Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ablator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Supercritical Drying of Wet Gel Layers Generated Inside ICF Ablator Shells

Spherical ablator shells that contain a thin layer of ultralow-density polymer foam have recently attracted attention in the inertial confinement fusion (ICF) community as they can be used to bring dopants for diagnostics and nuclear physics experiments in direct contact with the deuterium-tritium (DT) fuel or to study new ignition regimes by enabling the formation of uniform liquid DT fuel layers. We developed a method to fabricate these foam-lined ablator shells using a prefabricated ablator as a mold to cast the foam liner within the shell. One crucial component of this new approach is the removal of solvent from the ablator shells without collapsing the ultralow-density porous polymer network. In this work, we report on a supercritical drying approach with liquid carbon dioxide that provides critical information on how to produce thin layers of low-density polymer foams in ablator shells for ICF experiments. Diffusion experiments were used to study the time required for complete solvent exchange in 2-mm-inner-diameter diamond shells and the data were used to demonstrate the fabrication of uniform porous polymer films inside ablator shells.

36 MATERIALS SCIENCE↗

Refining Methods to Determine the Isotopic Composition of Uranium Particles by Laser Ablation MC-ICP-MS

We report on efforts to mitigate the generation of isotopic anomalies during the ablation of micrometer-sized uranium oxide particles and analysis by MC-ICP-MS. The results of testing on particles of U200 indicate that laser fluence and frequency can affect isotopic data produced by laser ablation, but no settings were tested that could eradicate the signal spiking effect and generation of anomalous isotopic data for 234U/238U and 236U/238U. These anomalies are more frequent in samples with higher 235U enrichments, which is expected given their higher abundances of 234U and 236U. Of the standards tested here, only U005-A was anomaly-free. Efforts to compare the laser traces for particles with normal and anomalous isotopic compositions showed subtle differences in the behavior of the 234U/238U and 236U/238U ratios. However, it would be challenging to identify anomalous data points from a population of unknowns using this distinction, i.e., this is unlikely to be diagnostic. Thus, using current analytical hardware, we cannot eradicate the signal spiking phenomenon and cannot unambiguously identify isotopic anomalies from laser ablation traces. Ultimately, laser ablation ICP-MS would either require dramatic improvement to the ablation process and generation of more homogenous aerosols and/or improvements to detector electronics to identify and correct for the spiking phenomenon. Even if the reliability of the technique could be improved, a broader question to address is whether current data quality is of a high enough standard for laser ablation MC-ICP-MS to be used as a complementary technique to LG-SIMS for Safeguards.

organic↗

Thermal performance of 625-kg/cu m elastomeric ablative materials on spherically blunted 0.44-radian cones

Spherically blunted 0.44-radian (25 deg) half-angle conical models coated with elastomeric ablative materials were tested in supersonic arc-heated wind tunnels to evaluate performance of the ablators over a range of conditions typical of lifting entry. Four test conditions were combinations of stagnation point-heat transfer rates of 2.3 and 4.5 MW/m2 and stagnation pressures of 20 and 2kN/m2. Afterbody values of heat transfer rate and pressure were 0.05 to 0.20 of stagnation point values. Stagnation enthalpy varied from 4.4 to 25 MJ/kg (1900 to 11000 Btu/lbm) and free-stream Mach number was in a range from 3.5 to 4. Ablative materials retained the spherical nose shape throughout tests at the lower heat transfer level, but receded, assuming a flattened nose shape, during tests at the high heat transfer level. The residue layer that formed on the conical after-body was weak, friable, and extensively cracked. The reference ablative material, which contained phenolic microspheres, generally retained the conical shape on the model afterbody. However, a modified ablator, in which phenolic microspheres were replaced with silica microspheres, deformed and separated from the undegraded material, and thereby produced a very uneven surface. Substrate temperatures and ablator recession were in good agreement with values computed by a numerical analysis.

Champman, A. J.↗

Graphite and ablative material response to CO2 laser, carbon-arc, and xenon-arc radiation

The behavior was investigated of graphite and several charring ablators in a variety of high-radiative heat-flux environments. A commercial-grade graphite and nine state-of-the-art charring ablators were subjected to various radiative environments produced by a CO2 laser and a carbon arc. Graphite was also tested in xenon-arc radiation. Heat-flux levels ranged from 10 to 47 MW/sq m. Tests were conducted in air, nitrogen, helium, and a CO2-N2 mixture which simulated the Venus atmosphere. The experimental results were compared with theoretical results obtained with a one-dimensional charring-ablator analysis and a two-dimensional subliming-ablator analysis. Neither the graphite nor the charring ablators showed significant differences in appearance or microstructure after testing in the different radiative environments. The performance of phenolic nylon and graphite was predicted satisfactorily with existing analyses and published material property data. Good agreement between experimental and analytical results was obtained by using sublimation parameters from a chemical nonequilibrium analysis of graphite sublimation. Some charring ablators performed reasonably well and could withstand radiative fluxes of the level encountered in certain planetary entries. Other materials showed excessive surface recession and/or large amounts of cracking and spalling, and appear to be unsuitable for severe radiative environments.

Brewer, W. D.↗

Analysis of ablation debris from natural and artificial iron meteorites

Artificial ablation studies were performed on iron and nickel-iron samples using an arc-heated plasma of ionized air. Experiment conditions simulated a meteoroid traveling about 12 km/sec at an altitude of 70 km. The artificially produced fusion crusts and ablation debris show features very similar to natural fusion crusts of the iron meteorites Boguslavka, Norfork, and N'Kandhla and to magnetic spherules recovered from Mn nodules. X-ray diffraction, electron microprobe, optical, and scanning electron microscope analyses reveal that important mineralogical, elemental, and textural changes occur during ablation. Some metal is melted and ablated. The outer margin of the melted rind is oxidized and recrystallizes as a discontinuous crust of magnetite and wustite. Adjacent to the oxidized metallic ablation zone is an unoxidized metallic ablation zone in which structures such as Widmannstatten bands are obliterated as the metal is transformed to unequilibrated alpha 2 nickel-iron. Volatile elements are vaporized and less volatile elements undergo fractionation.

Blanchard, M. B.↗

An assessment of the readiness of ablative materials for preflight application to the shuttle orbiter

The shuttle orbiter relies primarily on a reusable surface insulation (RSI) thermal protection system (TPS). The RSI is very efficient in its thermal performance; however, the RSI tile system has shown poor mechanical integrity. The state-of-the-art of the ablative TPS is reviewed, and an assessment made of the ablator's readiness for use on the shuttle orbiter. Unresolved technical issues with regard to the ablative TPS are identified. Short time, highly focused analytical and experimental programs were initiated to: (1) identify candidate ablation materials; (2) assess the data base for these materials; (3) evaluate the need and kind of waterproof coating; (4) calculate thermal and other stresses in an ablator tile; (5) identify an acceptable ablator/RSI tile joint filler; and (6) assess the sensitivity of the ablator to sequential heat pulses. Results from some of these programs are discussed.

Tompkins, S. S.↗

An evaluation of ablative materials for a lunar transfer vehicle aerobrake

An evaluation of the utility of an ablative thermal protection system (TPS) for use on a lunar mission return aerobrake has been completed. Requirements are established and criteria developed specifically for the ablator application. A quantitative and qualitative multi-attribute utility analysis is employed to establish a relative ranking among candidates and a performance threshold. A review of the applicable existing ablator material database is made and appropriate thermochemical/melting ablation analysis is employed to evaluate thermal performance. Ablatives are shown to be potentially both performance capable and cost effective in single-use roles. Reusable surface insulation is also shown to be competitive as an ablator with certain modifications.

Lane, J. G.↗

Aerothermodynamic Analysis of Stardust Sample Return Capsule with Coupled Radiation and Ablation

An aerothermodynamic analysis of the forebody aeroshell of the Stardust Sample Return Capsule is carried out by using the axisymmetric viscous shock-layer equations with and without fully coupled radiation and ablation. Formulation of the viscous shock-layer equations with shoulder radius as the length scale and implementation of the Vigneron pressure condition allow resolution of the flowfield over the shoulder. With a predominantly supersonic outflow over the shoulder, a globally iterated solution or viscous shock-layer equations can be obtained. The stagnation-point results are obtained along a specified trajectory, whereas detailed calculations along the body are provided at the peak-heating point. The equilibrium calculations with ablation injection are the focus of the present study because of the lack of a general chemical nonequilibrium analysis that accounts for both surface and flowfield effect. The equilibrium calculations also provide a simple way to conserve surface (and flowfield) elemental composition for the current small ablation injection rates, where the surface elemental composition is a mixture of freestream and ablator elements. Therefore, the coupled laminar and turbulent flow solutions with radiation and ablation are obtained by using the equilibrium flow chemistry, whereas a nonequilibrium chemistry model is used for solutions without ablation and turbulence. Various computed results are compared with those obtained by the other researchers.

Gupta, Roop N.↗

Laser ablation of persistent twist cells in Drosophila: muscle precursor fate is not segmentally restricted

In Drosophila the precursors of the adult musculature arise during embryogenesis. These precursor cells have been termed Persistent Twist Cells (PTCs), as they continue to express the transcription factor Twist after that gene ceases expression elsewhere in the mesoderm. In the larval abdomen, the PTCs are associated with peripheral nerves in stereotypic ventral, dorsal, and lateral clusters, which give rise, respectively, to the ventral, dorsal, and lateral muscle fiber groups of the adult. We tested the developmental potential of the PTCs by using a microbeam laser to ablate specific clusters in larvae. We found that the ablation of a single segmental PTC cluster does not usually result in the deletion of the corresponding adult fibers of that segment. Instead, normal or near normal numbers of adult fibers can form after the ablation. Examination of pupae following ablation showed that migrating PTCs from adjacent segments are able to invade the affected segment, replenishing the ablated cells. However, the ablation of homologous PTCs in multiple segments does result in the deletion of the corresponding adult muscle fibers. These data indicate that the PTCs in an abdominal segment can contribute to the formation of muscle fibers in adjacent abdominal segments, and thus are not inherently restricted to the formation of muscle fibers within their segment of origin.

NASA Discipline Neuroscience↗

Ablative Rocket Deflector Testing and Computational Modeling

A deflector risk mitigation program was recently conducted at the NASA Stennis Space Center. The primary objective was to develop a database that characterizes the behavior of industry-grade refractory materials subjected to rocket plume impingement conditions commonly experienced on static test stands. The program consisted of short and long duration engine tests where the supersonic exhaust flow from the engine impinged on an ablative panel. Quasi time-dependent erosion depths and patterns generated by the plume impingement were recorded for a variety of different ablative materials. The erosion behavior was found to be highly dependent on the material s composition and corresponding thermal properties. For example, in the case of the HP CAST 93Z ablative material, the erosion rate actually decreased under continued thermal heating conditions due to the formation of a low thermal conductivity "crystallization" layer. The "crystallization" layer produced near the surface of the material provided an effective insulation from the hot rocket exhaust plume. To gain further insight into the complex interaction of the plume with the ablative deflector, computational fluid dynamic modeling was performed in parallel to the ablative panel testing. The results from the current study demonstrated that locally high heating occurred due to shock reflections. These localized regions of shock-induced heat flux resulted in non-uniform erosion of the ablative panels. In turn, it was observed that the non-uniform erosion exacerbated the localized shock heating causing eventual plume separation and reversed flow for long duration tests under certain conditions. Overall, the flow simulations compared very well with the available experimental data obtained during this project.

Allgood, Daniel C.↗

Ablation, Thermal Response, and Chemistry Program for Analysis of Thermal Protection Systems

In previous work, the authors documented the Multicomponent Ablation Thermochemistry (MAT) and Fully Implicit Ablation and Thermal response (FIAT) programs. In this work, key features from MAT and FIAT were combined to create the new Fully Implicit Ablation, Thermal response, and Chemistry (FIATC) program. FIATC is fully compatible with FIAT (version 2.5) but has expanded capabilities to compute the multispecies surface chemistry and ablation rate as part of the surface energy balance. This new methodology eliminates B' tables, provides blown species fractions as a function of time, and enables calculations that would otherwise be impractical (e.g. 4+ dimensional tables) such as pyrolysis and ablation with kinetic rates or unequal diffusion coefficients. Equations and solution procedures are presented, then representative calculations of equilibrium and finite-rate ablation in flight and ground-test environments are discussed.

Milos, Frank S.↗

Laser Ablation Surface Treatment of Structural Aerospace Composites and Metal Alloys for Adhesive Bonding

NASA Langley Research Center (LaRC) has been involved over the past decade in the development of laser ablation as a method to surface treat aerospace structural fiber reinforced composites (CFRPs) and metal alloys. [1- 18] Laser surface treatment has been shown to be a rapid, high precision, and reproducible method for surface treatment of these materials, and is amenable to automation. The laser ablation process removes surface contamination such as silicones, creates surface roughness, and chemically activates a surface for bonding. The degree of ablation is controllable by adjusting laser parameters. In the case of CFRPs, ablation can be performed without damage to any underlying carbon fibers. In the case of metal alloys, ablation is possible without surface embrittlement, heat damage or creation of undesirable grain structures or morphologies. The optimum laser treatment conditions are substrate dependent and generally are influenced by laser wavelength and pulse duration (typically fixed for a laser system), and laser power. In the case of metal alloys such as Ti-6Al-4V, the laser ablation process eliminates the need for several steps of the conventional processes, including hydrofluoric (HF) acid and caustic treatment. These steps are often conducted in dip tanks and require costly facilities and environmentally unfriendly liquids. In addition, the laser can create nano-porosity on the Ti-6Al-4V alloy surface allowing for sol-gel penetration and thereby creating a gradient interface with improved temperature and mechanical performance. NASA LaRC has also been involved with the development of in-line characterization methods compatible with the laser treatment process to rapidly determine the presence of key contaminates such as silicones that, even at very low concentrations, are a threat to adhesive bonding. A spectroscopic technique called micro-laser induced breakdown spectroscopy (u-LIBS) has been developed to rapidly detect silicones at concentrations below those known to cause bonding problems. This technique requires no sample preparation, vacuum or inert atmosphere, has no practical size limitations, and provides nearly instantaneous feedback to the operator. This presentation will give an overview and update of these developments with specific examples highlighted.

Connell, John W.↗

Analytical model of low and high ablation regimes in carbon arcs

Graphite ablation by an electric arc or a laser/solar flux is widely used for the synthesis of carbon nanomaterials. Previously, it was observed in multiple arc experiments that the ablation rate is a strong nonlinear function of the arc current and it drastically increases at some threshold current. As such, we developed an analytical model explaining this transition in the rate of ablation by an electric arc or a laser/solar flux. The model not only explains the observations but can also accurately predict the experimentally observed ablation rates. The model takes into account redeposition of carbon back to the ablated surface, which is the key process responsible for the observed effects.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Haemorrhagic Complications and Symptomatic Venous Thromboembolism in Interventional Tumour Ablations: The Impact of Peri-interventional Thrombosis Prophylaxis

AimThe aim of this study was to assess the rates of haemorrhagic and thrombotic complications in patients undergoing interventional tumour ablation with and without peri-interventional low-molecular-weight heparin (LMWH) thrombosis prophylaxis.MethodsPatients presented with primary and secondary neoplastic lesions in the liver, lung, kidney, lymph nodes and other locations. A total of 781 tumour ablations (radiofrequency ablation, n = 112; interstitial brachytherapy, n = 669) were performed in 446 patients over 22 months; 260 were conducted under peri-interventional thrombosis prophylaxis with LMWH (H-group;) and 521 without this (NH-group, in 143 of these, LMWH was given post-interventionally).ResultsSixty-three bleeding events occurred. There were significantly more bleedings in the H-group than in the NH-group (all interventions, 11.66 and 6.26 %, p = 0.0127; liver ablations, 12.73 and 7.1 %, p = 0.0416). The rate of bleeding events Grade ≥ III in all procedures was greater by a factor of >2.6 in the H-group than in the NH-group (4.64 and 1.73 %, p = 0.0243). In liver tumour ablations, the corresponding factor was about 3.3 (5.23 and 1.54 %, p = 0.028). In uni- and multivariate analyses including covariates, the only factor constantly and significantly associated with the rate of haemorrhage events was peri-interventional LMWH prophylaxis. Only one symptomatic lung embolism occurred in the entire cohort (NH-group). The 30- and 90-day mortalities were significantly greater in the H-group than in the NH-group.ConclusionsPeri-interventional LMWH thrombosis prophylaxis should be considered with caution. The rate of clinically relevant thrombotic events was extremely low.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser Guidance in C-Arm Cone-Beam CT-Guided Radiofrequency Ablation of Osteoid Osteoma Reduces Fluoroscopy Time

PurposeTo assess whether laser guidance can reduce fluoroscopy and procedure time of cone-beam computed tomography (CBCT)-guided radiofrequency (RF) ablations of osteoid osteoma compared to freehand CBCT guidance.Materials and Methods32 RF ablations were retrospectively analyzed, 17 laser-guided and 15 procedures using the freehand technique. Subgroup selection of 18 ablations in the hip–pelvic region with a similar degree of difficulty was used for a direct comparison. Data are presented as median (ranges).ResultsComparison of all 32 ablations resulted in fluoroscopy times of 365 s (193–878 s) for freehand and 186 s (75–587 s) for laser-guided procedures (p = 0.004). Corresponding procedure times were 56 min (35–97 min) and 52 min (30–85 min) (p = 0.355). The subgroup showed comparable target sizes, needle path lengths, and number of scans between groups. Fluoroscopy times were lower for laser-guided procedures, 215 s (75–413 s), compared to 384 s (193–878 s) for freehand (p = 0.012). Procedure times were comparable between groups, 51 min (30–72 min) for laser guidance and 58 min (35–79 min) for freehand (p = 0.172).ConclusionAdding laser guidance to CBCT-guided osteoid osteoma RF ablations significantly reduced fluoroscopy time without increasing procedure time.Level of EvidenceLevel 4, case series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hydrodissection of the Gallbladder Bed: A Technique for Ablations Located Close to the Gallbladder

Objective: To report the technique of hydrodissection of the gallbladder bed, in order to separate the gallbladder wall from the liver surface during microwave ablation of liver malignancies located in segment V. Materials and Methods: Between January 2018 and March 2018, percutaneous hydrodissection of the gallbladder fossa was performed during four microwave ablation procedures in three patients (One patient was treated twice for the same lesion, making a total of four procedures for three lesions.) All treated lesions were located in segment V and abutting the gallbladder. Number of hydrodissection needles, volume of hydrodissection, repartition of hydrodissection, separation of tumour from the gallbladder post-hydrodissection, technical success of hydrodissection/ablation, and complications were recorded and evaluated. Results: Hydrodissection of the gallbladder fossa was technically feasible in all four procedures, and microwave ablation was performed at maximum power without any early interruption. Time to perform hydrodissection was 11.3 min on average (range 7–18 min). Minimal distance between the ablation area and the GB increased from virtual to 10 mm on average (range 6–13), with a mean volume of dissection of 65 ml (range 40–100). Technical success was 75%. There was no complication related to the hydrodissection itself, and no acute or delayed gallbladder complication. Conclusion: Hydrodissection of the gallbladder bed is a feasible technique to separate the gallbladder from the liver surface. This could potentially decrease the risk of thermal injuries to the gallbladder wall when ablating tumours located in segment V.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Internal Energy Distributions of Ions Created by Electrospray Ionization and Laser Ablation-Liquid Vortex Capture-Electrospray Ionization

Recently a number of techniques have combined laser ablation with liquid capture for mass spectrometry spot sampling and imaging applications. The newly developed non-contact liquid-vortex capture probe has been used to efficiently collect 355 nm UV laser ablated material in a continuous flow solvent stream in which the captured material dissolves and then undergoes electrospray ionization. This sampling and ionization approach has produced what appear to be classic electrospray ionization spectra; however, the softness of this sampling/ionization process versus simple electrospray ionization has not been definitely determined. A series of benzlypyridinium salts, known as thermometer ions, were used to compare internal energy distributions between electrospray ionization and the UV laser ablation liquid-vortex capture probe electrospray combination. Measured internal energy distributions were identical between the two techniques, even with differences in laser fluence (0.7-3.1 J cm-2) and when using UV-absorbing or non-UV-absorbing sample substrates. This data indicates ions formed directly by UV laser ablation, if any, are likely an extremely small constituent of the total ion signal observed. Instead, neutral molecules, clusters or particulates ejected from the surface during laser ablation, subsequently captured and dissolved in the flowing solvent stream then electrosprayed are the predominant source of ion signal observed. The electrospray ionization process used controls the softness of the technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Simple Method for Improving the Spatial Resolution in Infrared Laser Ablation Mass Spectrometry Imaging

In mass spectrometry imaging of tissues, the size of structures that can be distinguished is determined by the spatial resolution of the imaging technique. Here, the spatial resolution of IR laser ablation is markedly improved by increasing the distance between the laser and the focusing lens. As the distance between the laser and the lens is increased from 1 to 18 m, the ablation spot size decreases from 440 to 44 μm. This way, only the collimated center of the divergent laser beam is directed on the focusing lens, which results in better focusing of the beam. Part of the laser energy is lost at longer distance, but this is compensated by focusing of the radiation to a smaller area on the sample surface. The long distance can also be achieved by a set of mirrors, between which the radiation travels before it is directed to the focusing lens and the sample. This method for improving the spatial resolution can be utilized in mass spectrometry imaging of tissues by techniques that utilize IR laser ablation, such as laser ablation electrospray ionization, laser ablation atmospheric pressure photoionization, and matrix-assisted laser desorption electrospray ionization. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗