Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “UNDERGROUND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

FY 2025 End of Year Report: Seismic Monitoring of Underground Vibration Sources using Distributed Acoustic Sensing (DAS) and Seismometers

This end-of-year report summarizes progress on using seismic monitoring to detect, associate, and locate anomalous vibration signals that may indicate potential containment breaches. The work focused on four key tasks: 1. Developing a database of continuous waveforms and ground-truth event data from multiple sensing modalities. 2. Refining and implementing detection and association algorithms to generate a catalog of anomalous underground activities. 3. Testing and improving distributed acoustic sensing amplitude-based geolocation methods to build an event location catalog. 4. Testing and refining seismic array polarization-based geolocation methods to build an event location catalog. This report provides a brief recap of results from the FY25 midyear report (Tasks 1 and 2) and presents new findings from geolocation methods (Tasks 3 and 4).

58 GEOSCIENCES↗

Modeling based assessment of salt cavern performance for underground hydrogen storage

This poster is about the recent progress in my LDRD project of underground hydrogen storage in multiple salt caverns. The main progress of my work is to develop modeling-based workflow to evaluate the salt cavern performance and assess the potential of geomechanical risk for hydrogen storage.

Chang, Kyung Won [Sandia National Laboratories (SN↗

Addressing Critical Challenges of Coal Mines for Underground Pumped Storage Hydropower Using Numerical Calculations

Using existing coal mines to build underground pumped storage hydropower (UPSH) power plants could help reduce the costs associated with starting a new PSH operation. This innovative approach can leverage the existing infrastructure of coal mine facilities available in many regions of the United States. However, technical challenges associated with water quality, mineral chemistry and integrity of subsurface topologies have thus far prevented any of these facilities from going online. Rye Development is investigating the feasibility of UPSH at existing coal mine facilities. In this project, Rye Development received the technical assistance from Oak Ridge National Laboratory to investigate the impacts of minerals, metal particles, and chemical substances in water flow on hydraulic equipment and assess the overall structural integrity of hydraulic equipment in former coal mines.

13 HYDRO ENERGY↗

Cathodic Protection Modeling for Hanford Underground Double-Shell Tank Farms

Hanford stores millions of gallons of radioactive and chemically hazardous waste from the production of weapon materials in tank farms consisting of underground carbon-steel storage tanks surrounded by reinforced concrete. Six of these Hanford tank farms use double-shell storage tanks (DSTs). The DST farms were constructed from 1968 to 1986 with a planned 40–50 year design life, so some are already operating beyond their initial life expectancy. Ultrasonic testing (UT) has indicated significant thinning on the bottom of the secondary (outer) liner of these tanks, believed to arise from groundwater intrusion driving concrete side corrosion. There is no direct access to the steel/concrete interface between the tank and the concrete pad, making it difficult to apply a chemical-based mitigation strategy or to conduct repairs, but cathodic protection (CP) is a possible method to inhibit further concrete-side corrosion. Hanford already uses CP to protect below grade steel piping within the tank farms and connected to the tanks, but this system was not designed to protect the tank bottoms. CP design must account for the structures surrounding the DSTs, including the steel reinforcing bars (rebar) within the concrete pad and vault, various process lines, and the existing CP system. In this study, finite element analysis (FEA) modeling was carried out to simulate CP protection of 1) a single tank and CP anode to develop options for modeling the rebar and to compare to a simpler circuit model and 2) the entire Hanford AN tank farm as a representative example consisting of seven tanks, associated piping, and both existing and new CP anodes. Both circuit and FEA models predict that significant protective current could be delivered to the bottoms of the tanks with the addition of tank-protection anodes below the depth of the tanks. Simulations with only the existing pipe-protection anodes active confirmed that only a very small current to the tank bottoms is predicted under present conditions. Multiple simplified representations of the dome and wall rebar were tested to reduce the computational complexity of the tank-farm simulations, resulting in modeling the rebar as edge elements with a prescribed effective circumference that matches the real rebar surface area. The geometry of the rebar is also simplified into horizontal hoops around the tank walls and radial rebar over the dome with increased effective circumference to retain the target surface area. This simplification was found to greatly reduce the complexity and solution time of the models without large changes in current distributions, especially to the tank bottom. A range of values were tested for model parameters such as soil and concrete resistivities and polarization resistance to investigate their impact on the current and electric potential distributions. Depending on the parameters used, FEA simulations predict some risk of overprotection, particularly on the piping system; since overprotection can also lead to surface damage associated with hydrogen gas generation at the interface (e.g. hydrogen embrittlement or damage to coatings), this needs to be considered when refining the design of the new CP system. Comparison between the FEA models and the circuit model representation demonstrated that the circuit model could not match the predicted FEA current distribution, even when using the exact same surface areas. This discrepancy appeared to be at least partly attributable to the impact of the relative positions of the tank components and anodes to each other and to the ground surface. The FEA model accounts for the relative positions since it solves the governing equations in three dimensions, but the circuit model cannot account for the positioning. In particular, the circuit model underpredicts the current to the tank bottom and overpredicts the current to the dome compared to FEA for the baseline geometry. The FEA models omitted the electrically isolated rebar in the bottom concrete slab. However, a circuit based stray current model estimated that only 2.1% of the total current through the slab would stray into the rebar, corresponding to ~0.21 A for a target current density of 2 mA/ft2 to the tank bottom. The estimated corrosion driven by this amount of stray current is predicted to yield a lifetime of >400 years for the minimum rebar diameter, assuming an acceptable cross-section area loss of 10%.

d'Entremont, Anna [Savannah River National Laborat↗

Relationship between clay minerals and microorganisms in underground hydrogen storage reservoirs: a mini review

Hydrogen (H 2 ) will play a vital role in the global shift towards sustainable energy systems. Due to the high cost and challenges associated with storing hydrogen in large quantities for industrial applications, Underground Hydrogen Storage (UHS) in geological formations has emerged as a promising solution. Clay minerals, abundant in subsurface environments, play a critical role in UHS by providing low permeability, cation exchange capacity, and stability, essential for preventing hydrogen leakage. However, microorganisms in the subsurface, particularly hydrogenotrophic species, interact with clay minerals in ways that can affect the integrity of these storage systems. Microbes form biofilms on clay surfaces, which can cause pore clogging and reduce the permeability of the reservoir, potentially stabilizing H 2 storage and limiting injectivity. Microbial-induced chemical weathering, through the production of organic acids and redox reactions, can degrade clay minerals, releasing metal ions and destabilizing the storage site. These interactions raise concerns about the long-term storage capacity of UHS, as microbial processes could lead to H 2 loss and caprock degradation, compromising the storage system’s effectiveness. This mini review aims to cover the current understanding of the interactions between clay minerals and microorganisms and how these dynamics can affect the safe and sustainable deployment of UHS .

Clark, Allison↗

Underground Imaging by Sub-Terahertz Radiation

Sub-terahertz ground-penetrating radar systems offer an alternative to radio wave-based systems in the airborne imaging of buried objects. Laboratory prototype systems operating in W-band (75–110 GHz) and F-band (90–140 GHz) are presented, detecting the distance between target and source and imaging metal objects buried in mixed soil. The experimental results show that imaging in the 100–150 GHz frequency range is feasible for underground applications but significantly restricted by the attenuation characteristics of the medium covering the targets. A higher power source and more sensitive receiving components are essential to increase the penetration capability and expand the application settings of this approach.

42 ENGINEERING↗

Cyclic loading-unloading impacts on salt cavern stability: Implication for underground hydrogen storage

Underground caverns in salt formations are promising geologic features to store hydrogen (H2) because of salt’s extremely low permeability and self-healing behavior. Successful salt-cavern H2 storage schemes must maximize the efficiency of cyclic injection-production while minimizing H2 loss through adjacent damaged salt. The salt cavern storage community, however, has not fully understood the geomechanical behaviors of salt rocks driven by quick operation cycles of H2 injection-production, whic

Chang, Kyung Won↗

Experimental Study of Underground Heat Storage via Hydraulic Fractures

In this study, we present a laboratory setup to test the energy flow in the form of underground heat storage using hydraulic fractures, a so-called Fracture Thermal Energy Storage (FTES) system. In the experiment, de-ionized water is circulated under high pressure through steel tubing automatically heated to a target temperature. The fluid adjusts to the tubing temperature during its flow before entering a production well drilled into a 250 mm edge length block of Zimbabwe Gabbro. The warm fluid then circulates through a previously created hydraulic fracture at mid-height of the block to a production well drilled at the block periphery. External fracture appearances are sealed using an epoxy resin and the production well by a cork of polydimethylsiloxane. In this cork, tubing to an open outlet is glued. We demonstrated through the results of a preliminary heating experiment that we can transfer nearly all of the heat from the circulating fluid to the block. An efficient charging of the thermal battery is achieved. This first-order demonstration is currently under further improvement and serves as a knowledge basis for the upscaling of mid- to large-scale field implementation of FTES systems.

Möri, Andreas↗

An Assessment of Impacts on Electric End-Use Load Profile of a Typical Residential Building from a Ground Source Heat Pump Systems Integrated with Underground Thermal Energy Storage

Buildings are the primary users of electricity, and a considerable amount of electric energy consumed in residential and commercial buildings is for meeting thermal demands (e.g., space heating/cooling, water heating, etc.). Therefore, integrating thermal energy storage with a building’s energy system has the potential to reshape the electric load profile of the building and mitigate the mismatch between the renewable power supply and the thermal demands of buildings. A novel ground-source heat pump system (GSHP) integrated with underground thermal energy storage (UTES) has been developed to enable flexible electric demand at buildings while meeting their thermal demands with an energy-efficient GSHP system. This paper assessed the potential impacts of the proposed system on the peak electrical demand and annual electricity consumption in a typical residential building at various climate zones in the United States. The results show that by replacing the conventional HVAC system (air conditioner and natural gas furnace) with the UTES integrated GSHP system, summer peak electric demand can be reduced by 27% to 50% depending on the weather. Although the winter peak electrical demand could be increased by up to 70% if the proposed system replaces natural gas furnace, the existing electricity supply system for single-family homes in most regions of the United States have adequate capacity for the replacement. While eliminating the natural gas consumption for space heating, the proposed system consumes more electricity on an annual basis in heating-dominated regions. However, it consumes less electricity in cooling dominated regions. The resulting variance in annual electricity consumption in various climate zones is within 15% compared with the baseline system.

Shi, Liang↗

Analysis of Hydraulic Fracturing on the 4100 Level at the Sanford Underground Research Facility

A series of hydrofractures were performed on the 4100 ft. level of the Sanford Underground Research Facility (SURF) to quantify the minimum principal stress and stress orientation. The motivation for this work was to determine the suitability of the site as a second testbed for the EGS Collab project and to inform the testbed design. EGS Collab is a meso-scale project where experiments are being performed to increase permeability in low-permeability rock and improve our understanding of appropriate techniques and models required for developing enhanced geothermal systems. In order to design the second testbed, a ~50 m vertical HQ (96 mm) pilot borehole was drilled in June, 2019, to perform a series of mini-frac tests to determine rock stress state. Utilizing an elastic model based on the ISIP (Instantaneous Shut In Pressure), testing indicates that the minimum principal stress is 20.4 MPa oriented NNE (24°) and plunges at an angle of approximately 28°.

Ingraham, Mathew↗

Experimental Evaluation of Thermal Storage Performance of a Dual-Purpose Underground Thermal Battery

A geothermal heat pump (GHP) system is an energy-efficient building heating and cooling technology with great potential for reducing energy consumption and decarbonization. However, applications of GHP are still limited due to the high cost, of which 30% is related to the cost of installing the conventional vertical bore ground heat exchangers, which are usually installed in boreholes 60 meters deep. A dual-purpose underground thermal battery (DPUTB) has been developed to offer a low-cost ground heat exchanger with a built-in thermal storage capacity. The DPUTB innovatively integrates a shallow-bore ground heat exchanger (the outer tank), which can be installed in a borehole less than 6 m deep, with thermal energy storage (TES) (the inner tank). DPUTB has the potential to reduce the cost of a ground source heat pump system while allowing shifting the electric demand of the building served by the GHP system from peak to off-peak hours of the electric grid by charging and discharging the thermal storage. A lab-scale (1:125 in volume) DPUTB prototype was built. Phase change material (PCM) was added to increase the thermal storage capacity and maintain the supply water temperature from the TES within the desired range for direct cooling operation during the discharge period. As PCMs are critical to the TES performance of the DPUTB, this study compared the influence of different PCMs (including salt hydrate and organic PCMs) on the discharge performance of the DPUTB. The thermal State of Charge (SoC) of the DPUTB was used to compare the performance resulting from using different PCMs. Test results indicate that the organic PCM (Methyl Laurate) outperforms salt-hydrate PCMs due to a lower melting temperature and a narrower melting temperature range during the phase change process. The results of this study provide a guide for PCM selection and the optimal design of DPUTB.

Wang, Lingshi↗

Optimisation of the Search for CP-symmetry Violation at the Deep Underground Neutrino Experiment

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long baseline experiment, which will be situated in South Dakota. Its detectors will utilise liquid-argon time projection chamber technology, which is able to capture neutrino interactions with an incredible spatial and calorimetric resolution. With what will become the world’s most intense neutrino beam, a highly capable near detector, and four (10kt fducial mass) far detector modules, DUNE will be able to achieve an ambitious physics programme. Most notably, DUNE will determine whether charge-parity symmetry is broken in neutrino oscillations - a finding that would have significant implications for the understanding of the matter-antimatter asymmetry in our Universe.This thesis presents the optimisation of a CP-violation analysis at DUNE using thePandora pattern-recognition software. The analysis assumes a 3.5 year exposure (1.36 × 1023 protons on target) to a neutrino and an antineutrino beam (7 year total). Only the predicted data of the far detector modules is used; near detector samples are not included. The initial sensitivity to CP-violation is found to be 3.8σ+0.9σ−1.1σ in an estimate that includes oscillation parameter uncertainties, systematic uncertainties and statistical fluctuations, and assumes a normal-ordering of the neutrino mass hierarchy. The performance of the Pandora event reconstruction is linked to that of the analysis, which is found to be limited by the reconstruction of the initial track-like region of electrons and photons. The ShowerRefinement algorithm is developed in response to this and its implementation into the analysis workflow results in an improved sensitivity to CP-violation of 4.6σ+0.9σ−1.0σ. With a perfected neutrino interaction vertex placement, this is further increased to 5.1σ+1.0σ−1.1σ.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Boosted Dark Matter Search with the ICARUS Detector at the Gran Sasso Underground National Laboratory

The quest to discover dark matter is one of the most pressing topics in modern physics. Evidence of gravitational anomalies is present at different cosmological scales, spanning the stability and rotation of galaxies to the overall density profile of the entire observable Universe. Due to the discrepancy between the mass measured and the gravitational influence on the mass, if General Relativity is to correctly describe gravity at different scales, extra electromagnetically invisible matter termed dark matter must exist. In recent decades, many experiments have been performed to detect dark matter with masses that span many orders of magnitude, from Mass Compact Halo Objects (MACHOs) with masses several orders of magnitude that of our sun to very light particles on the order of $\sim\mu$eV. However, experiments have only been able to constrain the possible parameter space of dark matter models and, in general, probe dark matter models with single constituent dark matter like Weakly Interacting Massive Particles (WIMPs). In the Boosted Dark Matter (BDM) paradigm, there are four particles in the dark sector: $\chi_0$, $\chi_1$, $\chi_2$, and the dark photon $X$. WIMP-like properties are ascribed to $\chi_0$ to describe the physics of the gravitational anomalies, while relativistic components are assigned to $\chi_1$ and $\chi_2$. The inelastic boosted dark matter (iBDM) channel $\chi_1 e^-\rightarrow \chi_2 e^-\rightarrow \chi_1 Xe^-\rightarrow \chi_1 (e^+ e^- ) e^-$, where $\chi_2$ is an excited state of $\chi_1$, has a unique signature that is distinguishable from neutrino interactions, making neutrino experiments a viable search environment for BDM. Using data collected by the ICARUS collaboration with ICARUS T-600 Liquid Argon Time Projection Chamber (LArTPC) during its operation at the Gran Sasso Underground Laboratory (LNGS), the first-ever LArTPC dark matter search using the ICARUS detector is presented. With a total detector exposure of 0.13 kton$\cdot$year, a total of 4 iBDM candidate events were identified by several stages of data scanning. All were rejected due to defined selection criteria and a wire-by-wire $dE/dx$ evaluation, giving a null result. Exclusion plots at 90\%C.L. for the dark photon ($m_X$, $\epsilon$) parameter space for fixed ($m_0,m_1,m_2$) DM mass sets are presented, setting new limits on the dark photon visible decay parameter space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Assessing the Economic Value of Underground Thermal Storage for Hybrid Geothermal Power

Solutions are needed to address resource adequacy in the electric power system for highly decarbonized systems. The storage duration, the length of time a storage device can provide continuous output at its rated capacity, must be sufficient to receive full credit toward resource adequacy. Longer peaks and high fractions of variable renewable generation have increased the required duration to potentially seasonal durations. Underground Thermal Energy Storage (UTES) can be adapted to a hybrid storage power plant or heating and cooling applications to satisfy the need for long-duration storage. In this study, we use the Renewable Energy Deployment System (ReEDS) capacity expansion model to evaluate the increase in value for an enhanced geothermal system (EGS) resources by adding UTES. In modeled scenarios, using geothermal without storage as a baseline we compare the increase in economic value for plants with a range of storage characteristics. The added value of a hybrid storage plant changes depending on assumptions including the length of storage duration, efficiency, and ability to charge storage from the grid during periods of low energy prices. Relating proposed characteristics for geothermal UTES hybrids to the modeled economic value provides insight into economically viable costs for developing UTES as well as what combination of technology characteristics and future energy and policy assumptions drive significant value increases.

capacity expansion model↗

Reducing Data Center Peak Cooling Demand and Energy Costs with Underground Thermal Energy Storage (UTES)

By recent estimates, data center energy demands are projected to consume between 6.7% and 12% of U.S. annual electricity generation by the year 2028, driven primarily by expanded demands from cloud services, big data analytics, and Artificial Intelligence (AI) (Shehabi et al., 2024). As much as 40% of data center total energy consumption are loads associated with the site infrastructure cooling systems, and these are often highly water consumptive (Aljbour et al., 2024). For energy system planners, this presents significant challenges to meeting and managing the anticipated loads, and especially the peak loads of projected data center deployments. Geothermal technologies offer two unique solutions to these challenges: 1) by serving loads through the deployment of new conventional and/or next-generation geothermal power technologies such as EGS and 2) through an often-overlooked opportunity to reduce data center peak cooling loads. The latter is the focus of this paper which explores Cold Underground Thermal Energy Storage ("Cold UTES") as an emerging industrial-scale geothermal cooling solution. This cooling solution is energy efficient, non-water-consumptive, and utilizes long duration energy storage (LDES) on both diurnal and seasonal time scales. Cold UTES has the potential to also function as a virtual power plant (VPP). The US Department of Energy's Geothermal Technologies Office is supporting R&D to understand the grid and system-wide value, costs, and impacts of deploying this emergent cooling solution at scale.

AI↗