Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Ionization Profile Monitors for the IOTA Proton Beam

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. Two such monitors - one vertical and one horizontal - are being developed for installation in the IOTA storage ring at Fermilab. They will be used for turn-by-turn (microseconds scale) measurements of the 70 MeV/c IOTA proton beam sizes. In this paper we present the IPMs design (largely following the FNAL Booster IPMs which employ no external guiding magnetic fields), their mechanical, vacuum, and electric subsystems and DAQ, and discuss anticipated effects on the beams circulating in IOTA.

43 PARTICLE ACCELERATORS↗

Ionization Profile Monitors for the IOTA Proton Beam

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. Two such monitors - one vertical and one horizontal - are being developed for installation in the IOTA storage ring at Fermilab. They will be used for turn-by-turn (microseconds scale) measurements of the 70 MeV/c IOTA proton beam sizes. In this paper we present the IPMs design (largely following the FNAL Booster IPMs which employ no external guiding magnetic fields), their mechanical, vacuum, and electric subsystems and DAQ, and discuss anticipated effects on the beams circulating in IOTA.

43 PARTICLE ACCELERATORS↗

A search for energetic ion directivity in large solar flares

One of the key observational questions for solar flare physics is: What is the number, the energy spectrum, and the angular distribution of flare accelerated ions? The standard method for deriving ion spectral shape employs the ratio of influences observed on the 4-7 MeV band to the narrow neutron capture line at 2.223 MeV. The 4-7 MeV band is dominated by the principal nuclear de-excitation lines from C-12 and O-16 which are generated in the low chromosphere by the direct excitation or spallation of nuclei by energetic ions. In contrast, the narrow 2.223 MeV line is produced by the capture of thermal neutrons on protons in the photosphere. These capture neutrons are generated by energetic ion interactions and thermalized by scattering in the solar atmosphere. In a series of papers, Ramaty, Lingenfelter, and their collaborators have calculated the expected ratio of fluence in the 4-7 MeV band to the 2.223 MeV line for a wide range of energetic ion spectral shapes (see, e.g. Hua and Lingenfelter 1987). Another technique for deriving ion spectral shapes and angular distributions uses the relative strength of the Compton tail associated with the 2.223 MeV neutron capture line (Vestrand 1988, 1990). This technique can independently constrain both the angular and the energy distribution of the energetic parent ions. The combination of this tail/line strength diagnostic with the line/(4-7) MeV fluence ratio can allow one to constrain both properties of the energetic ion distributions. The primary objective of our Solar Maximum Mission (SMM) guest investigator program was to study measurements of neutron capture line emission and prompt nuclear de-excitation for large flares detected by the Solar Maximum Mission/ Gamma-Ray Spectrometer (SMM/GRS) and to use these established line diagnostics to study the properties of flare accelerated ions.

Vestrand, W. Thomas↗

Diagnosing the DARHT Electron Beam-Target Interaction and Hydrodynamic Expansion [Dissertation]

Quantitative electron beam-target interaction studies on the Dual-Axis Radiographic Hydrodynamic Test (DARHT) electron linear induction accelerators have only been performed recently. This includes characterization of the temperature, density, pressure, extent, and expansion velocity of the plasma plume. The results presented in this dissertation present a detailed and unified overview of the accelerator systems, target heating physics, beam transport, and diagnostic tools. Additional information includes calibration sources, radiation hydrodynamics, spectroscopic-quality radiation transport modeling, experimental measurements, and analyses of electron beam driven aluminum experiments. The first set of spatially and temporally resolved spectroscopic measurements of electron beam driven aluminum are presented. Contamination quantification analyses are used to understand the origin of the strong Na-I 3p-3s lines that are observed in absorption within the aluminum plasma continuum. These results inform the creation of the first spectroscopic-quality radiation transport model that links several atomic physics codes to interpret the conditions from which the Na-I lines originate. A good agreement is found between the surface analysis results and the model which confirms the concentration of the sodium present within the aluminum alloy foil material. It also demonstrates, for the first time on electron beam-driven target experiments, the ability to interpret plasma conditions from measured absorption lines. In a second experimental campaign which focuses on pure aluminum, the Al-I 3p-4s and 3p3d doublets are both measured in emission. A detailed analysis of the Al-I 3p-4s doublet reveals that the lines undergo moderate self-absorption. A simple model of the self-absorption effect is successfully used to match measured spectra at various temperature/density/plasma scale length combinations. These measurements led to the realization of the minimum density that can be resolved by the spectrometers for the Al-I 3p-4s lines due to the large slit width required to observe a signal on aluminum. These measurements also demonstrate the sensitivity of visible and long wave UV spectroscopy to minor changes in both temperature and density. The simple self-absorption model will be useful for analysis of other beam-target interaction experiments with spectra exhibiting either self-absorption or full self-reversal. Substantial headway has been made on the modeling front by linking together several codes needed to model both the energy deposition, hydrodynamic motion, and atomic kinetics to produce synthetic spectral calculations that are compared with experimental measurements. There exists ample space for improvement, especially with benchmarking the hydrodynamics codes and equation-of-state tables with experimental measurements. The X-ray diagnostics required to make these new measurements along with the simulation capabilities required to interpret the results are under development and will be the subject of future studies.

43 PARTICLE ACCELERATORS↗

Wave-particle interaction phenomena associated with shocks in the solar wind

Microscopic wave-particle interaction phenomena must generally affect the evolution of a traveling interplanetary discontinuity such as a collisionless shock, and solar wind plasma instabilities should also be associated with interplanetary acceleration, diffusion, and dissipation. Recent local measurements from diagnostics on widely separated spacecraft illustrate some examples of these interaction phenomena, and two bounding cases are considered in detail here. It is shown that the interplanetary shock of September 14, 1974 (detected on IMP-7, 8, Hawkeye-1, and Pioneer 11) was associated with intense local electrostatic noise and ion acceleration, while the shock of January 6, 1975 (detected on IMP-7 and Helios-1) had no detectable electrostatic turbulence.

Scarf, F. L.↗

Uncertainty Propagation from Experiment Measurements to Modeling Approaches: A Case for SMR Steam Entrainment Testing

To license new and advanced reactor designs, regulators must be convinced that their unique safety cases—relative to existing large scale reactors—have been adequately addressed by the designed reactor protection systems. In water cooled small modular reactors (SMRs), droplet entrainment in steam flow has significant implications on the progression of accident scenarios due to its compact design features, which requires representative test data applicable to SMR designs. Computer code, modeling and simulation (M&S) tools and models require adequate verification, assessment, and qualification. This includes M&S results validation against scaled empirical data within allowable uncertainty bands to gain regulatory approvals during the various stages of reactor system design, demonstration, and commercialization. However, measurement uncertainty within the empirical datasets and test data applicability ranges requires careful consideration of M&S inputs (i.e., boundary conditions, and initial conditions), and verification and validation efforts. This study focuses on uncertainty quantification in designing scaled test facilities for SMR applications with appropriate measurements and a standard data-reduction method to estimate thermal hydraulics characteristics parameters that incorporate physics phenomena of interest. In addition, this study supports the evaluation model development and assessment process using M&S that interfaces with advanced computing tools and digital twin capabilities. This will allow synchronization between experiment and modeling approaches for droplet entrainment testing and analysis, improving diagnostics, prognostics, and decision-making to accelerate regulatory approval.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Space-Charge and Other Effects in Fermilab Booster and IOTA Rings’ Ionization Profile Monitors

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. At low beam intensities, initial velocities of the secondaries to collect (ions or electrons) result in the IPM profile smearing. At high beam intensities, the space-charge forces make the measured IPM profiles significantly different from those of the beams. We analyze dynamics of the secondaries in IPMs, describe an effective algorithm to reconstruct the beam sizes from the measured IPM profiles and apply it to the Fermilab 8 GeV proton Booster and 70 MeV/c IOTA ring IPMs.

Shiltsev, Vladimir D.↗

Space-Charge Effects in Ionization Beam Profile Monitors

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. At high beam intensities, the space-charge forces make the measured IPM profiles significantly different from those of the beams. We analyze dynamics of the secondaries in IPMs and develop an effective algorithm to reconstruct the beam sizes from the measured IPM profiles. Efficiency of the developed theory is illustrated in application to the Fermilab 8 GeV proton Booster IPMs.

Shiltsev, Vladimir D.↗

Initial conditions for simulations of beam physics in linear induction accelerators

Flash radiography of hydrodynamic experiments driven by high explosives is a well-known diagnostic technique in use at many laboratories. At Los Alamos, the DualAxis Radiographic Hydrodynamic Test (DARHT) facility two linear induction electron accelerators (LIAs) make the bremsstrahlung radiographic source spots for point projection radiographs from orthogonal views. A new LIA, called Scorpius, is presently under development to advance this technology. To better understand electron-beam physics in these LIAs, numerical simulations are frequently performed with the objective of improving the radiography. At Los Alamos we frequently use the TRAK ray-trace and LSP particle-in-cell (PIC) codes to simulate the injector, and the XTR and LAMDA envelope/centroid codes along with LSP to simulate transport of the accelerated beam through the LIAs. The LIA simulations need the injected beam parameters as initial conditions for calculating beam transport and stability. The determination of these initial conditions is the topic of this note.

43 PARTICLE ACCELERATORS↗

Velocity distributions of ion beams in the plasma sheet boundary layer

The value of measured ion-beam velocity distributions as diagnostic tools to characterize the propagation and acceleration of particle beams in the plasma-sheet boundary layer is assessed. Models based on adiabatic deformation of a flowing Maxwellian, acceleration by field-aligned potentials, and current-sheet acceleration are fitted to observational data, and the results are presented in extensive diagrams and graphs. The data are found to be consistent with models involving field-aligned or cross-tail potential drops, but not with models based solely on the adiabatic deformation of initially isotropic distributions.

Eastman, T. E.↗

Tracing Chromospheric Evaporation in Radio and Soft X-rays

There are three publications in refereed journals and several presentations at scientific conferences resulted from this work, over a period of 6 months during 1995/1996. In the first paper, the discovery of the chromospheric evaporation process at radio wavelengths is described. In the second paper, the radio detection is used to quantify electron densities in the upflowing heated plasma in flare loops, which is then compared with independent other density measurements from soft X-rays, or the plasma frequency of electron beams originating in the acceleration region. In the third paper, the diagnostic results of the chromospheric evaporation process are embedded into a broader picture of a standard flare scenario. Abstracts of these three papers are attached.

Aschwanden, Markus J.↗

Efficient six-dimensional phase space reconstructions from experimental measurements using generative machine learning

Next-generation accelerator concepts, which hinge on the precise shaping of beam distributions, demand equally precise diagnostic methods capable of reconstructing beam distributions within six-dimensional position-momentum spaces. However, the characterization of intricate features within six-dimensional beam distributions using current diagnostic techniques necessitates a substantial number of measurements, using many hours of valuable beam time. Novel phase space reconstruction techniques are needed to reduce the number of measurements required to reconstruct detailed, high-dimensional beam features in order to resolve complex beam phenomena and as a feedback in precision beam shaping applications. In this study, we present a novel approach to reconstructing detailed six-dimensional phase space distributions from experimental measurements using generative machine learning and differentiable beam dynamics simulations. We demonstrate that this approach can be used to resolve six-dimensional phase space distributions from scratch, using basic beam manipulations and as few as 20 two-dimensional measurements of the beam profile. We also demonstrate an application of the reconstruction method in an experimental setting at the Argonne Wakefield Accelerator, where it is able to reconstruct the beam distribution and accurately predict previously unseen measurements 75× faster than previous methods.

43 PARTICLE ACCELERATORS↗

Correct Initial Conditions for Simulations of Beam Physics in Linear Induction Accelerators

Flash radiography of hydrodynamic experiments driven by high explosives is a well-known diagnostic technique in use at many laboratories. At Los Alamos, the Dual Axis Radiographic Hydrodynamic Test (DARHT) facility two linear induction electron accelerators (LIAs) make the bremsstrahlung radiographic source spots for point projection radiographs from orthogonal views. A new LIA, called Scorpius, is presently under development to advance this technology. To better understand electron-beam physics in these LIAs, numerical simulations are frequently performed with the objective of improving the radiography. At Los Alamos we frequently use the TRAK ray-trace and LSP particle-in-cell (PIC) codes to simulate the injector, and the XTR and LAMDA envelope/centroid codes along with LSP to simulate transport of the accelerated beam through the LIAs. The LIA simulations need the injected beam parameters as initial conditions for calculating beam transport and stability. The determination of these initial conditions is the topic of this note.

43 PARTICLE ACCELERATORS↗

Feasibility study for the hard x-ray free electron laser based on synergistic use of conventional and plasma accelerator technologies

Hard x-ray free electron lasers (XFELs) are great diagnostic tools in modern science. A number of XFELs have been constructed worldwide in the past decade. In the past, Los Alamos National Laboratory has expressed interest in hosting a similar facility to support ongoing Programs. The facility has been envisioned based on a conventional radio frequency (RF) accelerator technology. As a result, the estimated size and cost of the anticipated facility turned out to be large, which significantly decreased attractiveness of this project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic evolution of ultracold electron beams from nanostructured cathodes

Dynamic Coulomb expansion of dense, nonuniform particle beamlets can lead to causticlike formations in the charge density profile of the resultant beam. Such features only occur for cold beams where thermal diffusion of the particles is minimized. These phenomena have been observed experimentally for select cases with ion beams but not yet for electron beams as the electron dynamics occur over far faster timescales. We simulate the interaction of electron bunches while varying the initial transverse temperature and density profiles to determine the thresholds that characterize this pattern formation. Furthermore, we extend the simulations to geometric arrangements that are more pertinent to the nanotip cathode application and consider the effects of asymmetries and the impact of a low-density halo on the overall process. The simulations are conducted using a previously documented high-fidelity algorithm for collisional particle dynamics. These studies identify the temperature and density thresholds required for caustic formation and provide guidance for optimizing the design of nanoscale structured cathodes. We also demonstrate that the correlation between the final density patterns and the underlying beam parameters enables a virtual diagnostic tool for measuring ultralow emittance beams solely based on a transverse charge density profile.

43 PARTICLE ACCELERATORS↗

Improvement in the spatial resolution of heavy ion beam probe measurements through application of ion optics

A technique for more accurately modeling and improving the spatial resolution of heavy ion beam probe measurements is described. We use a set of particle trajectories to numerically determine the focusing properties of a complicated three-dimensional magnetic field and characterize those properties with a transfer matrix. We then modify the transfer matrix approach of traditional ion optics to include a parameter that describes the ionization location of the detected ions. The ion optics model calculated using this technique enables a more accurate description of the particle trajectories than previously feasible. The model also allows one to easily determine an initial beam focus that could be used during experimental operation to optimize the spatial resolution of measurements. The technique has been applied to the design of a heavy ion beam probe diagnostic for the Wendelstein 7-X stellarator and improvements in the modeled spatial resolution by a factor of about 2 over previous estimates are possible. As a result, the improved spatial resolution will enable measurements of plasma fluctuations with smaller wavelengths than would otherwise be possible.

43 PARTICLE ACCELERATORS↗

Development of a colinear Second-Harmonic Orthogonal Polarization (SHOP) interferometer for electron areal density measurements in Magnetically Insulated Transmission Lines (MITLs)

Experimental measurements of low density plasmas forming in Magnetically Insulated Transmission Line (MITL) regions are desired to improve our understanding of current loss and power flow. Therefore, a new optical interferometer diagnostic was commissioned via this LDRD project. To measure the expected 10 13 - 10 17 cm -3 electron densities inside the 0.5 - 6 mm Anode-Cathode (A-K) gaps, a colinear SHOP interferometer diagnostic was constructed. The diagnostic was initially fielded on the University of New Mexico (UNM) Helicon-Cathode (HelCat) plasma device which provided a highly repeatable and well understood plasma source for which the colinear SHOP interferometer’s functionality could be verified and measured. Utilizing the highly repeatable plasma source and shot averaging, the interferometer was able to achieve an areal density sensitivity of 1×10 14 cm -2 . This work at UNM lead to a Review of Scientific Instruments (RSI) publication [20], DOI:10.1063/5.0101687. After the diagnostic’s capability was proven at UNM, the colinear SHOP interferometer was commissioned for use on the Sandia National Laboratories (SNL) Mykonos accelerator. Here, it provided the first temporal areal density measurements of plasma formation in a parallel plate MITL. The diagnostic was able to achieve a single shot (no multi-shot averaging like at UNM) areal density sensitivity of 1×10 15 cm -2 along a ~ 2mm probing path length, which provided adequate capability to conduct fundamental physics research of MITL plasma formation. CHICAGO and ALEGRA simulations support the diagnostics experimental findings. More experimental and computational work will continue, likely leading to another publication(s). The smaller scale Mykonos accelerator work has also provided justification that the colinear SHOP interferometer is a capable diagnostic for measuring plasma areal densities in the inner MITL and convolute regions of larger TW-class accelerators like SNL’s Z machine.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Latent diffusion can map beam loss to two-dimensional phase-space projections

Beam loss monitors (BLMs) and beam current monitors (BCMs) are ubiquitous at particle accelerators around the world. These simple devices provide noninvasive high-level beam measurements but give no insight into the detailed 6D (𝑥,𝑦,𝑧,𝑝 𝑥 ,𝑝 𝑦 ,𝑝 𝑧 ) beam phase-space distributions or dynamics. We show that generative conditional latent diffusion models can learn intricate patterns to solve the extreme inverse problem of mapping waveforms of tens of BLMs or BCMs along an accelerator to detailed 2D projections of a charged particle beam’s 6D phase-space density. This transformational method can be used at any particle accelerator to transform simple noninvasive devices into detailed beam phase-space diagnostics. We demonstrate this concept via multiparticle simulations of the high-intensity beam in the kilometer-long Los Alamos Neutron Science Center linear proton accelerator.

43 PARTICLE ACCELERATORS↗