Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “amine”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Comparison of Alternative Configurations of an Integrated Open-Loop Carbon Dioxide Removal System using Liquid Amine

Several carbon dioxide removal systems are being investigated for applications in microgravity. The liquid amine wedge system utilizes the capillary action of liquids to prevent the mixing of the air and liquid while still allowing for carbon dioxide capture at their interface. A one crew mission requires approximately 1 kg per day of carbon dioxide removal to prevent adverse health effects. A proposed design of a wedge tray system can be improved from the initial testing parameters to achieve the required carbon dioxide capture for one crew. The wedge trays in the contactor can be organized in either a parallel configuration to accumulate less CO2 in the liquid but at a higher flow rate or a series configuration to yield a higher weight percentage of CO2 in the liquid but at a lower flow rate. The gas flow rate and composition were held constant at 26scfm and 2600ppm, respectively, due to constraints of other proposed systems but the liquid flow rate was adjusted between 0.1mL/min and 10mL/min. The flow rate that yielded the best carbon dioxide capture was X mL/min and Y mL/min for the parallel and series configurations, respectively. The degasser temperature and pressure were varied from 80 to 100°C and 0 and -3 inHg. The largest carbon dioxide flux of Z kg/day/m2 was observed at a contactor liquid flow rate of X mL/min and a degasser temperature and pressure of T°C and P inHg.

Adrian Cortez↗

Ammonia-Removal Efficiency By Full-Scale Carbon-Based Trace-Contaminant Sorbent Monoliths Integrated With the Rapid-Cycle Amine (RCA) Swing Bed

Results are presented on full-scale performance testing of vacuum-regenerable, carbon based sorbent monoliths for trace-contaminant (TC) removal integrated with the Rapid-Cycle Amine (RCA) swing bed for use in the Portable Life Support System (PLSS) during Extravehicular Activities (EVAs). The current state-of-art in TC-control technology involves the use of a packed bed of acid-impregnated granular charcoal, which is difficult to regenerate. The carbon-based sorbent under development in this project can be regenerated by exposure to vacuum at room temperature. Data on cyclic sorption-desorption of ammonia, which is a major TC of concern, were collected in a simulated PLSS ventilation loop which involved the RCA placed upstream of the Trace Contaminant Control System (TCCS). Results of testing involving pressure-swing operation of the integrated TCCS/RCA system indicate ammonia-removal efficiency exceeding 80% throughout multiple sorption-desorption cycles. This paper presents an overview of the TCCS research, the favorable results obtained, and provides insight into future work needed to further the technology development.

Marek A Wójtowicz↗

Evaluation of Long-Term Storage Stability and Operational Efficiency of Rapid Cycle Amine Adsorbents

With the recent incorporation of Mars Extravehicular Activity (EVA) into the 2025 NASA roadmap, Rapid Cycle Amine (RCA) technology advancement within the Exploration Extravehicular Mobility Unit (xEMU) applies to both the upcoming Lunar Artemis missions and future human exploration of Mars. The incorporation of commercial spacesuit vendors to service NASA’s crewed-space programs since 2021 has increased the demand for regenerable, RCA-based carbon dioxide (CO2) and humidity control adsorbents. The regenerable RCA subunit is the most advanced, long-term solution for CO2 removal and humidity control, enabling both lunar and Martian EVAs. The adsorbent selected for use within the RCA unit must exhibit sufficient storage stability and operational efficiency for prolonged missions. As XploSafe worked to simultaneously develop both a recirculating sub-atmospheric test rig and adsorbents for the RCA system within the xEMU, several novel adsorbents were evaluated for long-term storage stability in support of future extended-duration missions. The chosen materials were periodically evaluated by nuclear magnetic resonance (NMR) spectroscopy, thermal desorption-coupled with gas chromatography/mass spectrometry (TD-GC/MS), and CO2 adsorption to assess long-term storage efficacy across various environmental storage conditions. NMR spectroscopy was utilized by extracting the active CO2 adsorbing chemical from the solid support with deuterated solvent and comparing the spectra over time for degradation and change. The solid adsorbents were also analyzed via TD-GC/MS to reveal any potential off-gassing chemicals over time. Additionally, XploSafe’s breakthrough test rig was utilized to dose the solid adsorbents with a 585 BTU/h metabolic rate flow-equivalent CO2 stream and monitored for 0–99% CO2 breakthrough. The performance metrics from the breakthrough analysis were compared over the storage study duration for CO2 removal and humidity control. Xplo-SA9T was evaluated for 24 months, whereas two additional adsorbent variants, MMPA-Sorbent and LPEI-Sorbent, were each evaluated for 12 months.

John R Tidwell↗

Recirculating and Sub-Atmospheric Rapid Cycle Amine Swing Bed Testing at Various Metabolic Profiles, Temperatures, and Half-Cycle Times

Sixty years since the first spacewalk, NASA’s Extravehicular Mobility Unit (xEMU) exploration space suit has undergone numerous design improvements and iterations. As commercial manufacturers develop next-generation systems to support increasingly complex missions, including Moon-to-Mars architecture prototyping and the design of the Martian Portable Life Support System (PLSS), material selection and individual subunit testing under realistic metabolic and pressure conditions are paramount. To determine whether a reusable carbon dioxide (CO 2 ) scrubber design and adsorbent can be utilized in new suit configurations, an all-encompassing test rig is required to compare existing and newly developed technologies. The test rig must be capable of sub-atmospheric testing, calibrated humid CO 2 dosing, and facilitation of the evaluation of sorbents across a wide range of operational requirements. Recently, XploSafe has developed an Extravehicular Mobility Unit (xEMU) testing rig specifically designed to explore CO 2 and humidity control materials for spacesuits. This closed-loop recirculating swing bed (Rapid Cycle Amine Test Rig) was utilized to compare adsorbent utility across a wide range of xEMU operating conditions. Following successful testing with Xplo-SA9T over multiple simulated eight-hour Extravehicular Activity (EVA) tests, improvements to the test stand were considered. Regeneration vacuum supply within the test rig was updated to more closely resemble space vacuum, theoretically increasing half-cycle timing. An improved water vapor delivery system was incorporated to dose a wider calibrated range of humidity over both short and long-duration EVAs. A range of metabolic profiles between 800 and 3000 BTU/h were tested, and the corresponding average CO 2 steady-states were compared. The effect of dosing temperature at the adsorbent bed inlet between 10 and 40 ̊C and the corresponding CO 2 removal efficiency was also evaluated.

John R Tidwell↗

Electrically Conductive Amine Functionalized Reduced Graphite Oxide Foam for CO 2 Removal from the Air

Rapid regeneration of CO 2 adsorbents is critical to improving the productivity of direct air capture (DAC) systems. In this study, we codesigned a material to have appropriate electrical conductivity and CO 2 adsorption properties to enable efficient CO 2 capture from air. Specifically, we present a poly(ethylenimine) (PEI)-impregnated thermally annealed graphite oxide (TAGO900) foam adsorbent tailored for vacuum-assisted electrically driven thermal swing adsorption (V-ETSA). This structured adsorbent leverages the high electrical conductivity of the reduced graphite oxide framework to enable fast and direct heating of the adsorbent material by electrical resistance heating (Joule heating). An optimal sample, 40 wt % PEI (molecular weight 25k) impregnated TAGO900, shows the best balance between adsorption capacity (1.54 mmol g –1 ) and adsorption rates (0.016 mmol g –1 min –1 ) using fixed bed breakthrough experiments at 25 °C and 70% RH using 50 sccm 400 ppm of CO 2 /N 2 flow. Compared to conventional temperature vacuum swing adsorption (TVSA), the V-ETSA approach achieves substantially faster CO 2 desorption, achieving average desorption rates (including cooling time) of 0.09 mmol g –1 min –1 ─approximately 2.5 times faster than TVSA under similar operating conditions. The maximum desorption rate reaches 0.23 mmol/g/min during the desorption stage. These results underscore the importance of the direct heating strategy, such as Joule heating, for fast and highly productive vacuum swing adsorption in DAC systems.

amines↗