A review of the Thermoelectronic Laser Energy Converter /TELEC/ Program at Lewis Research Center

The investigation of the Thermoelectronic Laser Energy Converter (TELEC) concept at the Lewis Research Center (LeRC) began with a feasibility study of a 1 megawatt sized TELEC system. The TELEC was to use either cesium vapor or hydrogen as the plasma medium. The cesium vapor TELEC appears to be the more practical device studied with an overall calculated conversion efficiency of greater than 48%. Following this study, a small TELEC cell was fabricated which demonstrated the conversion of a small amount of laser power to electrical power. The cell developed a short circuit current of 0.7 amperes and an open circuit voltage, as extrapolated from volt-ampere curves, of about 1.5 volts. Work is now in progress to construct and test a cesium vapor TELEC capable of absorbing 20% of an incident 10 kW, 10.6 micrometer beam, and converting 35% of this power to electrical power.

Alger, D. L.↗

Fabrication and testing of silver-hydrogen cells

The development and life testing of single electrode and multi electrode stacks to optimize the individual components and characterize the performance of a silver hydrogen battery system are described. A NASA-developed inorganic separator material was used as the main separator within the cells. Single electrode test cells were cycled at 75% of nominal capacity out through approximately 1,000 cycles in a number of cases where deterioration in performance was observed. This deterioration appears to be a decay in usable capacity of the silver electrode; but the exact mechanism is still unidentified. Twenty ampere-hour boilerplate test cells consisting of a stack of ten silver electrodes and twenty hydrogen electrodes were cycled also at 75% depth of discharge. The oldest stack achieved 522 stable cycles to the end of the program. Weight analysis of light-weight cells showed that 50 ampere-hour cells with improved components could be capable of as much as 40 watt hours per pound.

Klein, M. G.↗

Orbiting astronomical observatory battery and power system design

The battery design of OAO-C (OAO-3) is given and consists of three-20 ampere hour 22 series connected cells in the battery. There are three batteries per spacecraft. The packaging configuration is described. The charging-discharging operations and the voltage potential of the battery system are discussed. Graphs are presented for the voltage limits (battery voltage versus temperature) and end of dark voltages (battery voltage versus ampere-hours discharged) of the battery system used on OAO-3. Data tables are also presented which give a summary of the battery performance and a comparison of OAO-3 with OAO A-2.

Ford, F. E.↗

The standard 20 AH battery

The modular power system, which is the first intended use for the NASA standard battery, is basically a four foot by four foot by eighteen inch box which can handle a complement of three 20 ampere hour batteries or later on the intended use is for three 50 ampere hour batteries to be the full complement. The system is designed to be used as a plug on component on a multi mission modular spacecraft. It has as a design point a basically 1250 watt orbital average load. The way it breaks up in a near earth orbit it would be somewhere around 1,000 watts for everything except 10 minutes, and during any 10 minute period it may go up to a peak of 3,000 watt load. Features of the battery reviewed include criteria to store electrical energy, the battery package, the covers and cases, and electrolytes. The capacities expected are 90 percent, the average cell capacity for 24 C, 90 percent of the actual battery capacity of 19 C, and 85 percent of the actual 25 degree battery capacity at zero discharge voltage for 50 percent DOD new battery is in the vicinity expected or predicted of 26.4 volts.

Zollner, M. T.↗

Large cells and their performance

Some of the large primary cells presently made, ranging from 2,000 to 10,000 ampere-hours are discussed. Performance data obtained on a 2,000 ampere-hour cell are graphically presented.

Goebel, F.↗

Solid-state switch modeling

A model for predicting voltages and currents of passive loads during turn on and turn off of remote power controllers is presented. The model is concerned with two devices, a five ampere device and a twenty ampere device. The model is presented as a general circuit diagram. The load current is determined by the load parameters and the conditions at switching and the steady state conditions are reached according to time constants determined by the load. The model is used to analyze the turn on and turn off conditions of certain loads including a R-C load and a R-L load.

Raburn, W. D.↗

Update of the IUE battery in-flight performance

The in-flight performance data of two 17-cell, 6-ampere-hour nickel cadmium spacecraft batteries are presented covering 22 months of operation. Fluctuations in the battery voltage and the battery temperature are presented for spacecraft movement throughout a beta range of 0 to 130 deg. The battery discharge voltages during the peak eclipse seasons, daily seasons, and daily eclipse periods are noted. Finally, the spacecraft data are compared to data from a 6-ampere-hour test pack and test flight data.

Tiller, S. E.↗

Additional Reversal Characteristics of Sealed Nickel Cadmium Cells

The reversal characteristics of nickel cadmium cells are discussed. The evolution of hydrogen from the positive electrode is described when the nickel cadmium cell is completely discharged. Results indicate that one ampere hour of overdischarge in reversal can generate enough hydrogen to increase the cell pressure of an average size cell, 20- to 50-ampere hour cell, by 120 psi.

Ritterman, P. F.↗

Pocket nickel cadmium cell and battery evaluation

The Nickel Cadmium 129-ampere hour cell was tested in order to characterize the cell under controlled conditions. Results of charge characterization and discharge characterization are reported. Ampere hour efficiency, open circuit stand, and cycle life operation results are included. The battery is briefly described.

Lear, J. W.↗

Status of nickel-hydrogen cell technology

Nickel hydrogen cell technology has been developed which solves the problems of thermal management, oxygen management, electrolyte management, and electrical and mechanical design peculiar to this new type of battery. This technology was weight optimized for low orbit operation using computer modeling programs but is near optimum for other orbits. Cells ranging in capacity up to about 70 ampere-hours can be made from components of a single standard size and are available from two manufacturers. The knowledge gained is now being applied to the development of two extensions to the basic design: a second set of larger standard components that will cover the capacity range up to 150 ampere-hours; and the development of multicell common pressure vessel modules to reduce volume, cost and weight. A manufacturing technology program is planned to optimize the producibility of the cell design and reduce cost. The most important areas for further improvement are life and reliability which are governed by electrode and separator technology.

Warnock, D. R.↗

Electromagnetic measurement of lightning strikes to aircraft

Recent in-flight direct-strike lightning research, using an NASA F-1068 aircraft, is reviewed. The instrumentation system which records the rates of change of electric and magnetic flow density at several locations on the aircraft and rate of change of strike current to the boom is described. The measurement parameters are: rate of change of electric flux density over a range of 50 amperes per square meter, rate of change of magnetic flux density over a range of 20,000 tesla per second, and rate of change of strike current over a range of 100 kilo-amperes per microsecond. The isolated and shielded instrumentation system employs high-sample-rate digital transient recorders with augmented memory capacity and a wideband analog recorder for data acquisition and recording. The data obtained during the 1980 flight test program are presented and the data significance is discussed.

Pitts, F. L.↗

Effect of positive pulse charge waveforms on the energy efficiency of lead-acid traction cells

The effects of four different charge methods on the energy conversion efficiency of 300 ampere hour lead acid traction cells were investigated. Three of the methods were positive pulse charge waveforms; the fourth, a constant current method, was used as a baseline of comparison. The positive pulse charge waveforms were: 120 Hz full wave rectified sinusoidal; 120 Hz silicon controlled rectified; and 1 kHz square wave. The constant current charger was set at the time average pulse current of each pulse waveform, which was 150 amps. The energy efficiency does not include charger losses. The lead acid traction cells were charged to 70 percent of rated ampere hour capacity in each case. The results of charging the cells using the three different pulse charge waveforms indicate there was no significant difference in energy conversion efficiency when compared to constant current charging at the time average pulse current value.

Smithrick, J. J.↗

Use of the Charge/Discharge (C/D) ratio to aument voltage limit (V sub T) charge control in the ERBS spacecraft

A 50-ampere hour nickel cadmium cell test pack was operated in a power profile simulating the orbit of the Earth Radiation Budget Satellite (ERBS). The objective was to determine the ability of the temperature compensated voltage limit (V sub T) charge control system to maintain energy balance in the half sine wave-type current profile expected of this mission. The four-cell pack (50 E) was tested at the Naval Weapons Support Center (NWSC) at Crane, Indiana. The ERBS evaluation test consisted of two distinct operating sequences, each having a specific purpose. The first phase was a parametric test involving the effect of V sub T level, temperature, and Beta angle on the charge/discharge (C/D) ratio, an indicator of the amount of overcharge. The second phase of testing made use of the C/D ratio limit to augment the V sub T charge limit control. When the C/D limit was reached, the current was switched from the taper mode to a C/67 (0.75 A) trickle charge. The use of an ampere hour integrator limiting the overcharge to a C/67 rate provided a fine tuning of the charge control technique which eliminated the sensitivity problems noted in the initial operating sequence.

Halpert, G.↗

The Dynamics Explorer Langmuir probe instrument

The Dynamics Explorer Langmuir probe instrument (DE-LANG), a spare unit from the Pioneer Venus mission that has been modified to work with the DE spacecraft, is described. Two independent sensors are connected to individual adaptive sweep voltage circuits that continuously track the changing electron temperature and spacecraft potential while autoranging electrometers adjust their gain in response to the changing plasma density. The control signals used in achieving this automatic tracking provide a continuous monitor of the ionospheric parameters without telemetering each volt-ampere curve. In addition, internal data storage circuits permit high-resolution, high-data-rate sampling of selected volt-ampere curves for transmission to the ground to verify or correct the inflight processed data.

Krehbiel, J. P.↗

Improved ion containment using a ring-cusp ion thruster

A 30-centimeter diameter ring-cusp ion thruster is described which operates at inert gas ion beam currents up to about 7 ampere, with significant improvements in discharge chamber performance over conventional divergent-field thrusters. The thruster has strong boundary ring-cusp magnetic fields, a diverging field on the cathode region, and a nearly field-free volume upstream of the ion extraction system. Minimum ion beam production costs of 90 to 100 watts per beam ampere (W/A) were obtained for argon, krypton and xenon. Propellant efficiencies in excess of 0.90 were achieved at 100 to 120 W/A for the three inert gases. The ion beam charge-state was documented with a collimating mass spectrometer probe to allow evaluation of overall thruster efficiencies.

Sovey, J. S.↗

Cycle life test and failure model of nickel-hydrogen cells

Six ampere hour individual pressure vessel nickel hydrogen cells were charge/discharge cycled to failure. Failure as used here is defined to occur when the end of discharge voltage degraded to 0.9 volts. They were cycled under a low earth orbit cycle regime to a deep depth of discharge (80 percent of rated ampere hour capacity). Both cell designs were fabricated by the same manufacturer and represent current state of the art. A failure model was advanced which suggests both cell designs have inadequate volume tolerance characteristics. The limited existing data base at a deep depth of discharge (DOD) was expanded. Two cells of each design were cycled. One COMSAT cell failed at cycle 1712 and the other failed at cycle 1875. For the Air Force/Hughes cells, one cell failed at cycle 2250 and the other failed at cycle 2638. All cells, of both designs, failed due to low end of discharge voltage (0.9 volts). No cell failed due to electrical shorts. After cell failure, three different reconditioning tests (deep discharge, physical reorientation, and open circuit voltage stand) were conducted on all cells of each design. A fourth reconditioning test (electrolyte addition) was conducted on one cell of each design. In addition post cycle cell teardown and failure analysis were performed on the one cell of each design which did not have electrolyte added after failure.

Smithrick, J. J.↗

Test results of a ten cell bipolar nickel-hydrogen battery

A ten cell bipolar nickel hydrogen 6.5 ampere-hour battery demonstrated over 2000 low Earth orbit cycles at an 80 percent depth-of-discharge. Charge/discharge cyclic ampere-hour and watt-hour efficiencies of 88 and 76 percent, respectively, observed. Peak power capability was determined at 1.1 kW. A 10C discharge rate yields 83 percent of the nominal stark capacity to the 1.0 volt cut off in just under 6 minutes.

Cataldo, R. L.↗

Test methods and results of the 10-cell bipolar Ni-H2 battery

Characterization tests were carried out at three charge levels and four discharge levels. The "c' or capacity of the battery is designated at 6.5 ampere-hours. The recharge ampere-hours was the same for all test conditions, 6.5 A-H, regardless of the discharge capacity removed for any particular discharge rate. Less capacity can be removed at higher discharge rates to the same termination voltage, which was 0.50 volts for the weakest (lowest voltage) cell. The general trend of efficiencies increases as the charge rate increases as noted in results of the table included in the handout package. The data also indicate the efficiency increases as the discharge rate decreases. This is true; however, efficiencies at the discharge rates of c and 2c are penalized because these cycles received more overcharge than necessary.