Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transmission Electron Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Robust Atomic-Resolution Imaging of Lithium in Battery Materials by Center-of-Mass Scanning Transmission Electron Microscopy

The performance of energy storage materials is often governed by their structure at the atomic scale. Conventional electron microscopy can provide detailed information about materials at these length scales, but direct imaging of light elements such as lithium presents a challenge. While several recent techniques allow lithium columns to be distinguished, these typically either involve complex contrast mechanisms that make image interpretation difficult or require significant expertise to perform. In this work, we demonstrate how center-of-mass scanning transmission electron microscopy (CoM-STEM) provides an enhanced ability for simultaneous imaging of lithium and heavier element columns in lithium ion conductors. Through a combination of experiments and multislice electron scattering calculations, we show that CoM-STEM is straightforward to perform and produces directly interpretable contrast for thin samples, while being more robust to variations in experimental parameters than previously demonstrated techniques. As a result, CoM-STEM is positioned to become a reliable and facile method for directly probing all elements within energy storage materials at the atomic scale.

25 ENERGY STORAGE↗

In-Situ Liquid Cell Transmission Electron Microscopy of Nanoparticles from Spent Nuclear Fuel

Noble Metal Particles (NMP) that are present in SNF play an important role in the Fuel Matrix Degradation (FMD) Model that is being considered for predicting the release rate of radionuclides from a waste package. Previous characterization of chemically separated NMP from SNF showed that these were well-crystallized nanoparticles containing Mo, Tc, Ru, Rh, and Pd with some evidence of actinides. These same chemically separated particles were re-characterized following 10 years of storage as the separated material in water. Scanning Transmission Electron Microscopy (STEM) analysis revealed that significant alteration had occurred in this material during storage, resulting in the almost complete degradation of the NMP. We hypothesized that radiolytic damaged had occurred in the material. To support these concepts, we synthesized a mixed Ru-Pd nanoparticle and subjected it to irradiation in the electron microscope in an in-situ liquid cell. We demonstrated that intense radiation can lead to the decomposition of these metallic particles.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A New Coordinated NanoSIMS, Transmission Electron Microscopy and Atom Probe Tomography Approach For the Characterization of Primitive Astromaterials

Presolar grains are remnants of evolved stellar systems preserved within primitive extraterrestrial materials. They are important for studying physical and chemical processing, and formation mechanisms occurring within the interstellar medium, Solar Nebula and their parent stellar environments [1]. Our recent work has shown coordinated nano-scale Secondary Ion Mass Spectrometry (NanoSIMS) and Atom Probe Tomography (APT) can show isotopic and chemical signatures at major to trace levels, morphological signatures, and regional contextual relationships [2,3]. Previous studies have shown Transmission Electron Microscopy (TEM) of Focus Ion Beam (FIB) TEM lamella, can provide localized contextual relationships, crystallographic information and chemical information [1]. Coordinating NanoSIMS, TEM, and APT could gain access to almost all contextual, structural and geochemical signatures within each presolar grain. However, this has proved challenging owing to the preparation requirements for TEM and APT. For example, studying specimen prepared as APT needles in TEM removes the local context, the higher degree of surface exposure can alter the chemistry of beam sensitive materials, and the shank angle of the needle can impact the quality of TEM diffraction images. We designed a new FIB method which takes a 100 nm thick FIB-TEM lamella and sandwiches it between two indium slices (5 μm x ~300 nm x 3 μm). The indium is melted onto the lamella surface using the electron beam (Fig 1). This process adds bulk to the lamella, making it more amenable to APT needle formation (Fig 2). Consequently, samples can be prepared per the optimal requirements for each technique improving data quality, acquisition stability, and access to the signatures and relationships summarised earlier. This technique can be used for measuring multiple phases across a TEM lamella and targeting an individual phase. For example, a presolar grain identified in NanoSIMS could be targeted, studied in TEM and then indium sandwiched with its precise location in the TEM lamella marked using a Pt button for preparation of an APT needle and atomic scale acquisition. [1] A. M. Davis (2014) Meteorites and cosmochemical processes, 1. [2] Nevill N. et al. (2023) LPSC, 54, #1707. [3] Nevill N. et al. (2023) LPSC, 54, #1714.

NanoSIMS↗

Micrometer to Atomic Scale Characterisation of Primitive Astromaterials Using A Novel Method, Metis-Fa: A Coordinated Atom Probe Tomography, Transmission Electron Microscopy and NanoSIMS Approach

Introduction: Presolar grains preserve isotopic, chemical and microstructural records of physical and chemical processing, and formation mechanisms within a vast range of evolved stellar systems, the interstellar medium, solar nebula and their parent bodies. These evolutionary records are preserved at the micrometric to atomic scale, requiring coordinated studies to expand our understanding of evolutionary processes occurringthroughout ours and external stellar systems [1]. NanoSIMS enabled rapid in situ identification and isotopic characterisation of presolar grains and their stellar origins using 17O/16O and 18O/16O, and 13C/12C isotopic ratios [1]. Coordination with transmission electron microscopy (TEM) revealed crystallographic and localised contextual relationships and quantitively constrained their major and minor compositions [1]. However, trace elements cannot be quantified, the most sensitive geochemical tracers of environmental conditions, essential to unravelling the chemical record of their evolutionary pathway and parent stellar systems [2-3] . Furthermore, owing to the combination of technical limitations (only 5 – 7 isotopes can be measured per NanoSIMS run) and their small grain sizes of 100 nm < 3 μm (with rare exceptions in nanodiamonds (2 nm ≤) and SiC (< 40 μm)), the number of measurable isotopes per grain volume is limited [1,3] . Through more comprehensive isotopic studies of presolar grains, NanoSIMS studies have shown the importance of the latter, identifying Fe and Mg as important indicators of nuclear synthetic processing and their stellar origins, respectively [4- 5]. Coordination of NanoSIMS and Atom Probe Tomography (APT) revealed morphological signatures, and isotopic and chemical signatures at major to trace levels without requirements for preselection of elements [6]. However, crystallographic signatures in localized contextual relationships cannot be measured. Consequently, coordination of NanoSIMS, TEM and APT is essential to gain access to almost all contextual, structural and geochemical signatures within each presolar grain.Transmission electron microscopy requires a 100 nm thin lamella which is unstable in APT and would not produce any viable data. Atom probe tomography requires a needle-shaped specimen which when measured in TEM removes the local context, impacts the quality of the TEM diffraction images due to the shank angle of the needle, and can alter the chemistry of beam sensitive materials from the higher degree of surface exposure at the tip. To address these issues, we developed METIS-Fa (Multi-technical measurements of Electron Transparent materials using an Indium Sandwich - a FIB approach). A novel method which enables coordination of NanoSIMS, TEM and APT for generalized and targeted studies of individual grains, including beam sensitive materials, without compromising sample preparation requirements for TEM and APT. This method requires only indium and a Focus Ion Beam (FIB), minimizing the movement of fragile materials while still enabling preparation of TEM lamella into APT needles. Samples: Initial experimental development and testing of the method occurred at Astromaterials Research and Exploration Science (ARES), Johnson Space Centre (JSC), NASA and APT measurements and needle preparation occurred at JdLC, Curtin University. Synthetic silicate samples were used as analogs for presolar silicates when performing a trial run of the method. Samples were extracted from a polished thin section created at JSC, NASA, comprised of 38 wt.% Si, 17 wt.% FeO, 13 wt.% MgO, 12 wt.% Al, 11 wt.% Ca based on electron microprobe analysis (EMPA) [8] . Experimental details, pressure and temperature conditions were presented in [8] and references therein. Testing of the capability to target individual grains in mineral matrices using this method for acquisition in APT, measured matrix regions in meteoritic thin sections of primitive meteorites. These meteorites and their identified presolar grains for future targeted studies are detailed in [9]. Techniques: The TEM-FIB lamella were prepared using a FIB. An e-beam assisted pt deposition was used as a protective coating for the synthetic and meteoritic samples. When targeting individual grains, a secondary e-beam assisted pt deposition button is placed over the desired grain before the protective coating to denote its location. A JEOL 2500SE field-emission TEM was used for high-resolution imaging, energy-dispersive X-ray (EDX) and electron diffraction data.TheMETIS-Fa method was experimentally designed, tested and executed using a FIB at ARES, JSCNASA. Needles for APT were prepared using the Tescan Lyra3 GM Dual Beam Focus Ion Beam (FIB) Field Emission SEM (FE-SEM) at the JdLC, Curtin University. Atom probe tomography measurements were conducted using a CAMECA Local Electrode Atom Probe, LEAP 4000X HR. Two pure indium needles were analyzed initially to constraining acquisition parameters and stability under the beam. Manual acquisition was required to maintain evaporation of specimen’s at the apex and monitor interactions with measurement parameters. Experimental Design: Indium foil is pressed onto an Al stub with a pneumatic press and mounted into the FIB adjacent to the TEM-FIB lamella of interest. Using a FIB, two indium slices (5 μm x ~300 nm x 3 μm) are extracted from indium foil and aligned with the TEM-FIB lamella before touching the TEM-FIB lamella. Each slice is then attached through cold welding to the FIB-TEM lamella. This approach eliminates the need for chemical treatments and proved effective for aligning the Indium within the region of interest for APT, holding it in place for up to 4 days during testing.Once both indium slices are attached within their pre-determined region per grain targeting requirements, they are gradually melted onto the FIB-TEM lamella.When targeting a specific grain, measurements should be taken of the pt button and its distance from edge to edge of the lamella before and after sandwiching. A secondary button should be placed over the same region after the Indium slices have been attached to improve precision when preparing APT needles. Results: Figure 1 shows two indium slices melted onto a FIB-TEM lamella, adding additional bulk for preparation into APT needles as shown in Figure 2 [7] . The latter was essential so samples could be measured in TEM and APT without compromising sample preparation requirements and consequently data quality and acquisition stability. METIS-Fa proved effective forimproving geometry. Figure 3 shows a successful APTrun of the synthetic silicate. EMPA, TEM and APTshowed no chemical alterations. During targetingtesting, a solar silicate grain was successfully identifiedand measured in TEM, and prepared into an APTneedle. However, the indium was melted too long during sample preparation, causing expansion andformation of internal porosity leading to sample loss.Conclusion: METIS-Fa greatly expands the number of isotopic and chemical signatures measured per grain volume, and enables measurements of contextual, structural, crystallographic, isotopic and geochemical signatures within individual grains. Gaining access to such a vast range of evolutionary signatures required for expanding our understanding of external stellar and planetary systems and the evolution of our solar system. This method was designed for application to a vast range of phases including being sensitive materials and thus provides a way for coordination of NanoSIMS, TEM and APT not just for the study of presolar grains and by extension primitive astromaterials, but studies in a vast range of other fields including the geosciences and material sciences.Acknowledgments: Thankyou to ARES, JSC, NASA; JdLC Curtin University and Space Science Technology Centre for the use of laboratory facilities and funding [confirm].

Nicole D Nevill↗

Mixing states of Amazon-basin aerosol particles transported over long distances using transmission electron microscopy

The Amazon basin is important for understanding the global climate both because of its carbon cycle and as a laboratory for obtaining basic knowledge of the continental background atmosphere. Aerosol particles play an important role in the climate and weather, and knowledge of their compositions and mixing states is necessary to understand their influence on the climate. For this study, we collected aerosol particles from the Amazon basin during the Green Ocean Amazon (GoAmazon2014/5) campaign (February to March 2014) at the T3 site, which locates about 70 km from Manaus, and analyzed using transmission electron microscopy (TEM). TEM has better spatial resolution than other instruments, which enables us to analyse the occurrences of components that attach to or are embedded within other particles. Based on the TEM results of more than 10,000 particles from several transport events, this study shows the occurrences of individual particles including compositions, size distributions, number fractions, and possible sources of materials that mix with other particles. Aerosol particles during the wet season were from both natural sources such as the Amazon forest, Saharan desert, Atlantic Ocean, and African biomass burning and anthropogenic sources such as Manaus and local emissions. These particles mix together at an individual particle scale. The number fractions of mineral dust and sea-salt particles increased almost three-fold when long-range transport (LRT) from the African continent occurred. Nearly 20 % of mineral dust and primary biological aerosol particles attached sea salts on their surfaces. Sulfates were also internally mixed with sea-salt and mineral dust particles. The TEM element mapping images showed that several components with sizes of hundreds of nanometres from different sources commonly occur within individual LRT aerosol particles. We conclude that many aerosol particles from natural sources change their compositions by mixing during transport. The compositions and mixing states of these particles after emission result in changes in their hygroscopic and optical properties and should be considered when assessing their effects on climate.

54 ENVIRONMENTAL SCIENCES↗

Mixing states of Amazon basin aerosol particles transported over long distances using transmission electron microscopy

The Amazon basin is important for understanding the global climate because of its carbon cycle and as a laboratory for obtaining basic knowledge of the continental background atmosphere. Aerosol particles play an important role in the climate and weather, and knowledge of their compositions and mixing states is necessary to understand their influence on the climate. For this study, we collected aerosol particles from the Amazon basin during the Green Ocean Amazon (GoAmazon2014/5) campaign (February to March 2014) at the T3 site, which is located about 70 km from Manaus, and analyzed them using transmission electron microscopy (TEM). TEM has better spatial resolution than other instruments, which enables us to analyze the occurrences of components that attach to or are embedded within other particles. Based on the TEM results of more than 10 000 particles from several transport events, this study shows the occurrences of individual particles including compositions, size distributions, number fractions, and possible sources of materials that mix with other particles. Aerosol particles during the wet season were from both natural sources such as the Amazon forest, Saharan desert, Atlantic Ocean, and African biomass burning and anthropogenic sources such as Manaus and local emissions. These particles mix together at an individual particle scale. The number fractions of mineral dust and sea-salt particles increased almost 3-fold when long-range transport (LRT) from the African continent occurred. Nearly 20 % of mineral dust and primary biological aerosol particles had attached sea salts on their surfaces. Sulfates were also internally mixed with sea-salt and mineral dust particles. The TEM element mapping images showed that several components with sizes of hundreds of nanometers from different sources commonly occur within individual LRT aerosol particles. We conclude that many aerosol particles from natural sources change their compositions by mixing during transport. The compositions and mixing states of these particles after emission result in changes in their hygroscopic and optical properties and should be considered when assessing their effects on climate.

54 ENVIRONMENTAL SCIENCES↗

Ultrahigh temperature in situ transmission electron microscopy based bicrystal coble creep in zirconia I: Nanowire growth and interfacial diffusivity

This study demonstrates novel in situ transmission electron microscopy-based microscale single grain boundary Coble creep experiments used to grow nanowires through a solid-state process in cubic ZrO 2 between ≈ 1200 °C and ≈ 2100 °C. Experiments indicate Coble creep drives the formation of nanowires from asperity contacts during tensile displacement, which is confirmed by phase field simulations. The experiments also facilitate efficient measurement of grain boundary diffusivity and surface diffusivity. 10 mol% Sc 2 O 3 doped ZrO 2 is found to have a cation grain boundary diffusivity of $D_{gb} = (0.056 ± 0.05)exp (\frac{-380,000±41,000}{RT})m^2 s^{-1}$, and $D_s = (0.10 ± 0.27)exp(\frac{-380,000 ± 28,000}{RT}) m^2 s^{-1}$.

36 MATERIALS SCIENCE↗

Atomic resolution scanning transmission electron microscopy at liquid helium temperatures for quantum materials

Fundamental quantum phenomena in condensed matter, ranging from correlated electron systems to quantum information processors, manifest their emergent characteristics and behaviors predominantly at low temperatures. This necessitates the use of liquid helium (LHe) cooling for experimental observation. Atomic resolution scanning transmission electron microscopy combined with LHe cooling (cryo-STEM) provides a powerful characterization technique to probe local atomic structural modulations and their coupling with charge, spin and orbital degrees-of-freedom in quantum materials. However, achieving atomic resolution in cryo-STEM is exceptionally challenging, primarily due to sample drifts arising from temperature changes and noises associated with LHe bubbling, turbulent gas flow, etc. In this work, we demonstrate atomic resolution cryo-STEM imaging at LHe temperatures using a commercial side-entry LHe cooling holder. Firstly, we examine STEM imaging performance as a function of He gas flow rate, identifying two primary noise sources: He-gas pulsing and He-gas bubbling. Secondly, we propose two strategies to achieve low noise conditions for atomic resolution STEM imaging: either by temporarily suppressing He gas flow rate using the needle valve or by acquiring images during the natural warming process. Lastly, we show the applications of image acquisition methods and image processing techniques in investigating structural phase transitions in Cr 2 Ge 2 Te 6 , CuIr 2 S 4 , and CrCl 3 . In conclusion, our findings represent an advance in the field of atomic resolution electron microscopy imaging for quantum materials and devices at LHe temperatures, which can be applied to other commercial side-entry LHe cooling TEM holders.

36 MATERIALS SCIENCE↗

Autonomous fabrication of tailored defect structures in 2D materials using machine learning-enabled scanning transmission electron microscopy

Materials with tailored quantum properties can be engineered from atomic-scale assembly techniques, but existing methods often lack the agility and accuracy to precisely and intelligently control the manufacturing process. Here, we demonstrate a fully autonomous approach for fabricating atomic-level defects using electron beams in scanning transmission electron microscopy (STEM) that combines advanced machine learning and automated beam control. As a proof of concept, we achieved controlled fabrication of MoS-nanowire (MoS-NW) edge structures by iterative and targeted exposure of MoS 2 monolayer to a focused electron beam to selectively eject sulfur atoms, utilizing high-angle annular dark-field (HAADF) imaging for feedback-controlled monitoring of structural evolution of defects. A machine learning framework combining a random forest model and a convolutional neural network (CNN) was developed to decode the HAADF image and accurately identify atomic positions and species. This atomic-level information was then integrated into an autonomous decision-making platform, which applied predefined fabrication strategies to instruct beam control about atomic sites to be ejected. The selected sites were subsequently exposed to a localized electron beam using an FPGA-controlled scan routine with precise control over beam positioning and duration. While the MoS-NW edge structures produced exhibit promising mechanical and electronic properties, the proposed methods to build the autonomous fabrication framework is material-agnostic and can be extended to other 2D materials for the creation of diverse defect structures and heterostructures beyond Mo S2 .

Engineering↗

Lattice Strain Measurement of Core@Shell Electrocatalysts with 4D Scanning Transmission Electron Microscopy Nanobeam Electron Diffraction

Strain engineering enables the direct modification of atomic bonding and is currently an active area of research aimed at improving electrocatalytic activity. However, directly measuring the lattice strain of individual catalyst nanoparticles is challenging, especially at the scale of a single unit cell. In this study, we quantitatively map the strain present in rhodium@platinum (core@shell) nanocube electrocatalysts using conventional aberration-corrected scanning transmission electron microscopy (STEM) and the recently developed technique of 4D-STEM nanobeam electron diffraction. We demonstrate that 4D-STEM combined with data preconditioning allows for quantitative lattice strain mapping with subpicometer precision and without the influence of scan distortions. When combined with multivariate curve resolution, 4D-STEM allows us to distinguish the nanocube core from the shell and to quantify the unit cell size as a function of distance from the core–shell interface. Our results demonstrate that 4D-STEM has significant precision and accuracy advantages in strain metrology of catalyst materials compared to aberration-corrected STEM imaging and is beneficial for extracting information about the evolution of strain in catalyst nanoparticles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Operando Electrochemical Liquid-Cell Scanning Transmission Electron Microscopy (EC-STEM) Studies of Evolving Cu Nanocatalysts for CO 2 Electroreduction

The design and synthesis of nanocatalysts with well-defined sizes, compositions, and structures have revolutionized our accessibility to tunable catalyst activity and selectivity for a variety of energy-related electrochemical reactions. Nonetheless, establishing structure-(re)activity correlations requires the understanding of the dynamic evolution of pristine nanocatalysts and the identification of their active states under operating conditions. We previously communicated the operando observation of Cu nanocatalysts evolving into active metallic Cu nanograins for CO 2 electroreduction (Yang et al. Nature 2023, 614, 262–269). Here, we expand our discussion to the technical capabilities and further research applications of operando electrochemical liquid-cell scanning transmission electron microscopy (EC-STEM), which enables quantitative electrochemistry while tracking dynamic structural evolution of sub-10 nm Cu nanocatalysts. The coexistent H 2 bubbles, often disruptive to operando spectroscopy, are an effective approach to create a thin-liquid layer that significantly improves spatial resolution while remaining electrochemically accessible to Cu nanocatalysts. Operando four-dimensional (4D) STEM in liquids provides insights into the complex structure of active polycrystalline metallic Cu nanograins. With continuous technical developments, we anticipate that operando EC-STEM will evolve into a powerful electroanalytical method to advance our understanding of a variety of nanoscale electrocatalysts at solid/liquid interfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Focused Ion Beam-Scanning Transmission Electron Microscopy with Energy-Dispersive X-ray Spectroscopy Study on Technetium Incorporation within Iron Oxides through Fe(OH) 2 (s) Mineral Transformation

Incorporation of Tc(IV) into iron oxide/hydroxide minerals has been explored and proposed as a promising pathway to preventing Tc(IV) reoxidation to environmentally mobile pertechnetate (TcO 4 - ) and improving long-term immobilization of radioactive technetium-99 (Tc). However, visual evidence evaluating the distribution of Tc(IV) incorporated within iron oxide/hydroxide phases has not been available, until now, despite potential implications on Tc(IV) stability within the host phase. For the purpose of this study Tc(IV) incorporation into iron oxide/hydroxide phases was facilitated via Fe(OH) 2 (s) oxidation and mineral transformation to magnetite (Fe 3 O 4 ). Focused ion beam - scanning transmission electron microscopy equipped with energy-dispersive X-ray spectroscopy (FIB/STEM-EDS) methods were then combined with X-ray diffraction and absorption spectroscopy techniques to characterize and visually demonstrate that, for the first time, Tc(IV) is heterogeneously incorporated into different iron oxide/hydroxide phases as Tc(IV)-incorporated magnetite and/or TcO 2 ·2H 2 O(s) via different incorporation mechanisms. Heterogeneous distribution of Tc(IV) in magnetite suggests either (i) TcO4- is reduced quickly at the magnetite surface and then encapsulated into magnetite during continued octahedral crystal growth, or (ii) Tc(IV) alternatively partitioned into multiple layers of a blocky, plate-like morphological magnetite structure showing stratified Tc. With limited Tc-hematite (Fe 2 O 3 ) incorporation, the results suggest that TcO 2 ·2H 2 O(s) is formed and mainly associated/embedded in fibrous nanometer-sized polycrystalline hematite. This work highlights the power of modern state-of-the-art FIB/STEM-EDS approach to provide essential visual insights of the Tc-iron oxide/hydroxide incorporation and generate reliable mechanism-informed designs for waste forms relying on Tc mineral incorporation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Creating ground truth for nanocrystal morphology: a fully automated pipeline for unbiased transmission electron microscopy analysis

Control over colloidal nanocrystal morphology (size, size distribution, and shape) is important for tailoring the functionality of individual nanocrystals and their ensemble behavior. Despite this, traditional methods to quantify nanocrystal morphology are laborious. New developments in automated morphology classification will accelerate these analyses but the assessment of machine learning models is limited by human accuracy for ground truth, causing even unsupervised machine learning models to have inherent bias. Herein, we introduce synthetic image rendering to solve the ground truth problem of nanocrystal morphology classification. By simulating 2D images of nanocrystal shapes via a function of high-dimensional parameter space, we trained a convolutional neural network to link unique morphologies to their simulated parameters, defining nanocrystal morphology quantitatively rather than qualitatively. An automated pipeline then processes, quantitatively defines, and classifies nanocrystal morphology from experimental transmission electron microscopy (TEM) images. Using improved computer vision techniques, 42,650 nanocrystals were identified, assessed, and labeled with quantitative parameters, offering a 600-fold improvement in efficiency over best-practice manual measurements. Further, a classification algorithm was trained with a prediction accuracy of 99.5%, which can successfully analyze a range of concave, convex, and irregular nanocrystal shapes. The resulting pipeline was applied to differentiating two syntheses of nominally cuboidal CsPbBr 3 nanocrystals and uniquely classifying binary nickel sulfide nanocrystal phase based on morphology. This pipeline provides a simple, efficient, and unbiased method to quantify nanocrystal morphology and represents a practical route to construct large datasets with an absolute ground truth for training unbiased morphology-based machine learning algorithms.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Strain-driven oxygen vacancy ordering in LaNiO 3 thin films revealed by integrated differential phase contrast imaging in scanning transmission electron microscopy

Rare-earth nickelates, such as LaNiO 3 (LNO), exhibit complex electronic properties, with ordered oxygen vacancies (OOV) influencing conductivity and magnetic behavior. We investigate the structural stability of strain-induced OOV phases in LNO thin films grown on SrTiO 3 substrates and the impact of Ruddlesden–Popper (RP) faults. Using high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM) and integrated differential phase contrast (iDPC) STEM imaging, we conducted atomic-scale structural and compositional analyses of OOV. Geometric phase analysis (GPA) was employed to measure the strain in fault-free and RP fault regions, while density functional theory (DFT) calculations explored different OOV arrangements in the LNO phase. Simulated iDPC-STEM imaging of energy-stabilized structures was performed to correlate with experimental results. Here, our findings reveal superstructure modulation in the chemical composition and atomic-scale lattice structure in LNO, primarily due to the formation of the OOV in Ni–O layers of the LaNiO 2.5 phase. The out-of-plane compressive strain of about 2% stabilizes this phase, reducing the strain, diminishing OOV, and transforming them into LNO.

36 MATERIALS SCIENCE↗

Small Scale Creep Testing of 14YWT via In-situ Transmission Electron Microscopy Irradiation and Nanoindentation

The next generation of nuclear materials must withstand harsh operating conditions such as high temperatures and irradiation doses. Nanostructured ferritic alloys like oxide dispersion strengthened steels, especially 14YWT, have shown promise as a structural material to withstand these harsh operating conditions. For application, understanding the irradiation enhanced creep of the structural components is fundamental to evaluating the service life in a reactor. Challenges with evaluating irradiation enhanced creep are related to the limited space in nuclear reactors and the expense of conducting post irradiation experiments on irradiated cladding. Ion irradiations are considered to expedite irradiation testing, but such experiments have restricted depth of penetration into the material, limiting the ability to characterize changes to material properties after irradiation. Small scale mechanical testing can be used with ion beam irradiations as a potential avenue to evaluate the irradiation enhanced creep of materials. In this study, in-situ transmission electron microscopy nanopillar creep studies on 14YWT were performed and simultaneously ion beam irradiated with 2.8 MeV Au4+ ions. It was observed that the ion beam irradiation did increase the measured strain rate of the materials. In addition, ex-situ nanoindentation creep studies were performed over a range of temperatures on control 14YWT, and it was observed that there was a change in the deformation mechanism between 873 K and 1073 K that agrees well with macro-scale mechanical testing. Furthermore, these results show promise for applying these techniques to nuclear materials in the future.

14 YWT↗

Accelerating Quantum Materials Development with Advances in Transmission Electron Microscopy

Quantum materials are driving a technology revolution in sensing, communication, and computing, while simultaneously testing many core theories of the past century. Materials such as topological insulators, complex oxides, superconductors, quantum dots, color center-hosting semiconductors, and other types of strongly correlated materials can exhibit exotic properties such as edge conductivity, multiferroicity, magnetoresistance, superconductivity, single photon emission, and optical-spin locking. These emergent properties arise and depend strongly on the material’s detailed atomic-scale structure, including atomic defects, dopants, and lattice stacking. In this review, we describe how progress in the field of electron microscopy (EM), including in situ and in operando EM, can accelerate advances in quantum materials and quantum excitations. We begin by describing fundamental EM principles and operation modes. We then discuss various EM methods such as (i) EM spectroscopies, including electron energy loss spectroscopy (EELS), cathodoluminescence (CL), and electron energy gain spectroscopy (EEGS); (ii) four-dimensional scanning transmission electron microscopy (4D-STEM); (iii) dynamic and ultrafast EM (UEM); (iv) complementary ultrafast spectroscopies (UED, XFEL); and (v) atomic electron tomography (AET). We describe how these methods could inform structure–function relations in quantum materials down to the picometer scale and femtosecond time resolution, and how they enable precision positioning of atomic defects and high-resolution manipulation of quantum materials. For each method, we also describe existing limitations to solve open quantum mechanical questions, and how they might be addressed to accelerate progress. Among numerous notable results, our review highlights how EM is enabling identification of the 3D structure of quantum defects; measuring reversible and metastable dynamics of quantum excitations; mapping exciton states and single photon emission; measuring nanoscale thermal transport and coupled excitation dynamics; and measuring the internal electric field and charge density distribution of quantum heterointerfaces- all at the quantum materials’ intrinsic atomic and near atomic-length scale. Finally, we conclude by describing open challenges for the future, including achieving stable sample holders for ultralow temperature (below 10K) atomic-scale spatial resolution, stable spectrometers that enable meV energy resolution, and high-resolution, dynamic mapping of magnetic and spin fields. With atomic manipulation and ultrafast characterization enabled by EM, quantum materials will be poised to integrate into many of the sustainable and energy-efficient technologies needed for the 21st century.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High Resolution Transmission Electron Microscopy (HRTEM) of nanophase ferric oxides

Iron oxide minerals are the prime candidates for Fe(III) signatures in remotely sensed Martian surface spectra. Magnetic, Mossbauer, and reflectance spectroscopy have been carried out in the laboratory in order to understand the mineralogical nature of Martian analog ferric oxide minerals of submicron or nanometer size range. Out of the iron oxide minerals studied, nanometer sized ferric oxides are promising candidates for possible Martian spectral analogs. 'Nanophase ferric oxide (np-Ox)' is a generic term for ferric oxide/oxihydroxide particles having nanoscale (less than 10 nm) particle dimensions. Ferrihydrite, superparamagnetic particles of hematite, maghemite and goethite, and nanometer sized particles of inherently paramagnetic lepidocrocite are all examples of nanophase ferric oxides. np-Ox particles in general do not give X-ray diffraction (XRD) patterns with well defined peaks and would often be classified as X-ray amorphous. Therefore, different np-Oxs preparations should be characterized using a more sensitive technique e.g., high resolution transmission electron microscopy (HRTEM). The purpose of this study is to report the particle size, morphology and crystalline order, of five np-Ox samples by HRTEM imaging and electron diffraction (ED).

Golden, D. C.↗

Probing ferroelectric domain structures and their switching dynamics in SrBi2Ta2O9 by in-situ electric biasing in transmission electron microscopy

Abstract Lead-free SrBi 2 Ta 2 O 9 (SBT) has been a promising ferroelectric material for various applications such as electronics and data storage due to its outstanding ferroelectric properties including high fatigue endurance and low leakage current. However, the atomic-scale domain structure and switching dynamics of ferroelectric SBT remain elusive. This study reveals that spontaneous polarization arises from canted bismuth-cation displacements, forming 90° and Ising-type 180° domain walls. Interestingly, topological pairs of ferroelectric vortex and antivortex connect ferroelectric boundaries where three domain walls converge. In situ electrical biasing transmission electron microscopy (TEM) reveals the dominance of 180° switching over 90°, where oxygen octahedral connectivity is protected by ferroelastic energy in the 90° domain wall. Consequently, all 180° domain walls and (anti)vortices are removed, leaving only 90° domain walls in the electrically poled states. Chemical deterioration along domain walls highlights vulnerability of SBT to ferroelectric fatigue. This study provides insight into crucial aspects for practical applications of SBT.

36 MATERIALS SCIENCE↗