Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ultrasound techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Thermomechanical Properties of Hafnium Hydride for Radiation Shielding in Tokamak Devices

The development of effective neutron shielding materials is of paramount importance for the progression of fusion technologies with the aim of producing clean and sustainable energy for future generations. This study demonstrates the successful fabrication of a promising candidate material for shielding applications, hafnium hydride, through the powder metallurgy process. Powder metallurgy fabrication resulted in the production of 91% dense, crack-free, ε-phase HfH 2 pellets with a hydrogen-to-metal ratio of 1.89 to 2.00. Resonant ultrasound spectroscopy (RUS) was used to measure a Young’s modulus of 34.52 ± 2.70 GPa and a shear modulus of 12.25 ± 0.18 GPa. Nanoindentation techniques have been used to establish a hardness value of 4.45 ± 1.63 GPa, and a Young’s modulus of 47.8 ± 6.4 GPa was determined using Poison’s ratio from RUS. Hydrogen release was measured using thermogravimetric analysis and appeared to occur in three different regimes as the sample transitioned through the ε- and δ-phases. Heat capacity matched literature data up to 600 K, after which a rapid increase was observed due to phase transformations occurring with hydrogen loss.

Hafnium hydride↗

Thermoelastic properties of zircon: Implications for geothermobarometry

Abstract A thermal-pressure equation of state has been determined for zircon (ZrSiO4) that characterizes its thermoelastic behavior at metamorphic conditions. New pressure-volume (P-V) data from a “Mud Tank” zircon have been collected from 1 bar to 8.47(1) GPa using X-ray diffraction, and elastic moduli were measured from room temperature up to 1172 K by resonance ultrasound spectroscopy. These data were fitted simultaneously with temperature-volume (T-V) data from the literature in EosFit7c using a new scaling technique. The parameters of a third-order Birch-Murnaghan EoS with a Mie-Grüneisen-Debye model for thermal pressure have compressional EoS parameters K0T = 224.5(1.2) GPa, K0T' = 4.90(31) with a fixed initial molar volume V0 = 39.26 cm3/mol and thermal parameters γ0 = 0.868(15), q = 2.37(80), and ΘD = 848(38) K. EoS parameters that describe the variation of unit-cell parameters with pressure and temperature were determined using an isothermal-type EoS. This new EoS confirms that zircons are stiffer than garnets and exhibit a much lower thermal expansion. This results in steep isomekes between zircon and garnets, which makes zircon trapped as inclusions in garnets at metamorphic conditions a good piezothermometer.

Geochemistry & Geophysics↗

Plantar soft tissue thickness during ground contact in walking

A technique is introduced for the measurement of plantar soft tissue thickness during barefoot walking. Subjects stepped into an adjustable Plexiglas frame which ensured that the required bony landmarks were appropriately positioned relative to a linear ultrasound probe connected to a conventional 7.5 MHz ultrasound scanner. Clear images of the metatarsal condyles or other foot bones were obtained throughout ground contact. Subsequent analysis of the video taped images using a motion analysis system allowed the tissue displacement to be calculated as a function of time. The tissue underneath the second metatarsal head was shown to undergo an average maximum compression of 45.7% during the late stages of ground contact during first step gait in a group of five normal subjects with a mean unloaded tissue thickness of 15.2 mm. The technique has a number of applications, including use in the validation of deformation predicted by finite element models of the soft tissue of the foot, and the study of alterations in the cushioning properties of the heel by devices which constrain the displacement of the heel pad.

Non-NASA Center↗

Non-Invasive Measurement of Pulsatile Intracranial Pressures Using Ultrasound

Early detection of elevated intracranial pressure (ICP) will aid clinical decision-making for head trauma, brain tumor and other cerebrovascular diseases. Conventional methods, however, require surgical procedures which take time and are accompanied by increased risk of infection. Accordingly we have developed and refined a new ultrasound device to measure skull movements which are known to occur in conjunction with altered ICP. The principle of this device is based upon pulse phase locked loop (PPLL), which enables us to detect changes in distance on the order of microns between an ultrasound transducer on one side of the skull and the opposite inner surface of the cranium. The present study was designed to verify this measurement technique in cadavera. Transcranial distance was increased in steps of 10 mmHg from zero to 50 mmHg by saline infusion into the lateral ventricle of two cadavera. In separate experiments, pulsations of ICP with the amplitudes of zero to 2 mmHg were generated by rhythmic injections of saline using a syringe. When the ICP was stepwise increased from zero to 50 mmHg, transcranial distance increased in proportion with the ICP increase (y=12 x - 76, r=0.938), where y is changes in transcranial distance in microns and x is ICP in mmHg. In the data recorded while ICP pulsations were generated, fast Fourier transform analysis demonstrated that cranial pulsations were clearly associated with ICP pulsations. The results indicate that changes in transcranial distance is linearly correlated with those in ICP, and also that the PPLL device has sufficient sensitivity to detect transcranial pulsations which occur in association with the cardiac cycle. By analyzing the magnitude of cranial pulsations, we may be able to estimate the pressure-volume index in the cranium. As a result, estimates of intracranial compliance may be possible by using the PPLL device. Further studies are necessary in normal subjects and patients.

Ueno, Toshiaki↗

High temperature mechanical properties of fluorite crystal structured materials (CeO 2 , ThO 2 , and UO 2 ) and advanced accident tolerant fuels (U 3 Si 2 , UN, and UB 2 )

The mechanical interaction between the fuel and cladding that occurs during operation of a nuclear reactor is important to understand as it can lead to cladding failures and release of radioactive material into the coolant. Additionally, in order to develop better models of the pellet-clad mechanical interactions, the mechanical properties of the fuel at relevant operating temperatures, like the elastic moduli, are needed for current and advanced accident tolerant fuels (ATFs). In this work, elevated temperature nanoindentation and resonant ultrasound spectroscopy were used to measure the moduli and hardness of several fluorite materials (CeO 2 , ThO 2 , UO 2 ) and several ATF candidates (ATF) (U 3 Si 2 , UN, UB 2 ). In addition, a comparison of the two techniques was performed in this study to independently validate the mechanical properties.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Physical interpretation and development of ultrasonic nondestructive evaluation techniques applied to the quantitative characterization of textile composite materials

The development and implementation of advanced ultrasonic nondestructive evaluation methods applied to the characterization of composite materials requires a better understanding of the physics underlying the interaction of ultrasound with the material. The purpose of this investigation is to identify and characterize the features of complex, three dimensional materials that limit the ability of ultrasound to detect flaws in this broad class of emerging materials. In order to explore the interaction of ultrasound with such complex media, we investigate the characteristics of ultrasonic fields which have propagated through samples with complex geometries and/or internal architecture. We focus on the physics that underlies the detection of flaws in such materials.

Miller, James G.↗

Nondestructive evaluation by acousto-ultrasonics

Acousto-ultrasonics is an ultrasonic technique that was originally devised to cope with the particular problems associated with nondestructive evaluation (NDE) of fiber/polymer composite structures. The fiber/polymer composites are more attenuating to ultrasound than any other material presently of interest. This limits the applicability of high-frequency ultrasonics. A common use of ultrasound is the imaging of flaws internal to a structure by scattering from the interface with the flaw. However, structural features of composites can scatter ultrasound internally, thus obscuring the flaws. A need relative to composites is to be able to nondestructively measure the strength of laminar boundaries in order to assess the integrity of a structure. Acousto-ultrasonics has exhibited the ability to use the internal scattering to provide information for determining the strength of laminar boundaries. Analysis of acousto-ultrasonic signals by the wave ray paths that compose it leads to waveform partitioning that enhances the sensitivity to mechanical strength parameters.

Kautz, Harold E.↗

Nanoengineering of 2D MBenes for energy storage applications: A review

2D transition metal borides (MBenes), a flourishing member of the 2D nanomaterial family, show great potential in a number of study areas. MBenes have received increasing attention thanks to their excellent electrical conductivity, structural and mechanical properties, and chemical stability, which have captivated researchers and sparked further exploration. Extensive theoretical and experimental investigations have unveiled its remarkable potential as electrode materials for electrochemical storage applications, making MBenes a subject of great interest. Despite the growing interest and numerous studies conducted, there is a lack of a comprehensive and systematic appraisal of MBenes' applications in electrochemical energy storage systems. Here, in light of this, firstly, we provide an overview of the current progress in the fabrication and characterization of MAB phases and MBenes. For the synthesis of MBenes, the following fabrication techniques were discussed; liquid-phase exfoliation, solid-state mechanical exfoliation, chemical vapor deposition, high-pressure chemical vapor deposition, microwave-assisted chemical etching, and ultrasound-assisted chemical etching methods. Then, we delve into the captivating potential of MBenes, specifically in the realm of energy storage applications and their role in enhancing electrochemical storage capabilities. The discussion encompasses their application in lithium-ion, lithium-sulfur, and lithium-selenide batteries, supercapacitors and other energy storage systems, providing a comprehensive perspective on their contributions to the energy landscape. Finally, a brief but significant summary of the challenges and opportunities of MBenes in practical applications was summarized. The present review provides a guide and scientific motivation for creating and developing advanced MBene-based nanomaterials, addressing the growing demand for cutting-edge energy storage systems.

25 ENERGY STORAGE↗

Optic Nerve Sheath Diameter: Translating a Terrestrial Focused Technique into a Clinical Monitoring Tool for Spaceflight

Ultrasonography is increasingly used to quickly measure optic nerve sheath diameter (ONSD) when increased intracranial pressure (ICP) is suspected. NASA Space and Clinical Operations Division has been using ground and on‐orbit ultrasound since 2009 as a proxy for ICP in non‐acute monitoring for space medicine purposes. In the terrestrial emergency room population, an ONSD greater than 0.59 cm is considered highly predictive of elevated intracranial pressure. However, this cut‐off limit is not applicable to the spaceflight setting since over 50% of US Operating Segment (USOS) astronauts have an ONSD greater than 0.60 cm even before launch. Crew Surgeon clinical decision‐making is complicated by the fact that many astronauts have history of previous spaceflights. Our data characterize the distribution of baseline ONSD in the astronaut corps, its longitudinal trends in long‐duration spaceflight, and the predictive power of this measure related to increased ICP outcomes.

Mason, Sara↗

Advanced Ultrasonic Diagnosis of Extremity Trauma: The Faster Exam

Ultrasound is of prO)len accuracy in abdominal and thoracic trauma and may be useful to diagnose extremity injury in situations where radiography is not available such as military and space applications. We prospectively evaluated the utility of extremity , ultrasound performed by trained, non-physician personnel in patients with extremity trauma, to simulate remote aerospace or military applications . Methods: Patients with extremity trauma were identified by history, physical examination, and radiographic studies. Ultrasound examination was performed bilaterally by nonphysician personnel with a portable ultrasound device using a 10-5 MHz linear probe, Images were video-recorded for later analysis against radiography by Fisher's exact test. The average time of examination was 4 minutes. Ultrasound accurately diagnosed extremity, injury in 94% of patients with no false positive exams; accuracy was greater in mid-shaft locations and least in the metacarpa/metatarsals. Soft tissue/tendon injury was readily visualized . Extremity ultrasound can be performed quickly and accurately by nonphysician personnel with excellent accuracy. Blinded verification of the utility of ultrasound in patients with extremity injury should be done to determine if Extremity and Respiratory evaluation should be added to the FAST examination (the FASTER exam) and verify the technique in remote locations such as military and aerospace applications.

Dulchavsky, S. A.↗

Microcracking in Composite Laminates: Simulation of Crack-Induced Ultrasound Attenuation

Microcracking in composite laminates is a known precursor to the growth of inter-ply delaminations and larger scale damage. Microcracking can lead to the attenuation of ultrasonic waves due to the crack-induced scattering. 3D elastodynamic finite integration technique (EFIT) has been implemented to explore the scattering of ultrasonic waves due to microcracks in anisotropic composite laminates. X-ray microfocus computed tomography data was directly input into the EFIT simulation for these purposes. The validated anisotropic 3D EFIT code is shown to be a useful tool for exploring the complex multiple-scattering which arises from extensive microcracking.

Leckey, C. A. C.↗

Automated Pneumothorax Diagnosis using Deep Neural Networks

Thoracic ultrasound can provide information leading to rapid diagnosis of pneumothorax with improved accuracy over the standard physical examination and with higher sensitivity than anteroposterior chest radiography. However, the clinical We have Furthermore, remote environments, such as the battlefield or deep-space exploration, may lack expertise for diagnosing developed an automated image interpretation pipeline for the analysis of thoracic ultrasound data and the classification of pneumothorax events to provide decision support in such situations. Our pipeline consists of image preprocessing, data augmentation, and deep learning architectures for medical diagnosis. In this work, we demonstrate that robust, accurate interpretation of chest images and video can be achieved using deep neural networks. A number of novel image processing techniques were employed to achieve this result. Affine transformations were applied for data augmentation. Hyperparameters were optimized for learning rate, dropout regularization, batch size, and epoch iteration by a sequential model-based Bayesian approach. In addition, we utilized pretrained architecturesinterpretation of a patient medical image is highly operator dependent. certain pathologies., applying transfer learning and fine-tuning techniques to fully connected layers. Our pipeline yielded binary classification validation accuracies of 98.3% for M-mode images and 99.8% with B-mode video frames.

US Army collaboration↗

Ultrasound instrumentation for the 7 inch Mach seven tunnel

The use of an Apple II+ microcomputer to collect data during the operation of the 7 inch Mach Seven Tunnel is discussed. A method by which the contamination of liquid oxygen is monitored with sound speed techniques is investigated. The electrical equivalent of a transducer bonded to a high pressure fill plug is studied. The three areas are briefly explained and data gathered for each area are presented.

Mazel, D. S.↗

Damage Detection in Rotorcraft Composite Structures Using Thermography and Laser-Based Ultrasound

New rotorcraft structural composite designs incorporate lower structural weight, reduced manufacturing complexity, and improved threat protection. These new structural concepts require nondestructive evaluation inspection technologies that can potentially be field-portable and able to inspect complex geometries for damage or structural defects. Two candidate technologies were considered: Thermography and Laser-Based Ultrasound (Laser UT). Thermography and Laser UT have the advantage of being non-contact inspection methods, with Thermography being a full-field imaging method and Laser UT a point scanning technique. These techniques were used to inspect composite samples that contained both embedded flaws and impact damage of various size and shape. Results showed that the inspection techniques were able to detect both embedded and impact damage with varying degrees of success.

Anastasi, Robert F.↗

Three-dimensional segmentation of luminal and adventitial borders in serial intravascular ultrasound images

Intravascular ultrasound (IVUS) provides exact anatomy of arteries, allowing accurate quantitative analysis. Automated segmentation of IVUS images is a prerequisite for routine quantitative analyses. We present a new three-dimensional (3D) segmentation technique, called active surface segmentation, which detects luminal and adventitial borders in IVUS pullback examinations of coronary arteries. The technique was validated against expert tracings by computing correlation coefficients (range 0.83-0.97) and William's index values (range 0.37-0.66). The technique was statistically accurate, robust to image artifacts, and capable of segmenting a large number of images rapidly. Active surface segmentation enabled geometrically accurate 3D reconstruction and visualization of coronary arteries and volumetric measurements.

NASA Discipline Cardiopulmonary↗

An Overview of Research in Nondestructive Evaluation at the National Aeronautics and Space Administration’s Langley Research Center

The primary focus of the nondestructive evaluation (NDE) effort at Langley Research Center (LaRC) is to pioneer advances in NDE and structural health monitoring (SHM) through fundamental scientific research, technology development, and transferring these to the scientific and aerospace communities. This research supports a variety of NASA missions in space operations, exploration and aeronautics. The work presented will focus on the development of advanced inspection systems to detect critical flaws in both metallic and non-metallic materials and structures for aerospace applications. The emphasis is on increasing the performance of inspection systems to provide defect detection and quantitative characterization of the material state. LaRC NDE utilizes expertise in computational ultrasonic, thermal and eddy current simulations to reduce measured responses to size and locations of flaws, establish technique limitations and optimize performance. This presentation will highlight research into five strategic areas: (1) The development of novel solutions using state-of-the-art NDE technologies such as eddy current, ultrasound, thermography and x-ray computed tomography; (2) Research in the development of unique NDE technologies such as terahertz, wavefield imaging and nonlinear ultrasound; (3) The application of both computational and analytic models to NDE problems; (4) The development of advanced analytic methods to interpret large complex data sets; and (5) Advanced methods of applying and interrogating sensors for structural health monitoring.

K Elliott Cramer↗

An Overview of Research in Nondestructive Evaluation at the National Aeronautics and Space Administration’s Langley Research Center

The primary focus of the nondestructive evaluation (NDE) effort at Langley Research Center (LaRC) is to pioneer advances in NDE and structural health monitoring (SHM) through fundamental scientific research, technology development, and transferring these to the scientific and aerospace communities. This research supports a variety of NASA missions in space operations, exploration and aeronautics. The work presented will focus on the development of advanced inspection systems to detect critical flaws in both metallic and non-metallic materials and structures for aerospace applications. The emphasis is on increasing the performance of inspection systems to provide defect detection and quantitative characterization of the material state. LaRC NDE utilizes expertise in computational ultrasonic, thermal and eddy current simulations to reduce measured responses to size and locations of flaws, establish technique limitations and optimize performance. This presentation will highlight research into five strategic areas: (1) The development of novel solutions using state-of-the-art NDE technologies such as eddy current, ultrasound, thermography and x-ray computed tomography; (2) Research in the development of unique NDE technologies such as terahertz, wavefield imaging and nonlinear ultrasound; (3) The application of both computational and analytic models to NDE problems; (4) The development of advanced analytic methods to interpret large complex data sets; and (5) Advanced methods of applying and interrogating sensors for structural health monitoring.

NDE↗

Optic Nerve Sheath Diameter: Translating a Terrestrial Focused Technique Into a Clinical Monitoring Tool for Space Flight

Emergency medicine physicians recently adopted the use of ultrasonography to quickly measure optic nerve sheath diameter (ONSD) as concomitant with increased intracranial pressure. NASA Space and Clinical Operations Division has been using ground and on-orbit ultrasound capabilities since 2009 to consider this anatomical measure as a proxy for intracranial pressure in the microgravity environment. In the terrestrial emergency room population, an ONSD greater than 0.59 cm is considered highly predictive of elevated intracranial pressure. However, this cut-off limit is not applicable to the spaceflight setting since over 50% of US Operating Segment (USOS) astronauts have an ONSD greater than 0.60 cm even before missions. Crew Surgeon clinical decision-making is complicated by the fact that many astronauts have history of previous spaceflights. Data will be presented characterizing the distribution of baseline ONSD in the astronaut corps, longitudinal trends in-flight, and the predictive power of this measure related to increased intracranial pressure outcomes.

Mason, Sara S.↗