Does Mixing Make Residential Ventilation More Effective?

Ventilation dilutes or removes indoor contaminants to reduce occupant exposure. In a multi-zone environment such as a house, there will be different dilution rates and different source strengths in every zone. The total ventilation rate is the most important factor in determining the exposure of occupants to given sources, but the zone- specific distribution of exhaust and supply air, and the mixing of ventilation air can have significant roles. Different types of ventilation systems will provide different amounts of mixing depending on several factors such as air leakage through the building envelope, air distribution systems and the location of sources and occupants. This paper reports recent results of investigations to determine the impact that air mixing has on exposures of residential occupants to prototypical contaminants of concern. Evaluations of existing field measurements and simulations reported in the literature are combined with new analyses to provide an integrated overview of the topic. The results show that for extreme cases additional mixing can be a significant factor but for typical homes looking at average exposures mixing is not helpful and can even make exposures worse.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

HOW THE LEED VENTILATION CREDIT IMPACTS ENERGY CONSUMPTION OF GSHP SYSTEMS A CASE STUDY FOR PRIMARY SCHOOLS

This paper presents a study on the impacts of increased outdoor air (OA) ventilation on the performance of ground-source heat pump (GSHP) systems that heat and cool typical primary schools. Four locations Phoenix, Miami, Seattle, and Chicago are selected in this study to represent different climate zones in the United States. eQUEST, an integrated building and HVAC system energy analysis program, is used to simulate a typical primary school and the GSHP system at the four locations with minimum and 30% more than minimum OA ventilation. The simulation results show that, without an energy recovery ventilator, the 30% more OA ventilation results in an 8.0 13.3% increase in total GSHP system energy consumption at the four locations. The peak heating and cooling loads increase by 20.2 30% and 14.9 18.4%, respectively, at the four locations. The load imbalance of the ground heat exchanger is increased in hot climates but reduced in mild and cold climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A network model for natural ventilation simulation in deep buried underground structures

The study of underground natural ventilation opportunities has become increasingly significant in recent years with its promise of wide application in underground structures such as underground hydro power stations, metro stations, underground parking and laboratories. It is recognized that deployment of natural ventilation constitutes a passive technology that can lead to significant energy conservation if applied judiciously. This paper focuses on underground buildings that are buried deeply and typically consist of an underground complex network of connected structures. The other characteristic is that these structures house machinery and devices that generate heat, leading to elevated internal air temperatures. Combined with the deep location, it implies that buoyancy forces are significant which make natural ventilation through vertical shaft openings a viable option. These characteristics demand a study of the heat transfer processes between ambient conditions, soil and underground buildings. In this paper, we present a dynamic flow network model with loops for multizone airflow and apply it to deep buried underground structures considering the dominant heat transfer characteristics, not only through the elements of the network but also the heat exchange with the envelope and adjacent soil mass. Finally, a small-scale experiment of occurring airflow is conducted and compared with the outcomes of the dynamic simulation of the proposed model. The comparison serves as validation and illustration of the application potential of the network model for natural ventilation investigation and consecutive optimization of its use in underground buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data-driven model for cross ventilation potential in high-density cities based on coupled CFD simulation and machine learning

Effective urban ventilation through decent urban planning and building design can alleviate the deterioration of the urban built environment. Furthermore, natural ventilation requirements and guidelines in current building codes and standards are either qualitative or quantitative but subject to an absolute indoor airspeed threshold without considering the outdoor wind environment. To fill this gap, this paper develops an urban-scale coupled indoor and outdoor computational fluid dynamics (CFD) model and defines a novel ventilation index to assess natural ventilation potential. The index considers wind environments of both indoor and outdoor spaces.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mechanical ventilation and indoor air quality in recently constructed U.S. homes in marine and cold-dry climates

Data were collected to characterize whole-house mechanical ventilation (WHMV) and indoor air quality (IAQ) in 55 homes in the Marine climate of Oregon and the Cold-Dry climate of Colorado in the U.S. Sixteen homes were monitored for two weeks, with and without WHMV operating. Ventilation airflows; airtightness; time-resolved CO 2 , PM2.5 and radon; and time-integrated NO 2 , NO X and formaldehyde were measured. Participants provided information about IAQ-impacting activities, perceptions and ventilation use. All homes had operational cooktop ventilation and bathroom exhaust. Thirty homes had equipment that could meet the ASHRAE 62.2–2010 standard with continuous or controlled runtime and 34 had some WHMV operating as found. Thirty-five of 46 participants with WHMV reported they did not know how to operate it, and only half of the systems were properly labeled. Two-week homes had lower formaldehyde, radon, CO 2 and NO (NO X -NO 2 ) when operated with WHMV, and had faster PM 2.5 decays following indoor emission events. Overall IAQ satisfaction was similar in Oregon and Colorado, but more Colorado participants (19% vs 3%) felt their IAQ could be improved and more reported dryness as a problem (58% vs. 14%). The collected data indicate that there are benefits of operating WHMV, even when continuous use may not be needed because outdoor pollutant concentrations are low and indoor sources do not present substantial challenges.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Creation of a Robust and Generalizable Machine Learning Classifier for Patient Ventilator Asynchrony

Background: As healthcare increasingly digitizes, streaming waveform data is being made available from an variety of sources, but there still remains a paucity of performant clinical decision support systems. For example, in the intensive care unit (ICU) existing automated alarm systems typically rely on simple thresholding that result in frequent false positives. Recurrent false positive alerts create distrust of alarm mechanisms that can be directly detrimental to patient health. To improve patient care in the ICU, we need alert systems that are both pervasive, and accurate so as to be informative and trusted by providers. Objective: We aimed to develop a machine learning-based classifier to detect abnormal waveform events using the use case of mechanical ventilation waveform analysis, and the detection of harmful forms of ventilation delivery to patients. We specifically focused on detecting injurious subtypes of patient-ventilator asynchrony (PVA).Methods: Using a dataset of breaths recorded from 35 different patients, we used machine learning to create computational models to automatically detect, and classify two types of injurious PVA, double trigger asynchrony (DTA), breath stacking asynchrony (BSA). We examined the use of synthetic minority over-sampling technique (SMOTE) to overcome class imbalance problems, varied methods for feature selection, and use of ensemble methods to optimize the performance of our model. Results: We created an ensemble classifier that is able to accurately detect DTA at a sensitivity/specificity of 0.960/0.975, BSA at sensitivity/specificity of 0.944/0.987, and non-PVA events at sensitivity/specificity of .967/.980. Conclusions: Our results suggest that it is possible to create a high-performing machine learning-based model for detecting PVA in mechanical ventilator waveform data in spite of both intra-patient, and inter-patient variability in waveform patterns, and the presence of clinical artifacts like cough and suction procedures. Our work highlights the importance of addressing class imbalance in clinical data sets, and the combined use of statistical methods and expert knowledge in feature selection.

97 MATHEMATICS AND COMPUTING↗

Why We Ventilate

It is widely accepted that ventilation is critical for providing good indoor air quality (IAQ) in homes. However, the definition of"good" IAQ, and the most effective, energy efficient methods for delivering it are still matters of research and debate. This paper presents the results of work done at the Lawrence Berkeley National Lab to identify the air pollutants that drive the need for ventilation as part of a larger effort to develop a health-based ventilation standard. First, we present results of a hazard analysis that identified the pollutants that most commonly reach concentrations in homes that exceed health-based standards or guidelines for chronic or acute exposures. Second, we present results of an impact assessment that identified the air pollutants that cause the most harm to the U.S. population from chronic inhalation in residences. Lastly, we describe the implications of our findings for developing effective ventilation standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Consumer Guide to Home Ventilation

Learn about the types of home ventilation and how ventilation can help you avoid moisture problems. This fact sheet from Energy Saver includes information why it's important to ventilate and how you can use ventilation strategies to control moisture in your home for comfort and energy savings.

ventilation, carbon monoxide, moisture, fans, duct↗

Evaluation of Ventilation Strategies in New Construction Multifamily Buildings

In multifamily buildings, particularly in the Northeast, exhaust ventilation strategies are the norm as a means of meeting both local exhaust and whole-unit mechanical ventilation rates. The issue of where the 'fresh' air is coming from is gaining significance as air-tightness standards for enclosures become more stringent, and the 'normal leakage paths through the building envelope' disappear. CARB researchers have found that the majority of high performance, new construction, multifamily housing in the Northeast use one of four general strategies for ventilation: continuous exhaust only with no designated supply or make-up air source, continuous exhaust with ducted make-up air to apartments, continuous exhaust with supply through a make-up air device integral to the unit HVAC, and continuous exhaust with supply through a passive inlet device, such as a trickle vent. Insufficient information is available to designers on how these various systems are best applied. Product performance data are based on laboratory tests, and the assumption is that products will perform similarly in the field. Proper application involves matching expected performance at expected building pressures, but there is no guarantee that those conditions will exist consistently in the finished building. This research effort, which included several weeks of building pressure monitoring, sought to provide field validation of system performance. The performance of four substantially different strategies for providing make-up air to apartments was evaluated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Evaluation of Ventilation Strategies in New Construction Multifamily Buildings, New York, New York (Fact Sheet)

In multifamily buildings, particularly in the Northeast, exhaust ventilation strategies are the norm as a means of meeting both local exhaust and whole-unit mechanical ventilation rates. The issue of where the 'fresh' air is coming from is gaining significance as air-tightness standards for enclosures become more stringent, and the 'normal leakage paths through the building envelope' disappear. CARB researchers have found that the majority of high performance, new construction, multifamily housing in the Northeast use one of four general strategies for ventilation: continuous exhaust only with no designated supply or make-up air source, continuous exhaust with ducted make-up air to apartments, continuous exhaust with supply through a make-up air device integral to the unit HVAC, and continuous exhaust with supply through a passive inlet device, such as a trickle vent. Insufficient information is available to designers on how these various systems are best applied. Product performance data are based on laboratory tests, and the assumption is that products will perform similarly in the field. Proper application involves matching expected performance at expected building pressures, but there is no guarantee that those conditions will exist consistently in the finished building. This research effort, which included several weeks of building pressure monitoring, sought to provide field validation of system performance. The performance of four substantially different strategies for providing make-up air to apartments was evaluated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Solutions Case Study: Evaluation of Ventilation Strategies in New Construction Multifamily Buildings, New York, New York

In multifamily buildings, particularly in the Northeast, exhaust ventilation strategies are the norm as a means of meeting both local exhaust and whole-unit mechanical ventilation rates. The issue of where the "fresh" air is coming from is gaining significance as air-tightness standards for enclosures become more stringent, and the "normal leakage paths through the building envelope" disappear. Consortium for Advanced Residential Buildings researchers have found that the majority of high performance, new construction, multifamily housing in the Northeast use one of four general strategies for ventilation: continuous exhaust only with no designated supply or make-up air source, continuous exhaust with ducted make-up air to apartments, continuous exhaust with supply through a make-up air device integral to the unit HVAC, and continuous exhaust with supply through a passive inlet device, such as a trickle vent. This research effort included several weeks of building pressure monitoring to validate system performance of the different strategies for providing make-up air to apartments.

apartments↗

Technology Solutions Case Study: Sealed Crawl Space with Integrated Whole-House Ventilation in a Cold Climate

The Building America team Consortium for Advanced Residential Buildings (CARB) investigated a hybrid ventilation method that included the exhaust air from the crawl space as part of an ASHRAE 62.2-compliant whole-house ventilation strategy. The CARB team evaluated this hybrid ventilation method through long-term field monitoring of temperature, humidity, and pressure conditions within the crawl spaces of two homes (one occupied and one unoccupied) in New York state.

ASHRAE 62.2-2010↗

12th US/North American mine ventilation symposium

Topics covered include: ventilation planning for metal/non-metal and coal mines, spontaneous combustion, heat and humidity, miner's act and mine seals, numerical modeling, coal mine methane, mine dust, tunnel ventilation, mine fans, diesel emissions control, mine fires, and general ventilation design and monitoring. The papers, talks and presentations are available for free download from the www.smenet.org site; printed copies of the proceedings are no longer available.

01 COAL, LIGNITE, AND PEAT↗

A new look at ocean ventilation time scales and their uncertainties

Abstract A suite of eddy‐resolving ocean transient tracer model simulations are first compared to observations. Observational and model pCFC‐11 ages agree quite well, with the eddy‐resolving model adding detail. The CFC ages show that the thermocline is a barrier to interior ocean exchange with the atmosphere on time scales of 45 years, the measureable CFC transient, although there are exceptions. Next, model simulations are used to quantify effects on tracer ages of the spatial dependence of internal ocean tracer variability due to stirring from eddies and biases from nonstationarity of the atmospheric transient when there is mixing. These add to tracer age uncertainties and biases, which are large in frontal boundary regions, and small in subtropical gyre interiors. These uncertainties and biases are used to reinterpret observed temporal trends in tracer‐derived ventilation time scales taken from observations more than a decade apart, and to assess whether interpretations of changes in tracer ages being due to changes in ocean ventilation hold water. For the southern hemisphere subtropical gyres, we infer that the rate of ocean ventilation 26–27.2 σ θ increased between the mid‐1990s and the decade of the 2000s. However, between the mid‐1990s and the decade of the 2010s, there is no significant trend—perhaps except for South Atlantic. Observed age/AOU/ventilation changes are linked to a combination of natural cycles and climate change, and there is regional variability. Thus, for the future it is not clear how strong or steady in space and time ocean ventilation changes will be.

58 GEOSCIENCES↗

Learning-based CO 2 concentration prediction: Application to indoor air quality control using demand-controlled ventilation

There have been increasing concerns over the air quality inside buildings as high levels of bio-effluents can cause nausea, dizziness, headaches, and fatigue to the people working in those spaces. First published in 2004 as Standard 62.1, ASHRAE Standard 62.2-2019 requires highly occupied spaces to implement heating, ventilation, and air conditioning (HVAC) that can dilute contaminants produced by occupants. In this regard, occupant-centric ventilation control has been regarded as an effective practice to maintain a satisfactory indoor air quality (IAQ) when dealing with highly variable occupancy environments. However, few established models in current literature and practice consider dynamic occupancy behavior and adaptive IAQ control. To address this gap, a dynamic indoor CO2 model is constructed using machine learning algorithms to forecast CO2concentrations across a range of forecasting horizons. Herein, we tuned and compared six state-of-the-algorithms—including Support Vector Machine, Ada Boost, Random Forest, Gradient Boosting, Logistic Regression, and Multilayer Perceptron. The algorithms’ performances are validated using CO 2 and historical meteorological data collected from a campus classroom with a variable occupancy rate. Simulation results showed that Multilayer Perceptron can strongly predict the volatile CO 2 behavior and also outperforms other algorithms in terms of accuracy. Furthermore, a control strategy capable of modeling and detecting dynamic patterns of CO 2 level is utilized to modulate the ventilation rate in real-time and also reduce the energy consumption. The proposed controller reduced the HVAC fan’s energy consumption by 51.4% and provide ventilation as needed per the ASHRAE standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Should regional ventilation function be considered during radiation treatment planning to prevent radiation-induced complications?

Purpose: To investigate the incorporation of pretherapy regional ventilation function in predicting radiation fibrosis (RF) in stage III nonsmall cell lung cancer (NSCLC) patients treated with concurrent thoracic chemoradiotherapy. Methods: Thirty-seven patients with stage III NSCLC were retrospectively studied. Patients received one cycle of cisplatin–gemcitabine, followed by two to three cycles of cisplatin–etoposide concurrently with involved-field thoracic radiotherapy (46–66 Gy; 2 Gy/fraction). Pretherapy regional ventilation images of the lung were derived from 4D computed tomography via a density change–based algorithm with mass correction. In addition to the conventional dose–volume metrics (V{sub 20}, V{sub 30}, V{sub 40}, and mean lung dose), dose–function metrics (fV{sub 20}, fV{sub 30}, fV{sub 40}, and functional mean lung dose) were generated by combining regional ventilation and radiation dose. A new class of metrics was derived and referred to as dose–subvolume metrics (sV{sub 20}, sV{sub 30}, sV{sub 40}, and subvolume mean lung dose); these were defined as the conventional dose–volume metrics computed on the functional lung. Area under the receiver operating characteristic curve (AUC) values and logistic regression analyses were used to evaluate these metrics in predicting hallmark characteristics of RF (lung consolidation, volume loss, and airway dilation). Results: AUC values for the dose–volume metrics in predicting lung consolidation, volume loss, and airway dilation were 0.65–0.69, 0.57–0.70, and 0.69–0.76, respectively. The respective ranges for dose–function metrics were 0.63–0.66, 0.61–0.71, and 0.72–0.80 and for dose–subvolume metrics were 0.50–0.65, 0.65–0.75, and 0.73–0.85. Using an AUC value = 0.70 as cutoff value suggested that at least one of each type of metrics (dose–volume, dose–function, dose–subvolume) was predictive for volume loss and airway dilation, whereas lung consolidation cannot be accurately predicted by any of the metrics. Logistic regression analyses showed that dose–function and dose–subvolume metrics were significant (P values ≤ 0.02) in predicting volume airway dilation. Likelihood ratio test showed that when combining dose–function and/or dose–subvolume metrics with dose–volume metrics, the achieved improvements of prediction accuracy on volume loss and airway dilation were significant (P values ≤ 0.04). Conclusions: The authors’ results demonstrated that the inclusion of regional ventilation function improved accuracy in predicting RF. In particular, dose–subvolume metrics provided a promising method for preventing radiation-induced pulmonary complications.

60 APPLIED LIFE SCIENCES↗

Multifamily Individual Heating and Ventilation Systems, Lawrence, Massachusetts (Fact Sheet)

The conversion of an older Massachusetts building into condominiums illustrates a safe, durable, and cost-effective solution for heating and ventilation systems that can potentially benefit millions of multifamily buildings. Merrimack Valley Habitat for Humanity (MVHfH) partnered with U.S. Department of Energy Building America team Building Science Corporation (BSC) to provide high performance affordable housing for 10 families in the retrofit of an existing mass masonry building (a former convent). The original ventilation design for the project was provided by a local engineer and consisted of a single large heat recovery ventilator (HRV) located in a mechanical room in the basement with a centralized duct system providing supply air to the main living space and exhausting stale air from the single bathroom in each apartment. This design was deemed to be far too costly to install and operate for several reasons: the large central HRV was oversized and the specified flows to each apartment were much higher than the ASHRAE 62.2 rate; an extensive system of ductwork, smoke and fire dampers, and duct chases were specified; ductwork required a significant area of dropped ceilings; and the system lacked individual ventilation control in the apartments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Formaldehyde and acetaldehyde exposure mitigation in US residences: In-home measurements of ventilation control and source control

Measurements were taken in new US residences to assess the extent to which ventilation and source control can mitigate formaldehyde exposure. Increasing ventilation consistently lowered indoor formaldehyde concentrations. However, at a reference air exchange rate of 0.35 h -1 , increasing ventilation was up to 60% less effective than would be predicted if the emission rate were constant. This is consistent with formaldehyde emission rates decreasing as air concentrations increase, as observed in chamber studies. In contrast, measurements suggest acetaldehyde emission was independent of ventilation rate. To evaluate the effectiveness of source control, formaldehyde concentrations were measured in Leadership in Energy and Environmental Design (LEED) certified/Indoor airPLUS homes constructed with materials certified to have low emission rates of volatile organic compounds (VOC). At a reference air exchange rate of 0.35 h -1 , and adjusting for home age, temperature and relative humidity, formaldehyde concentrations in homes built with low-VOC materials were 42% lower on average than in reference new homes with conventional building materials. Without adjustment, concentrations were 27% lower in the low-VOC homes. The mean and standard deviation of formaldehyde concentration were 33 μg m-3 and 22 μg m -3 for low-VOC homes and 45 μg m -3 and 30 μg m -3 for conventional.

99 GENERAL AND MISCELLANEOUS↗