresses toward Hanford waste treatment and immobilization. Our past work has applied Raman on-line monitoring and chemometric modeling to the supernate of Hanford tank 241-AP-105 and has demonstrated the quantitative measurement of nine analytes within this waste. To demonstrate broader applicability, this method has now been expanded to waste from two additional Hanford tanks, AW-102 and AP-107, and the offgas condensate from lab-scale melter runs of actual-tank waste feeds. To enhance the performance of the Raman method, instruments with various excitation wavelengths were compared, since it is known that the Raman response is enhanced by shorter wavelength excitation. The laser excitations for the three systems tested were 404 nm, 532 nm, and 671 nm. In addition to laser wavelength selection, the laser power, measurement integration times, and signal averaging techniques were also investigated to determine their effect on detection limits for oxy-anion analytes within tank wastes. These advancements in Raman capability are compared with past standards and will be presented.

Bryan, Samuel A.↗

Direct analysis of cotton swipes for uranium and plutonium isotopic determination by microextraction-ICP-MS

The determination of uranium and plutonium isotopic abundance on environmental samples collected by International Atomic Energy Agency (IAEA) inspectors is vital for the detection of undeclared nuclear activities and material under the international nuclear safeguards regime. Current analytical protocols require time-consuming sample preparation steps prior to subsequent measurement by inorganic mass spectrometry (MS). Recent efforts from this laboratory have focused on developing sample preparation methods for faster analysis, potentially allowing higher sample throughput[1]. Alternative methods including microextraction sampling in conjunction with inductively coupled plasma-mass spectrometry (ICP-MS) have been recently explored. This methodology, microextraction-ICP-MS, was developed such that uranium and plutonium could be extracted from the swipe surface and directed into the ICP-MS for an in-situ measurement, eliminating the need for swipe ashing and digestion. A commercial off-the-shelf microextraction system was customized with an automated movable XY stage that can be programmed to save sampling locations, allowing for automated rapid sampling of swipe surfaces. Additional efforts have focused on the utilization of collision cell technology to the microextraction ICP-MS method. This would eliminate the need for lengthy column chemistry procedures to purify separated uranium and plutonium fractions before analysis. Here, the extracted U/Pu analyte is measured by reacting the uranium ions with CO2 in the collision cell of an ICP-MS, shifting the uranium to UO+, which will not interfere with the plutonium isotopic determination. The developed method utilizing collision cell – ICP-MS technology has demonstrated the ability to measure plutonium isotope ratios in the presence of high uranium concentration on the transient signal from the microextraction system utilizing certified reference materials from JRC-Geel and the New Brunswick Laboratory Program Office.

Bradley, Veronica↗

Data for Selected Ion Monitoring for Orbitrap-Based Metabolomics

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage.f

Mass Spectrometry↗

A Semi-Analytical Approach for State-Space Electromagnetic Transient Simulation

Here, this paper proposes a semi-analytical approach for efficient and accurate electromagnetic transient (EMT) simulation of a power grid. The approach first derives a high-order semi-analytical solution (SAS) of the grid’s state-space EMT model using the differential transformation (DT), and then evaluates the solution over enlarged, variable time steps to significantly accelerate the simulations while maintaining its high accuracy on detailed fast EMT dynamics. The approach also addresses switches during large time steps by using a limit violation detection algorithm with a binary search-enhanced quadratic interpolation. Case studies are conducted on EMT models of the IEEE 39-bus system and large-scale systems to demonstrate the merits of the new simulation approach against traditional numerical methods.

electromagnetic transient↗

Review of multi-faceted morphologic signatures of actinide process materials for nuclear forensic science

Particle morphology is an emerging signature that has the potential to identify the processing history of unknown nuclear materials. Using readily available scanning electron microscopes (SEM), the morphology of nearly any solid material can be measured within hours. Coupled with robust image analysis and classification methods, the morphological features can be quantified and support identification of the processing history of unknown nuclear materials. The viability of this signature depends on developing databases of morphological features, coupled with a rapid data analysis and accurate classification process. With developed reference methods, datasets, and throughputs, morphological analysis can be applied within days to (i) interdicted bulk nuclear materials (gram to kilogram quantities), and (ii) trace amounts of nuclear materials detected on swipes or environmental samples. In conclusion, this review aims to develop validated and verified analytical strategies for morphological analysis relevant to nuclear forensics.

36 MATERIALS SCIENCE↗

Accelerating Random Forest Classification on GPU and FPGA

Random Forests (RFs) are a commonly used machine learning method for classification and regression tasks spanning a variety of application domains, including bioinformatics, business analytics, and software optimization. While prior work has focused primarily on improving performance of the training of RFs, many applications, such as malware identification, cancer prediction, and banking fraud detection, require fast RF classification. In this work, we accelerate RF classification on GPU and FPGA. In order to provide efficient support for large datasets, we propose a hierarchical memory layout suitable to the GPU/FPGA memory hierarchy. We design three RF classification code variants based on that layout, and we investigate GPU- and FPGA-specific considerations for these kernels. Our experimental evaluation, performed on an Nvidia Xp GPU and on a Xilinx Alveo U250 FPGA accelerator card using publicly available datasets on the scale of millions of samples and tens of features, covers various aspects. First, we evaluate the performance benefits of our hierarchical data structure over the standard compressed sparse row (CSR) format. Second, we compare our GPU implementation with cuML, a machine learning library targeting Nvidia GPUs. Third, we explore the performance/accuracy tradeoff resulting from the use of different tree depths in the RF. Finally, we perform a comparative performance analysis of our GPU and FPGA implementations. Our evaluation shows that for high accuracy targets, our GPU implementation yields 5-9x speedup over CSR, and up to a 2x speedup over cuML.

FPGA, Xilinx FPGA, GPU, Random Forest classificati↗

Beyond Contrast Transfer: Spectral SNR as a Finite-Dose Metric for STEM Phase Retrieval

The contrast transfer function (CTF) is widely used to evaluate phase retrieval methods in scanning transmission electron microscopy (STEM), including center-of-mass imaging, parallax imaging, direct ptychography, and iterative ptychography. However, the CTF reflects only the maximum usable signal, neglecting the effects of finite electron fluence and the Poisson-limited nature of detection. As a result, it can significantly overestimate practical performance, especially in low-dose regimes. Here, we employ the spectral signal-to-noise ratio (SSNR), as a finite-dose statistical framework to evaluate the recoverable signal as a function of spatial frequency. Using numerical reconstructions of white-noise objects, we show that center-of-mass, parallax, and direct ptychography exhibit dose-independent SSNRs, with close-form analytic expressions. In contrast, iterative ptychography exhibits a surprising dose dependence: at low fluence, its SSNR converges to that of direct ptychography; at high fluence, it saturates at a value consistent with the maximum detective quantum efficiency predicted by recent quantum Fisher information bounds. The results highlight the limitations of CTF-based evaluation and motivate SSNR as a more accurate, finite-dose metric for assessing STEM phase retrieval methods.

STEM phase retrieval↗

Determination of impurities in cubic boron nitride (cBN) by inductively coupled plasma mass spectrometry (ICPMS)

The phase stability of cBN is critically dependent on the content and amount of impurities present. While studies have shown qualitatively that the addition of certain impurities can either increase or decrease the cBN-hBN phase transition temperature, studies have yet to show this effect quantitatively. This is because analytical methods to characterize minor and trace impurities in cBN are currently lacking. To this end, we present flux fusion methods capable of fully digesting cBN samples for ICPMS analyses. The materials used in this study are commercially available cBN powders in three different sizes. Two types of fluxes (LiOH and NaOH·H 2 O) are utilized so that both Li and Na impurities can be determined. To ensure the accuracy of Si measurements, a column chromatography method has been developed to purify Si from flux materials in order to increase the amount of dissolved sample sent to the ICP. Detection limits have been determined using procedural blanks and are found to be below 20 μg/g for all 58 elements analyzed except for Si, for which the detection limit is 312 μg/g. Nonetheless, all cBN powders studied are found to have high Si impurity levels that are above detection limit. This study provides a much-needed analytical protocol to enable comprehensive screening of impurities in cBN.

36 MATERIALS SCIENCE↗

Evaluation of phenolic antioxidant capacity in beverages based on laccase immobilized on screen-printed carbon electrode modified with graphene nanoplatelets and gold nanoparticles

A simple and highly sensitive electrochemical biosensor based on laccase immobilized onto a gold nanoparticles/graphene nanoplatelets-modified screen-printed carbon electrode (LACC/AuNP/GNPl/SPCE) was developed for the determination of hydroquinone (HQ) and other phenolic compounds. The biosensor shows excellent electro-catalytic activity towards oxidation of hydroquinone at a potential of -0.05 V (vs Ag/AgCl, 3 M KCl) in phosphate buffer as supporting electrolyte (0.1 M, pH 7.0) using hydrodynamic amperometry. Analytical characteristics uncover that the LACC/AuNP/GNPl/SPCE comprises a wide linear range for the dependence of the signal on HQ concentrations from 4 to 130 µM with a detection limit (3σ) of 1.5 µM. The repeatability (5 measurements, 100 µM hydroquinone) is ±2% and the reproducibility (5 biosensors, 100 µM hydroquinone) is ±3%. Interference studies of most common compounds with the determination of hydroquinone demonstrated negligible effects. Finally, the biosensor and the analytical method were applied to the determination of phenolic antioxidant capacity (AOC) in wine and blueberry syrup based on Trolox (6‑hydroxy‑2,5,7,8-tetramethylchromane-2-carboxylic acid) and hydroquinone equivalents. The results were evaluated by using their calibration curves which were satisfactory and agreed well with the results obtained by the reference method Trolox Equivalent Antioxidant Capacity assay (TEAC-Assay).

60 APPLIED LIFE SCIENCES↗

Functionalized Polymer Thin Films for Plutonium Capture and Isotopic Screening from Aqueous Sources

The rapid screening of plutonium from aqueous sources remains a critical challenge for nuclear nonproliferation efforts. The determination of trace-level Pu isotopes in water requires offsite sample preparation and analysis; therefore, new methods that combine plutonium purification, concentration, and isotopic screening in a fieldable detection system will provide an invaluable tool for nuclear safeguards. This contribution describes the development and characterization of thin polymer-ligand films for the isolation and concentration of waterborne Pu for direct spectroscopic analyses. Submicron thin films were prepared through spin coating onto Si wafers and consisted of combinations of polystyrene (PS) with dibenzoylmethane, thenoyltrifluoroacetone, and di(2-ethylhexyl)phosphoric acid (HDEHP). Pu uptake studies from solutions at pH from 2.3 to 6.3 indicated that only films containing HDEHP exhibited significant recovery of Pu. High alpha spectroscopy peak energy resolutions were achieved for PS-HDEHP films over a range of film thicknesses from 30 to 250 nm. Furthermore, a separate study was performed to evaluate uptake from a primarily Pu(V) solution where it was observed that doubling the HDEHP loading in the film increased uptake of Pu by an order of magnitude. X-ray photoelectron spectroscopy (XPS) analysis revealed that HDEHP was highly concentrated within the first few nanometers of the film at the higher loading. XPS analysis also revealed that, in the presence of water, HDEHP was stripped from the surface layer of the film at circumneutral pH. While significant losses of ligand were seen in all samples, higher loadings of HDEHP resulted in measurable amounts of ligand retained after a 12-h soak in water. Findings of this study are being used to guide the development of thin-film composite membrane-based detection methods for the rapid, fieldable analysis of Pu in water.

36 MATERIALS SCIENCE↗

Real-Time Fault Location Using the Retardation Method

A new method for short-circuit fault location is proposed. The method is based on instantaneous signal measurement and its first and second derivatives, which are the novel elements of the current approach. The derivatives allow associating a precise time stamp to the occurrence of the fault. Due to retardation phenomena, the difference between the times in which a signal is registered in two detectors can be used to locate the fault. We offer several mathematical models to describe the fault. Although a description of faults in terms of a lumped circuit is useful for elucidating the methods for detecting the fault, this description will not suffice to describe the fault signal propagation; hence, a distributed models is needed, which is given in terms of the telegraph equations. Those equations were used to derive a transmission line transfer function, and an exact analytical description of the fault signal propagating in the transmission line was obtained. The analytical solution was verified both by numerical simulations and experimentally.

42 ENGINEERING↗

Spatially quasi-periodic bifurcations from periodic traveling water waves and a method for detecting bifurcations using signed singular values

We present a method of detecting bifurcations by locating zeros of a signed version of the smallest singular value of the Jacobian. This enables the use of quadratically convergent root-bracketing techniques or Chebyshev interpolation to locate bifurcation points. Only positive singular values have to be computed, though the method relies on the existence of an analytic or smooth singular value decomposition (SVD). The sign of the determinant of the Jacobian, computed as part of the bidiagonal reduction in the SVD algorithm, eliminates slope discontinuities at the zeros of the smallest singular value. We use the method to search for spatially quasi-periodic traveling water waves that bifurcate from large-amplitude periodic waves. The water wave equations are formulated in a conformal mapping framework to facilitate the computation of the quasi-periodic Dirichlet-Neumann operator. We find examples of pure gravity waves with zero surface tension and overhanging gravity-capillary waves. In both cases, the waves have two spatial quasi-periods whose ratio is irrational. We follow the secondary branches via numerical continuation beyond the realm of linearization about solutions on the primary branch to obtain traveling water waves that extend over the real line with no two crests or troughs of exactly the same shape. The pure gravity wave problem is of relevance to ocean waves, where capillary effects can be neglected. Such waves can only exist through secondary bifurcation as they do not persist to zero amplitude. The gravity-capillary wave problem demonstrates the effectiveness of using the signed smallest singular value as a test function for multi-parameter bifurcation problems. This test function becomes mesh independent once the mesh is fine enough.

97 MATHEMATICS AND COMPUTING↗

Streaming Analytics for Anomaly Detection in Large-Scale Data

Anomalous behavior poses serious risks to assured performance and reliability of complex, high-consequence systems. For spaceborne assets and their state-of-health (SOH) telemetry, the challenges of high-dimensional data of varying data types are compounded by computational limitations from size, weight, and power (SWaP) constraints as well as data availability. Automated anomaly detection methods tend to perform poorly under these constraints, while current operational approaches can introduce delays in response time due to the manual, retrospective processes for understanding system failures. As a result, presently deployed space systems, and those deployed in the near future, face situations where mission operations might be delayed or only be able to operate under degraded capabilities. Here, we examine a near-term lightweight solution that provides real-time detection capabilities for rare events and assess state-of-the-art anomaly detection techniques against real SOH telemetry from space platforms. This report describes our methodology and research, which could support more automated capabilities for comprehensive space operations as well as for other resource-constrained edge applications.

97 MATHEMATICS AND COMPUTING↗

Electrochemical detection of gas phase chemicals

We provide an electrochemical sensor in which working microelectrodes are arranged in an array and interconnected in parallel. The working electrodes are arranged so that in use, they are electrochemically coupled to a counter electrode structure through an electrolyte. The sensor also includes a microporous body arranged so that in use, it is situated at a boundary between a gaseous environment and the electrolyte. In another aspect, we provide a method of sensing in which a sample of gas is admitted to a liquid electrolyte maintained by pores of a porous substrate. A voltage is applied to the liquid electrolyte, and an electrical response to the applied voltage is observed, thereby to detect electrochemical evidence of an analyte within the liquid electrolyte.

Klavetter, Kyle C.↗

Use of Rig Parameter Data in Bit Constraint Models for Improved Drilling Performance at The Geysers

Surface parameter measurements are routinely used during deep well construction to monitor and guide drilling conditions for improved performance and reduced costs. However, these measurements are of reduced value without a standard to aid in evaluation and decision making. A method is demonstrated whereby drill bit constraint models are used to interpret drilling response parameters. Drill rig parameter data for well GDC-36 at the Geysers Geothermal Field Power were acquired by Geysers Power Company and drilling contractor Kenai Drilling using Pason US DataHub and evaluated. Drilling parameters are evaluated using laboratory-validated rock reduction models for predicting the phenomenological response of drag bits (Detournay and Defourny, 1992) along with other model constraints in computational algorithms. The method is used to evaluate overall bit performance, monitor bit integrity, and detect the presence of drillstring vibrations and other conditions contributing to bit failure; comparisons are made to observations of bit wear and damage. The method will be applied in real-time to improve decision-making on subsequent wells and has applicability to development of advanced analytics on future geothermal wells using real-time electronic drilling recorder (EDR) data for improved performance and reduced drilling costs.

15 GEOTHERMAL ENERGY↗

Analytical capabilities for iodine detection: Review of possibilities for different applications

This Review summarizes a range of analytical techniques that can be used to detect, quantify, and/or distinguish between isotopes of iodine (e.g., long-lived 129 I, short-lived 131 I, stable 127 I). One reason this is of interest is that understanding potential radioiodine release from nuclear processes is crucial to prevent environmental contamination and to protect human health as it can incorporate into the thyroid leading to cancer. It is also of interest for evaluating iodine retention performances of next-generation iodine off-gas capture materials and long-term waste forms for immobilizing radioiodine for disposal in geologic repositories. Depending upon the form of iodine (e.g., molecules, elemental, and ionic) and the matter state (i.e., solid, liquid, and gaseous), the available options can vary. In addition, several other key parameters vary between the methods discussed herein, including the destructive vs nondestructive nature of the measurement process (including in situ vs ex situ measurement options), the analytical data collection times, and the amount of sample required for analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward Machine Learning-Driven Mass Spectrometric Identification of Trichothecenes in the Absence of Standard Reference Materials

While a significant body of work exists on the detection of commonly known trichothecene toxins, biological, environmental, and other transformational processes can generate many under-characterized and unknown modified trichothecenes. Lacking both analytical reference standards and associated mass spectral databases, identification of these modified compounds reflects both a challenge and a critical gap from forensic and public health perspectives. Here we report here the application of machine learning (ML) techniques toward identification of discriminative fragment ions from mass spectrometric data that can be exploited to detect evidence of type A and B trichothecenes. The goal of this work is to establish a new method for the identification of unknown, though structurally similar trichothecenes, by leveraging objective ML techniques. Discriminative fragments derived from a series of gradient-boosted machine learners are then used to develop ML-driven precursor ion scan (PIS) methods on a triple quadrupole mass spectrometer (QQQ) for screening of “unknown unknown” trichothecenes. Specifically, we apply the PIS method to a laboratory-synthesized trichothecene, a first step in demonstrating the power of alternative, machine learning-driven mass spectrometric methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗