Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transfer Function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

WE-D-204-02: Novel Method for Correcting Degradation of Sharpness of Liquid-Crystal Display Based On Modulation Transfer Function

Purpose: To develop a method for improving sharpness of images reproduced on liquid-crystal displays (LCDs) by compensating for the degradation of modulation transfer function (MTF) of the LCD. Methods: The inherent MTF of a color LCD (display MTF) was measured using a commercially available color digital camera. The frequency responses necessary to compensate for the resolution property of the LCD were calculated from the inverses of the display MTFs in both the horizontal and vertical directions. In addition, the inverses of the display MTFs were combined with the response of the human eye. The finite impulse response (FIR) filters were computed by taking the inverse Fourier transform of the frequency responses, and the effects of the FIR filtering on both the resolution and noise properties of the displayed images were verified by measuring the MTF and Wiener spectrum (WS), respectively. The FIR filtering was then applied to the representation of digital bone and chest radiographs. Results: The FIR filtering improved the MTF values by up to almost 1.0 or greater over the frequency range of interest, while it minimally increased the WS values. Combining the inverses of the display MTFs with the response of the human eye led to further refinement of the MTF. Our method was successfully and beneficially applied to the image interpretation of bone radiographs. The resolution enhancement of chest radiographs, which include larger scattered radiation than bone radiographs, was easily perceived by incorporating the response of the human eye. In addition, no artifacts were observed on the processed images. Conclusion: Our proposed method to compensate for the degradation of the resolution properties of LCDs has the potential to improve the observer performance of radiologists when reading digital radiographs. This work was supported in part by grant from EIZO Corporation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Strictly positive real transfer functions revisited

The two most commonly used definitions of strictly positive real (SPR) transfer functions are reviewed. Contrary to what has been suggested in the literature, it is proven that the least restrictive (weak) definition of the two is clearly related to the Yacubovich-Kalman lemma. The relationship between time- and frequency-domain conditions pertaining to the weak definition of SPR systems is established.

Lozano-Leal, Rogelio↗

Transfer function bounds on the performance of turbo codes

In this article we apply transfer function bounding techniques to obtain upper bounds on the bit-error rate for maximum likelihood decoding of turbo codes constructed with random permutations. These techniques are applied to two turbo codes with constraint length 3 and later extended to other codes. The performance predicted by these bounds is compared with simulation results. The bounds are useful in estimating the 'error floor' that is difficult to measure by simulation, and they provide insight on how to lower this floor. More refined bounds are needed for accurate performance measures at lower signal-to-noise ratios.

Divsalar, D.↗

Characterizing the modulation transfer function for X-ray radiography in high energy density experiments

Here, the Modulation Transfer Function ( MTF ) is an established means for characterizing imaging performance of X-ray radiography systems. We report on experiments using high energy, laser-driven X-ray radiography systems that assess performance using MTF values measured with the knife-edge projection method. The broadband, hard X-ray systems under study use line-projection imaging produced by narrowing the laser-generated X-ray source with a slit. We find that good contrast resolution can be achieved (the MTF = 0.5 at 75 μm wavelength) and that this performance is reproduced on different laser facilities. We also find that the MTF is sensitive both to the thickness of the line-projection slit and to the backing material thickness under the knife-edge. Both these sensitivities are due to a common mechanism, namely induced changes in the spectrally-averaged spatial widths of the X-ray source. The same line-projection system is also used on experimental campaigns measuring Rayleigh-Taylor instability growth by dynamically imaging sinusoidal, high Z micro-targets with wavelengths of 100 μm or less. By applying the measured MTF values to correct the ripple target contrast measurements, we can predict ripple growth to approximately 10% accuracy.

47 OTHER INSTRUMENTATION↗

Applications of Displacement Transfer Functions to Deformed Shape Predictions of the GIII Swept-Wing Structure

The displacement transfer functions (DTFs) were applied to the GIII swept wing for the deformed shape prediction. The calculated deformed shapes are very close to the correlated finite element results as well as the measured data. The convergence study showed that using 17 strain stations, the wing-tip displacement prediction error was 1.6 percent, and that there is no need to use a large number of strain stations for G-III wing shape predictions.

on board string sensing system↗

Determination of transfer function of COPE correlation interferometer instrument

The comparison of theoretical and instrument response functions and its use as a procedure for determining the transfer function of the COPE correlation interferometer are summarized. Data show qualitative agreement can be obtained when discrepancies between theory and instrument are investigated and instrument components are analyzed in detail. Data were obtained using a set of calibration data and computer algorithms.

Twitty, J.↗

The transfer function method for gear system dynamics applied to conventional and minimum excitation gearing designs

A transfer function method for predicting the dynamic responses of gear systems with more than one gear mesh is developed and applied to the NASA Lewis four-square gear fatigue test apparatus. Methods for computing bearing-support force spectra and temporal histories of the total force transmitted by a gear mesh, the force transmitted by a single pair of teeth, and the maximum root stress in a single tooth are developed. Dynamic effects arising from other gear meshes in the system are included. A profile modification design method to minimize the vibration excitation arising from a pair of meshing gears is reviewed and extended. Families of tooth loading functions required for such designs are developed and examined for potential excitation of individual tooth vibrations. The profile modification design method is applied to a pair of test gears.

Mark, W. D.↗

A moving slanted-edge method to measure the temporal modulation transfer function of fluoroscopic systems

Lag in fluoroscopic systems introduces a frame-averaging effect that reduces measurements of image noise and incorrectly inflates measurements of the detective quantum efficiency (DQE). A correction can be implemented based on measurements of the temporal modulation transfer function (MTF). We introduce a method of measuring the temporal MTF under fluoroscopic conditions using a moving slanted edge, a generalization of the slanted-edge method used to measure the (spatial) MTF, providing the temporal MTF of the entire imaging system. The method uses a single x-ray exposure, constant edge velocity, and assumes spatial and temporal blurring are separable. The method was validated on a laboratory x-ray image intensifier (XRII) system by comparison with direct measurements of the XRII optical response, showing excellent agreement over the entire frequency range tested ({+-}100 Hz). With proper access to linearized data and continuous fluoroscopy, this method can be implemented in a clinical setting on both XRII and flat-panel detectors. It is shown that the temporal MTF of the CsI-based validation system is a function of exposure rate. The rising-edge response showed more lag than the falling edge, and the temporal MTF decreased with decreasing exposure rate. It is suggested that a small-signal approach, in which the range of exposure rates is restricted to a linear range by using a semitransparent moving edge, would be appropriate for measuring the DQE of these systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Systems and Methods for Transfer Function Estimation Using Membership Functions

An apparatus, method, and computer program that can learn a linear or non-linear transfer function are disclosed. In one embodiment, for example, a computer-implemented method may include creating a plurality of combinations for at least one input, and calculating an output for the plurality of combinations. The method may also include calculating an error based on the calculated output.

Krasowski, Michael J↗

Analysis of diagnostic calorimeter data by the transfer function technique

This paper describes the analysis procedure applied to the thermal measurements on the rear side of a carbon fibre composite calorimeter with the purpose of reconstructing the energy flux due to an ion beam colliding on the front side. The method is based on the transfer function technique and allows a fast analysis by means of the fast Fourier transform algorithm. Its efficacy has been tested both on simulated and measured temperature profiles: in all cases, the energy flux features are well reproduced and beamlets are well resolved. Limits and restrictions of the method are also discussed, providing strategies to handle issues related to signal noise and digital processing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗