Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Wave Tank”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Hamiltonian discontinuous Galerkin FEM for linear, rotating incompressible Euler equations: Inertial waves

A discontinuous Galerkin finite element method (DGFEM) has been developed and tested for the linear, three-dimensional, rotating incompressible Euler equations. These equations admit complicated wave solutions, which poses numerical challenges. These challenges concern: (i) discretisation of a divergence-free velocity field; (ii) discretisation of geostrophic boundary conditions combined with no-normal flow at solid walls; (iii) discretisation of the conserved, Hamiltonian dynamics of the inertial-waves; and, (iv) large-scale computational demands owing to the three-dimensional nature of inertial-wave dynamics and possibly its narrow zones of chaotic attraction. These issues have been resolved, for example: (i) by employing Dirac’s method of constrained Hamiltonian dynamics to our DGFEM for linear, compressible flows, thus enforcing the incompressibility constraints; (ii) by enforcing no-normal flow at solid walls in a weak form and geostrophic tangential flow along the wall; and, (iii) by applying a symplectic time discretisation. We compared our simulations with exact solutions of three-dimensional incompressible flows, in (non) rotating periodic and partly periodic cuboids (Poincaré waves). Additional verifications concerned semi-analytical eigenmode solutions in rotating cuboids with solid walls. Finally, a simulation in a tilted rotating tank, yielding more complicated wave dynamics, demonstrates the potential of our new method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonlinear Slosh Damping Testing and Analysis for Launch Vehicle Propellant Tanks

Propellant tank slosh damping models for launch vehicle ascent analysis typically employ linear models for bare-wall damping, or assume a single, low-amplitude wave height for baffled configurations. A higher fidelity damping model would incorporate nonlinear effects to increase damping as slosh wave amplitude increases. This paper provides an overview of a technical assessment performed by the NASA Engineering and Safety Center (NESC) to evaluate lateral slosh damping as a function of lateral force (or wave) amplitude for multiple tank configurations. The increased fidelity of nonlinear slosh damping models, if leveraged, has the potential to reduce over-conservatism associated with the use of linear slosh damping models. This can provide design flexibility to enhance launch vehicle flight control performance, reduce baffle design requirements and/or increase robustness in targeted areas such as control-structure interaction during ascent.

Tannen S VanZwieten↗

A compact mechanical power take-off for wave energy converters: Design, analysis, and test verification

Power Take-off (PTO) is one of the most critical components in the ocean wave conversion. This paper introduces an innovative compact mechanical PTO using a ball screw mechanism and a Mechanical Motion Rectifier (MMR) to improve the energy conversion performance. The proposed MMR PTO converts bidirectional oscillatory motion of the ocean waves into unidirectional rotation. The detailed design and working principle of the MMR PTO are explicitly explained. Dynamic analysis is presented for the three most important factors that influence the performance, including the equivalent mass, the equivalent damping, and the excitation frequency. The analytical relationship between these factors and the disengaged freewheeling motion caused by the MMR mechanism is derived, and the analytical solution is verified through dry lab testing. Experimental results in bench tests show that compared with the traditional linear PTO which use the ball screw to drive the generator directly, the MMR PTO is more efficient because of the unique freewheeling motion, achieving a maximum 81.2% energy transfer efficiency. After integrating the prototype PTO with a single-body point absorber type of wave energy converter, testing in a water tank yields total PTO efficiency up to 62.4%, showing a very promising potential for real applications.

16 TIDAL AND WAVE POWER↗

Dynamic gravity Probe-B spacecraft due to gravity jitter induced cryogenic helium disturbances in rotating dewar

The dynamical behavior of fluids, in particular the effect of surface tension on partially-filled rotating fluids (cryogenic liquid helium and helium vapor) in a full scale Gravity Probe-B Spacecraft propellant dewar tank imposed by various frequencies of gravity jitters have been investigated. The study shows that slosh waves excited inside the spacecraft propellant tank are characterized by the lowest frequency of the waves initiated, frequencies of the gravity jitters imposed on the propellant system, the levels of background gravity environment, and dewar rotating speeds. Conditions for suppression and amplification of the slosh waves are discussed. It also shows that fluid stress distribution exerted on the walls of the rotating dewar are closely related to the characteristics of slosh waves excited on the liquid-vapor interface in the rotating dewar tank. This can provide a set of data leading toward the control of spacecraft imbalance caused by the uneven fluid stress distribution from slosh waves.

Hung, R. J.↗

Washington Air-Sea Interaction Research Facility Waves and Currents Test Data

This archive includes data from the University of Washington WASIRF (Washington Air-Sea Interaction Research Facility) flume. WASIRF is a laboratory testing tank at the Northwest National Marine Renewable Energy Center designed to investigate wind-wave-current interactions. It includes test data for simultaneous waves and current generation done at the WASIRF lab. A report included in the archive further details testing methodology. Wave and current data is provided in .dat files.

16 TIDAL AND WAVE POWER↗

High Resolution Millimeter Wave Detection of Vertical Cracks in the Space Shuttle External Tank Spray-On-Foam Insulation (SOFI)

Space Shuttle Columbia s catastrophic failure, the separation of a piece of spray-on-foam insulation (SOFI) from the external tank (ET) in the Space Shuttle Discovery s flight in 2005 and crack detected in its ET foam prior to its successful launch in 2006 emphasize the need for effective nondestructive methods for inspecting the shuttle ET SOFI. Millimeter wave nondestructive testing methods have been considered as potential and effective inspection tools for evaluating the integrity of the SOFI. This paper presents recent results of an investigation for the purpose of detecting vertical cracks in SOFI panels using a focused millimeter wave (150 GHz) reflectometer. The presented images of the SOFI panels show the capability of this reflectometer for detecting tight vertical cracks (also as a function of crack opening dimension) in exposed SOFI panels and while covered by a piece of SOFI ramp simulating a more realistic and challenging situation.

Kharkovsky, S.↗

High-Resolution Millimeter Wave Detection of Vertical Cracks in the Space Shuttle External Tank (ET) Spray-on-Foam Insulation (SOFI)

Space Shuttle Columbia's catastrophic failure has been attributed to a piece of spray-on-foam insulation (SOFI) that was dislodged from the external tank (ET) and struck the leading edge of the left wing. A piece of SOFI was also dislodged in the Space Shuttle Discovery's flight in 2005 and recently a crack was detected in its ET foam prior to its successful launch. Millimeter wave nondestructive testing methods have been considered as potential effective inspection tools for evaluating the integrity of the SOFI. Recently, in a specific investigation into the potential of these methods for detecting vertical cracks in SOFI was explored using a focused millimeter wave reflectometer at 150 GHz. The results showed the capability of these methods for detecting tight vertical cracks (also as a function of crack opening dimension) in exposed SOFI panels and while covered by a piece of SOFI ramp simulating a more realistic and challenging situation. Some crack-like anomalies were also detected in a blind SOFI panel. This paper presents the background for these techniques as well as representative images of the vertical crack in the SOFI panel, crack-like anomalies in the blind panel and a discussion of the practical attributes of these inspection methods.

Kharkovsky, S.↗

Progress on Advancing the Robotic Air-slot Volumetric Inspection System (RAVIS) for Hanford Under-tank Inspection - 20519

The 27 in-service double-shell tank (DST) systems at Hanford provide interim storage for nearly 56 million gallons of nuclear and hazardous chemical legacy waste. The safe and reliable storage of the waste is critical to the site's extended cleanup mission. While in service, the leak integrity of the DSTs must be demonstrated to satisfy the Washington Administrative Code, inform decisions on tank management, and gauge fitness for continued service beyond originally intended design lives. The carbon steel plates and welds that comprise DST primary tank sidewalls and lower knuckles are routinely 'sampled' for volumetric non-destructive testing using ultrasonic inspection technology to determine whether corrosion pitting, cracking, or general corrosion are occurring that could compromise tank leak integrity. However, the carbon steel plates and welds that comprise the bottoms of primary tanks have not been thoroughly inspected since the DSTs were constructed (i.e., since 1968-1986) due to limited physical access to the exterior tank bottoms. The Robotic Air-slot Volumetric Inspection System, or 'RAVIS,' is being engineered to overcome the challenge of tank bottom in-service inspection. The system will be deployed under primary tanks within the small cooling channels/air-slots in the refractory pads upon which the tanks rest and will use ultrasonic guided wave inspection technology to volumetrically inspect physically inaccessible regions that make up ∼90% of a tank bottom, as well as regions that are physically accessible from the air-slots but comprise only ∼10% of a tank bottom. This paper describes the air-slot sensor and robotic deployment system and focuses on the testing approach and methods that are being applied to support (1) design feedback and performance acceptance (requirement verification) and (2) performance repeatability/reliability assessments (qualification) to ensure the RAVIS is prepared for successful inservice inspections of primary tank bottoms. Test progress made against the test plan, the results of 2019 testing, and the future outlook are included. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Biofouling Analysis for Wave Energy Piston Design: Post-Access Test Report

This report summarizes the purpose, procedures, results, and conclusions of prolonged seawater tank testing of a prototype wave energy converter apparatus. Test objectives included determination of the effectiveness of a biofouling mitigation element in one test assembly compared to a control, and system force over many cycles of actuation over months.

16 TIDAL AND WAVE POWER↗

Analytical Solutions for Seismic Fluid-Structure Interaction of Head-Supported Cylindrical Tanks

Fluid-structure interaction (FSI) of earthquake shaking is a design consideration in the civil, nuclear, chemical, and mechanical industries. Preliminary sizing of structures and components in these industries will often use analytical solutions because there is insufficient information to warrant the analysis of numerical models. Here, this study extends prior analytical work on seismic FSI of base-supported tanks in the 1980s to accommodate head-supported tanks with geometries similar to those proposed for new-build, liquid (fluid)-filled, advanced reactors. Analytical solutions are derived for flexible, head-supported, cylindrical tanks subjected to small-amplitude, unidirectional, horizontal seismic motion, and address frequencies of lateral motions of the tank, hydrodynamic pressures, frequencies of waves, wave heights, and reactions at the head support. Solutions are presented for a range of tank dimensions and could be used for a) preliminary design of head-supported cylindrical tanks and their supporting structures with idealized seismic input, and b) verification of numerical models to be used for final seismic analysis, design, and probabilistic risk assessment.

42 ENGINEERING↗

Ultrasonic power measurement system based on acousto-optic interaction

Ultrasonic waves are widely used, with applications including the medical, military, and chemical fields. However, there are currently no effective methods for ultrasonic power measurement. Previously, ultrasonic power measurement has been reliant on mechanical methods such as hydrophones and radiation force balances. This paper deals with ultrasonic power measurement based on an unconventional method: acousto-optic interaction. Compared with mechanical methods, the optical method has a greater ability to resist interference and also has reduced environmental requirements. Therefore, this paper begins with an experimental determination of the acoustic power in water contained in a glass tank using a set of optical devices. Because the light intensity of the diffraction image generated by acousto-optic interaction contains the required ultrasonic power information, specific software was written to extract the light intensity information from the image through a combination of filtering, binarization, contour extraction, and other image processing operations. The power value can then be obtained rapidly by processing the diffraction image using a computer. The results of this work show that the optical method offers advantages that include accuracy, speed, and a noncontact measurement method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, Optimization, and Control of Floating Offshore Wind Farms for Optimal Energy Production (Final report)

The uncertainty and irregularity of ocean waves and the ocean environment is a major factor in the development of commercial scale floating wind turbines as the operation of floating structures in such an environment can lead to irregular and unpredictable loading, fatigue, and ultimately a reduction in the operational life of the turbine system which affects energy production over the lifetime of the turbine. Control solutions that can limit float motions and mitigate stressful events on the structure become essential for extending lifetime and limiting the operational uncertainty of a floating wind turbine. Digital twins are computational replicas of physical systems that operate in parallel with the operation of the physical system. Given advanced knowledge of a systems input, digital twins have the ability to predict the behavior of a system in advance, which can be valuable in the control of that system. In this project, we developed and assessed potential digital twin models developed in house and openly available (OpenFast) for use in the real time control of the six degree of freedom response motions of a floating wind turbine in ocean waves. Coupling these models with near-field real time irregular sea surface (wve) measurement/sensings and prediction models, we used the digital twin to predict how the floating turbine will respond to the incoming waves. Applying this information to a motion control system of the float, one can limit and control float motions to prevent undesirable loading events/large angular motions, thus increasing system life and ultimately contributing to optimizing energy production. Due to the computational intensity of operating a digital twin in real time, we investigated the use of artificial intelligence techniques to speed-up the processes of the digital twin, as well as the wave reconstruction/prediction models. Model tank testing at the University of Rhode Island and University of Maine both validated and demonstrated the developed techniques on simple float geometries and a scale model of the NREL 15 MW reference turbine.

17 WIND ENERGY↗

The effects of forced small-wavelength, finite-bandwidth initial perturbations and miscibility on the turbulent Rayleigh–Taylor instability

Rayleigh–Taylor instability experiments are performed using both immiscible and miscible incompressible liquid combinations having a relatively large Atwood number of $A\equiv ({\it\rho}_{2}-{\it\rho}_{1})/({\it\rho}_{2}+{\it\rho}_{1})=0.48$ . The liquid-filled tank is attached to a test sled that is accelerated downwards along a vertical rail system using a system of weights and pulleys producing approximately $1g$ net acceleration. The tank is backlit and images are digitally recorded using a high-speed video camera. The experiments are either initiated with forced initial perturbations or are left unforced. The forced experiments have an initial perturbation imposed by vertically oscillating the liquid-filled tank to produce Faraday waves at the interface. The unforced experiments rely on random interfacial fluctuations, resulting from background noise, to seed the instability. The main focus of this study is to determine the effects of forced initial perturbations and the effects of miscibility on the growth parameter, ${\it\alpha}$ . Measurements of the mixing-layer width, $h$ , are acquired, from which ${\it\alpha}$ is determined. It is found that initial perturbations of the form used in this study do not affect measured ${\it\alpha}$ values. However, miscibility is observed to strongly affect ${\it\alpha}$ , resulting in a factor of two reduction in its value, a finding not previously observed in past experiments. In addition, all measured ${\it\alpha}$ values are found to be smaller than those obtained in previous experimental studies.

42 ENGINEERING↗

ANNUAL RADIOACTIVE WASTE TANK INSPECTION PROGRAM 2010

Aqueous radioactive wastes from Savannah River Site (SRS) separations and vitrification processes are contained in large underground carbon steel tanks. Inspections made during 2010 to evaluate these vessels and other waste handling facilities along with evaluations based on data from previous inspections are the subject of this report. The 2010 inspection program revealed that the structural integrity and waste confinement capability of the Savannah River Site waste tanks were maintained. All inspections scheduled per SRR-LWE-2009-00138, HLW Tank Farm Inspection Plan for 2010, were completed. Ultrasonic measurements (UT) performed in 2010 met the requirements of C-ESG-00006, In-Service Inspection Program for High Level Waste Tanks, Rev. 3, and WSRC-TR-2002-00061, Rev.6. UT inspections were performed on Tanks 30, 31 and 32 and the findings are documented in SRNL-STI-2010-00533, Tank Inspection NDE Results for Fiscal Year 2010, Waste Tanks 30, 31 and 32. A total of 5824 photographs were made and 1087 visual and video inspections were performed during 2010. Ten new leaksites at Tank 5 were identified in 2010. The locations of these leaksites are documented in C-ESR-G-00003, SRS High Level Waste Tank Leaksite Information, Rev.5. Ten leaksites at Tank 5 were documented during tank wall/annulus cleaning activities. None of these new leaksites resulted in a release to the environment. The leaksites were documented during wall cleaning activities and the waste nodules associated with the leaksites were washed away. Previously documented leaksites were reactivated at Tank 12 during waste removal activities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Annual Radioactive Waste Tank Inspection Program - 2011

Aqueous radioactive wastes from Savannah River Site (SRS) separations and vitrification processes are contained in large underground carbon steel tanks. Inspections made during 2011 to evaluate these vessels and other waste handling facilities along with evaluations based on data from previous inspections are the subject of this report. The 2011 inspection program revealed that the structural integrity and waste confinement capability of the Savannah River Site waste tanks were maintained. All inspections scheduled per SRR-LWE-2011-00026, HLW Tank Farm Inspection Plan for 2011, were completed. Ultrasonic measurements (UT) performed in 2011 met the requirements of C-ESR-G-00006, In-Service Inspection Program for High Level Waste Tanks, Rev. 3, and WSRC-TR-2002-00061, Rev.6. UT inspections were performed on Tanks 25, 26 and 34 and the findings are documented in SRNL-STI-2011-00495, Tank Inspection NDE Results for Fiscal Year 2011, Waste Tanks 25, 26, 34 and 41. A total of 5813 photographs were made and 835 visual and video inspections were performed during 2011. A potential leaksite was discovered at Tank 4 during routine annual inspections performed in 2011. The new crack, which is above the allowable fill level, resulted in no release to the environment or tank annulus. The location of the crack is documented in C-ESR-G-00003, SRS High Level Waste Tank Leaksite Information, Rev.6.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ANNUAL RADIOACTIVE WASTE TANK INSPECTION PROGRAM 2009

Aqueous radioactive wastes from Savannah River Site (SRS) separations and vitrification processes are contained in large underground carbon steel tanks. Inspections made during 2009 to evaluate these vessels and other waste handling facilities along with evaluations based on data from previous inspections are the subject of this report. The 2009 inspection program revealed that the structural integrity and waste confinement capability of the Savannah River Site waste tanks were maintained. All inspections scheduled per LWO-LWE-2008-00423, HLW Tank Farm Inspection Plan for 2009, were completed. All Ultrasonic measurements (UT) performed in 2009 met the requirements of C-ESG-00006, In-Service Inspection Program for High Level Waste Tanks, Rev. 1, and WSRC-TR-2002-00061, Rev.4. UT inspections were performed on Tank 29 and the findings are documented in SRNL-STI-2009-00559, Tank Inspection NDE Results for Fiscal Year 2009, Waste Tank 29. Post chemical cleaning UT measurements were made in Tank 6 and the results are documented in SRNL-STI-2009-00560, Tank Inspection NDE Results Tank 6, Including Summary of Waste Removal Support Activities in Tanks 5 and 6. A total of 6669 photographs were made and 1276 visual and video inspections were performed during 2009. Twenty-Two new leaksites were identified in 2009. The locations of these leaksites are documented in C-ESR-G-00003, SRS High Level Waste Tank Leaksite Information, Rev.4. Fifteen leaksites at Tank 5 were documented during tank wall/annulus cleaning activities. Five leaksites at Tank 6 were documented during tank wall/annulus cleaning activities. Two new leaksites were identified at Tank 19 during waste removal activities. Previously documented leaksites were reactivated at Tanks 5 and 12 during waste removal activities. Also, a very small amount of additional leakage from a previously identified leaksite at Tank 14 was observed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulating Vibrations in a Complex Loaded Structure

The Dynamic Response Computation (DIRECT) computer program simulates vibrations induced in a complex structure by applied dynamic loads. Developed to enable rapid analysis of launch- and landing- induced vibrations and stresses in a space shuttle, DIRECT also can be used to analyze dynamic responses of other structures - for example, the response of a building to an earthquake, or the response of an oil-drilling platform and attached tanks to large ocean waves. For a space-shuttle simulation, the required input to DIRECT includes mathematical models of the space shuttle and its payloads, and a set of forcing functions that simulates launch and landing loads. DIRECT can accommodate multiple levels of payload attachment and substructure as well as nonlinear dynamic responses of structural interfaces. DIRECT combines the shuttle and payload models into a single structural model, to which the forcing functions are then applied. The resulting equations of motion are reduced to an optimum set and decoupled into a unique format for simulating dynamics. During the simulation, maximum vibrations, loads, and stresses are monitored and recorded for subsequent analysis to identify structural deficiencies in the shuttle and/or payloads.

Cao, Tim T.↗

A Prototype Dual Robot System to Perform Ultrasonic and Visual Inspection for the Bottom of Double-Shell Tanks - 18624

Up to this point, ultrasonic inspection-based condition data has only been available for double-shell tank (DST) sidewalls because direct inspection access to the primary tank bottom is limited to vent duct channels in an insulating refractory pad that the primary tank rests on. Probe access through the air slot would provide the opportunity to get information about the condition of the bottom of the primary tank, but it is a challenge to deploy a crawling robot that is capable of performing nondestructive ultrasonic and visual inspection through confined air slots. As such, a conceptual prototype of a deployable inspection robot system to enable ultrasonic and visual inspection for DST base through ventilation ducts was designed and fabricated. This prototype dual robot system consisting of the AnnulusBot and the MouseBot can be integrated with nondestructive evaluation (NDE) sensors to inspect and examine the physical properties of the underside of DSTs to enable status assessment. The AnnulusBot was designed to carry the MouseBot and to be deployed to the annulus space through a riser. To deploy the MouseBot to every ventilation channel in the annulus, the arm consisting of a boom and a forearm was used to place the MouseBot on the underside of the tank. The AnnulusBot used segmented wheels enable to traverse pipes and other potential obstacles. The cable management system utilized motorized wheels to feed the cable into the ventilation channel. This would reduce the amount of work that the MouseBot would have to do during inspection. This feeding mechanism would also be used to retrieve the MouseBot at the end of its inspection. Additionally, if the MouseBot fails, this mechanism would be used for retrieval. Once deployed, the MouseBot navigates to the center of the tank via the air ventilation channel beneath the inner shell (the primary tank) while inspecting the space. The MouseBot is then retrieved from the channel by a combination of its own drive power and the AnnulusBot retracting the attached umbilical cord. Compare with the AnnulusBot, the physical dimensional limitations of the MouseBot were a greater challenge. As the surface state of the concrete of the air channels could have variable texture, and may contain debris, it was decided not to travel along this surface. The ceiling of these channels is carbon steel and can be utilized throughout the channel. To use this travel surface, magnetic wheels were employed. A foreseeable problem with the use of magnets on this surface, is that they would preclude the use of eddy currents sensors. However, other technologies like ultrasonic technology sensors should be unaffected. Laboratory scale test was performed on a mock-up single wedge of the refractory pad to evaluate maneuverability of the MouseBot. The electronic components for the prototype would work in the ranges of 150-185 deg. F (65.6-85 deg. C). Both the AnnulusBot and MouseBot will be subject to constant radiation. All major printed circuit board (PCB) microcontroller components were designed to be situated outside of the annulus space and inside the main control panel to avoid radiation-induced failure. As future work, electronic components including the Arduinos that used Atmel commercial microcontrollers will be replaced with the high temperature rated Atmel microcontrollers so that the robots can be operated reliably at ambient temperatures up to 200 deg. F (93.3 deg. C). In addition, the robots will be service life tested to evaluate performance at elevated temperature and under gamma irradiation. (authors)

42 ENGINEERING↗