Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WASHOUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

The release of alginate lyase from growing Pseudomonas syringae pathovar phaseolicola

Pseudomonas syringae pathovar phaseolicola, which produces alginate during stationary growth phase, displayed elevated extracellular alginate lyase activity during both mid-exponential and late-stationary growth phases of batch growth. Intracellular activity remained below 22% of the total activity during exponential growth, suggesting that alginate lyase has an extracellular function for this organism. Extracellular enzyme activity in continuous cultures, grown in either nutrient broth or glucose-simple salts medium, peaked at 60% of the washout rate, although nutrient broth-grown cultures displayed more than twice the activity per gram of cell mass. These results imply that growth rate, nutritional composition, or both initiate a release of alginate lyase from viable P. syringae pv. phaseolicola, which could modify its entrapping biofilm.

Polysaccharide-Lyases/secretion↗

Ventilation-perfusion matching in long-term microgravity

We studied the ventilation-perfusion matching pattern in normal gravity (1 G) and short- and long-duration microgravity (microG) using the cardiogenic oscillations in the sulfur hexaflouride (SF(6)) and CO(2) concentration signals during the phase III portion of vital capacity single-breath washout experiments. The signal power of the cardiogenic concentration variations was assessed by spectral analysis, and the phase angle between the oscillations of the two simultaneously expired gases was obtained through cross-correlation. For CO(2), a significant reduction of cardiogenic power was observed in microG, with respect to 1 G, but the reduction was smaller and more variable in the case of SF(6). A shift from an in-phase condition in 1 G to an out-of-phase condition was found for both short- and long-duration microG. We conclude that, although the distribution of ventilation and perfusion becomes more homogeneous in microG, significant inhomogeneities persist and that areas of high perfusion become associated with areas of relatively lower ventilation. In addition, these modifications seem to remain constant during long-term exposure to microG.

Mir Project↗

Clouds Aerosols Internal Affaires: Increasing Cloud Fraction and Enhancing the Convection

Clouds developing in a polluted environment have more numerous, smaller cloud droplets that can increase the cloud lifetime and liquid water content. Such changes in the cloud droplet properties may suppress low precipitation allowing development of a stronger convection and higher freezing level. Delaying the washout of the cloud water (and aerosol), and the stronger convection will result in higher clouds with longer life time and larger anvils. We show these effects by using large statistics of the new, 1km resolution data from MODIS on the Terra satellite. We isolate the aerosol effects from meteorology by regression and showing that aerosol microphysical effects increases cloud fraction by average of 30 presents for all cloud types and increases convective cloud top pressure by average of 35mb. We analyze the aerosol cloud interaction separately for high pressure trade wind cloud systems and separately for deep convective cloud systems. The resultant aerosol radiative effect on climate for the high pressure cloud system is: -10 to -13 W/sq m at the top of the atmosphere (TOA) and -11 to -14 W/sq m at the surface. For deeper convective clouds the forcing is: -4 to -5 W/sq m at the TOA and -6 to -7 W/sq m at the surface.

Koren, Ilan↗

Low level CO2 effects on pulmonary function in humans

The purpose of the study was to determine whether chamber exposure to low levels of CO2 results in functional alterations in gas mixing and closing volume in humans. Four healthy volunteer subjects were exposed to 0.7% CO2 and to 1.2% CO2. Spirometry, lung volumes, single breath nitrogen washout, diffusing capacity for carbon monoxide (DLCO) by two methods, and cardiac output were measured in triplicate. Values were obtained over two non-consecutive days during the training period (control) and on days 2 or 3, 4, 6, 10, 13, and 23 of exposure to each CO2 level. Measurements were made during the same time of day. There was one day of testing after exposure, while still in the chamber but off carbon dioxide. The order of testing, up until measurements of DLCO and cardiac output, were randomized to avoid presentation effects. The consistent findings were a reduction in diffusing capacity for carbon monoxide and a fall in cardiac output, occurring to a similar degree with both exposures. For the group as a whole, there was no indication of major effects on spirometry, lung volumes, gas mixing or dead space. We conclude that small changes may occur in the function of distal gas exchanging units; however, these effects were not associated with any adverse health effects. The likelihood of pathophysiologic changes in lung function or structure with 0.7 or 1.2% CO2 exposure for this period of time, is therefore, low.

NASA Discipline Cardiopulmonary↗

Cardiogenic oscillation phase relationships during single-breath tests performed in microgravity

We studied the phase relationships of the cardiogenic oscillations in the phase III portion of single-breath washouts (SBW) in normal gravity (1 G) and in sustained microgravity (microG). The SBW consisted of a vital capacity inspiration of 5% He-1.25% sulfurhexafluoride-balance O2, preceded at residual volume by a 150-ml Ar bolus. Pairs of gas signals, all of which still showed cardiogenic oscillations, were cross-correlated, and their phase difference was expressed as an angle. Phase relationships between inspired gases (e.g., He) and resident gas (n2) showed no change from 1 G (211 +/- 9 degrees) to microG (163 +/- 7 degrees). Ar bolus and He were unaltered between 1 G (173 +/- 15 degrees) and microG (211 +/- 25 degrees), showing that airway closure in microG remains in regions of high specific ventilation and suggesting that airway closure results from lung regions reaching low regional volume near residual volume. In contrast, CO2 reversed phase with He between 1 G (332 +/- 6 degrees) and microG (263 +/- 27 degrees), strongly suggesting that, in microG, areas of high ventilation are associated with high ventilation-perfusion ratio (VA/Q). This widening of the range of VA/Q in microG may explain previous measurements (G.K. Prisk, A.R. Elliott, H.J.B. Guy, J.M. Kosonen, and J.B. West J. Appl. Physiol. 79: 1290-1298, 1995) of an overall unaltered range of VA/Q in microG, despite more homogeneous distributions of both ventilation and perfusion.

Non-NASA Center↗

Multiple-breath washin of helium and sulfur hexafluoride in sustained microgravity

We performed multiple-breath washouts of N2 and simultaneous washins of He and SF6 with fixed tidal volume (approximately 1,250 ml) and preinspiratory lung volume (approximately the subject's functional residual capacity in the standing position) in four normal subjects (mean age 40 yr) standing and supine in normal gravity (1 G) and during exposure to sustained microgravity (microG). The primary objective was to examine the influence of diffusive processes on the residual, nongravitational ventilatory inhomogeneity in the lung in microG. We calculated several indexes of convective ventilatory inhomogeneity from each gas species. A normal degree of ventilatory inhomogeneity was seen in the standing position at 1 G that was largely unaltered in the supine position. When we compared the standing position in 1 G with microG, there were reductions in phase III slope in all gases, consistent with a reduction in convection-dependent inhomogeneity in the lung in microG, although considerable convective inhomogeneity persisted in microG. The reductions in the indexes of convection-dependent inhomogeneity were greater for He than for SF6, suggesting that the distances between remaining nonuniformly ventilated compartments in microG were short enough for diffusion of He to be an effective mechanism to reduce gas concentration differences between them.

NASA Discipline Cardiopulmonary↗

Gastrointestinal citrate absorption in nephrolithiasis

Gastrointestinal absorption of citrate was measured in stone patients with idiopathic hypocitraturia to determine if citrate malabsorption could account for low urinary citrate. Citrate absorption was measured directly from recovery of orally administered potassium citrate (40 mEq.) in the intestinal lavage fluid, using an intestinal washout technique. In 7 stone patients citrate absorption, serum citrate levels, peak citrate concentration in serum and area under the curve were not significantly different from those of 7 normal subjects. Citrate absorption was rapid and efficient in both groups, with 96 to 98% absorbed within 3 hours. The absorption of citrate was less efficient from a tablet preparation of potassium citrate than from a liquid preparation, probably due to a delayed release of citrate from wax matrix. However, citrate absorption from solid potassium citrate was still high at 91%, compared to 98% for a liquid preparation. Thus, hypocitraturia is unlikely to be due to an impaired gastrointestinal absorption of citrate in stone patients without overt bowel disease.

Non-NASA Center↗

Motion Cueing Algorithm Development: Human-Centered Linear and Nonlinear Approaches

While the performance of flight simulator motion system hardware has advanced substantially, the development of the motion cueing algorithm, the software that transforms simulated aircraft dynamics into realizable motion commands, has not kept pace. Prior research identified viable features from two algorithms: the nonlinear "adaptive algorithm", and the "optimal algorithm" that incorporates human vestibular models. A novel approach to motion cueing, the "nonlinear algorithm" is introduced that combines features from both approaches. This algorithm is formulated by optimal control, and incorporates a new integrated perception model that includes both visual and vestibular sensation and the interaction between the stimuli. Using a time-varying control law, the matrix Riccati equation is updated in real time by a neurocomputing approach. Preliminary pilot testing resulted in the optimal algorithm incorporating a new otolith model, producing improved motion cues. The nonlinear algorithm vertical mode produced a motion cue with a time-varying washout, sustaining small cues for longer durations and washing out large cues more quickly compared to the optimal algorithm. The inclusion of the integrated perception model improved the responses to longitudinal and lateral cues. False cues observed with the NASA adaptive algorithm were absent. The neurocomputing approach was crucial in that the number of presentations of an input vector could be reduced to meet the real time requirement without degrading the quality of the motion cues.

Houck, Jacob A.↗

Gender Consideration in Experiment Design for Airbrake in Prebreathe

If gender is a confounder of the decompression sickness (DCS) or venous gas emboli (VGE) outcomes of a proposed air break in oxygen prebreathe (PB) project, then decisions about the final experiment design must be made. We evaluated if the incidence of DCS and VGE from tests in altitude chambers over 20 years were different between men and women after resting and exercise prebreathe protocols. Nitrogen washout during PB is our primary risk mitigation strategy to prevent subsequent DCS and VGE in subjects. Bubbles in the pulmonary artery (venous blood) were detected from the precordial position using Doppler ultrasound bubble detectors. The subjects were monitored for VGE for four min at about 15 min intervals for the duration of the altitude exposure, with maximum bubble grade assigned a Spencer Grade of IV. There was no difference in DCS incidence between men and women in either PB protocol. The incidence of VGE and Grade IV VGE is statistically lower in women compared to men after resting PB. Even when 10 tests were compared with Mantel-Haenszel 2 where both men (n = 168) and women (n = 92) appeared, the p-value for VGE incidence was still significant at 0.03. The incidence of VGE and Grade IV VGE is not statistically lower in women compared to men after exercise PB. Even when six tests were compared with Mantel-Haenszel x2 where both men (n = 165) and women (n = 49) appeared, the p-value for VGE incidence was still not significant at 0.90. Our goal is to understand the risk of brief air breaks during PB without other confounding variables invalidating our conclusions. The cost to additionally account for the confounding role of gender on VGE outcome after resting PB is judged excessive. Our decision is to only evaluate air breaks in the exercise PB protocol. So there is no restriction to recruiting women as test subjects.

Conkin, Johnny↗

Gender Consideration in Experiment Design for Air Break in Prebreathe

If gender is a confounder of the decompression sickness (DCS) or venous gas emboli (VGE) outcomes of a proposed air break in oxygen prebreathe (PB) project, then decisions about the final experiment design must be made. We evaluated if the incidence of DCS and VGE from tests in altitude chambers over 20 years were different between men and women after resting and exercise PB protocols. Nitrogen washout during PB is our primary risk mitigation strategy to prevent subsequent DCS and VGE in subjects. Bubbles in the pulmonary artery (venous blood) were detected from the precordial position using Doppler ultrasound bubble detectors. The subjects were monitored for VGE for four min at about 15 min intervals for the duration of the altitude exposure, with maximum bubble grade assigned a Spencer Grade of IV.

Conkin, Johnny↗

A Start Toward Micronucleus-Based Decompression Models; Altitude Decompression

Do gaseous micronuclei trigger the formation of bubbles in decompression sickness (DCS)? Most previous instructions for DCS prevention have been oriented toward supersaturated gas in tissue. We are developing a mathematical model that is oriented toward the expected behavior of micronuclei. The issue is simplified in altitude decompressions because the aviator or astronaut is exposed only to decompression, whereas in diving there is a compression before the decompression. The model deals with four variables: duration of breathing of 100% oxygen before going to altitude (O2 prebreathing), altitude of the exposure, exposure duration, and rate of ascent. Assumptions: a) there is a population of micronuclei of various sizes having a range of characteristics, b) micronuclei are stable until they grow to a certain critical nucleation radius, c) it takes time for gas to diffuse in or out of micronuclei, and d) all other variables being equal, growth of micronuclei upon decompression is more rapid at high altitude because of the rarified gas in the micronuclei. To estimate parameters, we use a dataset of 4,756 men in altitude chambers exposed to various combinations of the model s variables. The model predicts occurrence of DCS symptoms quite well. It is notable that both the altitude chamber data and the model show little effect of O2 prebreathing until it lasts more than 60 minutes; this is in contrast to a conventional idea that the benefit of prebreathing is directly due to exponential washout of tissue nitrogen. The delay in response to O2 prebreathing can be interpreted as time required for outward diffusion of nitrogen; when the micronuclei become small enough, they are disabled, either by crushing or because they cannot expand to a critical nucleation size when the subject ascends to altitude.

Van Liew, H. D.↗

Prebreathe Protocol for Extravehicular Activity Technical Consultation Report

In the performance of EVA by that National Aeronautics and Space Administration (NASA) astronauts, there exists a risk of DCS as the suit pressure is reduced to 4.3 pounds per square inch, absolute (psia) from the International Space Station (ISS) pressure of 14.7 psia. Several DCS-preventive procedures have been developed and implemented. Each of these procedures involve the use of oxygen (O2) prebreathe to effectively washout tissue nitrogen (N2).The management of the ISS Programs convened an expert independent peer review Team to conduct a review of the Decompression Sickness (DCS) risks associated with the Extra Vehicular Activity (EVA) Campout Prebreathe (PB) protocol for its consideration for use on future missions. The major findings and recommendations of the expert panel are: There is no direct experimental data to confirm the potential DCS risks of the Campout PB protocol. However, based on model data, statistical probability, physiology, and information derived from similar PB protocols, there is no compelling evidence to suggest that the Campout PB protocol is less safe than the other NASA approved PB protocols.

Ross, Jerry↗

Exploration EVA Purge Flow Assessment

An advanced future spacesuit will require properly sized suit and helmet purge flow rates in order to sustain a crew member with a failed Portable Life Support System (PLSS) during an Extravehicular Activity (EVA). A computational fluid dynamics evaluation was performed to estimate the helmet purge flow rate required to washout carbon dioxide and to prevent the condensing ("fogging") of water vapor on the helmet visor. An additional investigation predicted the suit purge flow rate required to provide sufficient convective cooling to keep the crew member comfortable. This paper summarizes the results of these evaluations.

Navarro, Moses↗

Exploration EVA Purge Flow Assessment

An advanced future spacesuit will require properly sized suit and helmet purge flow rates in order to sustain a crew member with a failed Portable Life Support System (PLSS) during an Extravehicular Activity (EVA). A computational fluid dynamics evaluation was performed to estimate the helmet purge flow rate required to washout carbon dioxide and to prevent the condensing ("fogging") of water vapor on the helmet visor. An additional investigation predicted the suit purge flow rate required to provide sufficient convective cooling to keep the crew member comfortable. This paper summarizes the results of these evaluations.

Navarro, Moses↗

Highly Loaded Composite Strut Test Results

Highly loaded composite struts from a proposed truss-based Altair lunar lander descent stage concept were selected for development under NASA's Advanced Composites Technology program. Predicted compressive member forces during launch and ascent of over -100,000 lbs were much greater than the tensile loads. Therefore, compressive failure modes, including structural stability, were primary design considerations. NASA's industry partner designed and built highly loaded struts that were delivered to NASA for testing. Their design, fabricated on a washout mandrel, had a uniform-diameter composite tube with composite tapered ends. Each tapered end contained a titanium end fitting with facing conical ramps that are overlaid and overwrapped with composite materials. The highly loaded struts were loaded in both tension and compression, with ultimate failure produced in compression. Results for the two struts tested are presented and discussed, along with measured deflections, strains and observed failure mechanisms.

Wu, K. C.↗

Hydrostatic Hyperbaric Chamber Ventilation System

The hydrostatic hyperbaric chamber (HHC) represents the merger of several technologies in development for NASA aerospace applications, harnessed to directly benefit global health. NASA has significant experience developing composite hyperbaric chambers for a variety of applications, including the treatment of medical conditions. NASA also has researched the application of water-filled vessels to increase tolerance of acceleration forces. The combination of these two applications has resulted in the hydrostatic chamber, which has been conceived as a safe, affordable means of making hyperbaric oxygen therapy available in the developing world for the treatment of a variety of medical conditions. Specifically, hyperbaric oxygen therapy is highly-desired as a possibly curative treatment for Buruli Ulcer, an infectious condition that afflicts children in sub-Saharan Africa. Hyperbaric oxygen therapy is simply too expensive and too dangerous to implement in the developing world using standard equipment. The hydrostatic hyperbaric chamber technology changes the paradigm. The HHC differs from standard hyperbaric chambers in that the majority of its volume is filled with water which is pressurized by oxygen being supplied in the portion of the chamber containing the patient s head. This greatly reduces the amount of oxygen required to sustain a hyperbaric atmosphere, thereby making the system more safe and economical to operate. An effort was taken to develop an HHC system to apply HBOT to children that is simple and robust enough to support transport, assembly, maintenance and operation in developing countries. This paper details the concept for an HHC ventilation and pressurization system that will provide controlled pressurization of the system, and provide adequate washout of carbon dioxide while the subject is enclosed in the confined space during the administration of the medical treatment. The concept took into consideration operational complexity, safety to the patient and operating personnel, and physiological considerations. The simple schematic, comprised of easily acquired commercial hardware, supports sustainability.

Sargusingh, Miriam M.↗

Hydrostatic Hyperbaric Chamber Ventilation System

The hydrostatic hyperbaric chamber (HHC) represents the merger of several technologies in development for NASA aerospace applications, harnessed to directly benefit global health. NASA has significant experience developing composite hyperbaric chambers for a variety of applications. NASA also has researched the application of water-filled vessels to increase tolerance of acceleration forces. The combination of these two applications has resulted in the hydrostatic chamber, which has been conceived as a safe, affordable means of making hyperbaric oxygen therapy (HBOT) available in the developing world for the treatment of a variety of medical conditions. Specifically, HBOT is highly-desired as a possibly curative treatment for Buruli Ulcer, an infectious condition that afflicts children in sub-Saharan Africa. HBOT is simply too expensive and too dangerous to implement in the developing world using standard equipment. The HHC technology changes the paradigm. The HHC differs from standard hyperbaric chambers in that the majority of its volume is filled with water which is pressurized by oxygen being supplied in the portion of the chamber containing the patient s head. This greatly reduces the amount of oxygen required to sustain a hyperbaric atmosphere, thereby making the system more safe and economical to operate. An effort was taken to develop an HHC system to apply HBOT to children that is simple and robust enough to support transport, assembly, maintenance and operation in developing countries. This paper details the concept for an HHC ventilation and pressurization system to provide controlled pressurization and adequate washout of carbon dioxide while the subject is enclosed in the confined space during the administration of the medical treatment. The concept took into consideration operational complexity, safety to the patient and operating personnel, and physiological considerations. The simple schematic, comprised of easily acquired commercial hardware, supports sustainability.

Sarguisingh, Miriam J.↗

Comment on "'Elevated Heat Pump' Hypothesis for the Aerosol-Monsoon Hydroclimate Link: 'Grounded' in Observations?" by S. Nigam and M. Bollasina

In their recent paper, Nigam and Bollasina [2010] (hereinafter NB) claimed to have found observational evidences that are at variance with the elevated heat pump (EHP) hypothesis regarding the possible impacts of absorbing aerosols on the South Asian summer monsoon [Lau et al., 2006; Lau and Kim, 2006]. We found NB's arguments and inferences against the EHP hypothesis flawed, stemming from their own out of context interpretation of the hypothesis. NB argued that the simultaneous negative correlation of aerosol with rainfall, and correlations with other quantities in May, are evidence against the EHP hypothesis. Their argument cannot be justified. First, Lau and Kim [2006] (hereinafter LK06) never stated that the main rainfall response to EHP is in May. Second, the EHP is about responses of the entire Indian monsoon system that are nonlocal in space and time with respect to the aerosol forcing. As shown in Figure 4 of LK06, while the aerosol anomalies are strongest in April-May, the strongest rainfall response is in June-July, with the enhanced rainfall fed by an induced thermally driven circulation which brings additional moisture from the ocean to the Indian subcontinent. Third, the increased rainfall over the Bay of Bengal as shown in Figure 1a of NB and the increased low-level convergence in Figure 1f of NB do not necessarily reflect responses associated with EHP but rather the large ]scale circulation that provides the buildup of the aerosols before the onset of the monsoon rainfall over India. Because aerosol can only accumulate where there is little or no washout by rain, the negative correlation is a necessary condition for increased atmospheric loading of aerosols. For the same reason, the spatial distributions of rainfall and aerosol generally are offset with each other, i.e., high aerosol in regions of low rainfall. This is evident in Figure 1, which shows the climatological mean of the MODIS aerosol optical depth (AOD), and TRMM rainfall over India in May. The maximum AOD is found over the Indo-Gangetic Plain and the desert regions of northwest India and Pakistan

Lau, K. M.↗